Renesas Electronics

ICS342MP - 200MHz Dual-Output Clock Synthesizer | Renesas

N.º de pieza: ICS342MP ✓ Activo
3.15 V to 3.45 V Vdss 8-pin SOIC, 0.154 inch body width, 3.90 mm width Package 200 MHz Speed
MOQ: 1 |

ICS342MP Descripción general

Renesas Electronics ICS342MP is a field-programmable, dual-output clock synthesizer with a maximum output frequency of 200 MHz, packaged in an 8-pin SOIC. The device accepts clock or crystal input and provides LVCMOS clock outputs through an integrated PLL architecture. Its specified 3.15 V to 3.45 V operating-supply range makes it suitable for low-voltage digital systems requiring locally generated, configurable timing signals.

A clock synthesizer is a clock and timing IC that generates, divides, multiplies, or redistributes clock signals for digital logic. Clock generators and PLL-based synthesizers belong to the broader timing-control hierarchy that includes oscillators, clock buffers, dividers, and jitter-cleaning devices. Unlike a crystal oscillator, which primarily produces a fixed reference frequency, the ICS342MP uses programmable synthesis to produce multiple related output clocks and reduce the number of separate timing components in a system.

The ICS342MP combines two configurable outputs with PLL support and a maximum frequency of 200 MHz. Its input section can operate from a clock or crystal, while its LVCMOS outputs are suited to digital logic that requires single-ended clock signals. The SOIC-8 surface-mount package also supports conventional PCB assembly and provides a compact option for communication, control, and embedded-system clock trees.

Programmability allows the output frequencies to be selected through the device configuration interface instead of requiring a separate fixed-frequency oscillator for each clock domain. This can simplify board partitioning and provide a common timing reference for related circuits. The PLL architecture is useful when the system needs an output frequency derived from a common reference, although loop behavior, output jitter, and reference stability must be evaluated during clock-tree design.

Typical uses include digital controller timing, industrial automation modules, embedded processor clock distribution, communications equipment, and general-purpose peripheral clocking. In these systems, two outputs can support related clock domains or distribute a master clock to two loads while keeping the design compact. The low-voltage supply requirement should be checked against the voltage and sequencing requirements of the logic being clocked.

The main design consideration is preserving signal integrity between the synthesizer outputs and receiving logic. Keep clock traces short, provide a continuous ground reference, use appropriate termination when required, and observe the input and output timing limits in the manufacturer datasheet. Decoupling should be placed close to the supply pin, with the value and stability requirements taken directly from the recommended application circuit.

This page consolidates the ICS342MP device identity, clock-synthesis specifications, package information, sourcing structure, and application-oriented design guidance. It also identifies the verified same-family replacement candidate and separates confirmed electrical attributes from parameters that require confirmation before schematic release or production qualification.

Alternativas directas para ICS342MP — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con ICS342MP (mismo factor de forma y huella) — difiere en Architecture, Number of Outputs, PLL, Package.

Renesas Electronics
Architecture: VersaClock clock synthesizer
Number of Outputs: 3 outputs
PLL: Yes; up to three independently configurable PLLs
Comparar con ICS342MP →

ICS343MP

✅ Sustitución directa
Renesas Electronics
📦 8-SOIC (0.154 inch, 3.90 mm width)
Field-programmable triple-output clock synthesizer · VersaClock clock synthesizer · 200 MHz · 250 kHz · 3 outputs · Yes; up to three independently configurable PLLs · Clock or crystal · LVCMOS

Consulte el precio

Ver hoja de datos →

ICS342MP Especificaciones

Device Type Clock/Frequency Synthesizer
Architecture Field-programmable dual-output PLL clock synthesizer
Maximum Output Frequency 200 MHz
Number of Circuits 1
Número de salidas 2
PLL Yes
Input Types Clock or crystal input
Tipo de salida LVCMOS
Input-to-Output Ratio 1:2
Tensión de alimentación de funcionamiento 3.15 V to 3.45 V
Encapsulado 8-pin SOIC, 0.154 inch body width, 3.90 mm width
Tipo de montaje Surface mount
Shipping Package Tube

Guía de configuración de pines de ICS342MP tube

Configuración de pines para ICS342MP (encapsulado tube). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.

Diagrama de patillaje del encapsulado tube para ICS342MP

No hay datos detallados de patillaje disponibles para ICS342MP.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

ICS342MP es adecuado para 6 aplicacións: Embedded Controller Clock Distribution, Industrial Automation Timing, Communications Module Clocking, Digital Peripheral Timing Hub, Low-Voltage Digital Logic Support, General-Purpose Synchronization.

🖥️

Embedded Controller Clock Distribution

The ICS342MP suits embedded controller designs that require two related clock outputs from a common reference. Its PLL-based architecture and 200 MHz maximum output provide flexibility for processor, peripheral, or communication clock domains, while the 3.15 V to 3.45 V supply range aligns with a 3.3 V digital rail. Place the device near the receiving logic, decouple the supply pin locally, and verify configuration timing against the system clock budget.

🏭

Industrial Automation Timing

The ICS342MP can organize timing in industrial automation modules where a controller, data converter, and communications section need related clocks. Two LVCMOS outputs can reduce discrete oscillator count, and the PLL provides a programmable path from a common clock or crystal source. Confirm the exact industrial temperature grade, output-jitter requirement, and long-term clock-accuracy budget before incorporating the device into a factory-control design.

🌐

Communications Module Clocking

The ICS342MP is suitable for communications equipment requiring configurable local clock generation rather than separate fixed-frequency sources. Its dual outputs support parallel clock trees, the PLL permits derived frequencies, and the 200 MHz ceiling accommodates demanding digital logic. For production use, route both outputs as controlled 50-ohm single-ended paths, minimize stubs, and confirm receiver setup and hold timing at the destination device.

🔧

Digital Peripheral Timing Hub

A compact control board can use the ICS342MP as a timing hub for digital peripherals that require two synchronized or related clocks. The field-programmable architecture reduces the number of fixed oscillators, while the SOIC-8 package simplifies conventional surface-mount assembly. Choose the configuration only after checking duty-cycle, phase, jitter, and frequency limits for each output; maximum frequency alone does not establish timing quality.

⚡

Low-Voltage Digital Logic Support

The ICS342MP fits low-voltage digital systems operating near 3.3 V because its specified supply range is 3.15 V to 3.45 V. It can generate LVCMOS clocks for medium-performance logic without requiring a separate high-voltage clock source. Keep the device on a stable low-noise supply, place the required bypass capacitor at the power pin, and verify absolute maximum voltage limits when another rail shares the board.

🧩

General-Purpose Synchronization

The ICS342MP can serve general-purpose synchronization when multiple digital subsystems need a common programmable clock source. Its clock-or-crystal input and dual LVCMOS outputs provide flexible distribution in a compact SOIC-8 package. The designer should still establish the reference accuracy, PLL configuration, output phase relationship, and worst-case jitter in the system timing budget rather than assuming equal clocks are automatically suitable for every interface.

What is the ICS342MP?
The Renesas Electronics ICS342MP is a field-programmable, dual-output clock synthesizer based on a PLL. According to the manufacturer datasheet, it accepts a clock or crystal input, produces LVCMOS outputs, and reaches a maximum output frequency of 200 MHz. The 8-pin SOIC package makes it appropriate for compact digital systems that need configurable timing from a common reference.
What is the operating voltage of the ICS342MP?
The ICS342MP operates from 3.15 V to 3.45 V. According to the Renesas Electronics datasheet, this is the device's specified supply-voltage range, giving a nominal 3.3 V operating point. Confirm the minimum and maximum voltage at every temperature and load condition before using the part with a rail whose tolerance could exceed those boundaries.
What is the maximum output frequency of the ICS342MP?
The ICS342MP supports a maximum output frequency of 200 MHz. According to the Renesas Electronics datasheet, the device uses PLL-based dual-output synthesis and provides LVCMOS output signals. The 200 MHz figure is a maximum device rating; the actual usable frequency also depends on output configuration, reference stability, timing margin, load, and PCB signal integrity.
Where can I download the ICS342MP datasheet PDF?
The official ICS342MP datasheet is available from the Renesas Electronics document page at https://www.renesas.com/en/document/dst/342-datasheet?language=en. Use that manufacturer document for the authoritative pin-description table, electrical characteristics, programming procedure, timing limits, and recommended application circuit. Third-party copies can assist with searching, but the Renesas document should control design release.
Where can I find the ICS342MP pinout?
The ICS342MP pinout is documented in the pin-description table of the Renesas Electronics 342 datasheet. The device is specified in an 8-pin SOIC package, but individual pin numbers and signal names are not reproduced on this page because the manufacturer pin table was not exposed in the indexed material. Use the official datasheet before assigning PCB nets or programming interface signals.
What can replace the ICS342MP?
The Renesas Electronics ICS343MP is the closest same-family drop-in candidate identified for the ICS342MP because both are listed as 200 MHz clock or frequency synthesizer ICs in 8-pin SOIC packages. Its detailed pin mapping and configuration requirements must still be checked against the ICS342MP datasheet. No verified cross-brand replacement meeting both package and pin-compatibility requirements was identified.
Is the ICS343MP the same as the ICS342MP?
The ICS343MP is not established as an identical functional replacement for the ICS342MP, although it shares the 200 MHz maximum-frequency class and 8-pin SOIC format. According to the manufacturer listings for both devices, each is a clock or frequency synthesizer. Verify pin names, PLL programming, supply limits, output behavior, and timing requirements before treating it as a drop-in replacement.
ICS342MP vs ICS343MP - which one is better for a 200 MHz design?
The ICS342MP is the better-documented choice when a design specifically calls for the Renesas 342 family, while the ICS343MP may suit a design that can use the 343 family's configuration and timing characteristics. Both are listed with a 200 MHz maximum and an 8-pin SOIC package. The decisive comparison is the manufacturer datasheet's pin mapping, output configuration, jitter, reference-input range, and lifecycle requirements.
When should I choose the ICS342MP over the ICS343MP?
Choose the ICS342MP when the schematic, firmware, and layout have already been designed around the 342 family's programming interface and timing behavior. It provides a dual-output PLL clock synthesizer with a 200 MHz maximum output in an 8-pin SOIC. Choose the ICS343MP only after confirming that its pin configuration, electrical limits, and programming sequence preserve the intended system operation.
Is the ICS342MP suitable for industrial and embedded systems?
The ICS342MP can be suitable for industrial and embedded clock trees when its 3.15 V to 3.45 V supply range, 200 MHz maximum frequency, and temperature specification satisfy the system requirements. Its dual LVCMOS outputs can generate related clocks for controller logic and peripherals. Industrial qualification should be confirmed from the ordered part's rated temperature range and compliance documentation.
Where can I buy the ICS342MP and check its price?
Use the Request a Quote form on this page to request the current ICS342MP price, stock position, and lead time. The request should state the exact MPN ICS342MP, required quantity, and preferred tube packaging. Commercial terms and availability can change, so use the quote response for the current purchasing decision instead of relying on an unrefreshed listing.
What is the lead time for the ICS342MP?
The current lead time must be obtained through the Request a Quote form on this page. The verified product material identifies the ICS342MP as a Renesas Electronics clock synthesizer supplied in tube packaging, but it does not establish a production allocation or current delivery schedule. Include your required quantity and target date so the supplier can return an actionable commitment.
Is the ICS342MP in stock?
Current stock should be confirmed through the Request a Quote form on this page. Some distributor listings identify inventory for ICS342MP, but stock quantities are time-sensitive and do not represent a guaranteed allocation for a production order. State the required quantity, tube-packaging preference, and target receiving date when requesting a firm availability and lead-time response.
What are the key specifications engineers should know about the ICS342MP?
The key ICS342MP specifications are its 200 MHz maximum output frequency, dual-output PLL architecture, clock-or-crystal input, LVCMOS output type, and 3.15 V to 3.45 V operating-supply range. According to the Renesas Electronics datasheet, the device is a field-programmable clock synthesizer in an 8-pin SOIC. Jitter, temperature, and detailed timing limits should be taken from that document.
Does the ICS342MP comply with RoHS and REACH?
The RoHS and REACH status of the exact ICS342MP orderable part must be confirmed from its current material declaration or manufacturer compliance documentation. Do not infer compliance from the package type, distributor category, or the absence of a restricted-substance notice. Request the applicable environmental declaration before release for RoHS-controlled or REACH-regulated equipment.

Datos de referencia de ingeniería para ICS342MP — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the ICS342MP when the design requires a Renesas dual-output PLL clock synthesizer with clock or crystal input, LVCMOS outputs, a 200 MHz maximum frequency, and operation from 3.15 V to 3.45 V in an 8-pin SOIC package. It is particularly suitable when two related clock domains can reduce oscillator count or board partitioning. Consider the ICS343MP when its manufacturer documentation shows equivalent pin behavior and a better match for the required output configuration; both parts are listed at 200 MHz and in the same 8-SOIC size class. Do not approve a replacement solely from the package and headline frequency. Check pin names, programming sequence, supply limits, output timing, jitter, and lifecycle status against the official datasheets. No cross-brand part is recommended without documented pin compatibility and equivalent electrical timing.

Comparación con alternativas

Parámetro Este producto ICS343MP
Brand Renesas Electronics Renesas Electronics
Package 8-SOIC (0.154 inch, 3.90 mm width) 8-SOIC (0.154 inch, 3.90 mm width)
Device Type Clock/Frequency Synthesizer Clock/Frequency Synthesizer
Maximum Output Frequency 200 MHz 200 MHz

Diferenciadores clave

  • Dual-output programmable clock synthesis (frente a ICS343MP)
  • 200 MHz maximum clock capability (frente a ICS343MP)
  • Clock-or-crystal reference flexibility (frente a ICS343MP)
  • LVCMOS output integration (frente a ICS343MP)

Notas de diseño

Route the reference and output clock traces as short, continuous paths on a solid reference plane. Avoid long stubs, test pads, and unnecessary layer transitions because they can degrade edge quality and introduce coupling into a sensitive digital clock tree. Keep the crystal, if used, close to its assigned input pins and follow the manufacturer's recommended grounding and component-placement arrangement.

Treat each LVCMOS output as a controlled transmission-line path when the trace is long, the load is capacitive, or the clock edge rate is fast. Use a continuous ground reference, maintain a practical separation from switching power nodes, and terminate according to the receiver's input characteristics. Confirm eye margin and timing behavior with an oscilloscope in the assembled design.

Do not select the ICS342MP solely from its 200 MHz maximum frequency. Verify the programmed output range, output duty-cycle limits, reference-input conditions, startup behavior, and timing uncertainty required by the receiving logic. Also confirm that the board's 3.3 V rail remains within 3.15 V to 3.45 V under load; a nominally correct supply can still exceed the permitted operating range.

Place the supply bypass capacitor immediately beside the power pin and connect it with a short return path to the ground reference. Separate the clock circuitry from noisy switching nodes and maintain short output routes. Before releasing the layout, compare every programming, reference, ground, and output connection against the pin-description table and recommended application circuit in the official Renesas datasheet.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

Exact-part environmental and material compliance declarations were not identified. Obtain the current manufacturer declarations before releasing the component into a regulated product.

Datos verificados el: 2026-11-05 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

ICS342MP datasheet ICS342MP pinout ICS342MP datasheet pdf ICS342MP specifications ICS342MP 200MHz clock synthesizer ICS342MP SOIC-8 ICS342MP equivalent ICS342MP replacement ICS342MP vs ICS343MP Renesas ICS342MP ICS342MP price ICS342MP stock and lead time

Componentes & términos relacionados

Renesas Electronics ICS342MP ICS343MP clock synthesizer field-programmable dual-output clock synthesizer PLL phase-locked loop LVCMOS clock generator clock and timing IC timing-control IC oscillator 200 MHz maximum output frequency 3.15 V to 3.45 V operating supply 8-pin SOIC SOIC package family surface-mount package crystal input clock input output jitter digital clock tree industrial automation embedded controller communications equipment field programming
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ