AD620BNZ - Low-Power Instrumentation Amplifier | Analog Devices
料号: AD620BNZ ✓ 量产中AD620BNZ 概述
An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while providing high input impedance, accurate differential gain, and strong rejection of common-mode voltage. Its place in the signal-chain hierarchy is above ordinary operational amplifiers because it combines differential input, gain setting, and common-mode rejection into one integrated circuit. The AD620 is widely used where sensor outputs are small, noisy, and referenced to a voltage that is not ground.
The AD620 architecture is based on a three-op-amp approach with internal gain-setting and absolute-value trimming. According to the Analog Devices AD620 product page, one external resistor programs gains from 1 to 10,000. This simplifies instrumentation designs compared with discrete resistor networks while improving repeatability. The AD620BNZ is identified as a low-power instrumentation amplifier, making it useful where signal fidelity must be balanced against board space and energy use.
The 15 µV offset specification is important for low-level measurements because it limits the input-referred error that can obscure the intended sensor signal. Its 1 MHz bandwidth and 1.2 V/µs slew rate provide adequate speed for many sensor, bridge, and data-acquisition signals, although higher-bandwidth instrumentation amplifiers may be preferable for faster waveforms. The dual supply range of ±2.3 V to ±18 V supports both compact systems and conventional bipolar analog rails.
Typical uses include strain-gauge and load-cell bridge conditioning, thermocouple and RTD signal chains, biomedical instrumentation, industrial process measurement, and precision data acquisition. The AD620 is also useful in current-shunt monitoring and laboratory sensor interfaces where a common-mode voltage varies substantially from ground. Its high input impedance helps preserve the source signal, while differential amplification rejects much of the offset common to both inputs.
For a new design, check input common-mode range, output swing, supply voltage, gain-set resistor accuracy, and settling time against the required signal bandwidth. Use the gain-setting resistor recommended by the manufacturer and place it close to the device. Confirm that the selected gain, output voltage, and input polarity do not exceed the signal-chain limits before laying out the board.
直接替换替代料: AD620BNZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD620BNZ (相同外形与封装尺寸) ——差异在于 Package, Product Type, Mounting Type, Gain Range, Supply Voltage Range.
AD620BN
✅ 直接替换📋 参考替代料(不在目录中)
AD620ANZ
✅ 直接替换联系询价
查看数据手册 →AD620BNZ 最大额定值与电气特性
| Amplifier Type | Instrumentation Amplifier |
| Number of Circuits | 1 circuit |
| Gain Range | 1 to 10,000 |
| Gain Setting | 1 external resistor |
| Input Offset Voltage | 15 µV |
| Slew Rate | 1.2 V/µs |
| Bandwidth | 1 MHz |
| Supply Voltage Range | ±2.3 V to ±18 V |
| 封装 | 8-pin PDIP |
| 安装类型 | Through-hole |
| Power Class | Low-power instrumentation amplifier |
AD620BNZ 8-pin pdip 引脚配置指南
AD620BNZ(8-pin pdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD620BNZ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD620BNZ 适用于 6 应用s: Load-Cell Bridge Amplification, Precision Current-Shunt Measurement, Thermocouple and RTD Conditioning, Biomedical Instrumentation, Industrial Process Measurement, Precision Data Acquisition.
Load-Cell Bridge Amplification
The AD620BNZ fits load-cell and strain-gauge front ends because it amplifies the small differential voltage produced by a resistive bridge while presenting a high input impedance to the sensing element. Its gain can be programmed from 1 to 10,000 with one external resistor, allowing the amplifier to compensate for both low-level millivolt outputs and larger bridge signals. The 15 µV input offset specification is particularly relevant when the bridge output is only slightly above the measurement floor. In the completed design, confirm that bridge excitation and signal common-mode voltages remain inside the amplifier's operating limits, and place the gain resistor close to the device to reduce sensitivity to board leakage and interference.
推荐
Precision Current-Shunt Measurement
The AD620BNZ is suitable for measuring the differential voltage generated across a current shunt when the shunt voltage is small and the common-mode voltage can change substantially. Differential amplification rejects shared voltage on the shunt sense lines, while the single external gain-setting resistor simplifies calibration-oriented analog circuitry. The device's 1 MHz bandwidth and 1.2 V/µs slew rate are appropriate for many current-monitoring loops that do not require high-speed waveform fidelity. Keep the Kelvin sense connections routed as a matched pair and verify that the burden voltage and common-mode excursion stay within the operating limits for the selected operating grade.
推荐
Thermocouple and RTD Conditioning
The AD620BNZ can condition low-level thermocouple or RTD signals when the design requires differential input, adjustable gain, and rejection of common-mode voltage. A thermocouple produces a small voltage relative to a temperature-dependent reference, making the 15 µV offset characteristic relevant to resolution near the lower end of the measurement range. Programmable gain from 1 to 10,000 provides flexibility across different sensor sensitivities. The instrumentation amplifier should be paired with suitable cold-junction compensation for thermocouples, and its input bias current, common-mode range, and offset drift must be compared with the sensor impedance and required accuracy before final selection.
推荐
Biomedical Instrumentation
The AD620BNZ is appropriate for biomedical instrumentation front ends that measure small differential sensor voltages while rejecting common-mode interference from the body, cables, and nearby equipment. Its single-circuit instrumentation-amplifier architecture reduces the number of matched precision resistors normally required for a discrete difference amplifier, and the 15 µV input offset helps preserve weak physiological signals. The AD620BNZ is normally used with suitable input protection, isolation, filtering, and patient-safety circuitry rather than as a complete medical front end. The final system must be evaluated for leakage current, electrode protection, noise, electrical isolation, and the applicable medical-device requirements.
推荐
Industrial Process Measurement
The AD620BNZ supports industrial process-measurement systems that receive low-level differential signals from pressure, flow, level, or vibration sensors. Differential input and high input impedance help preserve sensor output, while the 1 to 10,000 gain range can adapt the amplifier to different sensor sensitivities without a complex external network. The ±2.3 V to ±18 V supply range accommodates compact dual-rail electronics and conventional bipolar instrumentation supplies. In industrial deployments, verify the operating-temperature grade, isolate long sensor wiring appropriately, provide surge and transient protection, and maintain a low-impedance reference connection so ground differences do not dominate the measurement.
推荐
Precision Data Acquisition
The AD620BNZ is useful as the analog input stage in precision data-acquisition systems where differential sensor outputs must be amplified before conversion. The 1 MHz bandwidth accommodates many moderate-rate measurements, while the 15 µV offset limits one important source of signal-chain error. A gain of 1 is useful for higher-level inputs, and higher programmed gains increase sensitivity to weak signals. The anti-alias filter, gain resistor, input protection, and converter interface must be designed together so that settling behavior and source impedance are compatible with the sample rate. Confirm output swing, input range, supply noise, and acquisition timing before selecting the exact AD620 ordering option.
推荐
推荐产品汇总
工程参考数据: AD620BNZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD620BN | AD620ANZ | AD621BNZ | LT1167 |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Linear Technology |
| Package | PDIP-8 | PDIP-8 | PDIP-8 | PDIP-8 | PDIP-8 |
| Amplifier Type | Instrumentation Amplifier | Instrumentation Amplifier | Instrumentation Amplifier | Instrumentation Amplifier | Instrumentation Amplifier |
关键差异点
- One-resistor gain programming (对比 AD621BNZ)
- Documented low-level precision (对比 LT1167)
- Single-circuit integration (对比 AD620ANZ)
设计说明
Check the full signal path before applying gain. The AD620BNZ supports gains from 1 to 10,000 with one external resistor, but high gain also magnifies offset, noise, and error contributed by the source impedance. Confirm that the input common-mode voltage and required output voltage remain within the operating limits. For a drop-in LT1167 substitution, verify supply voltage, bandwidth, settling behavior, and output swing rather than relying only on pin compatibility.
Route the two differential inputs as a matched pair and connect the gain-setting resistor close to the amplifier. Keep high-impedance input nodes away from switching nodes and provide a low-impedance return for the reference pin. This minimizes leakage, induced noise, and ground-potential errors, which are especially important when the AD620BNZ is configured for high gain on low-level sensor signals.
Determine the required bandwidth from sensor dynamics, noise, and the downstream converter rather than selecting gain from sensitivity alone. The AD620BNZ is rated for 1 MHz bandwidth and 1.2 V/µs slew rate, so a large-amplitude output at high frequency may become slew-rate limited. Include an anti-alias filter and verify that source impedance, settling time, and gain selection produce acceptable acquisition accuracy.
合规信息
The AD620 family is an analog instrumentation amplifier rather than an automotive-qualified component. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer or current product documentation.