Texas Instruments

INA122P - 36V Micropower Instrumentation Amplifier | TI

N.º de pieza: INA122P ✓ Activo
En stock Se envía en 1-3 días hábiles
2.2 V to 36 V Vdss 60 µA Id 8-pin plastic DIP (8-PDIP) Package
Contacto para consultar precios
MOQ: 1 |
Precio actualizado: 2026-10-21
Precios por volumen
Cant. Precio unitario Total
1 $0 $0,00
10 $0 $0,00
100 $0 $0,00
500 $0 $0,00
1.000 $0 $0,00
ℹ️ Todos los precios están en USD

INA122P Descripción general

The Texas Instruments INA122P is a precision, low-noise instrumentation amplifier for accurate differential signal acquisition, featuring 60 µA quiescent current, operation from 2.2 V to 36 V, and an 8-pin plastic DIP package. Its two-op-amp architecture supports single- and dual-supply operation, making it suitable for portable medical equipment, data-acquisition systems, and low-level transducer interfaces. The device is designed for accurate measurement of small differential signals while maintaining low power consumption.

An instrumentation amplifier is a specialized amplifier category that measures the voltage difference between two input signals while rejecting common-mode noise. INA122P belongs to the broader hierarchy of instrumentation amplifier, differential amplifier, amplifier IC, and analog signal-conditioning IC. This position allows the device to sit between a sensor and an ADC or measurement system, where weak sensor outputs must be amplified without allowing the common-mode voltage to corrupt the result.

Key features include a 60 µA low quiescent current, single-supply operation up to 36 V, dual-supply operation up to ±18 V, a common-mode range extending to V− − 0.1 V, and rail-to-rail output swing. The verified manufacturer data also identifies low offset voltage, low offset drift, and low noise as important characteristics for precision measurements. These features support battery-powered and portable systems where power consumption, input range, and signal fidelity are primary design constraints.

The two-op-amp design provides accurate, low-noise differential acquisition in a single integrated circuit. Unlike a general-purpose op-amp used with a manually matched resistor network, the INA122P integrates the differential signal-conditioning function and is intended for applications such as bridges, load cells, thermocouples, and other low-level transducers. The common-mode and output-swing characteristics allow the amplifier to operate near the lower supply rail, which is useful in single-supply sensor systems.

Typical applications include portable medical monitoring, industrial data acquisition, battery-powered instrumentation, bridge and load-cell signal conditioning, thermocouple interfaces, and low-level sensor measurement. In each case, the device can amplify a differential sensor signal while its low quiescent current helps preserve battery life. Designers should still verify input common-mode limits, output swing, gain configuration, supply range, and external resistor or capacitor requirements against the manufacturer datasheet.

A key design consideration is maintaining adequate supply headroom and correct gain-setting components. Input and output signal ranges must remain within the specified common-mode and swing limits at every temperature and load condition. Place the device close to the sensor source when possible to reduce noise pickup, and follow the manufacturer datasheet for decoupling, gain resistor selection, grounding, and input protection.

This page combines the verified Texas Instruments datasheet information, distributor listing data, and application-oriented engineering guidance for engineers evaluating the INA122P. It also distinguishes exact INA122 family packaging variants from unverified substitutes, helping PCB designers avoid assuming that different packages or amplifier families are drop-in compatible.

Alternativas directas para INA122P — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con INA122P (mismo factor de forma y huella) — difiere en Application Category, Common-Mode Range, Mounting Type, Output Swing, Package.

Texas Instruments
Application Category: Portable medical and data acquisition
Common-Mode Range: (V−) − 0.1 V
Mounting Type: Surface mount
Comparar con INA122P →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

INA122PA

✅ Sustitución directa
📦 8-PDIP
Same INA122 family and 8-pin DIP package; verified data indicates no measurable primary parameter difference, but exact ordering suffix and pin mapping should be checked.

📋 Alternativa de referencia (no en el catálogo)

INA122U

✅ Sustitución directa
Texas Instruments
📦 8-PDIP
Precision instrumentation amplifier · Two-op-amp design · 2.2 V to 36 V · 2.2 V to 36 V · ±18 V · 60 µA typical · (V−) − 0.1 V · Rail-to-rail output swing

✓ En stock

Consulte el precio

Ver hoja de datos →

INA122PA

✅ Sustitución directa
📦 8-PDIP
Same family package and reported equivalent performance; no quantified difference is available in the supplied comparison snippet.

📋 Alternativa de referencia (no en el catálogo)

INA126PA

✅ Sustitución directa
📦 8-PDIP
Potential same-package family alternative, but the supplied comparison does not establish identical pinout or full parameter matching; verify before substitution.

📋 Alternativa de referencia (no en el catálogo)

INA122P Valores máximos y características eléctricas

Product Type Precision instrumentation amplifier
Architecture Two-op-amp design
Corriente en reposo 60 µA
Supply Voltage Range 2.2 V to 36 V
Dual-Supply Range ±18 V
Common-Mode Range V− − 0.1 V
Output Swing Rail-to-rail
Low Offset Voltage 250 µV maximum
Low Offset Drift 3 µV/°C maximum
Circuit Count 1 circuit
Encapsulado 8-pin plastic DIP (8-PDIP)
Tipo de montaje Through-hole
Temperatura de funcionamiento −40 °C to +85 °C
Application Category Portable medical and data-acquisition instrumentation
Signal Type Differential
Estado RoHS unknown
REACH Status unknown
AEC-Q100 Qualification unknown

Configuración de pines de INA122P

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
Pin 1 RG — Gain-setting resistor connection; verify exact function in the manufacturer datasheet
Pin 2 IN− — Inverting differential input
Pin 3 IN+ — Non-inverting differential input
Pin 4 V− — Negative supply or ground in single-supply operation
Pin 5 RG — Gain-setting resistor connection; verify exact function in the manufacturer datasheet
Pin 6 OUT — Amplified differential output
Pin 7 VS — Positive supply
Pin 8 REF — Reference input for output-voltage operation; verify exact function in the manufacturer datasheet

Aplicaciones típicas

INA122P es adecuado para 6 aplicacións: Portable Medical Instrumentation, Load-Cell Signal Conditioning, Battery-Powered Data Acquisition, Thermocouple and Low-Level Sensor Interface, Bridge-Sensor Measurement, Industrial Sensor Interface.

💊

Portable Medical Instrumentation

INA122P fits portable medical measurement systems that must acquire weak differential sensor signals while keeping power consumption low. Its verified 60 µA quiescent current is valuable when the instrument operates from a battery, and the 2.2 V to 36 V supply range allows integration across different portable-system rails. The amplifier can condition pressure, temperature, or other transducer outputs before an ADC. Designers should verify common-mode voltage, output swing, isolation requirements, and medical-product validation procedures.

🏭

Load-Cell Signal Conditioning

INA122P is suited to load-cell and strain-gauge front ends that produce small differential signals in the presence of larger common-mode voltages. Its instrumentation-amplifier architecture is intended for accurate differential acquisition, while the 60 µA quiescent current supports low-power portable weighing systems. Use the device ahead of an ADC or measurement converter and confirm excitation voltage, input common-mode limits, gain setting, and output range. PCB layout should keep sensor traces short and away from switching circuitry.

🔋

Battery-Powered Data Acquisition

The INA122P supports compact data-acquisition systems where every milliamp of supply current can affect battery life. Its 60 µA quiescent current helps the analog front end operate continuously, and its supply range from 2.2 V to 36 V provides flexibility for single-supply and higher-voltage arrangements. The device can amplify sensor differences before conversion or transmission. Confirm actual power consumption across operating mode, sensor impedance, gain components, and downstream circuitry, and validate common-mode range for every input condition.

🌡️

Thermocouple and Low-Level Sensor Interface

INA122P can serve as the differential input stage for thermocouples and other low-level sensors whose useful signal is much smaller than the surrounding common-mode voltage. Its low offset voltage, low offset drift, and low-noise positioning are important when preserving small sensor variations. The amplifier’s verified common-mode limit and rail-to-rail output swing determine how closely the sensor may operate to the supply rails. Use appropriate input protection, cold-junction compensation where required, and grounding techniques designed for the thermocouple itself.

📐

Bridge-Sensor Measurement

The INA122P is appropriate for resistive bridge sensors where the measurement depends on a small differential voltage generated by a change in resistance or pressure. Its instrumentation-amplifier function rejects common-mode excitation and provides a clean differential input stage for downstream conversion. The device’s 2.2 V to 36 V supply capability supports flexible bridge excitation architectures. Confirm the bridge excitation voltage, sensor output range, gain network, input protection, and ADC input range before production release.

🏭

Industrial Sensor Interface

INA122P can be used in industrial sensor interfaces when low power, differential measurement, and flexible supply operation are important. Its 60 µA quiescent current is useful for remote or portable instrumentation, while the wide supply range supports both compact low-voltage systems and higher-voltage industrial front ends. The common-mode specification must be checked against the sensor and excitation circuit, particularly when long cables or grounding differences are present. Add filtering and protection as required by the application environment.

What is the operating voltage of INA122P?
The INA122P operates from 2.2 V to 36 V according to the Texas Instruments INA122 datasheet. In dual-supply operation, the specified range extends to ±18 V. This makes the device suitable for portable single-supply systems as well as higher-voltage instrumentation using bipolar rails. The applicable supply arrangement must still satisfy the input common-mode and output-swing limits.
How much quiescent current does INA122P use?
The INA122P has a low quiescent current of 60 µA, as stated in the verified Texas Instruments datasheet snippet. This low power consumption is important for battery-operated medical, data-acquisition, and portable instrumentation systems because the amplifier continues consuming current even when the measured signal is static. Actual system power also includes external gain components and downstream circuitry.
Where can I download the INA122P datasheet?
You can download the official INA122P family datasheet from the Texas Instruments link https://www.ti.com/lit/ds/symlink/ina122.pdf. The TI product page is also available at https://www.ti.com/product/INA122. The verified distributor listing identifies INA122P as an eight-pin plastic DIP instrumentation amplifier, while the INA122 family page also describes available package options.
Where can I find the INA122P pinout?
The INA122P pinout is shown in the official Texas Instruments INA122 datasheet at https://www.ti.com/lit/ds/symlink/ina122.pdf. The distributor listing confirms an 8-PDIP package, but the exact pin names and numbering must be taken from the manufacturer datasheet rather than inferred from a generic DIP drawing. The package SVG key used on this page is dip-8.
What does INA122P do in a sensor circuit?
INA122P amplifies a differential sensor signal while rejecting common-mode noise. It is useful between low-level transducers and an ADC or measurement front end because its instrumentation-amplifier function combines differential input handling with low noise and low offset. The device supports signals from bridges, load cells, thermocouples, and similar sensors when the common-mode voltage remains within the specified range.
Is INA122P suitable for battery-powered medical equipment?
INA122P is explicitly identified by Texas Instruments as suitable for portable medical and data-acquisition applications, and its verified quiescent current is 60 µA. That low current supports battery-life objectives when the amplifier is continuously active. Final suitability still depends on the required common-mode range, output swing, safety requirements, and the system power architecture.
What is the common-mode range of INA122P?
The verified INA122 data lists a common-mode range extending to V− − 0.1 V. In practical terms, the differential input common-mode voltage must remain within this boundary for correct operation. This rating is particularly important in single-supply sensor circuits because the sensor may sit close to the lower supply rail. Check the complete manufacturer operating conditions before finalizing the input range.
Can INA122P operate from a single supply and dual supply?
Yes. The INA122P can operate from single supplies up to 36 V or from dual supplies up to ±18 V, according to the verified manufacturer data. The correct connection depends on the source signal and required output range. Single-supply operation is useful for low-power sensors, while dual-supply operation can simplify systems with bipolar signals.
How does INA122P compare with INA126PA?
INA122P and INA126PA are different instrumentation-amplifier families and should not be treated as drop-in equivalents without checking their individual datasheets. The verified comparison result describes INA122P as a precision, low-noise, micropower differential acquisition device, while the INA126PA comparison does not establish identical pinout or parameter matching. Use the package and pinout data before considering a replacement.
When should I choose INA122P over another instrumentation amplifier?
Choose INA122P when the design requires a low-power instrumentation amplifier with 60 µA quiescent current, operation from 2.2 V to 36 V, differential input handling, and low offset. It is particularly suitable for portable or battery-powered measurement systems. Choose another instrumentation amplifier when its input range, gain accuracy, bandwidth, noise, package, or qualification better matches the application.
What is the best drop-in replacement for INA122P?
No verified pin-to-pin replacement for INA122P is established by the supplied web data. The INA122 family page confirms package options for the INA122, but it does not provide enough evidence to declare another manufacturer’s part a drop-in replacement. Verify exact package dimensions, pin numbering, supply range, common-mode range, offset, gain network, and temperature limits before substitution.
What can replace INA122P?
The verified data does not identify a confirmed drop-in replacement for INA122P. The INA122 family includes package variants, but package variants are not automatically interchangeable unless the exact pinout and electrical requirements match. A functional instrumentation amplifier may substitute only after PCB and signal-chain validation; otherwise, treat replacement selection as a redesign.
Is INA122P the same as INA122U?
INA122P and INA122U are orderable variants in the INA122 family, but the verified distributor data explicitly identifies INA122P as an 8-pin plastic DIP part. The Mouser listing references INA122U variants but does not provide enough evidence here to confirm package equivalence or pin compatibility. Check the exact package suffix and mechanical drawing before treating the two as interchangeable.
What is the output swing of INA122P?
The verified INA122 data specifies a rail-to-rail output swing. This allows the output to approach the available supply rails more closely than a fixed, mid-range output limit, subject to load and operating conditions. Designers should still verify output headroom at the actual load, supply voltage, and temperature rather than assuming full rail-to-rail operation under every condition.
How should INA122P be used with a bridge or load-cell sensor?
Use INA122P between the differential sensor outputs and the next measurement stage, such as an ADC. Its instrumentation-amplifier architecture is intended to amplify the small differential signal generated by bridges and load cells while reducing common-mode interference. Confirm sensor excitation voltage, input common-mode range, gain-setting components, supply polarity, and output limits against the manufacturer datasheet.
Where to buy INA122P online?
The verified DigiKey listing provides a purchase page for INA122P and identifies the part as a Texas Instruments 1-circuit, 8-PDIP instrumentation amplifier. Mouser also lists INA122P for datasheet, inventory, and pricing information. Current unit prices and stock levels are not provided in the verified data, so check the distributor page for a live quotation and delivery availability.
What is the price of INA122P?
The verified data confirms that INA122P is sold through distributors, including DigiKey and Mouser, but it does not provide numeric prices. The pricing tiers in this page therefore remain unavailable rather than being estimated. Request a current quote from the distributor or use its live pricing page, and verify quantity breaks, stock, and date before purchasing.
What is the lead time for INA122P?
A numeric lead time for INA122P is not included in the verified web data. The DigiKey page is a purchasing reference, but the supplied data does not explicitly state a current stock quantity or delivery interval. Contact the distributor for a dated availability and lead-time quotation. Do not infer availability from the existence of a product page alone.
Is INA122P active or obsolete?
The latest supplied TI product-page result describes INA122 as a low-power instrumentation amplifier for portable medical and data-acquisition applications, and the verified distributor listing includes INA122P for sale. On that evidence, the part is treated as active for this data set. TI’s current product page should still be checked for formal lifecycle notices before a production design is released.
Is INA122P compliant with RoHS or REACH?
RoHS and REACH status for INA122P are not stated in the supplied verified data. The appropriate status fields are therefore recorded as unknown rather than assumed. Review the current Texas Instruments product documentation, material declaration, or distributor compliance information for the exact orderable MPN and package before making a compliance claim.
What are the key specifications engineers should know about INA122P?
The key verified specifications are 60 µA quiescent current, a 2.2 V to 36 V supply range, ±18 V dual-supply operation, common-mode range to V− − 0.1 V, rail-to-rail output swing, and a two-op-amp precision architecture. The verified listing also identifies the INA122P as a one-circuit, 8-PDIP instrumentation amplifier. Gain, bandwidth, exact noise, and temperature-dependent limits should be taken from the manufacturer datasheet.

Datos de referencia de ingeniería para INA122P — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose INA122P when the design needs a precision instrumentation amplifier for low-level differential signals and especially when battery life matters. Its verified 60 µA quiescent current, 2.2 V to 36 V single-supply range, ±18 V dual-supply capability, and common-mode range to V− − 0.1 V make it suitable for portable medical instruments, bridges, load cells, thermocouples, and industrial sensor interfaces. Choose an INA122PA or INA122U variant only after confirming the exact package, pinout, suffix, and ordering information. INA126PA should be considered only as a separately qualified candidate because the supplied comparison data does not establish drop-in equivalence or matching performance. If the application requires higher bandwidth, lower offset, different common-mode limits, or a different package, compare those specifications directly before placing an order.

Comparación con alternativas

Parámetro Este producto INA122PA INA122U INA126PA
Package 8-PDIP 8-PDIP 8-PDIP 8-PDIP
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type Precision instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier

Diferenciadores clave

  • Very low micropower consumption (frente a INA126PA)
  • Wide single-supply operating range (frente a INA122PA)
  • Single or dual supply flexibility (frente a INA122U)
  • Precision offset characteristics (frente a INA126PA)
  • Portable-instrumentation positioning (frente a INA122PA)

Notas de diseño

Use the verified 60 µA quiescent current as the baseline for battery and portable-instrumentation power budgeting, but include the current consumed by the gain-setting network, sensor, ADC, and external protection. Because INA122P accepts a 2.2 V to 36 V supply range, confirm the actual rail voltage against the sensor common-mode requirement and the required output headroom. Estimated: the amplifier’s own quiescent contribution at 3.3 V is 0.198 mW, calculated as 3.3 V × 60 µA; this excludes all other circuit loads.

Place the INA122P close to the sensor input connector and keep the differential input traces short, matched where practical, and away from switching nodes and high-current return paths. Use a quiet ground reference and follow the manufacturer datasheet for decoupling and gain-component placement. A long cable or improperly grounded sensor can introduce noise that no amount of downstream digital filtering can fully recover.

Do not assume that the output can swing exactly to either supply rail under every load, temperature, or supply condition. Although the verified data describes rail-to-rail output swing, check the manufacturer operating conditions and leave the required output margin for the ADC input range. Also verify the input common-mode voltage against the specified V− − 0.1 V limit before connecting a sensor.

Treat the reference and gain-setting network as part of the precision signal path. Keep those components physically close to the appropriate INA122P pins, use stable ground references, and avoid routing high-current or digital return paths beneath differential inputs. If the sensor is remote, add appropriately selected input protection and filtering and validate the complete board for temperature drift and common-mode transients.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

The supplied verified data does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. These fields remain unknown rather than assumed.

Datos verificados el: 2026-10-22 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

INA122P INA122P datasheet Texas Instruments INA122P INA122P 60uA quiescent current INA122P 36V instrumentation amplifier 8-PDIP instrumentation amplifier INA122P load cell amplifier INA122P thermocouple interface INA122P vs INA126PA INA122P drop-in replacement INA122P buy online INA122P pinout

Componentes & términos relacionados

Texas Instruments INA122P INA122PA INA122U INA126PA instrumentation amplifier differential amplifier analog signal-conditioning IC two-op-amp architecture precision measurement 60 µA quiescent current 2.2 V to 36 V supply ±18 V dual supply common-mode range V− − 0.1 V rail-to-rail output 250 µV offset voltage 3 µV/°C offset drift 8-PDIP DIP package through-hole package load cell thermocouple bridge sensor portable medical equipment data acquisition
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ