Renesas Electronics

ICS343MP - 200MHz Triple-Output Clock Synthesizer | Renesas

N.º de pieza: ICS343MP ✓ Activo
8-SOIC Package 200 MHz Speed
MOQ: 1 |

ICS343MP Descripción general

Renesas Electronics ICS343MP is a field-programmable, triple-output clock synthesizer based on the VersaClock architecture. It generates three independently programmable output clocks, reaches a maximum output frequency of 200 MHz, and accepts either a crystal or external clock input. The device is packaged in an 8-pin SOIC measuring 3.90 mm wide, making it suitable for compact communications, industrial control, test-and-measurement, and embedded timing systems.

A clock synthesizer is a timing IC that accepts a reference frequency and uses one or more phase-locked loops to produce stable, independently configurable clock outputs. The ICS343 belongs to the clock generator and PLL hierarchy within the broader clock and timing IC category. Its three-output architecture can replace multiple discrete oscillators or divider networks when a board requires several related frequencies from one reference source.

The ICS343MP provides three programmable outputs, PLL-based frequency synthesis, LVCMOS output signaling, and maximum frequency operation of 200 MHz. Separate output divide values from 2 through 20 allow the output clock banks to support widely different frequencies from the same reference. These features make the device useful where a system needs flexible clock partitioning without allocating a separate synthesizer for every rail.

Its architecture supports low-cost field-programmable clock generation from a crystal or clock source. Independent output programming is particularly valuable in mixed-signal, communications, and data-conversion systems where the processor, serial interface, and peripheral blocks may not require the same frequency. The 8-SOIC package also offers a familiar surface-mount footprint for designs that must support external oscillators or frequency dividers.

Typical applications include processor and interface clocking, communications modules, industrial automation equipment, test and measurement instrumentation, and embedded control systems. In each case, the synthesizer can centralize reference distribution while allowing output frequencies and divide ratios to be selected during configuration. The result is a smaller clock tree and potentially fewer discrete timing components.

Designers should evaluate loop bandwidth, output jitter, supply requirements, and board-level noise using the manufacturer's application guidance before high-volume release. Reference-crystal layout, grounding, and output-routing practices are especially important in low-jitter systems. Because output-edge quality depends on the complete clock tree, PCB trace geometry and supply decoupling should be evaluated together with the programmed divider and PLL settings.

This product page consolidates the device classification, functional characteristics, sourcing information, and engineering-oriented usage guidance. It also distinguishes the verified ICS343MP configuration from related suffix variants and identifies the limitations of the available replacement records, helping engineers make a more informed drop-in decision without treating broadly similar clock ICs as electrically interchangeable.

Alternativas directas para ICS343MP — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con ICS343MP (mismo factor de forma y huella) — difiere en Architecture, Number of Outputs, PLL, Package.

Renesas Electronics
Architecture: Field-programmable dual-output PLL clock synthesizer
Number of Outputs: 2
PLL: Yes
Comparar con ICS343MP →

343MPLF

✅ Sustitución directa
📦 8-SOIC
Same 200 MHz VersaClock function and 8-SOIC footprint; the published comparison identifies consistent performance, terminals, and package with no circuit modification required.

📋 Alternativa de referencia (no en el catálogo)

343MIPLF

✅ Sustitución directa
📦 8-SOIC
Same 200 MHz VersaClock function and 8-SOIC footprint; suffix-specific qualification and ordering conditions must be checked before substitution.

📋 Alternativa de referencia (no en el catálogo)

ICS343MP Especificaciones

Product Type Field-programmable triple-output clock synthesizer
Architecture VersaClock clock synthesizer
Maximum Output Frequency 200 MHz
Minimum Output Frequency 250 kHz
Número de salidas 3 outputs
PLL Yes; up to three independently configurable PLLs
Input Type Clock or crystal
Output Logic Type LVCMOS
Output Divide Range 2 to 20
Encapsulado 8-SOIC
Package Width 3.90 mm
Tipo de montaje Surface mount
RoHS Compliance unknown
REACH Compliance unknown
AEC-Q100 Qualification not_applicable

Guía de configuración de pines de ICS343MP 3.90 mm

Configuración de pines para ICS343MP (encapsulado 3.90 mm). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.

Diagrama de patillaje del encapsulado 3.90 mm para ICS343MP

No hay datos detallados de patillaje disponibles para ICS343MP.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

ICS343MP es adecuado para 6 aplicacións: Communications Module Clocking, Processor and Peripheral Clock Distribution, Industrial Automation Timing, Test and Measurement Instrumentation, Data Acquisition and Conversion Systems, Network and Edge Equipment.

🌐

Communications Module Clocking

The ICS343MP fits communications modules that need several related clocks but have limited board area. Its three independently programmable outputs can derive clocks for a processor, serial interface, and peripheral block from one crystal or external reference, reducing the number of separate oscillator packages. The 200 MHz maximum output frequency supports higher-speed digital interfaces, while programmable divide values from 2 through 20 allow widely separated output rates. Designers should minimize reference-loop area, maintain a clean supply rail, and route each LVCMOS clock away from switching-node return currents.

🖥️

Processor and Peripheral Clock Distribution

The ICS343MP is appropriate for embedded systems in which processor, bus, and peripheral timing do not all use the same frequency. Three independently programmable outputs replace a collection of oscillators and dividers, while the 8-SOIC package supports compact surface-mount layouts. The clock synthesizer can accept either a crystal or an external clock source, allowing the design to follow the system's reference architecture. Validate PLL bandwidth, output-edge requirements, and the final divide settings against the manufacturer's datasheet before production use.

🏭

Industrial Automation Timing

Industrial automation equipment often combines controller logic, communication circuitry, and data-conversion blocks that require coordinated clocking. The ICS343MP generates up to three programmable outputs from one reference and covers frequencies from 250 kHz to 200 MHz, allowing a compact controller design to serve several timing domains. In machinery, the device should be paired with careful grounding, short reference routing, and supply filtering. Its industrial suitability must be confirmed from the ordering information and temperature rating rather than assumed from the function alone.

🔧

Test and Measurement Instrumentation

Test and measurement instruments benefit from multiple internally related clocks for acquisition, conversion, control, and communication sections. The ICS343MP's triple-output VersaClock architecture can provide independently programmed frequencies up to 200 MHz from one stable reference, simplifying synchronization across instrument subsystems. For sensitive measurements, evaluate output jitter and reference quality using the manufacturer's data, keep supply decoupling close to the device, and use controlled impedance routing to avoid degradation of clock edges.

📺

Data Acquisition and Conversion Systems

Data-acquisition systems may require a sampling clock, interface clock, and processor reference derived from a common source. The ICS343MP can supply three programmable LVCMOS outputs and supports output divide ratios from 2 through 20, making it useful when the converter and digital sections need related but nonidentical rates. Use short, direct clock traces and maintain a continuous ground reference beneath the device. Confirm output jitter, supply voltage, and temperature limits against the system requirements before selecting the exact suffix.

🧩

Network and Edge Equipment

Edge gateways and compact network equipment often need several clock domains for a communications processor, memory interface, and status peripherals. The ICS343MP consolidates these requirements into an 8-SOIC clock synthesizer capable of three independently programmed outputs and a maximum frequency of 200 MHz. This can reduce oscillator count and simplify clock-tree documentation. In compact systems, pay particular attention to reference-crystal placement, power-supply return paths, and isolation from Ethernet or radio-interface switching circuitry to protect timing quality.

What is the ICS343MP?
The ICS343MP is a field-programmable, triple-output clock synthesizer that can generate frequencies from 250 kHz to 200 MHz. According to the manufacturer datasheet, its VersaClock architecture uses up to three independently configurable PLLs and accepts either a crystal or external clock input. The device is offered by Renesas Electronics in an 8-SOIC package and is intended for systems requiring several programmable clocks from one reference source.
What are the key specifications of ICS343MP that engineers should know?
The ICS343MP is a 200 MHz maximum-frequency, triple-output PLL clock synthesizer with LVCMOS outputs and an 8-SOIC package. According to the manufacturer datasheet, each output can be programmed independently, while separate output divide values from 2 through 20 support substantially different clock frequencies. The device can use a crystal or clock input, making it suitable for processor, interface, communications, and test-system clock trees.
What is the maximum frequency of ICS343MP?
The ICS343MP has a maximum output frequency of 200 MHz. According to the manufacturer datasheet, the synthesizer can generate three output frequencies over a range of 250 kHz to 200 MHz using up to three independently configurable PLLs. This range supports both low-speed peripheral clocks and higher-frequency digital interface or processor timing requirements.
How many clock outputs does ICS343MP provide?
The ICS343MP provides three independently programmable clock outputs. According to the manufacturer datasheet, up to three PLLs can be configured and the output banks support separate divide values from 2 through 20. This allows one reference source to serve clock domains with different frequency relationships while reducing the number of separate oscillators required on the board.
Can ICS343MP operate from an external clock or crystal?
The ICS343MP accepts either an external clock or a crystal as its input source. According to the manufacturer datasheet, the input feeds the programmable VersaClock synthesis architecture, which drives up to three outputs. When using a crystal, follow the specified load-capacitance and layout guidance; when using an external clock, validate frequency, amplitude, and jitter at the input pin.
Where can I download the ICS343MP datasheet PDF?
The ICS343MP datasheet PDF is available through the datasheet link on this page, with the manufacturer document also indexed by electronic component documentation sites. The document describes the triple-output VersaClock architecture, programmable frequency range, PLL configuration, and application information. Check the revision and ordering information in the PDF before applying its circuit guidance to a production design.
Where can I find the ICS343MP pinout?
The ICS343MP pinout is documented in the manufacturer datasheet and uses an 8-SOIC package. Use the pin-description table and package drawing in that document when assigning reference, ground, supply, and programmable clock-output connections. The component is listed as an 8-SOIC, 3.90 mm-wide device, so PCB land patterns and pin numbering must follow the SOIC-8 outline exactly.
What is the difference between ICS343MP and 343MPLF?
The 343MPLF is a closely related 8-SOIC suffix variant of the ICS343 family, and a published comparison identifies it as a complete replacement with consistent terminals, package, performance, and functional characteristics. It is therefore a same-package drop-in candidate for ICS343MP. Confirm programming requirements and current ordering status before production release because suffix options can encode packing or temperature distinctions.
What is the best drop-in replacement for ICS343MP?
The best supported drop-in candidate is the Renesas Electronics 343MPLF because its published comparison with ICS343MP identifies matching 8-SOIC terminals, package, performance, and functional characteristics. A related 343MIPLF variant also appears in the same replacement listing. Verify the exact suffix, programming method, lifecycle status, and supply availability against the manufacturer datasheet before substituting either part.
Can 343MPLF replace ICS343MP without PCB changes?
Yes, the published cross-reference identifies 343MPLF as a complete replacement for ICS343MP, with consistent terminals and package and no existing-circuit modification required. Both use the 8-SOIC footprint. Even so, confirm pin definitions, supply limits, programming configuration, and ordering details in the manufacturer documentation before approving the substitution.
When should I choose ICS343MP over 343MPLF?
Choose ICS343MP when 343MPLF does not match the required suffix, qualification, temperature grade, packing method, or current lifecycle condition. Both are presented as 8-SOIC VersaClock devices with consistent performance and terminal arrangements. For an existing ICS343MP PCB, 343MPLF is attractive as a drop-in option, but the original ordering code remains preferable when its full configuration exactly matches the design requirements.
Is ICS343MP suitable for communications and industrial clock trees?
The ICS343MP is suitable for communications and industrial clock trees when its frequency range and programmed PLL performance match the system. Its three outputs can serve multiple clock domains, and its 200 MHz maximum frequency covers common digital timing needs. Validate jitter, supply range, temperature grade, and output-routing requirements against the manufacturer datasheet before deploying it in a safety- or mission-critical system.
What design considerations matter for an ICS343MP clock tree?
The most important considerations are reference-source stability, PLL configuration, output jitter, supply decoupling, grounding, and clock routing. According to the manufacturer datasheet, the ICS343MP accepts a crystal or external clock and provides programmable LVCMOS outputs. Keep the reference path short, use the prescribed decoupling network, and route clock outputs away from high-current switching nodes to preserve edge quality.
How do I price and procure ICS343MP?
Use the Request a Quote form on this page for current pricing, stock status, minimum order quantity, and lead time for the ICS343MP. Current commercial terms can change with inventory, suffix configuration, and order quantity, so request a quote against the exact MPN. The visible structured pricing area should be used only when a current qualifying listing is present.
Is ICS343MP currently available for purchase?
The ICS343MP is presented as an active Renesas Electronics clock synthesizer, but exact stock and delivery timing should be confirmed through the Request a Quote form on this page. Include the required quantity, target reel or tube format, and any qualification requirements in the request. This avoids treating general catalog activity as a guarantee of immediate stock.

Datos de referencia de ingeniería para ICS343MP — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the ICS343MP when a design requires three independently programmable clocks, a maximum frequency of 200 MHz, and crystal or external-clock input in an 8-SOIC footprint. Its VersaClock architecture is particularly useful when processor, communications, and peripheral domains need related but nonidentical frequencies from one reference. The 343MPLF is the strongest supported drop-in candidate because a published comparison identifies matching performance, terminals, and package; it is attractive when its suffix-specific qualification, temperature grade, and packing satisfy the product requirements. The 343MIPLF is another same-footprint family candidate but needs closer ordering-code review. In every case, confirm supply voltage, jitter, temperature range, programming method, and lifecycle status against the manufacturer datasheet before approving a replacement.

Comparación con alternativas

Parámetro Este producto 343MPLF 343MIPLF
Brand Renesas Electronics Renesas Electronics Renesas Electronics
Package 8-SOIC 8-SOIC - same 8-SOIC - same
Product Type Triple-output field-programmable clock synthesizer VersaClock clock synthesizer VersaClock clock synthesizer
Maximum Output Frequency 200 MHz 200 MHz 200 MHz
Minimum Output Frequency 250 kHz 250 kHz 250 kHz
Number of Outputs 3 outputs 3 outputs 3 outputs
Output Logic LVCMOS LVCMOS LVCMOS
Output Divide Range 2 to 20 2 to 20 2 to 20
Input Type Clock or crystal Clock or crystal Clock or crystal

Diferenciadores clave

  • Three independently programmable clock outputs (frente a 343MPLF)
  • Compact 8-SOIC implementation (frente a 343MIPLF)
  • Single-reference multi-clock architecture (frente a 343MPLF)

Notas de diseño

Place the ICS343MP close to the crystal or external clock source and keep the reference path short. Follow the manufacturer's reference-circuit layout, including the specified load capacitance and grounding arrangement. A long or poorly terminated reference path can degrade phase noise and make output behavior less predictable across PCB revisions.

Route each LVCMOS clock output as a controlled-impedance transmission line when its endpoint, length, or edge rate requires it. Avoid routing clock nets beneath switching regulators, inductors, or other high-current paths, and provide a continuous ground reference beneath the traces. Confirm the receiver's input capacitance and the PCB stack-up before finalizing output termination.

Place the required input and output capacitors close to their associated device pins and maintain a low-impedance ground return. Program the PLL and divider values only after confirming that the selected reference frequency satisfies the synthesizer's operating conditions. Validate supply tolerance, startup behavior, and clock outputs across the full intended temperature range.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

No explicit compliance declarations for RoHS, REACH, lead-free construction, halogen-free construction, or conflict-minerals reporting were identified. The device is a clock and timing IC rather than an automotive-qualified AEC-Q100 product unless a specific ordering option states otherwise.

Datos verificados el: 2026-11-05 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

ICS343MP datasheet ICS343MP datasheet pdf ICS343MP pinout ICS343MP specifications ICS343MP 200MHz clock synthesizer ICS343MP triple output PLL ICS343MP 8-SOIC footprint ICS343MP equivalent ICS343MP replacement ICS343MP vs 343MPLF Renesas ICS343MP ICS343MP price

Componentes & términos relacionados

Renesas Electronics ICS343MP 343MPLF 343MIPLF VersaClock clock synthesizer clock generator phase-locked loop PLL LVCMOS triple-output clock field-programmable clock 8-SOIC SOIC package surface-mount package 250 kHz 200 MHz output divide ratio crystal oscillator external clock clock and timing IC communications equipment industrial automation test and measurement
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ