INA240A2D - 50V/V Bidirectional Current-Sense Amplifier | Texas Instruments
N.º de pieza: INA240A2D ✓ ActivoINA240A2D Descripción general
A current-sense amplifier is a specialized instrumentation amplifier that converts the differential voltage across a precision shunt resistor into a scaled voltage proportional to current. The INA240 belongs to the current-sense amplifier category and the broader amplifier and measurement IC hierarchy. Its bidirectional architecture supports both positive and negative current, while its negative common-mode capability allows operation below ground during the flyback interval of inductive loads.
The A2 gain option provides 50 V/V amplification, allowing a small shunt drop to produce an easily measurable output. The -4 V to 80 V common-mode range supports low-voltage motor systems, industrial 24 V and 48 V buses, and automotive-style transient environments. The manufacturer identifies the device as an ultra-precise current-sense amplifier with enhanced PWM rejection. Its operating temperature range extends from -40 °C to +125 °C for industrial and automotive temperature-grade designs.
The INA240 uses a differential input arrangement to reject supply ripple and common-mode voltage while measuring the shunt differential. Bidirectional operation allows the output to move above or below ground to indicate current direction. The 8-SOIC format supports conventional surface-mount assembly and provides a practical package for power-control boards where the shunt may be separated from sensitive analog circuitry.
Typical uses include BLDC and brushed motor control, solenoid and relay current monitoring, DC-DC converter feedback, battery charge and discharge measurement, inverter leg monitoring, and industrial power-supply protection. The wide common-mode range is particularly useful when the sensed current is switched while the amplifier supply remains independent of the high-voltage power rail.
Design the shunt and analog path carefully. Keep the differential input traces short and symmetric, place the amplifier close to the shunt, and use low-value resistors with appropriate pulse ratings. Input filtering must preserve the intended measurement bandwidth while attenuating high-frequency switching noise. Verify common-mode voltage, output swing, supply headroom, thermal performance, and amplifier saturation before committing the PCB layout.
This page consolidates the device architecture, operating limits, application guidance, package details, sourcing workflow, and drop-in replacement analysis into one engineering reference. It also identifies where application-specific values must be calculated from the actual shunt resistance, current waveform, board environment, and power-supply topology.
Alternativas directas para INA240A2D — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
INA240A2D-Q1
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
INA240A2D Valores máximos y características eléctricas
| Device Type | Bidirectional current-sense amplifier |
| Fixed Gain | 50 V/V |
| Common-Mode Voltage Range | -4 V to 80 V |
| Tipo de salida | Bidirectional voltage output |
| PWM Rejection | Enhanced |
| Rango de temperatura de funcionamiento | -40 °C to +125 °C |
| Encapsulado | 8-pin SOIC |
| Recuento de pines | 8 pins |
| Tipo de montaje | Surface mount |
| Automotive Temperature Grade | Supported |
Guía de configuración de pines de INA240A2D 8-pin soic
Configuración de pines para INA240A2D (encapsulado 8-pin soic). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para INA240A2D.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
INA240A2D es adecuado para 6 aplicacións: BLDC Motor Phase-Current Sensing, Solenoid and Relay Current Monitoring, 48 V Industrial DC-DC Converter Feedback, Battery Charge and Discharge Monitoring, Inverter Leg and DC-Link Protection, Automotive High-Side Load Monitoring.
BLDC Motor Phase-Current Sensing
The INA240A2D fits BLDC motor control because its -4 V to 80 V common-mode range accommodates switched phase voltages while its 50 V/V gain converts a small shunt differential into a controller-friendly analog signal. Enhanced PWM rejection helps reduce disturbance caused by fast edge transitions. Place the amplifier near the low-side shunt and route the differential inputs as a short, symmetric pair. Confirm that the maximum phase voltage, negative regenerative transient, amplifier supply, and output swing remain within the device limits throughout fast commutation.
Recomendado
Solenoid and Relay Current Monitoring
For solenoid and relay feedback, the INA240A2D can sense current in a path that swings above ground and briefly below ground. Its -4 V common-mode limit supports the negative flyback interval described for typical inductive loads, while bidirectional output reports current polarity. With a 50 V/V gain, a 10 mV shunt drop yields approximately 0.5 V output at nominal gain. Confirm flyback magnitude, shunt pulse energy, output saturation behavior, and the independent amplifier-supply requirement before production release.
Recomendado
48 V Industrial DC-DC Converter Feedback
The INA240A2D is appropriate for current-mode control or protection in a 48 V industrial DC-DC converter because the -4 V to 80 V common-mode range covers a nominal 48 V bus and associated switching excursions. The 50 V/V gain scales the shunt voltage for comparison with a control threshold or ADC input. Its enhanced PWM rejection supports operation next to high-dv/dt power stages. Validate the absolute common-mode maximum, output headroom, converter startup behavior, shunt power rating, and layout isolation at the intended switching frequency.
Recomendado
Battery Charge and Discharge Monitoring
The INA240A2D can monitor charge and discharge current in battery systems by operating bidirectionally across a low-side shunt. Its 50 V/V gain provides useful resolution for small resistive drops, while the -4 V to 80 V common-mode range covers many portable and industrial battery architectures. The enhanced PWM rejection characteristic helps when the sensed rail is switched. Select a shunt with suitable continuous current, pulse energy, and temperature rating, and verify that the measured current does not drive the output outside its linear range.
Recomendado
Inverter Leg and DC-Link Protection
The INA240A2D is useful for inverter leg-current measurement where high common-mode voltage and PWM edges coexist near the shunt. Its -4 V to 80 V common-mode capability accommodates many 24 V and 48 V power-stage environments, and the 50 V/V gain provides a compact analog measurement path. Enhanced PWM rejection improves disturbance control but does not remove the need for careful filtering and layout. Confirm the maximum rail voltage including overshoot, shunt pulse rating, propagation behavior, and fault-path response during short-circuit events.
Recomendado
Automotive High-Side Load Monitoring
The INA240A2D supports high-side load-current monitoring when the load rail lies within the -4 V to 80 V common-mode range. The fixed 50 V/V gain and bidirectional response allow the same circuit to measure load current and regenerative or reverse current. The wide -40 °C to +125 °C operating range is suitable for harsh environments, while enhanced PWM rejection helps with switched automotive loads. Review the applicable automotive qualification requirement, transient protection, shunt placement, thermal performance, and ISO-style EMC design practices for the final vehicle platform.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para INA240A2D — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | INA240A2D-Q1 |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC | 8-pin SOIC |
| Device Type | Bidirectional current-sense amplifier | Bidirectional current-sense amplifier |
| Fixed Gain | 50 V/V | 50 V/V |
| Common-Mode Voltage Range | -4 V to 80 V | -4 V to 80 V |
| PWM Rejection | Enhanced | Enhanced |
| Operating Temperature Range | -40 °C to +125 °C | -40 °C to +125 °C |
| Qualification Class | Automotive temperature grade | Automotive qualified |
Diferenciadores clave
- Automotive-qualified same-family replacement (frente a INA240A2D-Q1)
- Wide common-mode operating window (frente a INA240A2D-Q1)
- PWM-oriented measurement architecture (frente a INA240A2D-Q1)
Notas de diseño
Place the INA240A2D close to the shunt and route IN+ and IN- as a short, tightly coupled differential pair. Keep switching-node copper, inductors, and high-current return paths away from the input and output pins. A compact placement reduces the area vulnerable to capacitive pickup from PWM edges, while symmetrical routing helps preserve differential behavior. Connect the device ground and exposed return structure according to the manufacturer pin-description and layout guidance.
Do not assume the common-mode rating is a substitute for a complete input-transient design. First confirm that the instantaneous shunt common-mode voltage remains between -4 V and 80 V, including ringing and overshoot. Second, verify that the amplifier supply provides sufficient input and output headroom. Third, calculate the nominal output as 50 times the shunt voltage and check that the expected positive and negative current peaks do not saturate the output.
Treat the shunt as part of the signal path, not merely as a power component. Select a Kelvin connection so high-current copper voltage drops do not appear between the amplifier inputs. If PWM transients require filtering, calculate resistor and capacitor values from the required attenuation and measurement bandwidth rather than adding large capacitors that can delay fault detection. Validate the completed layout under switching conditions with the intended shunt, ground plane, and enclosure arrangement.
Calculate shunt dissipation independently from amplifier power. Estimated: with shunt resistance R and current I, shunt power is P = I²R; for example, 2 A through 10 milliohms produces 40 mW. Use the worst-case peak, pulse duration, ambient temperature, and pulse-energy rating when selecting the shunt. This estimate does not include layout or connector resistance and does not replace the shunt manufacturer's derating guidance.
The INA240A2D uses a fixed 50 V/V gain, so input-referred offset and noise become increasingly important as shunt resistance and measured current decrease. Keep the shunt drop comfortably above the total input-error contribution while retaining enough headroom for transient peaks. For small-current measurements, compare the complete measurement bandwidth, shunt power, thermal drift, and ADC resolution rather than selecting gain solely from the instantaneous output voltage.
Información de cumplimiento
The INA240A2D is identified as an automotive-temperature-grade device, but a formal AEC-Q100 qualification status and specific environmental declarations require confirmation from the applicable ordering documentation.