INA141UAG4 - 1 MHz Instrumentation Amplifier | Texas Instruments
N.º de pieza: INA141UAG4 ✗ Fin de vidaINA141UAG4 Descripción general
An instrumentation amplifier is a specialized amplifier IC that measures the voltage difference between two inputs while suppressing signals common to both inputs. This is the low-dropout regulator hierarchy's measurement counterpart: INA141 belongs to the amplifier IC category, where the precision instrumentation-amplifier subclass provides high input impedance, internally configured gain, and strong common-mode rejection. Unlike a general-purpose operational amplifier, the INA141 integrates a complete differential measurement stage, reducing external matching requirements in many sensor and bridge circuits.
The INA141 family supports two fixed-gain selections, G = 10 and G = 100, so engineers can choose between greater signal amplification and lower closed-loop bandwidth without changing the external gain-setting network. Its 1 MHz bandwidth supports moderate-frequency sensor signals. The listed 110 dB CMRR is particularly valuable when a small differential measurement is superimposed on a larger common-mode voltage, while the 8 nV/√Hz input-noise figure favors low-level instrumentation where source impedance is compatible with the input network.
The INA141UAG4 uses an internal differential amplifier arrangement to preserve common-mode rejection and gain accuracy across its operating range. It is offered in an 8-SOIC package, allowing conventional surface-mount assembly and PCB routing. Because the product is listed as inactive by DigiKey, engineers should treat it as a legacy design and verify lifecycle availability, supported package variants, and any migration path before starting a new production run.
Typical uses include bridge-transducer interfaces, pressure and strain measurements, current-shunt monitoring, and buffered sensing of low-amplitude differential signals. In these systems, the INA141 can amplify the difference between sensor lines while rejecting much of the common-mode voltage present on both lines. Its two gain choices are useful when a design must accommodate both relatively large and small differential signals without adding a programmable gain amplifier.
The principal design consideration is to verify input common-mode range, output swing, supply requirements, gain-dependent bandwidth, and input bias-current effects against the manufacturer datasheet for the exact operating condition. The 8-SOIC footprint should be routed with short, symmetric input paths and a clean ground return to minimize conversion of external noise into differential error. Decoupling should follow the manufacturer's recommended application circuit.
This product page combines the Texas Instruments product description with distributor lifecycle information and practical guidance for evaluating the INA141UAG4. It also identifies package-compatible alternatives and highlights the engineering differences that matter when an obsolete or inactive instrumentation amplifier must be replaced without changing the board layout.
Alternativas directas para INA141UAG4 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con INA141UAG4 (mismo factor de forma y huella) — difiere en Package, Amplifier Type, Supply Voltage Range.
INA141UA
✅ Sustitución directa ⚠️ Especificaciones sin verificarConsulte el precio
Ver hoja de datos →INA141UAE4
✅ Sustitución directa ⚠️ Especificaciones sin verificarConsulte el precio
Ver hoja de datos →INA141UR
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
INA141U/2K5
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD621ARZ
✅ Sustitución directaConsulte el precio
Ver hoja de datos →INA141UAG4 Valores máximos y características eléctricas
| Product Type | Precision low-power instrumentation amplifier |
| Amplifier Count | 3 amplifiers |
| Gain | 10 or 100 |
| Bandwidth | 1 MHz |
| Common-Mode Rejection Ratio | 110 dB |
| Input Offset Voltage | 20 µV |
| Input Offset Voltage, Datasheet Listing | 250 µV |
| Input Noise Density | 8 nV/√Hz |
| Tipo de salida | Single-ended |
| Encapsulado | 8-SOIC, 0.154 inch body width, 3.90 mm width |
| Tipo de montaje | Surface mount |
Guía de configuración de pines de INA141UAG4 8-soic, 0.154 inch body width, 3.90 mm width
Configuración de pines para INA141UAG4 (encapsulado 8-soic, 0.154 inch body width, 3.90 mm width). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para INA141UAG4.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
INA141UAG4 es adecuado para 6 aplicacións: Bridge Transducer Measurement, Strain-Gauge Signal Conditioning, Precision Current-Shunt Monitoring, Industrial Pressure Sensor Interface, Medical and Diagnostic Signal Conditioning, Low-Level Analog Sensor Interface.
Bridge Transducer Measurement
The INA141UAG4 fits bridge-transducer front ends that require a small differential output to be amplified while voltage shared by both sensor inputs is rejected. Its fixed gains of 10 and 100 allow the same amplifier family to cover different bridge sensitivities, and the listed 1 MHz bandwidth is suitable for moderate-frequency measurement channels. The listed 110 dB CMRR can reduce errors from common supply or ground disturbances encountered in sensor systems. Place the amplifier close to the bridge inputs, maintain symmetrical routing, and verify that bridge excitation, input common-mode voltage, and output swing remain inside the manufacturer limits.
Recomendado
Strain-Gauge Signal Conditioning
INA141UAG4 is appropriate for strain-gauge conditioning where a mechanical element generates a small differential voltage across bridge arms. The available gain choices of 10 and 100 provide useful scaling without an external gain-setting resistor, while the 8 nV/√Hz listed input-noise density supports low-level signal work. The 1 MHz bandwidth accommodates sensor dynamics beyond static resistance measurement, subject to the gain-specific response in the manufacturer datasheet. Short input traces, guard grounding, and a low-noise excitation source are important because they directly affect the integrity of the small differential signal.
Recomendado
Precision Current-Shunt Monitoring
The INA141UAG4 can monitor a current shunt when the shunt voltage is small and the measurement must reject voltage common to both sides of the shunt. A gain of 10 or 100 increases the useful output range without requiring an adjustable gain stage, and the listed 110 dB CMRR helps preserve measurement accuracy in systems with ground offsets or shared supply noise. The amplifier should be positioned so its input loop remains small, with Kelvin-style routing where practical. Confirm that the shunt common-mode voltage does not exceed the INA141 input range and that the output remains within the supply rails.
Recomendado
Industrial Pressure Sensor Interface
INA141UAG4 is suitable for conditioning the output of pressure, force, and displacement sensors that produce low-level differential signals in industrial environments. Fixed gains of 10 and 100 simplify analog scaling, and the 1 MHz bandwidth provides margin for sensor and filtering requirements beyond a purely static measurement. The single-ended output can feed a downstream data converter or control-system input. The design must remain within the device's supply, common-mode, and output-swing limits, while PCB isolation should prevent motor, relay, and switching-supply noise from entering the sensitive input path.
Recomendado
Medical and Diagnostic Signal Conditioning
INA141UAG4 can serve as the analog front end of a low-level diagnostic or physiological measurement channel when its input range, offset, noise, and bandwidth satisfy the system requirements. The listed 20 µV typical offset and 8 nV/√Hz noise density are useful for small-signal conditioning, while 110 dB CMRR helps reject common-mode voltage on patient or sensor connections. A medical design must additionally evaluate isolation, leakage, safety, and application-specific standards; this IC alone does not provide those protections. Use the manufacturer datasheet to establish the achievable accuracy and configure gain and filtering accordingly.
Recomendado
Low-Level Analog Sensor Interface
INA141UAG4 fits generic analog sensor interfaces where the transducer produces a differential voltage and the next circuit requires a scaled, single-ended signal. Gain selections of 10 and 100 offer two useful sensitivity ranges, and the 1 MHz bandwidth permits filtering or modulation beyond DC. The amplifier reduces the number of external gain-setting components compared with a discrete three-op-amp implementation. For reliable operation, verify source impedance, input bias-current error, common-mode limits, output swing, and supply noise. Place decoupling capacitors close to the device and keep the sensitive input path physically separate from switching nodes and high-current returns.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para INA141UAG4 — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | INA141UA | INA141UAE4 | INA141UR | INA141U/2K5 | AD621ARZ |
|---|---|---|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Product Type | Precision low-power instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Instrumentation amplifier |
Diferenciadores clave
- Two integrated fixed-gain choices simplify sensor scaling (frente a AD621ARZ)
- Strong common-mode rejection for differential sensing (frente a AD621ARZ)
- Low-noise input suitable for precision instrumentation (frente a INA141UA)
Notas de diseño
Route the two differential inputs as a short, closely coupled pair and connect their return path to the quiet analog ground associated with the sensor. Minimize loop area because magnetic and capacitive coupling can appear directly as differential error. Keep the INA141UAG4 away from switching-node copper, high-current relay paths, and isolated power-converter returns. The manufacturer pin-description table should be used when assigning the eight SOIC pads.
Design the analog filter around the selected fixed gain rather than assuming one bandwidth applies to both G = 10 and G = 100. The family is listed with 1 MHz bandwidth, but the gain-dependent response, output settling, and common-mode rejection vary with frequency. Confirm those curves in the INA141 datasheet, then place any additional input or output filtering close to the corresponding pins to avoid adding board-level noise pickup.
Do not treat the INA141UAG4 as a general-purpose rail-to-rail operational amplifier. Its input common-mode range, output swing, supply range, and reference connections must be checked at the exact signal extremes and gain setting. The two distributor indexes also present different offset-voltage figures, so use the gain-specific manufacturer test condition for error budgets rather than copying an isolated headline number into a precision calculation.
Información de cumplimiento
No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was identified for the exact INA141UAG4 ordering code.