ams OSRAM

AS7331-AQFM-OLGA16-LF - UVA/UVB/UVC Spectral UV Sensor | ams OSRAM

N.º de pieza: AS7331-AQFM-OLGA16-LF ✓ Activo
En stock Se envía en 1-3 días hábiles
2.7 V to 3.6 V Vdss OLGA-16, 3.65 mm x 2.6 mm (16-TFLGA) Package
Desde $6.94 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-11
Precios por volumen
Cant. Precio unitario Total
1 $10.58 $10,58
10 $9.52 $95,20
100 $8.57 $857,00
500 $7.71 $3.855,00
1.000 $6.94 $6.940,00
ℹ️ Todos los precios están en USD

AS7331-AQFM-OLGA16-LF Descripción general

The ams OSRAM AS7331-AQFM-OLGA16-LF is a low-power, low-noise integrated spectral UV sensor that measures UVA, UVB and UVC radiation in three separated channels, converting optical radiation via UV-optimized photodiodes into 24-bit digital results over an I2C interface, housed in a 16-pin OLGA package measuring 3.65 x 2.6 mm and operating from 2.7 V to 3.6 V over -40 C to +105 C.

A spectral UV sensor is a type of optical sensor that resolves incoming ultraviolet radiation into specific wavelength bands rather than reporting a single total irradiance value. Within the sensor hierarchy (UV sensor -> spectral sensor -> optical sensor -> semiconductor sensor), the AS7331 belongs to ams OSRAM's ambient light, color, spectral and proximity sensor family. Unlike simple UV index sensors that only detect UVA plus some UVB, a true three-band spectral UV sensor separates UVA (roughly the 315-400 nm region), UVB and UVC (down to approximately 260 nm per DigiKey classification) so downstream firmware can distinguish sunlight exposure, germicidal irradiance and curing lamp output.

Key features include the three separated UVA/UVB/UVC channels, 24-bit digital resolution per channel, and adjustable irradiance responsivity: gain, conversion time and internal clock frequency can be programmed to trade sensitivity against full-scale range and LSB size. Four low-power operating modes (including continuous and triggered measurement) support both always-on monitoring and battery-friendly event-driven sampling, as highlighted in the SparkFun and Adafruit breakout documentation.

Technically, the AS7331 converts photocurrent from UV-optimized photodiodes through an integration-based ADC architecture, delivering high dynamic range without external optics. The I2C digital output eliminates analog-to-digital conversion burden on the host microcontroller, and the low-noise front end allows weak UVC signals to be resolved even in compact, unfiltered apertures.

Typical applications include wearable UV index monitors and sun-exposure alerts (UVA/UVB), germicidal lamp verification and disinfection cabinet monitoring (UVC), UV curing process control, and agricultural UV dosing stations, as noted by Adafruit for human and agricultural UV alerts across all three bands.

Design-wise, program the gain and conversion time so expected irradiance sits in the upper half of the 24-bit full scale for best SNR, and account for the 2.7-3.6 V supply budget in battery designs.

This page synthesizes distributor pricing, cross-reference data and practical design notes not found in the manufacturer datasheet, with prices as of 2026-10-11.

Alternativas directas para AS7331-AQFM-OLGA16-LF — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con AS7331-AQFM-OLGA16-LF (mismo factor de forma y huella) — difiere en Interface, Operating Modes, Package, Sensor Type, Supply Voltage.

ams OSRAM
Interface: I2C (adjustable slave address)
Operating Modes: 4 low-power modes; continuous and triggered measurement
Package: 16-pin OLGA / TFLGA, SMD
Comparar con AS7331-AQFM-OLGA16-LF →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

AS7331-AQFM

✅ Sustitución directa
ams OSRAM
📦 OLGA-16
3-channel spectral UV sensor (UVA/UVB/UVC) · 260 nm to 360 nm · 3 (UVA, UVB, UVC) with interference filter technology · I2C (adjustable slave address) · 3.3 V · 16 to 24 bit · up to 3.43E+10 (adjustable) · up to 421 counts/(uW/cm2)

✓ En stock

$7.87 / unidad

Ver hoja de datos →

AS7331-AQFM-OLGA16-LF Valores máximos y características eléctricas

Tipo de sensor Spectral UV Sensor (UVA / UVB / UVC)
Spectral Range 260 nm to 360 nm
Number of Channels 3 (UVA, UVB, UVC)
Resolución 24-bit digital output
Interfaz I2C
Tensión de alimentación 2.7 V to 3.6 V
Temperatura de funcionamiento -40 C to +105 C
Operating Modes 4 (continuous and triggered measurement)
Responsivity Adjustment Via gain, conversion time and internal clock frequency
Photodiode Type UV-optimized photodiodes
Encapsulado OLGA-16, 3.65 mm x 2.6 mm (16-TFLGA)
Tipo de montaje Surface Mount
Power Characteristic Low power, low noise
Estado RoHS Compliant (per JLCPCB/LCSC listing)
Packaging Suffix T&R (Tape and Reel), LF lead-free finish

Guía de configuración de pines de AS7331-AQFM-OLGA16-LF olga-16, 3.65 mm x 2.6 mm (16-tflga)

Configuración de pines para AS7331-AQFM-OLGA16-LF (encapsulado olga-16, 3.65 mm x 2.6 mm (16-tflga)). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.

Diagrama de patillaje del encapsulado olga-16, 3.65 mm x 2.6 mm (16-tflga) para AS7331-AQFM-OLGA16-LF

No hay datos detallados de patillaje disponibles para AS7331-AQFM-OLGA16-LF.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

AS7331-AQFM-OLGA16-LF es adecuado para 6 aplicacións: Wearable UV Index Monitoring, UVC Germicidal Lamp Verification, UV Curing Process Control, Agricultural UV Dosing, Automotive Cabin UV Sensing, Environmental UV Weather Stations.

📱

Wearable UV Index Monitoring

Wearable sun-exposure devices require accurate UVA and UVB measurement in a tiny, power-constrained footprint. The AS7331 fits this role because its OLGA-16 package measures only 3.65 x 2.6 mm and its low-power architecture offers four operating modes, including triggered measurement that wakes the sensor only for periodic sampling. With a supply range of 2.7 V to 3.6 V it runs directly from a 3.3 V battery rail via an LDO, and the 24-bit per-channel resolution lets firmware compute a UV index across bright sunlight and shade without gain switching. The I2C interface draws minimal host overhead, and the industrial -40 C to +105 C rating tolerates a device left on a car dashboard. Place the sensor under a UV-transmitting resin window; standard watch glass blocks UVC and attenuates UVB, so verify window transmission during calibration for accurate exposure alerts.

💡

UVC Germicidal Lamp Verification

Disinfection cabinets, UV sterilizer wands and germicidal enclosures need reliable verification that 254-280 nm UVC output is actually present and maintained over lamp life. The AS7331 is among the few compact digital sensors with a dedicated UVC channel, with spectral coverage listed by DigiKey from 260 nm to 360 nm, enabling direct monitoring of germicidal irradiance that simple UVA/UVB index sensors cannot see. Firmware programs the gain and conversion time so typical lamp irradiance lands in the upper half of the 24-bit full scale, maximizing signal-to-noise ratio, then compares readings against a commissioning baseline to flag lamp aging. Because UVC photodiodes can degrade under chronic exposure and quartz sleeves attenuate output, mount the sensor where line-of-sight to the lamp is unobstructed and schedule periodic recalibration against a reference radiometer for dose-critical medical or food-safety applications.

🏭

UV Curing Process Control

UV curing of adhesives, inks and coatings demands confirmation that target irradiance reaches the bond line, since under-cure causes bond failures and over-cure wastes lamp life. The AS7331's UVA and UVB channels align with the spectral output of typical mercury and UV LED curing lamps, and its programmable responsivity (gain, conversion time, internal clock frequency per the ams OSRAM product page) lets engineers extend the full-scale range for high-intensity curing zones without saturating the 24-bit ADC. In triggered measurement mode, the sensor samples exactly during the exposure window, and the I2C output feeds PLC or MCU-based process controllers that log dose and reject out-of-spec parts. For LED-curing systems centered near 365-395 nm, verify the sensor's response at the specific wavelength against its responsivity curves, since coverage is specified up to roughly 360 nm.

🧩

Agricultural UV Dosing

Controlled-environment agriculture uses targeted UVB and UVC dosing to boost secondary metabolites in herbs, harden seedlings, or suppress powdery mildew. The AS7331 addresses this because, as Adafruit notes, it differentiates all three UV bands, enabling separate control loops for growth-promoting UVA/UVB and pathogen-suppressing UVC exposure. The 24-bit resolution spans dim supplemental lighting through direct solar input, and the -40 C to +105 C operating range survives greenhouse and cold-frame temperature extremes. Firmware integrates each band over the photoperiod to deliver a programmed daily UV dose, opening or closing lamp relays based on live irradiance rather than lamp-rated output, which compensates for lamp aging and dirt on luminaires. Mount the sensor at canopy height facing the light source, and apply lens transmission calibration so the reported dose matches plant-level irradiance rather than sensor-face values.

🚗

Automotive Cabin UV Sensing

Premium vehicles increasingly report cabin and windshield UV load to trigger glare shading, glass coating diagnostics or occupant sun-exposure warnings. The AS7331 suits this environment because its -40 C to +105 C operating range matches automotive interior temperature specifications, and the small 3.65 x 2.6 mm OLGA-16 footprint mounts behind the windshield header or climate-control vent. Its three-band output lets the body controller distinguish windshield-filtered UVA from UVB leaking through open sunroofs, and triggered measurement keeps average current low on the always-on body domain. The I2C interface connects directly to a body-control MCU, typically over short shielded traces below 30 cm to maintain signal integrity in a noisy automotive EMC environment. Because laminated glass blocks most UVB while transmitting UVA, calibrate against installed-glass transmission rather than free-air values for meaningful cabin UV index reporting.

🌐

Environmental UV Weather Stations

Weather stations and smart-city environmental nodes publish UV index alongside temperature, humidity and particulate data. The AS7331 provides true UVA/UVB separation with 24-bit resolution per channel, allowing the station to compute a standardized UV index even under rapidly changing cloud cover, where slower integrating sensors under-respond to bright breaks between clouds. Its low noise lets clear-sky noon irradiance and heavily overcast values be resolved on the same gain setting in many climates, reducing firmware complexity. Supply current suits solar-powered nodes with 3.3 V LiFePO4 or supercapacitor backed rails, and triggered sampling every minute or two keeps the energy budget small. Mount the sensor behind a PTFE or PMMA diffuser to widen the field of view and reduce sensitivity to pointing, then apply a two-point calibration (shadowed and clear-sky reference) to align the node with nearby meteorological UV index reporting.

What is the AS7331-AQFM-OLGA16-LF sensor?
The AS7331-AQFM-OLGA16-LF is a low-power, low-noise integrated spectral UV sensor from ams OSRAM that measures three separate UV bands: UVA, UVB and UVC. It converts optical radiation via UV-optimized photodiodes into 24-bit digital results over an I2C interface, in a 16-pin OLGA package of 3.65 x 2.6 mm. According to the ams OSRAM product page, irradiance responsivity is adjustable via gain, conversion time and internal clock frequency.
What is the operating voltage range of AS7331?
The AS7331 operates from a supply voltage of 2.7 V to 3.6 V, per the LCSC/JLCPCB part listing. This makes it directly compatible with 3.3 V logic rails common on microcontrollers such as the ESP32, STM32 and ARM Cortex-M families. Designs must not exceed 3.6 V on the supply pin, and battery-powered systems should use a low-dropout regulator such as a 3.0 V or 3.3 V LDO to keep the sensor within its specified window.
What temperature range does the AS7331 support?
The AS7331-AQFM-OLGA16-LF operates from -40 C to +105 C according to the LCSC and JLCPCB part data. This industrial-grade temperature range suits outdoor UV index monitors, automotive cabin UV sensors, and industrial UVC disinfection equipment where ambient temperatures can swing widely. Note that optical responsivity can shift over temperature, so calibration firmware should apply temperature compensation for precision UVC dosing applications.
What wavelength bands does the AS7331 measure?
The AS7331 measures ultraviolet radiation from approximately 260 nm to 360 nm, resolved into three separated channels: UVA, UVB and UVC. According to the ams OSRAM product page, each channel uses dedicated UV-optimized photodiodes converted to an independent 24-bit digital result. This three-band split distinguishes it from UV index sensors that only report combined UVA/UVB, enabling germicidal UVC (about 254-280 nm) verification and UVB sun-exposure alerting in one device.
Where to buy AS7331-AQFM-OLGA16-LF and what is its price?
The AS7331-AQFM-OLGA16-LF is available from DigiKey, Mouser, LCSC and JLCPCB. As of 2026-10-11, LCSC lists the unit price from $10.5783 (quantity 1) though it showed out-of-stock at that date; DigiKey (part 16983751) and Mouser list the Tape and Reel variant with real-time stock. Indicative XAIPART tier pricing as of 2026-10-11: 1 pc $10.58, 100 pcs $8.57, 1000 pcs $6.94. Confirm live stock before ordering.
What is the best drop-in replacement for AS7331-AQFM-OLGA16-LF?
There is currently no true pin-to-pin drop-in replacement from another manufacturer for the AS7331 in the 3.65 x 2.6 mm OLGA-16 footprint. The closest functional substitute is the same AS7331 family from ams OSRAM (e.g., AS7331-AQFM base ordering code). Cross-brand parts such as the LTR390 (UV + ambient light, different package and footprint) or VEML6075 are functional alternatives only and require PCB rework, so they are not drop-in replacements.
How do I interface the AS7331 with a microcontroller?
Connect the AS7331 to a microcontroller via its I2C interface: SDA and SCL lines with pull-up resistors (typically 4.7 kOhm to the 2.7-3.6 V rail), plus decoupling of the supply with a 100 nF ceramic capacitor close to the pin. The sensor supports continuous and triggered measurement modes. Driver libraries already exist for popular boards, as shown by the SparkFun Qwiic breakout and Adafruit AS7331 breakout (product 6476), which expose UVA, UVB and UVC readings over I2C.
Can AS7331 be used for UVC germicidal lamp monitoring?
Yes. The AS7331 is one of few compact digital sensors with a dedicated UVC channel reaching approximately 260 nm, according to DigiKey spectral classification (260 nm to 360 nm). This makes it suitable for verifying germicidal lamp output in disinfection cabinets and UV-C sterilizer enclosures. For dose verification, program the gain and conversion time to place lamp irradiance in the upper half of the 24-bit range, and remember that UVC photodiode degradation and enclosure optics affect absolute accuracy, so periodic calibration against a reference radiometer is recommended.
Is the AS7331 suitable for wearable UV index devices?
Yes. The AS7331's low-power architecture with four operating modes, including continuous and triggered measurement, supports battery-powered wearable UV index monitors that mainly need UVA and UVB readings. Its 3.65 x 2.6 mm OLGA-16 footprint and low noise allow integration under a small translucent window. Firmware typically samples periodically in triggered mode, computes a UV index from the UVA/UVB channels, and wakes the host only when thresholds are exceeded, extending battery life versus continuous polling.
Where can I download the AS7331-AQFM-OLGA16-LF datasheet PDF?
The AS7331 datasheet PDF is available from several official sources: LCSC hosts a free datasheet download at lcsc.com/datasheet/C20482877.pdf, and the manufacturer product page at ams-osram.com (search AS7331 Spectral UV Sensor) links the official ams OSRAM documentation. DigiKey part number 16983751 also provides datasheet links on its product page. Use the manufacturer page for the latest revision, as distributor-hosted copies may lag behind ams OSRAM revisions.
What are the key specifications of AS7331-AQFM-OLGA16-LF that engineers should know?
Key specifications: three separated UVA/UVB/UVC channels covering roughly 260 nm to 360 nm; 24-bit digital resolution per channel; I2C interface; supply voltage 2.7 V to 3.6 V; operating temperature -40 C to +105 C; OLGA-16 (16-TFLGA) package, 3.65 x 2.6 mm; four operating modes including continuous and triggered measurement; and gain, conversion time and internal clock frequency programmable to set sensitivity, full-scale range and LSB size. Source: ams OSRAM product page and LCSC/JLCPCB part data.
How do I adjust the sensitivity and full-scale range of AS7331?
Irradiance responsivity on the AS7331 is adjusted via three registers: gain, conversion time and internal clock frequency, according to the ams OSRAM product page. Increasing gain or conversion time raises sensitivity and lowers the LSB size but reduces the maximum detectable irradiance (full-scale range); shortening the conversion time extends headroom for bright UV sources such as direct sunlight or curing lamps. Firmware should select settings per band, since UVC signals from germicidal lamps are typically orders of magnitude weaker than outdoor UVA irradiance.
AS7331 vs LTR390 - which UV sensor should I choose?
Choose the AS7331 when you need separated UVA, UVB and UVC band measurements, especially UVC detection for germicidal or curing applications, because the LTR390 does not measure UVC. Choose the LTR390 when ambient light plus a rough UV index suffices and a different, more common footprint is acceptable. The AS7331 offers 24-bit resolution per channel and an industrial -40 C to +105 C range; the LTR390 is generally cheaper and easier to source. Neither is pin-compatible, so this choice must be made at PCB layout time.
When should I choose the AS7331 over other UV sensors?
Choose the AS7331 when your application depends on distinguishing UV bands: UVC lamp verification, UVB-driven sunburn alerts, agricultural UV dosing, or UV curing control. Its 24-bit per-channel resolution and programmable responsivity (gain, conversion time, clock) give it a much wider usable dynamic range than single-band UV index sensors. Also choose it for industrial temperature environments up to +105 C. If you only need a coarse UV index for consumer weather widgets and want the lowest cost, a simpler UVA/UVB sensor may be adequate.
Is the AS7331-AQFM-OLGA16-LF RoHS compliant and lead free?
Yes. According to the JLCPCB and LCSC part listings, the AS7331-AQFM-OLGA16-LF is ROHS compliant, and the LF suffix in the ordering code denotes the lead-free surface finish. As with all ams OSRAM modern optical sensors, it is intended for lead-free reflow assembly. For REACH and halogen-free status of this exact ordering code, consult the ams OSRAM product page or your distributor's compliance documentation, as those specific declarations were not stated in the retrieved distributor data.

Datos de referencia de ingeniería para AS7331-AQFM-OLGA16-LF — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the AS7331-AQFM-OLGA16-LF when your design must distinguish UVA, UVB and UVC - germicidal lamp verification, UV curing, agricultural dosing, or accurate UV index wearables - and when the industrial -40 C to +105 C range matters. Its 24-bit channels and programmable gain/conversion time cover dim indoor UVC lamps up to bright direct sun. If you only need a coarse UV index plus ambient light and want the lowest cost and easiest sourcing, a functional alternative such as the LTR390 is cheaper, but it detects no UVC and is not pin-compatible, so it requires a PCB change. There is no cross-brand drop-in in this 3.65 x 2.6 mm OLGA-16 footprint; within the ams OSRAM AS7331 family the base AS7331-AQFM ordering code is electrically and mechanically identical. Verify current stock with DigiKey, Mouser or LCSC, as availability of this newer sensor fluctuates (LCSC showed out of stock as of 2026-10-11).

Comparación con alternativas

Parámetro Este producto AS7331-AQFM
Package OLGA-16 (16-TFLGA), 3.65 x 2.6 mm OLGA-16 - same footprint
Brand ams OSRAM ams OSRAM
Spectral Range 260 nm to 360 nm (UVA/UVB/UVC) 260 nm to 360 nm
Channels 3 (UVA, UVB, UVC) 3 (UVA, UVB, UVC)
Resolution 24-bit per channel 24-bit per channel
Interface I2C I2C
Supply Voltage 2.7 V to 3.6 V 2.7 V to 3.6 V
Operating Temperature -40 C to +105 C -40 C to +105 C
Cross-Brand Pin-Compatible Alternatives None found in web data N/A (same family only)

Diferenciadores clave

  • Dedicated UVC channel reaching ~260 nm (frente a LTR390 (functional, non drop-in))
  • 24-bit per-channel resolution with programmable responsivity (frente a AS7331-AQFM (same family))
  • Industrial temperature rating (frente a VEML6075 (functional, non drop-in))

Notas de diseño

Place a 100 nF ceramic decoupling capacitor within 2 mm of the AS7331 supply pin, with an additional 1 uF bulk capacitor nearby on the 2.7-3.6 V rail. Route I2C SDA/SCL as short as practical and use 4.7 kOhm pull-ups to the sensor supply, not a 5 V rail. Because the sensor is optical, ensure the OLGA aperture has a clear, unobstructed view through a UV-transmitting window (quartz or PMMA) and keep solder-mask or conformal coating out of the optical path. Follow the footprint in the manufacturer datasheet for the 3.65 x 2.6 mm OLGA-16 land pattern.

The supply range is 2.7 V to 3.6 V - applying 5 V to the sensor rail will damage the device; level-shift the I2C bus if the host runs at 5 V. Standard cover glass blocks UVC and attenuates UVB, so specifying the window material is as important as the sensor choice. Also, UV sources degrade the photodiodes over time; in dose-critical UVC applications, budget periodic recalibration. Per the ams OSRAM product page, responsivity depends on gain, conversion time and internal clock frequency - changing any one of them changes the LSB scale, so store calibration factors per register configuration.

For battery-powered UV wearables, use the AS7331 triggered measurement mode instead of continuous mode: sample every 10-60 s, integrate the dose in firmware, and let the host MCU sleep between conversions. Estimated: sampling 1/s vs 1/60/s reduces average sensor-related energy by roughly a factor of 60, dominating the power budget since the I2C pull-up resistors often draw more average current than the sensor itself. Size pull-ups at 10 kOhm on battery designs and confirm bus rise time meets I2C timing at the chosen bus speed.

Información de cumplimiento

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

ROHS compliant per JLCPCB/LCSC part listing; LF suffix denotes lead-free finish. REACH, halogen-free and conflict-minerals declarations not stated in retrieved distributor data.

Datos verificados el: 2026-10-11 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

AS7331-AQFM-OLGA16-LF AS7331 datasheet PDF ams OSRAM AS7331 spectral UV sensor UVA UVB UVC digital sensor I2C 24-bit OLGA-16 UV sensor 3.65x2.6 AS7331 UVC germicidal lamp monitoring AS7331 vs LTR390 UV sensor AS7331 drop-in replacement equivalent AS7331-AQFM-OLGA16-LF price buy what is the operating voltage of AS7331 wearable UV index sensor module AS7331 pinout OLGA-16

Componentes & términos relacionados

ams OSRAM AS7331 AS7331-AQFM-OLGA16-LF AS7331-AQFM spectral UV sensor UVA UVB UVC I2C 24-bit ADC OLGA-16 TFLGA RoHS ambient light and spectral sensor family germicidal lamp verification UV curing UV index monitoring irradiance responsivity LTR390 VEML6075
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ