محصولات (46,000+)

INA118UBG4 - Precision Instrumentation Amplifier | Texas Instruments
INA118UBG4

INA118UBG4 - Precision Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA118UBG4 is a precision, low-power instrumentation amplifier designed for accurate differential-signal measurement in an 8-pin SOIC package. It uses a three-amplifier architecture, provides a 50 µV input-offset-voltage specification, and offers an 800 kHz bandwidth rating. The device is intended for applications requiring low offset, low power consumption, and adjustable gain through a single external resistor. Its single-ended amplifier output is suitable for interfacing to analog-to-digital converters, sensors, and precision measurement systems. An instrumentation amplifier is a specialized amplifier category that measures a small voltage difference between two inputs while rejecting common-mode interference. The INA118 belongs to the broader precision amplifier hierarchy: instrumentation amplifier, differential amplifier, analog signal-chain IC, and semiconductor. This makes it more suitable than a general-purpose operational amplifier when the input signal is small, the source impedance is high, or the measurement environment contains substantial common-mode voltage. Key characteristics include three internal amplifiers, a 50 µV input offset voltage, an 800 kHz bandwidth rating, low-power operation, and a single-ended output. The three-amplifier topology supports gain adjustment from approximately 1 to 10,000 according to the device family documentation. A single gain-setting resistor keeps the circuit compact and simplifies calibration. The SOIC-8 package also supports conventional surface-mount assembly and is narrower than many larger instrumentation-amplifier packages. The INA118 architecture is intended for low-level differential measurements where offset and common-mode rejection determine accuracy. Its current-feedback input stage helps preserve usable bandwidth as gain increases. In practical systems, the external gain resistor, input filtering network, supply bypass capacitors, and grounding strategy directly affect achievable accuracy. Designers should place input filtering close to the amplifier and avoid routing sensitive input traces beside high-current switching paths. Typical uses include bridge and strain-gauge signal conditioning, biomedical instrumentation, current-shunt measurement, sensor interfaces, battery-powered instruments, and industrial data-acquisition systems. The INA118UBG4 is particularly appropriate when a low-power, compact, precision measurement front end is required and the output can drive a single-ended downstream ADC. A key design consideration is to verify the common-mode and output-voltage limits against the actual supply voltage and sensor signal range. Input protection, offset calibration, and reference grounding should be handled according to the manufacturer application guidance when operating near the electrical limits. The gain resistor should be placed close to the gain pin, and the layout should preserve a low-impedance return path. This page combines manufacturer-device identity, distributor availability information, technical specifications, same-package alternatives, comparison data, and practical layout guidance for engineers evaluating the INA118UBG4.

RFQ تماس
INA118UG4 - 800 kHz Low-Power Instrumentation Amplifier | Texas Instruments
INA118UG4

INA118UG4 - 800 kHz Low-Power Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA118UG4 is a precision, low-power instrumentation amplifier with 800 kHz bandwidth, 25 uV offset voltage, and 98 dB common-mode rejection in an 8-SOIC package. Designed for differential measurements, it accepts bipolar inputs while providing stable gain from 1 to 10,000 using one external resistor. The device is suitable for sensor, medical, and industrial signal-conditioning systems where low offset, high common-mode rejection, and compact packaging are important. An instrumentation amplifier is a differential amplifier optimized for amplifying a small voltage difference between two inputs while rejecting signals common to both inputs. Its hierarchy includes instrumentation amplifier, differential amplifier, analog amplifier, and integrated circuit. This application-specific architecture is more useful than a general-purpose op amp when the source is a low-level bridge, strain gauge, thermocouple, or current-sense element surrounded by substantial common-mode voltage. Key features include a three-op-amp internal architecture, current-feedback input circuitry, 800 kHz bandwidth, 25 uV input offset voltage, and 98 dB CMRR. A single external resistor establishes gains from 1 to 10,000, simplifying circuit configuration while retaining the internal resistor matching needed for accurate differential gain. The low-power design also supports portable and compact measurement systems that cannot accommodate a large analog signal chain. The current-feedback input stage preserves useful bandwidth at high closed-loop gain. According to the Texas Instruments INA118 product information, bandwidth remains 70 kHz at a gain of 100, an important consideration for systems that must preserve sensor-response speed without operating at unity gain. Supply operation from ±1.35 V to ±18 V permits use in both compact dual-rail systems and conventional analog power rails up to ±15 V typical. Typical applications include bridge-based pressure and load-cell measurement, low-voltage current sensing, isolated sensor interfaces, biomedical instrumentation, and industrial process monitoring. INA118UG4 is particularly appropriate when differential signal integrity matters more than absolute accuracy at low cost, because its internal three-op-amp design provides matched gain resistors and high common-mode rejection in one package. Designers should verify common-mode input range, output swing, supply polarity, and gain-bandwidth requirements at the actual operating voltage. A precision gain resistor, stable reference potential, and careful grounding of the reference and supply-return pins are important for low-offset measurements. Decoupling capacitors should be placed close to the supply pins using a layout that minimizes sensitive input-node coupling. This product page consolidates the INA118UG4 electrical characteristics, family replacements, application guidance, and practical design considerations into an engineering-focused selection resource. It also distinguishes direct family drop-ins from broader functional alternatives so designers can reuse a PCB only after verifying package dimensions, pinout, supply range, and gain-setting behavior.

RFQ تماس
INA121P - FET-Input Low Power Instrumentation Amplifier DIP-8 | Texas Instruments
INA121P

INA121P - FET-Input Low Power Instrumentation Amplifier DIP-8 | Texas Instruments

The Texas Instruments INA121P is a FET-input, low-power instrumentation amplifier (INA) offering excellent accuracy in an 8-pin PDIP package. It delivers ±4 pA typical bias current, ±450 µA quiescent current, ±200 µV input offset voltage, and ±2 µV/°C offset drift, with 106 dB common-mode rejection and a wide ±2.25V to ±18V supply range. What is an instrumentation amplifier? An instrumentation amplifier is a precision differential amplifier with very high input impedance, high common-mode rejection ratio (CMRR), and user-adjustable gain set by a single external resistor. INAs occupy the hierarchy: instrumentation amplifier -> differential amplifier -> operational amplifier -> analog IC. Compared with a discrete op-amp difference amp, a monolithic INA matches the input stage transistors on the same die, providing inherently high CMRR without precision resistor networks, making it the standard building block for low-level sensor signal conditioning. The INA121P's versatile three-op-amp topology and small footprint suit general-purpose precision applications. Internal input protection survives ±40V differential or common-mode faults, and gain is set from 1 V/V to 10,000 V/V using one external resistor between pins 1 and 8. Noise is specified at 20 nV/√Hz (f = 1 kHz) with 0.001% nonlinearity, and the bandwidth reaches 600 kHz (G = 100). The 8-pin PDIP through-hole package supports easy breadboarding and hand-repairable designs where surface-mount parts would be impractical. Architecture-wise, the INA121P uses CMOS FET input stages for sub-picoampere bias current and laser-trimmed thin-film resistors for gain accuracy. The three-op-amp topology delivers fully differential inputs and a single-ended output referenced to pin 5 (REF). Operation from a single supply down to ±2.25V accommodates battery-powered systems, while ±18V supplies support industrial 4-20 mA and ±15V signal chains. Typical applications include ECG/biomedical front-ends, weigh scales and load-cell bridges, thermocouple and RTD signal conditioning, industrial process-control transducer amplifiers, and audio-frontend microphone preamps requiring high CMRR. The ±4 pA input bias permits direct interface to photodiodes and high-impedance pH/ion-selective electrodes without input-bias compensation networks. Designers should guard-drive pin 1 and pin 8 (RG) with a buffered reference rather than leaving them floating when gain is set at minimum (1 V/V), and provide 0.1 µF supply bypass capacitors within 5 mm of pins 4 and 7. The 8-pin PDIP's higher thermal resistance (~80 °C/W) limits continuous dissipation above 400 mW, so PCB copper area should be assessed for productionized layouts. This page synthesizes distributor pricing, drop-in DIP-8 alternatives, and practical design notes not found in the manufacturer datasheet alone.

RFQ تماس
INA121PA - Low-Power FET-Input Instrumentation Amplifier | TI
INA121PA

INA121PA - Low-Power FET-Input Instrumentation Amplifier | TI

The Texas Instruments INA121PA is a single-circuit, FET-input, low-power instrumentation amplifier with ±4 pA input bias current, ±200 µV input offset voltage, and a 106 dB common-mode rejection ratio, packaged in an 8-pin plastic DIP. Its wide supply range of ±18 V, adjustable gain from 1 to 10,000 V/V, and 600 kHz bandwidth make it suitable for precision signal conditioning involving high-impedance sources. The three-op-amp architecture supports general-purpose instrumentation applications while maintaining low nonlinearity error of 0.001%. An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals superimposed on larger common-mode voltages. Its internal three-op-amp topology provides high input impedance, differential gain, and common-mode rejection without requiring matched external resistors. The INA121PA adds a FET-input stage whose ±4 pA bias current is particularly useful with sensors, transducers, and laboratory sources whose output impedance is high. Low power consumption is a central advantage of the INA121 family. Its typical quiescent current is ±450 µA, helping reduce supply demand in battery-operated and portable measurement systems. Input offset voltage is specified at ±200 µV, while input offset drift is ±2 µV/°C. The 106 dB CMR figure suppresses common-mode interference, and the wide ±18 V supply range permits operation with both positive and negative supply rails when the measurement circuit requires bipolar input or output signals. The device combines a low-noise input stage with a gain range of 1 to 10,000 V/V. The 600 kHz bandwidth supports measurement signals extending from slow process-control quantities through higher-bandwidth sensor and communications signals. A low nonlinearity error of 0.001% is important when preserving amplitude accuracy through a substantial gain range. The internal three-op-amp design also simplifies implementation by integrating the gain-setting resistor network. Typical uses include bridge-transducer amplification, precision current measurement, laboratory instrumentation, biomedical signal acquisition, industrial sensor interfaces, and low-level differential sensing. The very low bias current makes the amplifier appropriate for photodiode, electrochemical-cell, and other high-output-impedance sources. The negative and positive supply capability is valuable for bipolar sensor outputs and offset signals around ground. When designing around the INA121PA, verify input and output common-mode limits under the intended supply combination, including unbalanced ±18 V operation. Place the gain-setting resistor directly across the designated pins, maintain short input paths to minimize leakage and noise pickup, and use appropriate supply bypassing near the device. Check the complete operating region because gain, supply voltage, output swing, and input common-mode range are interdependent. This product overview combines the manufacturer’s core electrical characteristics with practical design guidance, package details, and a drop-in replacement assessment. It also identifies the limits of equivalent parts so engineers can preserve the INA121PA’s ±4 pA bias current, 106 dB CMR, low-power operation, and 8-pin plastic-DIP footprint when qualifying alternatives.

RFQ تماس
INA121U - Low-Power FET Instrumentation Amplifier | Texas Instruments
INA121U

INA121U - Low-Power FET Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA121U is a low-power, FET-input instrumentation amplifier with one channel, ±4 pA input bias current, ±450 µA quiescent current, and a 600 kHz bandwidth in an 8-pin SOIC package. According to the verified product data, it supports a wide ±2.25 V to ±18 V supply range and is specified for a -40 °C to +85 °C industrial temperature range. Its instrumentation-amplifier architecture is intended for amplifying small differential sensor signals while rejecting large common-mode voltages. An instrumentation amplifier is a specialized analog amplifier that provides differential input, high input impedance, accurate differential gain, and strong common-mode rejection. The INA121 belongs to the broader hierarchy of operational amplifiers, analog amplifiers, signal-conditioning ICs, and semiconductors. Its three-op-amp design makes it suitable for bridge sensors, current measurements, biomedical instrumentation, and industrial sensor interfaces where the common-mode voltage may be much larger than the wanted signal. Verified features include low input offset voltage of ±200 µV, low input offset drift of ±2 µV/°C, high common-mode rejection of 106 dB, and low nonlinear-ty error of 0.001%. The input-noise specification is listed as 100 nV/√Hz in the verified search data. These characteristics support precision measurement by reducing offset error, drift, common-mode interference, and amplitude distortion. The device is identified as a one-amplifier, 8-SOIC instrumentation amplifier by DigiKey. The INA121’s low-power design is useful when system power is constrained or when added analog circuitry would otherwise increase overall power consumption. The wide supply range supports both low-voltage portable systems and higher-voltage industrial interfaces, although the actual signal and output headroom must remain within the device ratings. The ±450 µA quiescent-current value is especially relevant to battery-powered and distributed sensor systems. Typical applications include strain-gauge and load-cell bridges, thermocouple and temperature-sensor front ends, low-current measurement, biomedical instrumentation, industrial process monitoring, and general differential signal conditioning. The design should provide suitable input filtering, power bypassing, gain-setting resistors, and output-voltage headroom. Pin assignment, gain calculation, and common-mode limits should be confirmed from the manufacturer datasheet before layout release. This product data consolidates the verified manufacturer description, distributor package identification, feature snippets, and sourcing links for INA121U. Pricing tiers below use the distributor value explicitly available as of 2026-10-22; the LCSC listing is for the distinct INA121U/2K5 ordering variant and is not substituted for INA121U.

RFQ تماس
INA121UA - FET-Input Low Power INA | SOIC-8 | Texas Instruments
INA121UA

INA121UA - FET-Input Low Power INA | SOIC-8 | Texas Instruments

The Texas Instruments INA121UA is a FET-input, low-power instrumentation amplifier (INA) that delivers excellent DC accuracy for general-purpose precision signal conditioning, housed in an 8-pin SOIC (D) package. Headline specifications are 600 kHz bandwidth (G = 100), 70 kHz small-signal bandwidth at unity gain, 0.07 V/us slew rate, 4 pA maximum input bias current, and a wide +/-2.25 V to +/-18 V dual supply range. The internal three-op-amp topology is externally gain-programmed with a single resistor from 1 V/V to 10,000 V/V, eliminating the need for matched external networks. An instrumentation amplifier is a precision differential amplifier that combines high input impedance, high common-mode rejection ratio (CMRR), and user-settable gain, making it ideal for extracting small differential signals riding on large common-mode voltages. Within the signal-chain taxonomy, the INA sits between the transducer/bridge and the analog-to-digital converter (ADC), and is itself a category of analog amplifier IC that subclasses under operational amplifier ICs (op-amp IC). The INA121 specifically targets FET-input applications where source impedance is high or where bias current must be minimized to avoid error and self-heating. Key features include +/-200 uV maximum input offset voltage, +/-2 uV/degrees C input offset drift, 100 nV/sqrt(Hz) low input noise voltage density, 106 dB minimum CMRR, and a low 450 uA typical quiescent current. The device also integrates input protection that can withstand up to +/-40 V differential or common-mode overvoltages without damage, and an output stage capable of driving 1 kohm loads to within 1.5 V of either supply rail. Internally, the INA121 uses a precision thin-film resistor network with laser-trimmed matching to deliver 0.001% maximum nonlinearity at G = 100. The FET front-end keeps bias current roughly two orders of magnitude lower than bipolar-input instrumentation amplifiers such as the AD620, which simplifies thermal management of high-impedance sensor sources. Typical applications include weigh scales and load-cell bridges, ECG/biopotential front-ends, thermocouple and RTD signal conditioning, industrial process controls with 4-20 mA loops, and battery-powered portable instrumentation. The wide supply range allows direct operation from industrial +/-15 V rails as well as low-voltage single-supply configurations down to 4.5 V total. When designing with the INA121UA, place the gain-setting resistor as close as possible to the RG pins to minimize parasitic capacitance, and provide 0.1 uF ceramic bypass capacitors within 5 mm of each supply pin. For single-supply operation, reference the output to mid-rail (VREF = VS/2) and bias the input common-mode voltage above ground by at least 1 V to preserve linear operation. Compared with monolithic zero-drift alternatives, the INA121 trades chopper-stabilized offset for higher bandwidth and lower quiescent current, making it preferred when AC signal fidelity matters more than nano-volt DC accuracy. This page synthesizes distributor pricing, same-brand and cross-brand drop-in alternatives, and practical design notes not found on the manufacturer datasheet front page.

RFQ تماس
INA121UAG4 - Low-Power FET Instrumentation Amplifier | Texas Instruments
INA121UAG4

INA121UAG4 - Low-Power FET Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA121UAG4 is a FET-input, low-power instrumentation amplifier designed for precision differential-signal measurement. The device provides a 1 V/V to 1000 V/V programmable gain range, operates from a 4 V to 36 V supply, and is packaged in an 8-pin SOIC. Its low input bias current, high input impedance, and common-mode rejection support accurate measurement of weak sensor signals in industrial and scientific equipment. An instrumentation amplifier is a differential amplifier optimized for amplifying a small voltage difference between two inputs while rejecting common-mode voltage. The INA121 belongs to the broader hierarchy of differential amplifiers, analog signal-chain ICs, and amplifiers used within electronic instrumentation. Its three-op-amp architecture provides precision differential amplification in a compact surface-mount package without requiring separate precision resistor networks. The INA121's principal benefits include programmable gain from 1 V/V to 1000 V/V, low quiescent current, low input offset voltage, and high common-mode rejection ratio. The internal gain-setting resistor allows the gain to be selected with one external resistor while preserving the small package size. These characteristics are useful when the measured differential voltage is much smaller than the voltage common to both input terminals. The INA121 uses a three-op-amp signal architecture with FET-input stages to provide high input impedance. The differential input is amplified according to the selected external gain resistor, while internal feedback networks reject common-mode voltage and improve gain accuracy. Input protection and feedback arrangements should be checked against the operating input range before connecting sensors whose outputs may exceed the electrical limits. Typical uses include bridge-transducer measurement, current sensing, biomedical instrumentation, portable measurement equipment, and industrial sensor interfaces. The device can also amplify differential voltages in test and measurement systems when its input, output, supply, and common-mode limits are respected. Its surface-mount package supports compact analog front ends but requires careful grounding and stable reference arrangements. For best results, place the gain-setting resistor close to the gain pin, connect the reference connection to a low-impedance ground for unipolar output or to a precision midpoint for bipolar output, and provide adequate supply bypassing. Output-voltage headroom, common-mode range, input bias-current effects, and resistor tolerance must all be considered when defining the usable measurement range. This page combines the manufacturer product information, lifecycle and package details, sourced cross-reference candidates, application guidance, and practical design considerations. It also distinguishes confirmed package and lifecycle facts from electrical parameters that require direct confirmation against the current Texas Instruments datasheet before a new design is released.

RFQ تماس
INA122P - 36V Micropower Instrumentation Amplifier | TI
INA122P

INA122P - 36V Micropower Instrumentation Amplifier | TI

The Texas Instruments INA122P is a precision, low-noise instrumentation amplifier for accurate differential signal acquisition, featuring 60 µA quiescent current, operation from 2.2 V to 36 V, and an 8-pin plastic DIP package. Its two-op-amp architecture supports single- and dual-supply operation, making it suitable for portable medical equipment, data-acquisition systems, and low-level transducer interfaces. The device is designed for accurate measurement of small differential signals while maintaining low power consumption. An instrumentation amplifier is a specialized amplifier category that measures the voltage difference between two input signals while rejecting common-mode noise. INA122P belongs to the broader hierarchy of instrumentation amplifier, differential amplifier, amplifier IC, and analog signal-conditioning IC. This position allows the device to sit between a sensor and an ADC or measurement system, where weak sensor outputs must be amplified without allowing the common-mode voltage to corrupt the result. Key features include a 60 µA low quiescent current, single-supply operation up to 36 V, dual-supply operation up to ±18 V, a common-mode range extending to V− − 0.1 V, and rail-to-rail output swing. The verified manufacturer data also identifies low offset voltage, low offset drift, and low noise as important characteristics for precision measurements. These features support battery-powered and portable systems where power consumption, input range, and signal fidelity are primary design constraints. The two-op-amp design provides accurate, low-noise differential acquisition in a single integrated circuit. Unlike a general-purpose op-amp used with a manually matched resistor network, the INA122P integrates the differential signal-conditioning function and is intended for applications such as bridges, load cells, thermocouples, and other low-level transducers. The common-mode and output-swing characteristics allow the amplifier to operate near the lower supply rail, which is useful in single-supply sensor systems. Typical applications include portable medical monitoring, industrial data acquisition, battery-powered instrumentation, bridge and load-cell signal conditioning, thermocouple interfaces, and low-level sensor measurement. In each case, the device can amplify a differential sensor signal while its low quiescent current helps preserve battery life. Designers should still verify input common-mode limits, output swing, gain configuration, supply range, and external resistor or capacitor requirements against the manufacturer datasheet. A key design consideration is maintaining adequate supply headroom and correct gain-setting components. Input and output signal ranges must remain within the specified common-mode and swing limits at every temperature and load condition. Place the device close to the sensor source when possible to reduce noise pickup, and follow the manufacturer datasheet for decoupling, gain resistor selection, grounding, and input protection. This page combines the verified Texas Instruments datasheet information, distributor listing data, and application-oriented engineering guidance for engineers evaluating the INA122P. It also distinguishes exact INA122 family packaging variants from unverified substitutes, helping PCB designers avoid assuming that different packages or amplifier families are drop-in compatible.

RFQ تماس
INA122PA - 60uA Micropower Instrumentation Amplifier, 36V | Texas Instruments
INA122PA

INA122PA - 60uA Micropower Instrumentation Amplifier, 36V | Texas Instruments

The Texas Instruments INA122PA is a single-channel, low-power instrumentation amplifier with 60 uA quiescent current, a 2.2 V to 36 V single-supply (or plus/minus 18 V dual-supply) operating range, and programmable gains from 5 V/V to 10,000 V/V, packaged in an 8-pin PDIP (P) package. It adds differential input measurement with high input impedance to low-level sensor signals while drawing very little supply current. An instrumentation amplifier (INA) is a precision differential amplifier optimized for sensing small signals buried in noise and common-mode interference. Structurally it sits above an operational amplifier, which itself sits inside the broader family of analog signal-chain amplifiers. The INA122 uses a two-op-amp architecture with excellent performance and very low quiescent current, so the hierarchy is instrumentation amplifier to difference amplifier to operational amplifier to analog IC, with the INA122 designed for portable instrumentation and data-acquisition systems. Key specifications include a low quiescent current of 60 uA, a wide power-supply range reaching 36 V on a single supply, a common-mode range of (V-) minus 0.1 V, and a rail-to-rail output swing. Input offset voltage is specified at 250 uV maximum and input offset drift at 3 uV/degC maximum, which keeps gain error and drift low at high gain settings. The device offers 120 kHz bandwidth and 90 dB common-mode rejection, so high-frequency common-mode noise and gain-bandwidth-limited signals are both well controlled. Technically, the two-op-amp topology gives a gain set entirely by one external resistor connected between the RG pins. That means the gain equation is set by a single component value rather than a matched resistor network, which simplifies calibration and keeps the design robust across temperature. Internal feedback resistors are laser trimmed, so CMRR and offset behavior stay consistent without external trimming. Typical uses include bridge and load-cell front ends, thermocouple and RTD signal conditioning, battery-powered portable medical monitors, current-shunt measurement in power supplies, and general-purpose low-level data acquisition front ends where both low quiescent current and wide supply range matter. When designing around the INA122PA, plan the RG resistor network for the lowest gain you can tolerate, place input filtering close to the pins, and note that the input common-mode range sits close to the negative rail, so the signal must remain above (V-) minus 0.1 V. Reference and supply decoupling capacitors should be placed adjacent to pins 5 and 7 for stable operation. This page consolidates manufacturer specifications, drop-in PDIP-8 alternatives, comparison data and practical design notes into one engineering reference that goes beyond a single datasheet download.

RFQ تماس
INA122PAG4 - Low-Power Instrumentation Amplifier | Texas Instruments
INA122PAG4

INA122PAG4 - Low-Power Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA122PAG4 is a single-supply, micropower precision instrumentation amplifier designed for accurate differential-signal acquisition. It operates from 2.2 V to 36 V, consumes approximately 60 µA of quiescent current, and is offered in an 8-pin PDIP package. The two-op-amp architecture provides a high-impedance differential input suitable for sensors, transducers, and low-level bridge signals. An instrumentation amplifier is a specialized amplifier that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. Its internal resistor arrangement and two-op-amp topology provide accurate gain control, low offset voltage, and strong common-mode rejection. The INA122 extends this architecture into a micropower package, making it particularly appropriate for portable medical instruments, battery-powered data-acquisition systems, and other low-power measurement equipment. The INA122 can operate from either a single positive supply or dual supplies. Its 2.2 V minimum operating voltage supports low-voltage portable systems, while the 36 V maximum rating provides flexibility in industrial and instrumentation circuits. The approximately 60 µA quiescent current limits the static power requirement and helps conserve battery capacity when continuous signal acquisition is required. Gain is set by an external resistor, allowing the circuit designer to select the sensitivity required for the sensor or measurement system. Because this is an instrumentation amplifier, input impedance remains high across the differential signal path, helping minimize loading of high-impedance sources. The device is intended for precision acquisition rather than high-speed waveform amplification, making it particularly suitable for slow sensor signals, strain-gauge bridges, biomedical instrumentation, and general-purpose data acquisition. A practical design must keep input and output voltages within the device's operating limits and provide adequate bypassing around the supply pins. Input common-mode voltage and output swing are constrained by the selected supply configuration, so system-level headroom should be checked before scaling a sensor output. The external gain resistor should be located close to the gain-setting pin to limit parasitic resistance and preserve gain accuracy. The INA122PAG4 is also suited to portable measurement systems where low quiescent current is more important than high bandwidth. Its compact 8-pin PDIP package is easy to prototype and inspect, making it useful for laboratory instruments, educational equipment, medical monitoring prototypes, and low-channel-count acquisition boards. This page combines the manufacturer specifications, package information, sourcing guidance, application guidance, and a practical comparison framework for engineers evaluating the INA122 and compatible instrumentation-amplifier options.

RFQ تماس
INA122U - 36V Micropower Instrumentation Amplifier | TI
INA122U

INA122U - 36V Micropower Instrumentation Amplifier | TI

The Texas Instruments INA122U is a precision, low-power instrumentation amplifier with a 2.2 V to 36 V supply range, 60 µA typical quiescent current, and an 8-pin SOIC package. Designed for differential signal acquisition, it uses a two-op-amp architecture to provide accurate amplification of low-level sensor signals while operating from either a single supply or dual supplies. The device is suitable for portable medical instrumentation, data acquisition systems, industrial sensing, and low-power measurement equipment. What is an instrumentation amplifier? An instrumentation amplifier is a differential amplifier optimized for measuring a small voltage difference between two inputs while rejecting common-mode interference. In the signal-chain hierarchy, an instrumentation amplifier sits between a sensor and a higher-level processing circuit; it provides gain, input impedance, and common-mode rejection in one dedicated analog block. Unlike a general-purpose operational amplifier, an instrumentation amplifier is intended for differential sensing and often preserves signal integrity when large common-mode voltages are present. Key features of the INA122U include a low quiescent current of 60 µA, wide supply operation from 2.2 V to 36 V, a common-mode range extending to (V−) − 0.1 V, rail-to-rail output swing, low offset voltage of 250 µV maximum, low offset drift of 3 µV/°C maximum, and low noise. The 8-SOIC package supports conventional surface-mount assembly and is identified by DigiKey as a one-circuit instrumentation amplifier. The two-op-amp architecture provides a straightforward gain-setting network while keeping the device suitable for portable and low-power systems. The INA122U is designed for accurate, low-noise differential signal acquisition rather than high-speed waveform processing. Its supply flexibility allows operation from a compact single supply or from dual supplies up to ±18 V, depending on the application requirements. The low 60 µA quiescent current helps limit battery drain when the amplifier is part of a portable instrument. Typical applications include low-level sensor front ends, portable medical monitoring, strain and pressure measurement, battery-powered data acquisition, current sensing, and industrial process instrumentation. The device is particularly useful when a small differential signal must be amplified before conversion by an ADC. In these systems, the engineer should verify the selected gain against the input range, common-mode voltage, output swing, supply voltage, and settling requirements. The main design consideration is ensuring that the input and output signals remain within the device's electrical limits while the external gain network is selected correctly. Input filtering, proper grounding, stable reference connections, and PCB trace symmetry help preserve differential accuracy. The INA122U combines low power, flexible supply operation, and precision-oriented specifications in a compact package for portable and measurement applications. This page summarizes the verified manufacturer information, distributor listing, practical application guidance, and available comparison context for engineers evaluating INA122U. Because detailed gain-current, noise-density, bandwidth, and package-temperature data are not all present in the supplied source material, those values should be confirmed against the current Texas Instruments datasheet before final design release.

RFQ تماس
INA122UA - 36V Micropower Instrumentation Amplifier | Texas Instruments
INA122UA

INA122UA - 36V Micropower Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA122UA is a single-supply, micropower precision instrumentation amplifier rated for supply voltages from 2.2 V to 36 V, featuring a 60 uA quiescent current, a bandwidth of 120 kHz, and an 8-pin SOIC package. Designed for differential signal acquisition, it provides low offset voltage and low offset drift while consuming minimal power. The device can operate from either a single positive supply or a dual supply, making it suitable for portable medical equipment, battery-powered instruments, and distributed data-acquisition systems. An instrumentation amplifier is a specialized analog signal-conditioning amplifier that measures the voltage difference between two inputs. Its internal differential architecture rejects common-mode interference, while programmable gain amplifies weak sensor signals before they reach an ADC. Within the broader hierarchy, the INA122UA is an instrumentation amplifier, analog amplifier, signal-conditioning IC, and power-management-compatible analog semiconductor designed for low-voltage precision acquisition. Key features include a 60 uA typical quiescent current, a wide single-supply operating range extending to 36 V, and operation from dual supplies up to plus or minus 18 V. The input common-mode range can extend approximately 0.1 V below the negative supply, and the output supports rail-to-rail swing. Maximum offset voltage is 250 uV, while maximum offset drift is 3 uV per degree Celsius, supporting stable measurements where sensor baselines change with temperature. The INA122UA uses a two-op-amp instrumentation-amplifier architecture to provide accurate, low-noise differential acquisition. Its gain is established by an external resistor, allowing the signal chain to be scaled without sacrificing input impedance or common-mode rejection. The 120 kHz bandwidth supports low-frequency industrial, biomedical, and instrumentation signals, but it is not intended for high-speed signal capture. Exact gain limits, noise density, input impedance, and common-mode rejection values require confirmation in the manufacturer datasheet. Typical applications include portable ECG and physiological-signal front ends, industrial pressure and temperature sensors, low-current transducers, laboratory measurement systems, and battery-operated data loggers. In each case, the device combines a broad supply range with low quiescent current, helping preserve battery life while accepting sensor outputs that require common-mode rejection. A key design consideration is the interaction between common-mode range, output swing, gain, and supply voltage. The input and output operating regions must remain valid during startup, sensor faults, and maximum signal excursions. Input filtering, source impedance balancing, and careful grounding are also important when offset and noise-sensitive measurements are required. This page consolidates the verified manufacturer and distributor information for the INA122UA with package guidance, pricing availability notes, application analysis, and carefully qualified replacement considerations. Because the supplied records do not include complete numerical pricing or a complete pin map, those details are identified as unavailable rather than inferred.

RFQ تماس
INA125P - Precision Bridge Amplifier with 10V Reference | Texas Instruments
INA125P

INA125P - Precision Bridge Amplifier with 10V Reference | Texas Instruments

The Texas Instruments INA125P is a low-power, high-accuracy instrumentation amplifier with a built-in precision voltage reference, maximum input offset voltage of 250 µV, slew rate of 0.02 V/µs, bandwidth of 150 kHz, and a 16-pin plastic through-hole DIP package. It provides differential bridge amplification and excitation from one integrated circuit. An instrumentation amplifier is a precision analog amplifier optimized for measuring small differential signals while rejecting large common-mode voltages. In the signal-chain hierarchy, the INA125P belongs to the instrumentation-amplifier class, then analog signal-conditioning amplifiers, then amplifiers and integrated analog ICs. Its internal three-op-amp-style signal conditioning is particularly useful for resistive sensors whose outputs are small, differential, and referenced to a bridge supply. Key features include a low 460 µA typical quiescent current, a 10 V precision reference, sleep-mode shutdown, low input bias current, and an industrial temperature range of -40°C to +85°C. The integrated reference can excite a bridge directly, while the differential amplifier rejects common-mode voltage present on both sensor inputs. Sleep mode supports duty-cycle operation and can reduce supply demand when measurements are not continuously required. The verified distributor data identifies a 2.7 V to 36 V supply capability, while another distributor result describes operation from 1.35 V to ±18 V. The manufacturer describes the device as usable in single-supply or dual-supply arrangements, subject to the detailed datasheet limits. The 150 kHz bandwidth and 0.02 V/µs slew rate support low-to-moderate-frequency measurements where fast settling is less important than low offset and low power. Typical uses include load-cell signal conditioning, strain-gauge bridge measurements, pressure-transducer interfaces, industrial weighing systems, and portable sensor instrumentation. The internal 10 V reference is particularly valuable when the sensing bridge needs excitation and a compact analog front end is preferred. When designing around the INA125P, check the selected gain, reference configuration, supply voltage, input common-mode range, and output swing against the manufacturer datasheet. Decoupling capacitors should be placed close to the supply pins, and the sensor return should be connected with care to preserve differential accuracy. The 16-pin DIP package is through-hole and is not mechanically interchangeable with the SO-16 variant. This page consolidates verified manufacturer and distributor information, package distinctions, application guidance, pricing context, and replacement-search results. It distinguishes confirmed drop-in evidence from unavailable alternatives rather than presenting unverified substitutions.

RFQ تماس
INA125PA - 10V Reference Bridge Amplifier | Texas Instruments
INA125PA

INA125PA - 10V Reference Bridge Amplifier | Texas Instruments

The Texas Instruments INA125PA is a single-channel instrumentation amplifier with an integrated 10 V precision voltage reference, differential input amplification, and bridge-excitation capability in a 16-pin PDIP package. It supports externally selected gains from 4 to 10,000, operates from 1.35 V to 18 V, and provides a typical bandwidth of 150 kHz. The device is designed for low-power measurement systems requiring accurate amplification of small differential signals. An instrumentation amplifier is a specialized amplifier IC that converts a low-level differential signal into a single-ended or differential output. Its internal architecture rejects common-mode noise while amplifying the voltage difference between two inputs. In the power-management and signal-chain hierarchy, an instrumentation amplifier is an amplifier IC used for sensor-interface, bridge-measurement, and precision signal-conditioning applications. The INA125 adds an internal voltage reference capable of exciting resistive sensor bridges. The INA125PA provides a low quiescent current of 460 µA, a maximum low-frequency offset voltage of 250 µV, and maximum offset drift of 2 µV/°C. Its precision voltage reference is fixed at 10 V. A single external resistor sets the gain, allowing gains from 4 to 10,000 while avoiding the need for a resistor network. Low offset, low drift, and low power consumption make the device useful for battery-powered and precision industrial equipment. Internally, the amplifier combines a precision gain stage with an integrated reference and low-noise input network. The high gain range supports resistive bridges with relatively small differential outputs, while the 150 kHz bandwidth covers many temperature, pressure, force, and position sensing applications. Because this is athrough-hole PDIP device rather than a surface-mount package, it is especially convenient for prototype boards, educational instruments, legacy industrial controls, and repair assemblies. Typical uses include Wheatstone bridge excitation and measurement, load-cell signal conditioning, industrial pressure transducers, portable measurement instruments, and low-power sensor interfaces. The 10 V reference can bridge suitable high-impedance resistive networks, but the bridge and input network must remain within the device's supply, common-mode, and electrical limits. The broad gain range also permits direct measurement of small millivolt-level signals without a separate front-end amplifier. Designers should place the gain-setting resistor close to the gain resistor pins and use a stable, low-temperature-coefficient resistor when gain accuracy matters. Input filtering should preserve the required bandwidth, while supply bypassing should use short, low-inductance connections. Because the INA125PA includes a precision reference, designers must account for reference current loading when the 10 V output is used to power external circuitry. This page consolidates verified manufacturer and distributor information, explicit data gaps, practical design guidance, and a careful same-package replacement assessment. The supplied sources establish the INA125PA's core functionality but do not provide five verified pin-to-pin alternatives, so the replacement list is intentionally limited rather than padded with electrically different or differently packaged parts.

RFQ تماس
INA125PAG4 - Precision Instrumentation Amplifier | Texas Instruments
INA125PAG4

INA125PAG4 - Precision Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA125PAG4 is a single-circuit instrumentation amplifier with an integrated precision voltage reference, designed for accurate differential-input amplification and bridge excitation. The device combines a low-noise amplifier core, matched input stages, gain-setting resistors, and a reference output in one integrated circuit, making it useful for pressure, load-cell, strain-gauge, and other bridge-based measurement systems. The INA125PAG4 is offered in a 16-pin through-hole DIP package for industrial temperature-grade applications. An instrumentation amplifier is a specialized amplifier category designed to provide high input impedance, accurate differential gain, and excellent rejection of common-mode signals. This is especially important when a small sensor differential voltage is measured in the presence of a much larger common-mode voltage. The INA125PAG4 provides the internal gain network and precision reference needed for complete bridge excitation and signal conditioning, reducing the number of external precision components required in a measurement front end. The principal benefits of this device include integrated precision voltage-reference capability, differential input architecture, programmable gain using external resistors, and a single-ended output suitable for connection to analog-to-digital converters or control systems. The device is identified as a 1-circuit instrumentation amplifier in a 16-PDIP package. Its input offset voltage is listed as 500 microvolts, and its bandwidth is listed as 150 kHz. These characteristics support moderate-bandwidth industrial measurement systems where accurate signal amplification is more important than very high-speed conversion. The INA125 family is suitable for applications involving resistive bridges and other small differential signals. The integrated reference can provide a stable excitation voltage for a bridge, while the instrumentation amplifier rejects common-mode voltage and applies a selected gain to the differential sensor output. Designers should account for the input common-mode range, output voltage swing, reference accuracy, resistor tolerance, and supply requirements when selecting the operating gain and external network. Typical uses include industrial process monitoring, load-cell signal conditioning, strain-gauge bridges, pressure transducers, laboratory instrumentation, and embedded data-acquisition systems. In a bridge circuit, the transducer changes resistance according to the measured physical quantity, creating a differential voltage that the INA125PAG4 amplifies relative to the supplied excitation. The resulting analog signal can then be sampled by an ADC after appropriate filtering and level adjustment. For PCB implementation, use a clean analog ground strategy, route the differential input pair as a tightly matched pair, and keep the gain-setting and reference-related components close to the device. Verify the actual supply, common-mode, output-swing, and gain limits against the manufacturer datasheet before releasing the design. The DIP package also provides generous pin spacing for prototyping and through-hole assembly, although a surface-mount package is preferable when board area or production routing is a primary constraint. This page provides a structured view of the INA125PAG4's instrumentation-amplifier role, package characteristics, verified operating highlights, application guidance, and design considerations. It is intended to help engineers evaluate the device for bridge-sensing and precision analog measurement systems without overlooking the electrical limits that determine gain, bandwidth, and signal integrity.

RFQ تماس
INA125TDA1 - Precision Instrumentation Amplifier Die | TI
INA125TDA1

INA125TDA1 - Precision Instrumentation Amplifier Die | TI

The Texas Instruments INA125TDA1 is a single-circuit instrumentation amplifier with an integrated precision voltage reference, a maximum voltage gain of 10,000, a minimum common-mode rejection ratio of 107 dB, and a nominal bandwidth of 0.15 MHz, supplied in rectangular die form with 17 terminals. It is designed for precision differential-signal conditioning where high common-mode rejection, adjustable gain, and a low-noise reference are important. An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while rejecting signals common to both inputs. Within the amplifier hierarchy, an instrumentation amplifier is a differential amplifier optimized for high input impedance, accurate gain control, and excellent common-mode rejection. This makes it more useful than a general-purpose operational amplifier for sensor outputs, bridge circuits, and other systems where large common-mode voltages may coexist with a small differential signal. The INA125TDA1 provides a gain of up to 10,000, a minimum CMRR of 107 dB, and a nominal bandwidth of 0.15 MHz. Its integrated precision voltage reference can support bridge excitation and other measurement systems that require an internal reference. The listed maximum input bias current of 0.025 uA is also useful in high-impedance sensor applications because it minimizes disturbance of the source being measured. Internally, the device combines instrumentation-amplifier signal conditioning with a precision reference in one circuit. The broad gain range supports applications ranging from moderate-level sensor signals to millivolt-level inputs. Because gain and bandwidth trade against one another in practical signal chains, the usable bandwidth generally decreases at higher gains, so the selected gain must be checked against the required measurement bandwidth and settling behavior. Typical uses include load-cell and strain-gauge front ends, precision bridge measurement, low-level differential sensing, industrial instrumentation, and laboratory signal conditioning. The die format is particularly relevant to manufacturers that require bare-die assembly, wafer-level integration, or customized packaging rather than a standard leaded or surface-mount package. Design work should begin with the manufacturer's INA125 pin-description table and electrical-characteristics table because the exposed die requires assembly-specific bonding and the exact terminal assignments are critical. Designers should also verify gain-set resistor values, reference loading, supply headroom, output swing, input common-mode limits, and the bandwidth required at the selected gain before releasing a production design. This page combines the die-level device information, verified pricing record, functional family comparisons, and application-specific engineering guidance to support sourcing and design decisions. It distinguishes the bare-die INA125TDA1 from packaged INA125 devices and emphasizes why package, pinout, qualification, and thermal requirements must be verified during replacement planning.

RFQ تماس
INA125TDA2 - 10000:1 Instrumentation Amplifier | Texas Instruments
INA125TDA2

INA125TDA2 - 10000:1 Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA125TDA2 is a single-circuit instrumentation amplifier with an integrated precision voltage reference, a maximum voltage gain of 10000, and a 17-terminal bare-die package. It is designed for precision measurement systems that require differential signal amplification, high common-mode rejection, and adjustable gain. The device also provides a nominal gain-bandwidth product of 0.15 MHz and maximum nonlinearity of 0.004%. An instrumentation amplifier is a precision analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal architecture is designed to provide high input impedance, controlled differential gain, and strong rejection of common-mode interference. This makes instrumentation amplifiers distinct from general-purpose operational amplifiers and places them within the amplifier IC hierarchy used for sensor conditioning, bridge excitation, and high-precision signal acquisition. Key characteristics include a maximum voltage gain of 10000, minimum common-mode rejection ratio of 107 dB, nominal bandwidth of 0.15 MHz, and maximum nonlinearity of 0.004%. The integrated precision voltage reference supports applications that need a controlled reference in addition to differential amplification. The single-circuit implementation also reduces the number of separate amplifiers needed for one measurement channel. The INA125 architecture supports programmable gain through external components and is suited to analog front ends where signal gain must be selected according to sensor output and input range. Its high common-mode rejection is valuable when a low-level sensor signal is measured in the presence of system-level interference. Because the INA125TDA2 is supplied as bare die, final package options, pin assignments, bonding details, and production integration requirements must be confirmed directly with Texas Instruments before a PCB or multichip-module design is released. Typical applications include bridge-based pressure and force measurement, precision current sensing, laboratory instrumentation, industrial sensor interfaces, and medical monitoring circuits. In a bridge circuit, the device can amplify the small differential bridge voltage while rejecting much of the common excitation voltage and its associated noise. The integrated reference can also support excitation or signal-conditioning systems that require a stable, controlled reference. The most important design consideration is package integration because INA125TDA2 is a die rather than a standard molded package. Designers should obtain the manufacturer’s die-product documentation and bonding information before assigning pads, defining the footprint, or estimating assembly yield. Input filtering, reference bypassing, gain-setting resistors, and output settling should also be evaluated against the selected gain and measurement bandwidth. This page combines the identified electrical characteristics with application guidance, design considerations, sourcing information, and a transparent assessment of replacement options. The absence of confirmed pin-to-pin alternatives is itself important because a functionally similar amplifier in a different package is not a drop-in replacement.

RFQ تماس
INA125U - Precision Bridge Amplifier, 10V Ref | Texas Instruments
INA125U

INA125U - Precision Bridge Amplifier, 10V Ref | Texas Instruments

The Texas Instruments INA125U is a low-power, high-accuracy instrumentation amplifier with a precision 10V voltage reference, user-selectable gain from 4 to 10,000, and a 16-pin SOIC package. It combines bridge excitation and differential-input amplification on one integrated circuit, making it suitable for strain-gauge, pressure-transducer, and other bridge-sensor signal chains. An instrumentation amplifier is a specialized differential amplifier designed for sensors whose useful output is small and appears across two input terminals. Its internal architecture provides high input impedance, accurate differential gain, and strong common-mode rejection. The INA125 adds a precision reference output, allowing a bridge circuit to be excited and its output measured relative to a stable midpoint. The INA125U offers a 2.7V to 36V supply range, low 460µA quiescent current, maximum 250µV input offset voltage, maximum 2µV/°C offset drift, and a sleep mode. A single external resistor sets the gain, while the integrated amplifier can provide 150kHz bandwidth according to the retrieved product data. These features balance precision, power consumption, and measurement speed for portable and industrial instrumentation. Electrically, the device is intended for bridge outputs and other low-level differential sources. Input common-mode range, reference accuracy, gain error, and maximum input voltage must be checked against the actual bridge excitation and sensor output. The SOIC package also requires careful attention to ground return paths and supply decoupling when low-level signals are measured. Typical uses include quarter-bridge and full-bridge strain sensors, load-cell front ends, pressure and force measurement, biomedical instrumentation, industrial process controls, and precision data-acquisition systems. The 10V reference can simplify excitation when the sensor and measurement chain require a defined bridge supply. The most important design consideration is preserving common-mode and differential signal integrity. Place input and reference grounding deliberately, use low-noise supply bypass capacitors, and verify that the selected gain resistor stays within its recommended range. This page combines verified manufacturer and distributor information with practical application guidance and explicit data gaps rather than estimating unprovided specifications.

RFQ تماس
INA125U/2K5 - Low-Power Precision Instrumentation Amplifier with 2.5V Reference
INA125U/2K5

INA125U/2K5 - Low-Power Precision Instrumentation Amplifier with 2.5V Reference

The Texas Instruments INA125U/2K5 is a low-power, high-accuracy instrumentation amplifier with an integrated precision voltage reference, delivered in a 16-pin SOIC package. It provides complete bridge excitation and precision differential-input amplification on a single integrated circuit, with gain set from 4 V/V to 10,000 V/V by one external resistor. Key headline figures are a 2.7 V to 36 V supply range (±18 V maximum total supply), an input bandwidth of 0.15 MHz, a 100 dB CMRR and 38 nV/√Hz input noise at 1 kHz, all in a 16-lead SOIC. An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals buried in noise and common-mode interference. The category hierarchy runs instrumentation amplifier -> differential amplifier -> amplifier IC -> integrated circuit -> semiconductor. Unlike a discrete op-amp difference stage, an INA offers high input impedance, matched resistors, excellent common-mode rejection and a single-gain-set resistor, which is why it dominates strain-gauge, bridge and ratiometric sensor front ends. Key features include a 50 uV maximum input offset voltage, a 2 uV/°C input offset voltage temperature coefficient, a 460 uA typical supply current for low-power designs, a 2 V/µs slew rate, and 60 µs settling time. The internal reference supplies a stable excitation voltage for bridge circuits, and an enable/shutdown pin supports power management. Overvoltage protection guards inputs during industrial transients. Technically, the device uses a three-op-amp topology with laser-trimmed internal feedback resistors, so gain accuracy depends only on the external gain resistor. The on-board precision reference makes ratiometric conversion with an ADC possible without a second supply, and the reference can also serve as an external excitation source. The single external gain resistor keeps the calibration chain short, which supports the 0.075% gain error class of the device. Typical applications include strain-gauge and load-cell front ends, isolated transmitter analog sections, bridge-powered sensor modules, medical monitoring instrumentation, and 4-20 mA loop signal conditioning where the reference eliminates a separate excitation supply. When designing around the INA125U/2K5, keep the gain resistor close to the RG pin and use the recommended supply bypassing. Because it is a linear amplifier with a wide supply range, excessive headroom at high gain costs power and heat; choose the smallest gain that meets the sensitivity target. This page consolidates distributor availability, drop-in same-family alternatives, parameter-by-parameter comparison, and practical layout notes that are not collected in a single place in the manufacturer datasheet.

RFQ تماس
INA125UA - Precision Bridge Instrumentation Amplifier | TI
INA125UA

INA125UA - Precision Bridge Instrumentation Amplifier | TI

The Texas Instruments INA125UA is a low-power, high-accuracy instrumentation amplifier with an integrated precision voltage reference, one differential input channel, and a 16-pin SOIC package. A single external resistor sets the gain from 4 to 10,000 V/V, while the integrated bridge excitation and reference circuitry support complete sensor-conditioning solutions in one IC. An instrumentation amplifier is a specialized analog signal-conditioning IC designed to amplify small differential voltages while rejecting common-mode interference. Its functional hierarchy is instrumentation amplifier, differential amplifier, analog front end, and signal-conditioning IC. This device is particularly useful when a sensor produces a small differential output and the measurement environment contains noise, ground-potential differences, or substantial common-mode voltage. The INA125UA combines differential-input amplification, adjustable gain, bridge excitation, and a precision voltage reference in one package. Its gain range of 4 to 10,000 V/V allows the same device family to serve strain-gauge, pressure-sensor, and resistive-bridge systems. The single-resistor gain-setting arrangement simplifies calibration and reduces the number of external components required for many precision measurement circuits. The device is laser-trimmed for accuracy, and the family operates across a supply range of 2.7 V to 36 V. The INA125UA ordering option is supplied in a 16-pin SOIC package for surface-mount assembly. The integrated reference can support excitation or output-referencing requirements where an external precision reference would otherwise increase component count and introduce another error source. Typical uses include strain-gauge load cells, resistive pressure and temperature sensors, current-shunt instrumentation, industrial process monitoring, and precision laboratory measurement systems. It is especially appropriate when differential signal integrity, adjustable gain, and integrated bridge excitation are needed within one analog front end. The wide supply range also allows operation from low-voltage portable systems through higher-voltage industrial measurement equipment. Designers should follow the TI datasheet for the exact gain-resistor equation, reference-output behavior, input and output range, supply decoupling, and common-mode limitations. Place bypass capacitors close to the supply pins, keep sensitive differential routes compact and symmetric, and verify that transducer excitation, input common-mode voltage, output swing, and gain remain within their permitted operating limits. This page organizes the INA125UA specifications, pin package, application guidance, comparison parameters, and drop-in alternatives. It also identifies the engineering trade-offs between same-footprint family members and provides sourcing workflows for price, availability, and lead-time requests.

RFQ تماس
INA126P - 36V MicroPower Precision INA | Texas Instruments
INA126P

INA126P - 36V MicroPower Precision INA | Texas Instruments

The Texas Instruments INA126P is a precision micropower instrumentation amplifier rated for a 36 V maximum supply, with 175 µA quiescent current, 250 µV input offset voltage, and gain values set by an external resistor. It is supplied in an 8-pin PDIP package for through-hole industrial, portable, and measurement-instrumentation designs. An instrumentation amplifier is a differential analog-front-end IC that amplifies the voltage difference between two inputs while rejecting common-mode interference. INA126 belongs to the instrumentation-amplifier hierarchy within operational amplifiers and analog signal-chain ICs. Its two-op-amp architecture supports accurate, low-noise acquisition from sensors, bridges, and low-level transducers, especially where power consumption and input precision are important. The verified features include 250 µV offset, 175 µA typical quiescent current, and operation from ±1.35 V to ±18 V, corresponding to a stated 36 V maximum supply condition. The INA126 family also provides programmable gains of 1, 10, 100, or 1000 through the external gain resistor. These values make it suitable for battery-powered instrumentation, industrial measurement, portable diagnostics, and sensor interfaces where common-mode rejection and low bias current are more valuable than wide bandwidth. The device uses a two-op-amp internal architecture rather than a three-op-amp topology, helping keep power consumption low. Because the gain depends on the external resistor and its matching, PCB resistor placement, source impedance balance, input filtering, grounding, and reference-connection practices directly influence accuracy. The 8-pin PDIP package is mechanically straightforward for through-hole assembly but requires adequate lead spacing and clean soldering practice. Typical applications include bridge-based pressure and load measurement, low-level sensor conditioning, portable medical or industrial instrumentation, battery-operated data acquisition, and differential signal acquisition where a precision offset and low supply current are required. For single-supply systems, the output-reference arrangement must be designed to keep the output within the input and output common-mode limits. The principal design trade-off is the relatively modest micropower-focused feature set versus higher-bandwidth or lower-noise instrumentation amplifiers. Confirm supply voltage, input range, gain resistor, output swing, reference connection, and common-mode limits against the manufacturer datasheet before committing a PCB design. This page combines verified manufacturer and distributor information with design guidance, selection criteria, and same-package comparison context for engineers evaluating the INA126P.

RFQ تماس
INA126PA - 36V Micropower Instrumentation Amplifier | TI
INA126PA

INA126PA - 36V Micropower Instrumentation Amplifier | TI

The Texas Instruments INA126PA is a single-channel, precision micropower instrumentation amplifier with a 36 V maximum supply rating, 250 µV input offset voltage, 175 µA quiescent current per channel, and an 8-pin PDIP package. It is designed to acquire accurate, low-noise differential signals while consuming very little power. The two-operating-amplifier architecture supports common-mode rejection and differential signal conditioning in compact, portable, and industrial instrumentation systems. An instrumentation amplifier is a specialized amplifier category used to amplify the difference between two input signals while rejecting common-mode voltage. Within the amplifier hierarchy, an instrumentation amplifier is a precision analog amplifier, while an operational amplifier is a more general-purpose building block. The INA126PA belongs to the micro-power instrumentation-amplifier family and combines differential input measurement, adjustable gain, and low bias current in one integrated circuit. The principal advantages are low power consumption, low offset voltage, a wide operating-supply range of ±1.35 V to ±18 V, and operation from a single supply down to 2.7 V. According to the manufacturer datasheet, the device uses 175 µA per channel and provides a gain adjustment range of 1 V/V to 1000 V/V. These characteristics suit battery-powered and portable measurement systems where amplifier power can materially affect available operating time. The INA126PA uses a two-operating-amplifier architecture for accurate, low-noise differential-signal acquisition. Its instrumentation-amplifier function is useful when the wanted signal is smaller than the voltage shared by both input nodes. The low 175 µA quiescent current is particularly important in portable instrumentation and data-acquisition systems, while the 250 µV offset specification supports precision measurement of small differential voltages. Typical applications include portable sensor acquisition, industrial process measurement, battery-operated diagnostic equipment, low-current transducers, and differential voltage sensing. In each case, the device can condition a low-level differential input before it reaches an ADC or another signal-processing stage. Its single- and dual-supply flexibility allows it to be used with compact analog systems operating from low-voltage sources as well as higher-voltage industrial rails. Designers should verify the exact gain-setting resistor against the manufacturer gain table and preserve the input and reference-pin arrangements shown in the datasheet. The reference input should be connected to a defined low-impedance voltage, and unused inputs must not be allowed to float. PCB layout should keep the gain-setting resistor close to the device to minimize added noise and instability in sensitive measurement circuits. This product page consolidates verified manufacturer and distributor information, lifecycle guidance, package details, replacement analysis, and practical design guidance. It also distinguishes verified drop-in candidates from changes requiring a different package, helping engineers avoid confusing functional equivalence with literal PCB-level replaceability.

RFQ تماس
INA126U - 36V Micropower Instrumentation Amp | Texas Instruments
INA126U

INA126U - 36V Micropower Instrumentation Amp | Texas Instruments

The Texas Instruments INA126U is a single-circuit micropower precision instrumentation amplifier rated for a 36 V total supply, with 175 µA quiescent current per channel, 250 µV offset, and an 8-pin SOIC package. Its differential-input architecture supports accurate, low-noise signal acquisition where common-mode interference, source impedance mismatch, and power consumption must all be controlled. An instrumentation amplifier is a specialized amplifier and the final member of the signal-chain hierarchy: sensor output → differential input → instrumentation amplifier → ADC or measurement system. Unlike a general-purpose operational amplifier, an instrumentation amplifier internally supports high input impedance and accurate differential gain, reducing errors when both inputs originate from balanced sensors, resistive bridges, or shunt measurements. The INA126 family uses a two-op-amp architecture optimized for precision and micropower operation. Verified headline features include a 36 V maximum supply, 175 µA per-channel quiescent current, and 250 µV offset. The manufacturer describes the device for accurate, low-noise differential-signal acquisition across a wide operating voltage range of ±1.35 V to ±18 V. These properties suit portable instruments and low-power acquisition systems where battery energy is limited but input-referred accuracy remains important. The single amplifier in the INA126U also avoids the extra power and board area associated with an unnecessary dual channel. The INA126U can be configured through an external gain-setting resistor. Because its instrumentation-amplifier architecture rejects common-mode signals before they reach the output, it is particularly useful when the wanted differential signal is much smaller than the voltage shared by both inputs. Designers must still verify input and output common-mode limits, maximum differential input voltage, gain-bandwidth behavior, resistor tolerance, output swing, and the sensor output range for the intended supply voltage. Precision performance ultimately depends on resistor matching and careful grounding as well as the amplifier itself. Typical uses include battery-powered sensor interfaces, portable measurement instruments, current-shunt amplifiers, bridge-signal conditioning, and low-power data-acquisition front ends. The 175 µA per-channel quiescent current is particularly useful where idle current directly affects battery life. The 250 µV offset specification gives designers a defined input-referred error reference, while the 36 V supply capability supports higher-voltage industrial systems when the individual input and output ranges are observed. For PCB implementation, keep the external gain resistor close to the gain-setting pins, use a stable low-noise reference plane, and place input-protection capacitance only after checking its effect on bandwidth and transient response. Avoid long parallel input traces, maintain symmetric routing where practical, and provide local supply bypassing. Verify common-mode headroom at worst-case sensor voltage and load current rather than relying only on nominal supply conditions. This page combines verified manufacturer facts, distributor pricing, same-package alternatives, and application-oriented design guidance. It also distinguishes documented values from parameters requiring confirmation from the complete manufacturer datasheet, helping engineers move from component selection to a defensible low-power sensor-board design.

RFQ تماس
INA126U/2K5 - 36V MicroPower Instrumentation Amplifier | Texas Instruments
INA126U/2K5

INA126U/2K5 - 36V MicroPower Instrumentation Amplifier | Texas Instruments

Texas Instruments INA126U/2K5 is a precision, micropower instrumentation amplifier with a 36 V maximum supply voltage, 175 µA quiescent current, and 250 µV input offset voltage, supplied in an 8-pin SOIC package. Designed for low-level differential-signal acquisition, it combines a two-op-amp architecture with high input impedance and low power consumption for portable instrumentation, industrial measurement, and sensor-interface applications. An instrumentation amplifier is a specialized amplifier that measures the voltage difference between two inputs while rejecting common-mode voltage. Its place in the signal-chain hierarchy is sensor front end → instrumentation amplifier → precision analog signal chain. Unlike a general-purpose operational amplifier, an instrumentation amplifier provides purpose-built differential input handling and high common-mode rejection for bridges, sensors, and measurement systems. The INA126 family provides low quiescent current of 175 µA per channel and supports supply voltages from ±1.35 V to ±18 V. Its 250 µV offset specification supports accurate measurement of small differential signals, while the wide 36 V total supply range permits operation from compact dual supplies or a single supply when the signal and reference levels are compatible with the device architecture. The INA126 uses a two-op-amp instrumentation-amplifier topology rather than a three-op-amp configuration. This reduces circuit complexity and can reduce board area, while preserving the differential-input behavior required by precision measurement systems. The gain arrangement associated with the /2K5 ordering option distinguishes this version from other INA126 gain and package configurations, so the full ordering information should be checked before substituting a part in an existing design. Typical uses include bridge-transducer excitation and readout, battery-powered sensor acquisition, current measurement, industrial process monitoring, and portable medical or test equipment. Low quiescent current is particularly valuable when the amplifier must remain active while the overall instrument consumes little power. The 36 V supply capability also supports higher-voltage industrial measurement systems when appropriate input common-mode and output-range conditions are met. When laying out the circuit, use the pin-description table in the manufacturer datasheet for all connections and preserve the reference and supply decoupling arrangement shown by Texas Instruments. Input filtering, resistor placement, and guarding can materially affect accuracy in high-impedance sensor nodes. The output-reference connection should also be treated as part of the measurement system because its voltage influences the output level and can be used for bipolar-signal offsetting. This page combines the manufacturer product description, ordering distinctions, cross-reference findings, comparison guidance, and practical implementation advice. It highlights where the INA126U/2K5 fits in low-power precision acquisition and identifies the parameter checks engineers should complete before approving a replacement or redesign.

RFQ تماس