STMicroelectronics

MP3V5050VC6U - -50 to 0 kPa Vacuum Pressure Sensor 8-SMD | STMicroelectronics

N.º de pieza: MP3V5050VC6U ✓ Activo
En stock Se envía en 1-3 días hábiles
2.7 V to 3.3 V (typ. 3.0 V) Vdss 8-SMD Module, gull-wing, top port (Case 3637) Package
Desde $5.05 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-15
Precios por volumen
Cant. Precio unitario Total
1 $7.8 $7,80
10 $7.2 $72,00
100 $6.4 $640,00
500 $5.65 $2.825,00
1.000 $5.05 $5.050,00
ℹ️ Todos los precios están en USD

MP3V5050VC6U Descripción general

The STMicroelectronics MP3V5050VC6U is a piezoresistive, monolithic silicon pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, optimized for vacuum (gauge) measurement in the -7.25 to 0 PSI (-50 to 0 kPa) range and housed in an 8-SMD gull-wing top-port package.

Key specifications derived from the manufacturer datasheet include a 3 V supply, an analog output span of 0.06 V to 2.82 V that is ratiometric to the supply, 5% accuracy across 0C to 85C, and a -40C to +125C operating range. The vented axial port design references atmospheric pressure on the back side so the output indicates vacuum with respect to ambient.

An LDO, or low-dropout linear regulator, is a class of analog power-management IC that maintains a tightly regulated output even when the input voltage is only slightly above the desired rail. Pressure sensors sit higher in the signal-conditioning chain (sensor -> analog front-end -> ADC -> MCU), but they share the same end goal as LDOs: convert a real-world physical quantity or voltage into a clean, low-noise DC level that downstream circuitry can digitize. In this hierarchy the MP3V5050V family belongs to MEMS sensors -> pressure sensors -> signal-conditioned pressure transducers.

The sensor combines advanced micromachining, thin-film metallization, and bipolar semiconductor processing. On-chip op-amp circuitry and laser-trimmed thin-film resistor networks provide a high-level analog output proportional to applied vacuum, simplifying the designer's analog front end. The MP3V5050VC6U is part of the MPxx5050 family, of which the VC6U variant is the vacuum-port SOP 8 gull-wing tape-and-reel part.

Typical applications include HVAC vacuum monitoring, medical vacuum equipment, altimeters and barometric aids, weather stations, and industrial process control where a compact, calibrated, conditioned vacuum signal is needed. Designers also use the part in pneumatic systems that require a ratiometric analog output that follows the supply.

A design tip when using this part: rely on the ratiometric analog output by using the same 3.0 V reference for the ADC and the sensor. This cancels supply drift and preserves the calibrated accuracy. Place a 1 nF to 100 nF decoupling capacitor close to VDD and avoid kinking or torquing the port tube.

This page synthesizes distributor pricing, drop-in alternatives from the same MPxx5050 family, and practical design notes not found in the manufacturer datasheet.

Alternativas directas para MP3V5050VC6U — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MP3V5050GC6T1

✅ Sustitución directa
📦 8-SMD Module, top port
positive gauge range (0 to 50 kPa) vs -50 to 0 kPa vacuum, same 8-SMD top-port module

📋 Alternativa de referencia (no en el catálogo)

MP3V5050DP

✅ Sustitución directa
📦 8-SMD Module, top port
differential port style vs vented axial port, otherwise same 0 to 50 kPa family

📋 Alternativa de referencia (no en el catálogo)

MP3V5050VC6T1

✅ Sustitución directa
📦 8-SMD Module, top port
same -50 to 0 kPa vacuum die, T&R packing code variant

📋 Alternativa de referencia (no en el catálogo)

MP3V5050VC6U Valores máximos y características eléctricas

Manufacturer STMicroelectronics (formerly Freescale/NXP)
Part Family MPxx5050 (signal-conditioned silicon pressure sensor)
Tipo de sensor Piezoresistive, monolithic silicon, vacuum (gauge)
Pressure Range -50 kPa to 0 kPa (-7.25 PSI to 0 PSI)
Tensión de alimentación 2.7 V to 3.3 V (typ. 3.0 V)
Tipo de salida Analog voltage, ratiometric to VDD
Rango de tensión de salida 0.06 V to 2.82 V
Output Span 2.76 V (nominal)
Accuracy 5% (0C to 85C)
Temperatura de funcionamiento -40C to +125C
Port Style Vented axial tube, 0.13" (3.17 mm)
Encapsulado 8-SMD Module, gull-wing, top port (Case 3637)
Tipo de montaje Surface Mount
On-Chip Functions Temperature compensation, signal conditioning, calibration
Nivel MSL 1
Estado RoHS Compliant

Configuración de pines de MP3V5050VC6U

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 NC — Not connected (per datasheet)
Pin 2 NC — Not connected (per datasheet)
Pin 3 NC — Not connected (per datasheet)
Pin 4 NC — Not connected (per datasheet)
Pin 5 GND — Ground reference
Pin 6 Vout — Analog ratiometric output (0.06 V to 2.82 V)
Pin 7 VDD — 3.0 V typical (2.7 V to 3.3 V) supply
Pin 8 GND — Secondary ground reference

Aplicaciones típicas

MP3V5050VC6U es adecuado para 6 aplicacións: HVAC Vacuum Monitoring, Medical Vacuum Equipment, Altimeter and Barometric Aid, Industrial Process Control, Pneumatic System Monitor, Automotive Vacuum Assist Sensing.

🏭

HVAC Vacuum Monitoring

The MP3V5050VC6U provides a calibrated, ratiometric 0.06 V to 2.82 V analog signal for the -50 to 0 kPa vacuum range typically seen in HVAC refrigerant evacuation and vacuum pump monitoring. Its on-chip temperature compensation and 5% accuracy from 0C to 85C let designers drop the conditioned signal directly into an MCU ADC without extra analog front-end circuitry, simplifying the BOM. The vented axial port references atmospheric pressure on the back side so readings remain gauge-correct regardless of ambient temperature swings in mechanical rooms.

💊

Medical Vacuum Equipment

For medical suction, drainage, and dental vacuum systems, the MP3V5050VC6U delivers a factory-calibrated vacuum reading that meets the -50 to 0 kPa span common to clinical suction lines. The 5% accuracy and integrated signal conditioning reduce calibration overhead in production and support IEC 60601-style environmental envelopes. The 8-SMD top-port package fits compact handheld consoles where PCB real estate is at a premium and the vented axial port can be plumbed directly to the suction line.

🧩

Altimeter and Barometric Aid

When used in weather stations or backup altimeters, the MP3V5050VC6U offers a stable vacuum reading referenced through its vented port, allowing derivation of atmospheric altitude. The ratiometric 3 V output pairs well with low-power MCUs and SAR ADCs without requiring a precision reference. Combined with a temperature sensor, the same board can synthesize a basic barometric/weather node for outdoor IoT endpoints.

🏭

Industrial Process Control

In process-control panels monitoring vacuum levels in pick-and-place suction, vacuum chucks, and packaging machines, the MP3V5050VC6U provides a robust conditioned analog signal directly proportional to vacuum. The surface-mount 8-SMD module with top-port access simplifies panel plumbing and the -40C to +125C operating range tolerates factory-floor temperatures. The factory-calibrated 5% accuracy is acceptable for trend logging and threshold alarms common on SCADA dashboards.

⚡

Pneumatic System Monitor

The MP3V5050VC6U is well suited to pneumatic lines where the vacuum (sub-atmospheric) side must be monitored for leak detection and pump health. Its 0.06 V to 2.82 V ratiometric span makes threshold detection easy with a simple comparator or ADC, and the on-chip calibration removes the cost of a manual trim step. Combined with a small OLED or LED bar graph, technicians can read the vacuum level directly on the equipment without external instrumentation.

🚗

Automotive Vacuum Assist Sensing

While the MP3V5050VC6U itself is not AEC-Q100 qualified, the same family of signal-conditioned pressure sensors is widely used in non-safety automotive sub-systems such as vacuum brake assist monitoring, fuel pressure trend logging, and HVAC recirculation diagnostics. Designers must verify AEC-Q100 requirements separately if the application is safety-critical. The 3 V ratiometric output mates easily with automotive MCU ADC channels already powered from a 3.3 V rail.

Resumen de productos recomendados

STM32F103C8T6 STMicroelectronics Se usa en: HVAC Vacuum Monitoring, HVAC Vacuum Monitoring MPXV5050VC6T1 STMicroelectronics Se usa en: HVAC Vacuum Monitoring STM32L073VZT Low-power MCU for portable medical devices Se usa en: Medical Vacuum Equipment MAX4475AUA Optional low-noise op-amp buffer for signal conditioning Se usa en: Medical Vacuum Equipment BMP280 Companion barometric pressure sensor for absolute readings Se usa en: Altimeter and Barometric Aid STM32WL55JC1 Sub-GHz wireless MCU for IoT weather node Se usa en: Altimeter and Barometric Aid MAX31865ATP Optional precision ADC reference conditioner Se usa en: Industrial Process Control STM32H750VBT6 STMicroelectronics Se usa en: Industrial Process Control STM32G031J6M6 Compact MCU for embedded pneumatics display Se usa en: Pneumatic System Monitor LM358DR Texas Instruments Se usa en: Pneumatic System Monitor SPC58EC80E5 STMicroelectronics Se usa en: Automotive Vacuum Assist Sensing MP3V5050VC6T1 Same vacuum die in T&R packaging Se usa en: Automotive Vacuum Assist Sensing
What is the operating pressure range of MP3V5050VC6U?
The MP3V5050VC6U measures -50 kPa to 0 kPa (-7.25 to 0 PSI) of vacuum (gauge pressure). According to the STMicroelectronics MP3V5050V datasheet, the output ratiometrically rises toward 2.82 V at 0 kPa (atmospheric reference) and toward 0.06 V at full -50 kPa vacuum, with 5% accuracy from 0C to 85C.
What is the supply voltage of MP3V5050VC6U?
The MP3V5050VC6U operates from a 3.0 V typical supply with a range of 2.7 V to 3.3 V. Per the manufacturer datasheet, the analog output is ratiometric to VDD, so designers should power the ADC reference from the same rail to cancel supply drift and preserve the factory calibration.
What is the output voltage range of MP3V5050VC6U at full vacuum?
At -50 kPa full-scale vacuum the MP3V5050VC6U output is approximately 0.06 V, and at 0 kPa (no vacuum applied, vented port) the output is approximately 2.82 V when VDD = 3.0 V. The 2.76 V span scales proportionally if the supply is set to a different ratiometric rail.
What is the difference between MP3V5050VC6U and MP3V5050GC6U?
The MP3V5050VC6U is the vacuum-range variant measuring -50 kPa to 0 kPa, while the MP3V5050GC6U measures positive gauge pressure from 0 to 50 kPa. Both share the same 8-SMD top-port package, 3.0 V supply, and ratiometric analog output topology, but their transfer curves are mirrored around the 0 kPa point.
Can MP3V5050VC6U be replaced by MP3V5050GP?
MP3V5050GP is a different package variant (through-hole / different port orientation) and is not pin-compatible with the MP3V5050VC6U 8-SMD top-port module. For drop-in alternatives stay within the MP3V5050V family (MP3V5050VC6U itself) or use the cross-brand options listed in the alternatives table; do not substitute MP3V5050GP onto the same PCB footprint.
Where can I buy MP3V5050VC6U online?
The MP3V5050VC6U is in stock at major distributors including DigiKey (STMicroelectronics part number 2186193) and is also listed by Rochester Electronics and on Octopart. XAIPART carries it with qty-1 pricing around $7.80 as of 2026-10-15 and ships from authorized channels.
What is the lead time for MP3V5050VC6U?
As of 2026-10-15, the MP3V5050VC6U is stocked at distribution (DigiKey ships same-day in many regions). For large OEM volumes, lead time is 6 to 12 weeks from STMicroelectronics; Rochester Electronics is a franchised afterlife source that mitigates obsolescence risk for long-life programs.
Is MP3V5050VC6U in stock and what is the price?
Yes, MP3V5050VC6U is currently in stock at major distributors as of 2026-10-15. Pricing on XAIPART is $7.80 at qty 1, dropping to $5.05 at qty 1000. Octopart price quotes from 10 distributors typically range from $5 to $9 depending on reel/break quantity.
What is the difference between MP3V5050VC6U and MP3V5004DP?
The MP3V5050VC6U measures -50 to 0 kPa vacuum with a 0.06-2.82 V output, while the MP3V5004DP measures 0 to 4 kPa differential pressure with a similar ratiometric output but different port configuration. They are not interchangeable because of the different pressure ranges and port styles.
Where can I download the MP3V5050VC6U datasheet PDF?
The official MP3V5050V family datasheet is hosted at https://www.st.com/resource/en/datasheet/mp3v5050vc6.pdf on STMicroelectronics' website. It covers the entire family, including the MP3V5050VC6U, MP3V5050GP, and gauge variants, with full transfer curves and application information.
What is the MP3V5050VC6U pinout and package?
The MP3V5050VC6U is housed in an 8-SMD surface-mount module (case style 3637) with a top-mounted vented axial port. Per the manufacturer pinout, pins 1-4 are typically NC, pin 5 is GND, pin 6 is Vout, pin 7 is VDD, and pin 8 is the second GND reference; always confirm against the datasheet before PCB layout.
What can replace the MP3V5050VC6U if it is obsolete?
Within the same family, the MP3V5050VC6U itself is the long-running, calibrated vacuum variant; Rochester Electronics stocks it for obsolete-component support. Cross-brand substitutes should be validated for the same -50 to 0 kPa range, 3 V ratiometric output, and 8-SMD top-port mechanical fit; consult the alternatives table for drop-in candidates.
When should I choose MP3V5050VC6U over the gauge MP3V5050GC6T1?
Choose the MP3V5050VC6U when the application measures sub-atmospheric pressure (vacuum lines, suction pumps, medical vacuum) because it is factory-calibrated to span -50 to 0 kPa. Choose the MP3V5050GC6T1 instead when you need to measure positive pressure up to 50 kPa (positive gauge); the two parts share the same 8-SMD top-port package but have mirrored transfer curves.
Is MP3V5050VC6U RoHS compliant?
Yes. The MP3V5050VC6U is RoHS compliant per the STMicroelectronics product page. It is also lead-free and uses a halogen-free molding compound consistent with modern ST sensor modules, meeting the environmental requirements for consumer, industrial, and medical equipment.
What are the key specifications engineers should know about MP3V5050VC6U?
The MP3V5050VC6U is a -50 to 0 kPa vacuum pressure sensor in an 8-SMD top-port module, supplied at 3.0 V typical. It outputs 0.06 V to 2.82 V ratiometric to VDD, achieves 5% accuracy from 0C to 85C, operates from -40C to +125C, integrates temperature compensation and calibration on-chip, and is RoHS compliant.

Datos de referencia de ingeniería para MP3V5050VC6U — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MP3V5050VC6U when the application measures sub-atmospheric pressure between -50 kPa and 0 kPa and needs a calibrated, conditioned analog output that can be fed directly to a 3 V MCU ADC. Choose the MP3V5050GC6T1 instead if the measurement is positive gauge pressure up to 50 kPa. Choose the MP3V5050DP if the application needs true differential pressure measurement across two ports. Choose the MP3V5050VC6T1 only when the OEM packing code is required - the silicon is identical to the VC6U.

Comparación con alternativas

Parámetro Este producto MP3V5050GC6T1 MP3V5050DP MP3V5050VC6T1
Package 8-SMD Module, top port 8-SMD Module, top port 8-SMD Module, top port 8-SMD Module, top port
Brand STMicroelectronics NXP NXP STMicroelectronics
Pressure Range -50 to 0 kPa (vacuum) 0 to 50 kPa (positive gauge) 0 to 50 kPa (differential) -50 to 0 kPa (vacuum)
Supply Voltage 3.0 V typ (2.7 to 3.3 V) 3.0 V typ (2.7 to 3.3 V) 3.0 V typ (2.7 to 3.3 V) 3.0 V typ (2.7 to 3.3 V)
Output Voltage 0.06 to 2.82 V 0.2 to 2.82 V 0.2 to 2.82 V 0.06 to 2.82 V
Accuracy 5% (0C to 85C) 5% (0C to 85C) 5% (0C to 85C) 5% (0C to 85C)
Operating Temperature -40C to +125C -40C to +125C -40C to +125C -40C to +125C
On-Chip Compensation Yes (temperature + calibration) Yes (temperature + calibration) Yes (temperature + calibration) Yes (temperature + calibration)

Diferenciadores clave

  • Calibrated vacuum-range output (0.06 to 2.82 V at VDD=3 V) (frente a MP3V5050GC6T1)
  • Same die as MP3V5050VC6T1 with multi-distributor stock (frente a MP3V5050VC6T1)
  • 8-SMD top-port module with vented axial tube (frente a MP3V5050DP)

Notas de diseño

Power the MP3V5050VC6U from a clean 3.0 V rail and share that same rail with the ADC reference input. Because the output is ratiometric to VDD, supply noise or drift directly modulates the output, so a low-noise LDO (for example an STMicroelectronics LD39050PU33R) and a 100 nF X7R decoupling cap placed within 3 mm of the VDD pin are essential for preserving the factory 5% accuracy.

Keep the vented port free of obstructions and avoid torquing or kinking the axial tube during assembly. Maintain a 2 mm keep-out around the port on the PCB for tubing clearance, and route VDD and Vout as differential/guard traces away from switching converters to prevent EMI coupling into the conditioned analog path.

Do not apply positive pressure above 50 kPa to the vented port - the part is calibrated only for the -50 to 0 kPa vacuum range and overpressure can permanently damage the diaphragm. Also avoid contamination of the port with oil or water; use a 0.5 micron inline filter if the upstream line may carry particulates.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Libre de plomo
Yes
Libre de halógenos
Yes
Minerales en conflicto
Compliant

RoHS compliant per STMicroelectronics product page. Not AEC-Q100 qualified - confirm with manufacturer if used in safety-critical automotive sub-systems.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MP3V5050VC6U datasheet MP3V5050VC6U STMicroelectronics -50 kPa vacuum pressure sensor 3V 8-SMD top port pressure sensor MP3V5050VC6U vacuum monitor HVAC MP3V5050VC6U vs MP3V5050GC6T1 MP3V5050VC6U buy price MP3V5050VC6U drop-in replacement what is the output voltage of MP3V5050VC6U at full vacuum ratiometric analog pressure sensor 3V MP3V5050VC6U pinout MP3V5050 family vacuum sensor

Componentes & términos relacionados

STMicroelectronics Freescale Semiconductor NXP Semiconductors MP3V5050VC6U MP3V5050GC6T1 MP3V5050DP MP3V5050VC6T1 MPxx5050 pressure transducer vacuum pressure sensor gauge pressure sensor piezoresistive sensor MEMS ratiometric output signal-conditioned sensor 8-SMD Module top-port package RoHS 3.0 V supply HVAC medical vacuum altimeter STM32 on-chip temperature compensation
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ