ICL7129ACPL+ - 4.5-Digit Low-Noise LCD ADC | Maxim Integrated
MPN: ICL7129ACPL+ ✓ 啟用中ICL7129ACPL+ 概覽
直接替換替代品,適用於 ICL7129ACPL+ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7129ACPL+ (相同外形與佔位) — 差異在於 Converter Type, Display Output, Mounting Type, Resolution.
ICL7129CPL
✅ 直接替換聯絡詢價
查看資料表 →ICL7129ACPL+2
✅ 直接替換📋 參考替代品(不在目錄中)
TC7129CKW
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7117CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7106CPLZ
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7129ACPL+ 最大額定值與電氣特性
| Converter Type | 4.5-digit single-chip successive-integration ADC |
| Display Output | Multiplexed LCD drivers |
| Input Configuration | High-impedance differential inputs |
| 解析度 | 4.5 digits; +/-19,999 counts |
| Conversion Technology | Successive integration |
| Polarity Detection | Automatic polarity detection |
| Ratiometric Operation | True ratiometric operation |
| Input Noise | 3 uV peak-to-peak for ICL7129A |
| Range Changing | 10:1 range-changing input |
| 封裝 | 40-pin PDIP |
| 安裝類型 | Through-hole DIP |
ICL7129ACPL+ 40-pin pdip 腳位配置指南
ICL7129ACPL+(40-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7129ACPL+.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7129ACPL+ 適用於 6 應用s: Digital Voltmeter, Digital Panel Meter, Laboratory Measurement Instrument, Process Control Monitor, Weighing Scale Display, Temperature Measurement Instrument.
Digital Voltmeter
The ICL7129ACPL+ is suited to a precision digital voltmeter because it combines a 4.5-digit ADC, high-impedance differential inputs, true ratiometric operation, and automatic polarity detection. The instrument can use the converter's multiplexed LCD drivers to present the measured voltage directly without a separate display-driver IC. Input conditioning should include protection, filtering, and a stable reference arrangement selected for the intended voltage range. The 40-pin PDIP format is convenient for laboratory prototypes, educational instruments, and repair-oriented panel-meter designs where through-hole construction and direct LCD support are priorities.
推薦
Digital Panel Meter
A digital panel meter can use the ICL7129ACPL+ to convert a conditioned sensor or process signal into a 4.5-digit LCD reading. Automatic polarity detection simplifies bipolar measurements, while the 10:1 range-changing input supports designs that need more than one measurement scale. The integrated multiplexed LCD drivers reduce the number of external interface components and help create a compact instrument front panel. Panel-meter engineers should verify the LCD segment configuration, reference voltage, input common-mode limits, and timing requirements against the manufacturer datasheet before finalizing the PCB.
推薦
Laboratory Measurement Instrument
The low-noise 4.5-digit conversion and high-impedance differential input arrangement make the ICL7129ACPL+ useful in laboratory instruments that display slow or medium-speed measurements with high resolution. The ICL7129A family's listed 3 uV peak-to-peak input noise supports precision measurement designs, although the complete signal chain must remain quiet. A practical implementation places the converter close to the input network, uses careful grounding, and selects a stable reference. The multiplexed LCD output provides a readable result without requiring a separate display interface in the basic measurement instrument.
推薦
Process Control Monitor
The ICL7129ACPL+ can serve as the measurement and display front end of a process-control monitor when the input is conditioned into the converter's supported range. Its automatic polarity detection and true ratiometric operation are useful for signals derived from sensors or bridge-like excitations, while the 4.5-digit format provides more display resolution than a 3.5-digit meter. For industrial deployment, the design must protect the analog input from transients and maintain a low-noise reference and ground arrangement. The PDIP package is appropriate for through-hole industrial control boards that require serviceability and visual operator feedback.
推薦
Weighing Scale Display
A weighing-scale display can use the ICL7129ACPL+ when the load-cell or transducer signal is amplified, filtered, and referenced with sufficient stability. The 4.5-digit resolution provides 19,999 count positions, while ratiometric operation can help maintain scale accuracy when the excitation and measurement paths share a controlled reference relationship. The LCD drivers are appropriate for a compact operator display. Calibration, input offset, gain trimming, excitation noise, and mechanical vibration remain system-level concerns; the converter should be positioned away from high-current switching paths to avoid contaminating the measurement.
推薦
Temperature Measurement Instrument
The ICL7129ACPL+ is applicable to temperature measurement instruments that use a linearized sensor signal and a local LCD. The 4.5-digit display resolution can show fractional temperature information, and the high-impedance input supports the external signal-conditioning network required by thermocouple or RTD front ends. Input bias, common-mode behavior, and leakage from the protection network should be checked because they can create errors in high-impedance temperature sensors. A stable reference and carefully routed ground plane are essential, while the multiplexed LCD output keeps the display interface compact.
推薦
推薦產品摘要
工程參考資料,適用於 ICL7129ACPL+ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ICL7129CPL | ICL7129ACPL+2 | TC7129CKW | ICL7117CPL+ | ICL7106CPLZ |
|---|---|---|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Texas Instruments | Maxim Integrated | Maxim Integrated |
| Conversion Method | Successive integration | Successive integration | Successive integration | Successive integration | Dual-slope conversion | Dual-slope conversion |
主要差異化特點
- Higher display resolution than the 3.5-digit ICL7117CPL+ (對比ICL7117CPL+)
- Integrated multiplexed LCD drive (對比ICL7106CPLZ)
- Automatic polarity detection (對比TC7129CKW)
設計說明
Place the ICL7129ACPL+ close to the analog input and reference network, and route the LCD output traces away from sensitive measurement nodes. The 40-pin PDIP footprint provides generous mechanical spacing, but the analog input pins still require short traces and a continuous ground plane. Confirm the manufacturer pin-description table before assigning LCD segment, reference, supply, and analog signal connections.
Use a low-noise reference and bypass arrangement, and filter the input signal with values appropriate to the required response time. The device uses successive integration, so system timing and input settling must be coordinated with the measurement range. Avoid sharing high-current return paths between the sensor, reference, and display subsystem, since ground movement can appear directly as measurement error.
Do not assume that every 40-pin display-driver ADC is interchangeable. The ICL7129ACPL+ requires the correct 4.5-digit LCD segment arrangement, reference configuration, polarity behavior, and timing sequence. Before using ICL7117CPL+, ICL7106CPLZ, or another listed candidate, compare every pin function and the display timing diagrams in the manufacturer documentation.
合規資訊
The trailing plus suffix is associated with Maxim Integrated lead-free ordering, but no explicit RoHS, REACH, halogen-free, or conflict-minerals statement was identified. Automotive qualification is not stated.