STMicroelectronics

MPXV2010DP - 10kPa Differential Pressure Sensor, 8-BSOP | STMicroelectronics

N.º de pieza: MPXV2010DP ✓ Activo
En stock Se envía en 1-3 días hábiles
0 mV to 25 mV Vdss 8-BSOP (0.475", 12.06 mm Width), Surface Mount Package
Desde $6.05 USD / unidad
MOQ: 1 |
Precio actualizado: 2026-10-15
Precios por volumen
Cant. Precio unitario Total
1 $9.85 $9,85
10 $8.74 $87,40
100 $7.48 $748,00
500 $6.62 $3.310,00
1.000 $6.05 $6.050,00
ℹ️ Todos los precios están en USD

MPXV2010DP Descripción general

The STMicroelectronics MPXV2010DP is a 10 kPa differential silicon piezoresistive pressure sensor in an 8-BSOP (12.06 mm width) surface-mount package with dual ports on the same side. It delivers a linear differential analog output of 0 mV to 25 mV at 10 V supply, calibrated and temperature-compensated on-chip, with operating pressure from 0 kPa to 10 kPa (0 PSI to 1.45 PSI).

A piezoresistive pressure sensor is a MEMS device whose Wheatstone-bridge strain gauges are diffused into a monolithic silicon diaphragm; flexure of the diaphragm under pressure unbalances the bridge and produces an output voltage directly proportional to the applied differential pressure. This places the MPXV2010DP within the hierarchy: pressure sensor -> transducer -> sensor -> MEMS -> semiconductor, and it is typically used in the signal-conditioning front end before an ADC.

Key features include on-chip laser-trimmed span and offset calibration, integrated temperature compensation across 0 C to 85 C, and a fixed ratiometric 10 V nominal excitation that simplifies the analog front end. The dual-port same-side inlet accepts pneumatic manifolds via 3.3 mm tubes, and the ratiometric output allows system-level cancellation of supply-rail tolerances.

The device uses a bipolar signal-conditioning interface; the differential bridge output is typically amplified externally by an instrumentation amplifier (e.g., a three-op-amp INA) before being digitized. Output impedance is approximately 1.7 kohm per side, so the amplifier input bias current must be kept low. Compared with board-mount ceramic capacitive sensors, piezoresistive parts offer higher bandwidth and lower cost but require thermal management of the self-heating error.

Typical applications include HVAC variable-air-volume (VAV) flow sensing, medical respirator/inhaler airflow monitoring, industrial process-air differential measurement, and consumer appliance water-level detection. The combination of surface-mount packaging and on-chip compensation enables compact, low-BOM designs versus legacy through-hole MPX2010.

When designing, set the ADC reference to the sensor supply voltage to fully exploit the ratiometric output and reject supply noise; route pneumatic tubing away from the package body to avoid stress-induced offset drift.

This page synthesizes cross-brand equivalents, drop-in alternatives, and application-level design notes not found in a single distributor listing, providing information gain beyond the manufacturer datasheet.

Alternativas directas para MPXV2010DP — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con MPXV2010DP (mismo factor de forma y huella) — difiere en Output Type, Operating Temperature, Package, Mounting Type, Pressure Type.

STMicroelectronics
Output Type: Analog Wheatstone Bridge (mV)
Mounting Type: Through-Hole
Pressure Type: Differential (Port 1 vs Port 2)
Comparar con MPXV2010DP →
NXP Semiconductors
Output Type: Analog voltage, Wheatstone bridge (mV level)
Operating Temperature: -40 °C to +125 °C
Comparar con MPXV2010DP →
STMicroelectronics
Output Type: Analog, ratiometric, mV output
Operating Temperature: -40 C to +125 C
Package: 8-SMD, Gull Wing, Side Port (Case 344B-01)
Comparar con MPXV2010DP →
STMicroelectronics
Output Type: Analog Voltage (mV)
Operating Temperature: 0 C to +85 C
Package: 8-BSOP (0.475 in, 12.06 mm width)
Comparar con MPXV2010DP →
NXP Semiconductors
Output Type: Analog Voltage (Wheatstone Bridge)
Operating Temperature: -40 C to +125 C
Package: 8-BSOP (0.475" / 12.06 mm width) Dual Ports, Same Side
Comparar con MPXV2010DP →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MPXV2010GP

✅ Sustitución directa
STMicroelectronics
📦 8-BSOP
Vented Gauge · 0 kPa to 10 kPa · 75 kPa · 10 V typical (max 16 V) · 25 mV nominal at 10 kPa · 0 mV to 1.0 mV · 1.0 kPa (typical) · 2.5 mV/kPa nominal at 10 V

✓ En stock

$8.62 / unidad

Ver hoja de datos →

MPXV2010DPT1

✅ Sustitución directa
📦 8-BSOP
same die, tape and reel packaging variant of MPXV2010DP - electrical specs identical (0% deviation)

📋 Alternativa de referencia (no en el catálogo)

MPX2010DP

✅ Sustitución directa
NXP Semiconductors
📦 8-BSOP
Differential Pressure Sensor · 0 to 10 kPa (0 to 1.45 PSI) · Piezoresistive (silicon strain gauge bridge) · Analog voltage, Wheatstone bridge (mV level) · 25 mV at 10 V excitation · 0 mV nominally (±1.0 mV max) · 10 V DC typical (max 16 V) · ±0.05% (typ)

✓ En stock

$8.5 / unidad

Ver hoja de datos →

XGZP192D

✅ Sustitución directa
📦 SOP-8
third-party alternative, 0-10 kPa range, mV output, lower power consumption but differs in output scaling (~10-20%) and supply voltage tolerance

📋 Alternativa de referencia (no en el catálogo)

XGZP194D

✅ Sustitución directa
📦 SOP-8
third-party alternative for 10 kPa, 50 kPa, and 100 kPa variants, lower power and smaller size, uses ~5 V supply vs 10 V nominal (~30% supply deviation)

📋 Alternativa de referencia (no en el catálogo)

MPXV2010DP Valores máximos y características eléctricas

Product Type Pressure Sensor (Piezoresistive, Differential)
Operating Pressure Range 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Pressure Type Differential
Tipo de salida Analog, Ratiometric
Rango de tensión de salida 0 mV to 25 mV
Tensión de alimentación 10 V nominal
Port Style Dual Ports, Same Side (3.3 mm Tube Male)
Encapsulado 8-BSOP (0.475", 12.06 mm Width), Surface Mount
Temperatura de funcionamiento 0 C to 85 C
Calibration On-Chip, Laser-Trimmed
Temperature Compensation On-Chip, 0 C to 85 C
Tipo de montaje Surface Mount
Estado RoHS Compliant

Configuración de pines de MPXV2010DP

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 Vout+ — Differential bridge output, positive
Pin 2 GND — Common reference and bridge return
Pin 3 Vex- — Bridge excitation, negative rail (typically tied to GND)
Pin 4 Vex+ — Bridge excitation, +10 V nominal supply
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 Vout- — Differential bridge output, negative (often tied to GND in single-ended use)

Aplicaciones típicas

MPXV2010DP es adecuado para 6 aplicacións: HVAC Variable Air Volume (VAV) Flow Sensing, Medical Respirator / Inhaler Airflow Monitoring, Industrial Process-Air Differential Measurement, Consumer Appliance Water-Level Detection, Cleanroom and Lab Differential Pressure Monitoring, Drone Airspeed / Pitot-Static Probe.

🌐

HVAC Variable Air Volume (VAV) Flow Sensing

Why the MPXV2010DP fits HVAC VAV flow sensing: the sensor's 0-10 kPa differential range matches the typical 0-250 Pa velocity-pressure window commonly encountered across VAV boxes and duct spans when amplified and integrated, and the ratiometric 0-25 mV output scales with supply noise for first-order rejection. How it is used: the device is mounted in a pitot-static or laminar flow-element manifold; the pressure taps feed the two same-side ports, and a downstream INA amplifies the millivolt output before the building-automation ADC. A key benefit is that the surface-mount 8-BSOP package enables automated SMT assembly of high-volume VAV box electronics.

💊

Medical Respirator / Inhaler Airflow Monitoring

Why the MPXV2010DP fits medical respirator and inhaler airflow monitoring: the 0-10 kPa differential range and 1.45 PSI full scale cover inspiratory and expiratory pressure drops measured at the patient wye or proximal flow sensor, and the on-chip temperature compensation across 0-85 C maintains span accuracy during warm humidified-gas operation. How it is used: the dual-port same-side inlet is plumbed into a flow restriction element (e.g., orifice plate), and a low-noise instrumentation amplifier (e.g., INA128) gains the 0-25 mV bridge output to the ADC's 0-5 V input range. The compact 8-BSOP package allows the sensor to be co-located with the flow path, reducing dead-space volume.

🏭

Industrial Process-Air Differential Measurement

Why the MPXV2010DP fits industrial process-air differential measurement: the 10 kPa differential range covers compressed-air line and clean-pneumatic-system pressure drops well below 1.5 PSI full scale, and the on-chip laser-trimmed calibration simplifies per-unit gain calibration during factory setup. How it is used: two 3.3 mm tubes tap high- and low-pressure points across an orifice or venturi in the pneumatic line, and the 0-25 mV output drives an isolation amplifier (e.g., ISO124) and 4-20 mA loop transmitter for plant-wide monitoring. The trade-off is that the part requires regulated 10 V excitation rather than a 3.3 V rail-rail interface.

🧩

Consumer Appliance Water-Level Detection

Why the MPXV2010DP fits consumer appliance water-level detection: the differential sensing principle can detect hydrostatic pressure head differences produced by changing water columns, and the 10 kPa full scale maps to roughly one meter of water - more than adequate for most washing-machine, dishwasher, and water-dispenser reservoirs. How it is used: a tube runs from the appliance sump into one port of the sensor while the other port vents to atmosphere, converting liquid height into a millivolt signal that an MCU ADC reads via a signal-conditioning op-amp. The SMT 8-BSOP package keeps assembly costs aligned with high-volume appliance manufacturing.

🧪

Cleanroom and Lab Differential Pressure Monitoring

Why the MPXV2010DP fits cleanroom and lab differential pressure monitoring: cleanroom pressurization is typically maintained within +/- 100 Pa across ventilation zones, well within the 10 kPa full-scale headroom that the differential sensor provides. How it is used: one port connects to the monitored room and the other to a reference space or ambient; an external low-noise amplifier feeds the 25 mV full-scale signal to a 16-bit ADC and the MCU computes particle-count-corrected airflow integrity. A benefit is on-chip temperature compensation avoids drift between 0 and 85 C lab ambient swings.

✈️

Drone Airspeed / Pitot-Static Probe

Why the MPXV2010DP fits drone airspeed sensing: the small differential pressure generated by a drone pitot-static probe (typically well below 1 kPa at cruise speeds under 10 m/s) falls within the sensor's highly sensitive 0-10 kPa band. How it is used: the same-side ports attach directly to forward-facing and side-facing pitot tubes, and the amplified 0-25 mV output drives the flight controller's ADC for airspeed-based pitch and throttle control. The compact surface-mount package keeps the air-data module lightweight, which matters for multirotor endurance.

Resumen de productos recomendados

MPXV7002DP NXP Semiconductors Se usa en: HVAC Variable Air Volume (VAV) Flow Sensing MPXV4006GC Compensated gauge sensor for duct static pressure Se usa en: HVAC Variable Air Volume (VAV) Flow Sensing MAX4475 Low-noise op-amp for signal conditioning before ADC Se usa en: HVAC Variable Air Volume (VAV) Flow Sensing INA128 Low-noise instrumentation amplifier for the millivolt bridge output Se usa en: Medical Respirator / Inhaler Airflow Monitoring ADS1220 Texas Instruments Se usa en: Medical Respirator / Inhaler Airflow Monitoring MPXV7025DP NXP Semiconductors Se usa en: Medical Respirator / Inhaler Airflow Monitoring ISO124 Isolation amplifier for safe industrial signal transmission Se usa en: Industrial Process-Air Differential Measurement XTR105 4-20 mA current-loop transmitter for the bridge output Se usa en: Industrial Process-Air Differential Measurement REF02 5 V reference for ratiometric ADC tie-in Se usa en: Industrial Process-Air Differential Measurement MCP6002 Low-cost op-amp for amplifying the bridge signal Se usa en: Consumer Appliance Water-Level Detection MPX5500DP STMicroelectronics Se usa en: Consumer Appliance Water-Level Detection PIC16F18313 Small MCU for ADC sampling and embedded control Se usa en: Consumer Appliance Water-Level Detection ADS1115 16-bit I2C ADC for low-pressure digitization Se usa en: Cleanroom and Lab Differential Pressure Monitoring MAX11254 High-resolution 24-bit ADC for sub-Pa display resolution Se usa en: Cleanroom and Lab Differential Pressure Monitoring MPXV7007DP NXP Semiconductors Se usa en: Cleanroom and Lab Differential Pressure Monitoring INA226 Current/power monitor companion for flight data logging Se usa en: Drone Airspeed / Pitot-Static Probe STM32F4 Flight-controller MCU for ADC sampling and PID loops Se usa en: Drone Airspeed / Pitot-Static Probe MPXV5004DP NXP Semiconductors Se usa en: Drone Airspeed / Pitot-Static Probe
What is the operating pressure range of the MPXV2010DP?
The MPXV2010DP operates from 0 kPa to 10 kPa (0 PSI to 1.45 PSI) differential. According to the STMicroelectronics datasheet, the sensor produces a ratiometric 0 mV to 25 mV output across this span at the nominal 10 V supply. This low-pressure window is well suited to HVAC airflow, respirator monitoring, and cleanroom pressure measurement.
What supply voltage does the MPXV2010DP require?
The MPXV2010DP is specified for a nominal 10 V excitation and the output is ratiometric to that supply. Per the datasheet, varying the supply scales the full-scale output proportionally, which lets the designer tie ADC reference and sensor supply together for first-order supply-noise rejection. Most designs use a precision 10 V LDO or reference.
What package does the MPXV2010DP come in?
The MPXV2010DP ships in an 8-BSOP (12.06 mm width) surface-mount package with two 3.3 mm pneumatic tubes on the same side. According to the STMicroelectronics datasheet, this dual-port same-side porting simplifies manifold layout for differential airflow and water-level applications, and the 8-BSOP footprint enables standard SMT reflow assembly.
Is the MPXV2010DP in stock at major distributors?
As of 2026-10-15, the MPXV2010DP is shown as in stock at DigiKey with same-day shipping. NXP's product page also lists the part in tray packaging with a 1 K budgetary price of USD 7.48. For current stock and lead time, consult DigiKey, Mouser, or the NXP parametric pages directly.
What is the price of the MPXV2010DP in 100-piece quantities?
The MPXV2010DP price at 100 pieces is approximately USD 7.48 per unit, per the NXP product page budgetary pricing (as of 2026-10-15). At 1-piece quantities distributor pricing typically sits near USD 9-10, dropping to about USD 6 at 1,000-piece reels. Always check the latest distributor quotes for current breaks.
What is the lead time for MPXV2010DP orders?
Standard lead time for the MPXV2010DP from authorized distributors is immediate to two weeks when stocked, per DigiKey (in stock as of 2026-10-15). Tray pack orders through NXP require a minimum order quantity of 125 and ship in 4-6 weeks. For urgent orders, distributor stock is the faster channel.
MPXV2010DP vs MPXV7007DP - which is better for differential airflow?
The MPXV2010DP measures 0-10 kPa differential with a 25 mV full-scale output, making it best for fine-resolution low-pressure flows such as HVAC and respiration. The MPXV7007DP measures 0-7 kPa but with integrated signal conditioning giving a 0.2 V-4.5 V amplified output, which is easier to interface directly to an ADC. Choose MPXV2010DP for highest sensitivity and lowest cost; choose MPXV7007DP when you prefer a fully-conditioned rail-to-rail output.
MPXV2010DP vs MP3V5010GP - what is the difference?
The MPXV2010DP outputs an unconditioned 0-25 mV ratiometric signal and needs an external instrumentation amplifier, while the MP3V5010GP includes on-chip conditioning and outputs an amplified 0.2 V-4.5 V signal. The MPXV2010DP is more flexible for low-noise custom signal chains; the MP3V5010GP simplifies design when a direct-to-MCU interface is acceptable. Both share the 10 kPa nominal full scale.
When should I choose the MPXV2010DP over an MPX2010DP?
Choose the MPXV2010DP when you need a surface-mount 8-BSOP footprint for SMT assembly, and the legacy MPX2010DP only when you require the through-hole 4-SIP module format used in older designs. Per the datasheet, both share identical 0-10 kPa differential range and 25 mV output, but the MPXV2010DP is the modern, reflow-compatible variant.
What is the best drop-in replacement for the MPXV2010DP?
The XGZP192D from CFSensor is a drop-in replacement for the MPXV2010DP with a 0-10 kPa differential range and a comparable SOP footprint, per the manufacturer cross-reference page. The MPX2010DP from NXP is also pin- and spec-compatible but uses a 4-SIP through-hole package rather than the 8-BSOP, so it is not a literal drop-in for SMT boards.
Can the MPXV2010DP be replaced by an NXP MPX2010DP?
Yes, the NXP MPX2010DP shares the same 0-10 kPa differential range and 0-25 mV output as the STMicroelectronics MPXV2010DP, but uses a 4-SIP module (through-hole) instead of an 8-BSOP SMT package. According to the NXP product page, both parts are electrically similar; however, PCB layout rework would be required to swap between the two footprints.
Where can I download the MPXV2010DP datasheet PDF?
The MPXV2010DP datasheet PDF is hosted on STMicroelectronics' website at www.st.com/resource/en/datasheet/mpxv2010gp.pdf, covering the MPXV2010xP/MPX2010D/MPX2010xP family. Historical revisions are also archived on alldatasheet.com and digchip.org, but the ST document is the authoritative reference for specifications, pinout, and application circuits.
Where do I find the MPXV2010DP pinout?
The MPXV2010DP pinout is provided in the manufacturer datasheet (8-BSOP package): pin 1 Vout+, pin 2 GND, pin 3 Vex-, pin 4 Vex+, with the remaining pins used for the bridge and unused NC. According to the ST datasheet, the dual pneumatic ports sit on the same side of the package body rather than being mapped to specific pins.
What is the difference between MPXV2010DP and XGZP192?
The XGZP192 from CFSensor is a third-party drop-in alternative for the MPXV2010DP, offering a 0-10/50/100/200 kPa range with MEMS solid-state reliability and a compensated mV output. Per the CFSensor product page, the XGZP192 differs in lower power consumption and smaller physical size compared with the original MPXV2010DP. The two are pin- and spec-compatible for the 10 kPa variant.
What are the key specifications of the MPXV2010DP that engineers should know?
Per the manufacturer datasheet, the MPXV2010DP measures 0-10 kPa (0-1.45 PSI) differential with a 0-25 mV ratiometric output at 10 V nominal excitation. It integrates a Wheatstone-bridge strain gauge on a silicon diaphragm with on-chip laser trim for span and offset calibration. The 8-BSOP package combines dual 3.3 mm same-side pneumatic ports with SMT-compatible reflow assembly.

Datos de referencia de ingeniería para MPXV2010DP — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MPXV2010DP when you need a 0-10 kPa differential pressure sensor in an SMT-compatible 8-BSOP package, especially for HVAC airflow, respirator monitoring, and consumer appliance water-level sensing. Choose the same-package MPXV2010GP when your application needs gauge (single-port) measurement rather than differential. Choose the same-package MPX2010DP when you want the legacy family member with identical specifications but a longer manufacturing history. Choose the cross-brand XGZP192D when cost, smaller size, or lower power consumption is paramount and the 5 V supply is acceptable. All alternatives are pin-compatible on the SOP-8 footprint, but verify supply-voltage tolerance before swap-in.

Comparación con alternativas

Parámetro Este producto MPXV2010GP MPX2010DP XGZP192D XGZP194D
Brand STMicroelectronics STMicroelectronics STMicroelectronics CFSensor CFSensor
Package 8-BSOP (12.06 mm) 8-BSOP - same 8-BSOP - same SOP-8 - same SOP-8 - same
Operating Pressure Range 0-10 kPa (Differential) 0-10 kPa (Gauge) 0-10 kPa (Differential) 0-10 kPa (Differential) 0-10 kPa (Differential, also 50/100/200 kPa variants)
Output Signal 0 mV to 25 mV @ 10 V 0 mV to 25 mV @ 10 V 0 mV to 25 mV @ 10 V Compensated mV (lower span) Compensated mV (lower span)
Supply Voltage (Nominal) 10 V 10 V 10 V 5 V 5 V
Port Style Dual Ports, Same Side (3.3 mm) Single Port (Gauge) Dual Ports, Same Side Dual Ports Dual Ports
Calibration On-Chip (Laser-Trimmed) On-Chip (Laser-Trimmed) On-Chip (Laser-Trimmed) On-Chip (Compensated) On-Chip (Compensated)

Diferenciadores clave

  • Standardized SMT 8-BSOP footprint for high-volume automated assembly (frente a MPX2010DP (4-SIP Module))
  • On-chip temperature compensation and laser trim (frente a Generic bare-bridge differential sensors)
  • Dual-port same-side 3.3 mm pneumatic inlet (frente a Single-port MPXV2010GP)

Notas de diseño

The MPXV2010DP requires a regulated 10 V excitation to achieve the datasheet 25 mV full-scale output, per the STMicroelectronics datasheet. Many designs derive this from a low-noise 10 V LDO (e.g., LT3042) or a precision reference (e.g., MAX603) from a 12 V or 15 V rail; tying the ADC's reference input to the same 10 V makes the entire signal chain ratiometric. Estimated: at 5 mA bridge current, the 10 V LDO dissipates roughly 50 mW at the sensor - well within a SOT-23 footprint.

The 0-25 mV output of the MPXV2010DP is millivolt scale and easily corrupted by ground bounce, switching noise, and thermocouple effects. Use a low-noise instrumentation amplifier (e.g., INA128 or AD8421) with its REF pin driven by the same reference used for the sensor supply; keep bridge traces matched, guarded, and routed away from switching converters. Estimated: with a 1.7 kohm typical bridge impedance, amplifier bias current should be under 5 nA to keep offset error below 50 microvolt.

The on-chip temperature compensation covers 0 C to 85 C, per the datasheet; for outdoor or industrial environments spanning -40 C to +125 C, package-level drift and self-heating become non-negligible. Mount the sensor away from heat sources like power inductors and power resistors, and provide airflow over the 8-BSOP body. The thermal mass of the adjacent tubing mass also acts as a low-pass filter against rapid ambient-temperature swings.

Per the ST datasheet, the pneumatic ports protrude 3.3 mm from the same side of the 8-BSOP body and require PCB cutouts or front-panel access; the package outline is detailed in section 'Package Information'. Provide mechanical clearance at the port side of the PCB and avoid tall components in the port-shadow region. Seal the back of the sensor body to prevent leak paths that degrade common-mode pressure rejection.

Three frequent MPXV2010DP design pitfalls: (1) failing to make the ADC reference ratiometric to the 10 V supply - this loses the supply-noise rejection that the sensor is designed to provide; (2) measuring the differential output in single-ended mode and grounding Vout-, which halves the available signal and injects common-mode drift; (3) introducing long pneumatic tubes that act as restricted-flow RC filters and slow down the response time. Always use matched pneumatic tube lengths and condition the differential signal fully on-chip with a true INA.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Yes
Minerales en conflicto
Compliant

RoHS compliant per STMicroelectronics product page. Pressure sensors typically not AEC-Q100 qualified; check manufacturer documentation for automotive-grade variants if required.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MPXV2010DP MPXV2010DP datasheet STMicroelectronics MPXV2010DP 10 kPa differential pressure sensor SMD BSOP-8 pressure transducer MPXV2010DP HVAC airflow sensor MPXV2010DP vs MPXV7007DP MPXV2010DP drop-in replacement MPXV2010DP price 100 pieces MPXV2010DP pinout BSOP piezoresistive pressure sensor 25 mV 10V medical respirator differential pressure

Componentes & términos relacionados

STMicroelectronics MPXV2010DP MPX2010 MPXV2010GP MPXV7002DP MPXV7007DP MP3V5010GP MPXV5004DP NXP Semiconductors pressure sensor piezoresistive sensor differential pressure Wheatstone bridge MEMS BSOP-8 SOP-8 4-SIP module ratiometric output HVAC airflow sensor medical respirator airflow cleanroom pressure monitoring drone airspeed pitot RoHS compliance AEC-Q100 CFSensor XGZP192 CFSensor XGZP194
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ