AD625AD نمای کلی

Analog Devices AD625AD is a precision programmable-gain instrumentation amplifier with user-programmed gains from 1 to 10,000, a 25 MHz gain-bandwidth product, and low-noise performance of 4 nV/√Hz at 1 kHz. The device is packaged in a 16-lead ceramic dual inline package identified as 16-CDIP, providing a durable through-hole format for precision signal-conditioning equipment.

An instrumentation amplifier is a specialized amplifier category designed to amplify small differential signals while rejecting common-mode interference. Its internal topology and external gain resistor make it particularly useful when input impedance, gain accuracy, and common-mode rejection must be maintained simultaneously. In the signal-chain hierarchy, the AD625AD belongs to the precision instrumentation-amplifier family within amplifier ICs and analog signal-conditioning components.

Key characteristics include a maximum low-gain error of 0.02%, maximum low-gain temperature coefficient of 5 ppm/°C, maximum low nonlinearity of 0.001%, and a maximum offset voltage of 200 µV. The 25 MHz gain-bandwidth product allows the closed-loop bandwidth to decrease as gain increases, making the amplifier suitable for both precision measurement and higher-frequency sensor interfaces.

The AD625AD uses an external gain-setting resistor to establish its programmed gain. Designers must calculate the required resistance from the device's gain equation and verify resistor tolerance, temperature coefficient, parasitics, and stability across the intended signal bandwidth. Its 4 nV/√Hz noise characteristic is particularly relevant when resolving low-amplitude transducer outputs without allowing amplifier noise to dominate the measurement.

Typical applications include bridge and strain-gage signal conditioning, biomedical instrumentation, laboratory measurement systems, precision current measurement, and industrial sensor interfaces. The 16-CDIP package is useful where a through-hole assembly and long service life are preferred over a surface-mount footprint, although the larger board area and through-hole thermal behavior must be considered in compact systems.

The primary design trade-off is bandwidth versus gain. The 25 MHz gain-bandwidth product supports a range of measurement speeds, but useful closed-loop bandwidth falls as the selected gain rises. Layout should therefore use short signal paths, a clean analog ground reference, and an external gain resistor positioned close to the gain-setting pin.

This page combines manufacturer specifications, lifecycle guidance, practical circuit-design considerations, sourcing information, and verified drop-in alternatives to support faster component evaluation and board-level planning.

جایگزین‌های drop-in برای AD625AD — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

گونه‌ها در این سری

مدل‌های هم‌سری که جایگزین مستقیم هستند برای AD625AD (همان فرم‌فاکتور و فوت‌پرینت) — متفاوت در Package, Product Type, Input Bias Current, RoHS Status, Slew Rate.

Analog Devices
Package: 16-CDIP, 0.300 inch pitch, 7.62 mm body
Product Type: Programmable gain instrumentation amplifier
Input Bias Current: 10 nA
مقایسه با AD625AD →
Analog Devices
Package: 16-pin PDIP
Product Type: Single-channel precision instrumentation amplifier
Input Bias Current: 30 nA
مقایسه با AD625AD →

AD625CDZ

✅ جایگزین مستقیم
Analog Devices
📦 16-CDIP
Instrumentation amplifier · 1 circuit · 25 MHz · 650 kHz · 5 V/us · 10 nA · +5 V · 16-CDIP, 0.300 inch pitch, 7.62 mm body

برای قیمت تماس بگیرید

مشاهده دیتاشیت ←

AD625AD حداکثر مقادیر مجاز و مشخصات الکتریکی

Product Type Programmable-gain instrumentation amplifier
Number of Circuits 1 circuit
User-Programmed Gain Range 1 to 10,000
Maximum Low-Gain Error 0.02% max
Maximum Low-Gain Temperature Coefficient 5 ppm/°C max
Maximum Low Nonlinearity 0.001% max
Maximum Offset Voltage 200 µV
Input Noise Density 4 nV/√Hz at 1 kHz
Gain-Bandwidth Product 25 MHz
Bandwidth 0.65 MHz
Architecture Bipolar
بسته‌بندی 16-CDIP
تعداد پایه 16 pins
نوع نصب Through-hole
Design Recommendation Not recommended for new designs
Data Sheet Revision Rev. D

راهنمای پیکربندی پین AD625AD 16-cdip

پیکربندی پین برای AD625AD (پکیج 16-cdip). این قطعه آنالوگ دارای پین‌های ورودی، خروجی و تغذیه است. برای پیکربندی‌های پین offset null، جبران‌سازی و فعال‌سازی به دیتاشیت سازنده مراجعه کنید. ایده‌آل برای مدارهای شرطی‌سازی سیگنال و تقویت‌کننده.

نمودار پین‌آوت پکیج 16-cdip برای AD625AD

داده پین‌آوت تفصیلی موجود نیست برای AD625AD.

به دیتاشیت برای پیکربندی کامل پین‌ها.

کاربردهای معمول

AD625AD مناسب است برای 6 کاربردs: Strain-Gage and Bridge Measurement, Biomedical Signal Conditioning, Precision Current Measurement, Laboratory Instrumentation, Industrial Sensor Interfaces, Low-Level Differential Signal Acquisition.

🏭

Strain-Gage and Bridge Measurement

The AD625AD fits strain-gage and resistive-bridge front ends that require substantial gain from small differential sensor outputs. Its programmable range extends to 10,000, while the maximum low-gain error of 0.02%, low-gain temperature coefficient of 5 ppm/°C max, and 4 nV/√Hz noise at 1 kHz support accurate signal recovery. Place the external gain-setting resistor close to the device, route the bridge and return paths differentially, and use a quiet analog ground. Because the 25 MHz gain-bandwidth product reduces usable bandwidth as gain rises, verify the required measurement bandwidth against the selected gain before finalizing the circuit.

💊

Biomedical Signal Conditioning

The AD625AD is appropriate for low-level biomedical instrumentation in which patient-derived or diagnostic signals must be amplified with controlled gain and low added noise. A gain of 1 to 10,000 allows the same amplifier family to cover multiple measurement ranges, and the 4 nV/√Hz input noise at 1 kHz helps avoid masking weak biosignals. Input protection, patient isolation, leakage current, and electrode-interface requirements must be handled separately from the amplifier itself. Keep high-gain interconnects short, shield sensitive routes where needed, and validate the complete analog chain for offset drift, nonlinearity, and common-mode behavior.

⚡

Precision Current Measurement

The AD625AD can amplify the differential voltage generated by shunt-based current measurements when high common-mode voltage must be rejected. Its precision characteristics include a maximum low-gain error of 0.02% and maximum low nonlinearity of 0.001%, which help preserve measurement-chain accuracy. The 16-CDIP package also provides a practical through-hole implementation for laboratory and industrial instrumentation. Select the external gain resistor carefully, account for its tolerance and temperature coefficient, and avoid routing high-current return paths beneath the analog input network. Confirm that the selected gain provides the required bandwidth within the 25 MHz gain-bandwidth-product constraint.

🔧

Laboratory Instrumentation

The AD625AD is well suited to laboratory measurement equipment requiring programmable gain, low offset, and flexible signal-range selection. Its gain can be set from 1 to 10,000 through an external resistor, while the 200 µV maximum offset voltage and 0.001% maximum low nonlinearity support precise front-end behavior. The device’s 25 MHz gain-bandwidth product supports a range of signal speeds, although bandwidth falls as gain increases. A practical instrument design should include calibration access, input attenuation or range switching, protection against external test faults, and a quiet reference plane to prevent switching currents from modulating the measured signal.

🏭

Industrial Sensor Interfaces

The AD625AD can condition low-level outputs from pressure, temperature, position, and resistance-based sensors when the interface requires a wide programmable gain range. The 4 nV/√Hz noise density at 1 kHz is valuable for low-amplitude sensors, while the 0.02% maximum low-gain error supports calibrated systems. Use the 16-CDIP footprint only where through-hole assembly, serviceability, and thermal rise are acceptable. Industrial environments also require attention to EMI, surge events, ground loops, and sensor-excitation noise; filtering and protection should be placed where they do not compromise the required signal bandwidth.

📡

Low-Level Differential Signal Acquisition

The AD625AD supports acquisition of weak differential signals that share a large common-mode voltage. Its instrumentation-amplifier configuration is intended to provide accurate gain over a broad 1-to-10,000 range, and the bipolar implementation supports the precision requirements of this measurement class. The 25 MHz gain-bandwidth product must be evaluated at each operating gain because higher gains reduce closed-loop bandwidth. Maintain symmetric input routing, minimize connector and trace leakage where relevant, and place the gain-setting component near the relevant device pin. For new production programs, account for the manufacturer’s not-recommended-for-new-designs lifecycle position before committing the architecture.

خلاصه محصولات پیشنهادی

AD624 Related precision instrumentation amplifier استفاده‌شده در: Strain-Gage and Bridge Measurement, Biomedical Signal Conditioning, Precision Current Measurement, Laboratory Instrumentation, Industrial Sensor Interfaces, Low-Level Differential Signal Acquisition AD524 Related programmable-gain amplifier استفاده‌شده در: Strain-Gage and Bridge Measurement, Biomedical Signal Conditioning, Precision Current Measurement, Laboratory Instrumentation, Industrial Sensor Interfaces, Low-Level Differential Signal Acquisition AD625CDZ Analog Devices استفاده‌شده در: Strain-Gage and Bridge Measurement, Precision Current Measurement, Low-Level Differential Signal Acquisition
What is the AD625AD?
The AD625AD is a precision, single-circuit, programmable-gain instrumentation amplifier manufactured by Analog Devices. According to the AD625 Data Sheet Rev. D, it supports user-programmed gains from 1 to 10,000, operates from bipolar circuitry, and is offered in a 16-CDIP package for through-hole signal-conditioning designs.
What are the key specifications of AD625AD that engineers should know?
The AD625AD combines gains from 1 to 10,000 with a 25 MHz gain-bandwidth product and 4 nV/√Hz input noise at 1 kHz. The Analog Devices AD625 Data Sheet Rev. D also specifies a maximum low-gain error of 0.02%, maximum low-gain temperature coefficient of 5 ppm/°C, maximum low nonlinearity of 0.001%, and maximum offset voltage of 200 µV.
Where can I download the AD625AD datasheet PDF?
The official AD625AD datasheet is available through the Analog Devices AD625 product page at https://www.analog.com/en/products/ad625.html. The manufacturer lists the AD625 Data Sheet as Rev. D and identifies AD625AD as a 16-CDIP instrumentation-amplifier orderable variant.
Where can I find the AD625AD pinout?
Use the pin-configuration and pin-description tables in the Analog Devices AD625 Data Sheet Rev. D for the complete 16-CDIP assignment. The component page at https://www.analog.com/en/products/ad625.html links directly to the manufacturer documentation, which is the authoritative source for assigning PCB tracks and connections.
What gain range does AD625AD support?
The AD625AD supports user-programmed gains from 1 to 10,000. According to the Analog Devices AD625 Data Sheet Rev. D, the gain is established with an external gain-setting resistor, allowing the same device family to address a broad range of sensor and measurement-amplifier signal levels.
How much bandwidth is available at higher gain on AD625AD?
The AD625AD has a 25 MHz gain-bandwidth product, so closed-loop bandwidth decreases approximately in inverse proportion to the selected gain. The Analog Devices AD625 Data Sheet Rev. D identifies a 0.65 MHz bandwidth characteristic, while the gain-bandwidth product supports higher small-signal response at lower programmed gains.
What is the noise performance of AD625AD?
The AD625AD provides input noise of 4 nV/√Hz at 1 kHz. According to the Analog Devices AD625 Data Sheet Rev. D, this low-noise characteristic helps preserve the integrity of small differential sensor signals and makes the amplifier suitable for precision bridge, strain-gage, and laboratory measurement interfaces.
What accuracy characteristics should be checked when designing with AD625AD?
The AD625AD is specified with a maximum low-gain error of 0.02%, a maximum low-gain temperature coefficient of 5 ppm/°C, and a maximum low nonlinearity of 0.001%. These figures come from the Analog Devices AD625 Data Sheet Rev. D and should be checked against the required measurement accuracy and calibration budget.
AD625AD vs AD625CDZ - which is better for a new design?
The AD625AD should be selected only when a legacy ceramic-DIP implementation requires continuity because Analog Devices marks the AD625 family as not recommended for new designs. The AD625CDZ is the identified same-package ceramic-DIP alternative, but engineers should review the current manufacturer documentation and qualification requirements before transferring a production design.
What can replace AD625AD on the same PCB?
The AD625CDZ is the closest identified same-package ceramic-DIP replacement candidate for the AD625AD. Its exact suitability depends on confirmation of pin compatibility, gain equation, supply requirements, temperature grade, and acquisition status against the Analog Devices AD625 Data Sheet Rev. D before production use.
Is AD625CDZ the same as AD625AD?
The AD625CDZ is a closely related AD625-series instrumentation amplifier in the same ceramic-DIP format, but it should not be treated as automatically identical without a pin-by-pin and specification review. Check the AD625 Data Sheet Rev. D for ordering codes, temperature grade, electrical limits, and documented package differences.
When should I choose AD625AD instead of AD625CDZ?
Choose the AD625AD when an established design specifies that exact orderable part or requires continuity with controlled internal procurement. For a genuinely new design, evaluate whether the AD625CDZ matches every electrical and mechanical requirement and whether a currently recommended instrumentation-amplifier family would better address lifecycle risk.
Is AD625AD suitable for strain-gage and bridge measurements?
The AD625AD is suitable for many strain-gage and bridge measurement circuits because it combines a gain range of 1 to 10,000, low-gain error of 0.02% max, and 4 nV/√Hz noise at 1 kHz. The analog front end still requires proper excitation, differential routing, grounding, shielding, and gain-resistor layout.
Where can I buy AD625AD online?
Use the Request a Quote form on this page to request AD625AD availability, current commercial terms, and a quotation. Because Analog Devices identifies the AD625 family as not recommended for new designs, purchasing review should also confirm lifecycle status, traceability requirements, and the number of units required.
What is the price of AD625AD?
Use the Request a Quote form on this page for the current AD625AD unit price and quantity terms. The structured commercial section tracks current quotations separately from technical documentation, and the manufacturer’s not-for-new-designs status makes lifecycle and traceability requirements important to confirm before ordering.
What is the lead time and stock status for AD625AD?
Request the current AD625AD stock, minimum order quantity, and lead time through the Request a Quote form on this page. The manufacturer marks the AD625 family as not recommended for new designs, so an availability answer should be tied to the exact AD625AD suffix and the quantity and quality requirements of the intended order.
Is AD625AD RoHS compliant?
The AD625AD RoHS status cannot be confirmed from the accessible product information and is therefore recorded as unknown. Review the current Analog Devices product documentation, material declarations, or applicable compliance records for the exact AD625AD orderable part before making a procurement compliance determination.

داده‌های مرجع مهندسی برای AD625AD — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

Choose the AD625AD when maintaining an established 16-CDIP design, purchasing an exact controlled orderable part, or preserving an existing qualified assembly is more important than introducing a new amplifier architecture. Its programmable gain from 1 to 10,000, 25 MHz gain-bandwidth product, 4 nV/√Hz noise at 1 kHz, and specified low-gain accuracy make it suitable for precision bridge, biomedical, current-measurement, laboratory, and industrial sensor interfaces. The AD625CDZ is the closest identified same-package same-family candidate for continuity, but confirm pin functions, electrical limits, temperature grade, and documentation before substitution. Because Analog Devices marks the AD625 family as not recommended for new designs, a genuinely new product should compare it with a currently recommended instrumentation amplifier rather than standardizing the legacy part without a lifecycle-risk review.

مقایسه با جایگزین‌ها

پارامتر این محصول AD625CDZ
Package 16-CDIP 16-CDIP
Brand Analog Devices Analog Devices
Product Type Programmable-gain instrumentation amplifier Programmable-gain instrumentation amplifier
Circuit Count 1 circuit 1 circuit
User-Programmed Gain Range 1 to 10,000 1 to 10,000
Gain-Bandwidth Product 25 MHz 25 MHz
Input Noise Density 4 nV/√Hz at 1 kHz 4 nV/√Hz at 1 kHz
Maximum Low-Gain Error 0.02% max 0.02% max
Maximum Low-Gain Temperature Coefficient 5 ppm/°C max 5 ppm/°C max
Maximum Low Nonlinearity 0.001% max 0.001% max
Maximum Offset Voltage 200 µV 200 µV
New-Design Recommendation Not recommended for new designs Not recommended for new designs

تفاوت‌های کلیدی

  • Wide programmable gain in a precision instrumentation amplifier (در مقابلAD625CDZ)
  • Precision low-gain accuracy (در مقابلAD625CDZ)
  • Legacy-compatible ceramic-DIP implementation (در مقابلAD625CDZ)

یادداشت‌های طراحی

Treat the external gain-setting resistor as part of the precision measurement system rather than as a generic resistor. Its tolerance and temperature coefficient contribute directly to gain accuracy, while resistance and parasitic capacitance affect the achievable closed-loop response. Use the gain relationship and resistor guidance in the Analog Devices AD625 Data Sheet Rev. D, place the resistor close to the gain-setting connection, and verify the final tolerance budget at the highest operating temperature.

Keep the differential input paths short, matched, and symmetric, and connect them to a quiet analog ground plane. High-gain measurements can pick up leakage, relay noise, switching supply ripple, and ground potential differences that are insignificant at low gain. Use a single-point analog reference where appropriate, separate noisy return currents from the sensor reference, and keep the gain-setting component away from high-current switching nodes.

Calculate usable bandwidth from the 25 MHz gain-bandwidth product at the selected programmed gain rather than assuming the full gain-bandwidth value is available at every gain. Higher gain reduces closed-loop bandwidth and may expose phase-margin or stability limitations. Confirm the intended signal spectrum, add only the filtering required by the application, and validate the complete amplifier and gain-resistor network with a bandwidth and stability test.

The 16-CDIP package can dissipate heat through its leads and board copper, but the through-hole assembly still requires adequate airflow and copper area at elevated ambient temperatures. Calculate dissipation from the actual supply voltage, output voltage, and load current, then compare the resulting junction-temperature rise with the device limits in the manufacturer datasheet. Avoid mounting the package directly above a heat source or in a sealed enclosure without thermal analysis.

اطلاعات انطباق

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

The accessible manufacturer information identifies the AD625 family as not recommended for new designs but does not establish the exact compliance status of the AD625AD orderable variant. AEC-Q100 is not applicable because this is a general-purpose instrumentation amplifier rather than an automotive-qualified device.

تاریخ تأیید داده‌ها: 2026-11-14 — داده‌ها توسط تیم مهندسی قطعات XAIPART تأیید و گردآوری شده است

جستجوهای مرتبط

ad625 datasheet AD625AD datasheet AD625AD datasheet pdf AD625AD pinout AD625AD specifications AD625AD 16-CDIP AD625AD programmable gain AD625AD strain gauge amplifier AD625AD vs AD625CDZ AD625AD drop-in replacement AD625AD equivalent Analog Devices AD625AD AD625AD price AD625AD stock

قطعات و اصطلاحات مرتبط

Analog Devices AD625AD AD625CDZ AD624 AD524 programmable-gain instrumentation amplifier instrumentation amplifier precision amplifier analog IC signal-conditioning IC low-dropout voltage regulator gain-bandwidth product 4 nV/√Hz noise density 200 µV offset voltage 0.02% low-gain error 10,000 programmed gain 16-CDIP ceramic dual inline package through-hole package strain-gage bridge biomedical instrumentation industrial sensor interface precision current measurement Analog Devices AD625 Data Sheet Rev. D
استعلام قیمت سریع RFQ
جزئیات کامل را پر کنید — تیم فروش ما ظرف 24 ساعت پاسخ خواهد داد
شماره قطعه سازنده بسته‌بندی QTY قیمت هدف قیمت کل
✓
استعلام قیمت ارسال شد!

ظرف ۲۴ ساعت به ایمیل شما پاسخ خواهیم داد

1
درخواست قیمت ارسال شد
2
استعلام دریافت شد
3
سفارش ثبت شد
4
پرداخت
5
ارسال شد
6
تحویل داده شد
مشاهده جزئیات RFQ