ICS511MT نمای کلی

The Renesas Electronics ICS511MT is a single-output PLL clock generator IC designed to produce a high-frequency CMOS clock from a lower-frequency crystal or clock input, with a maximum output frequency of 200 MHz. It is packaged in an 8-pin SOIC measuring 3.90 mm wide. The ICS511MT is identified as a LOCO PLL clock multiplier, a clock-generation approach used to multiply a reference clock while providing a stable, high-quality output for digital systems.

A PLL clock generator, also called a frequency multiplier or clock synthesizer, belongs to the clock and timing IC category. It uses a phase-locked loop to derive an output frequency from a reference source. The reference can be a crystal oscillator or external clock, and the generated CMOS output is suitable for systems requiring a higher-frequency operating clock than the source provides.

Key features of the ICS511MT include PLL clock multiplication, a maximum frequency of 200 MHz, one clock circuit, CMOS output, and support for both crystal and clock inputs. The 1:1 input-to-output ratio is listed for the device, while the PLL architecture provides a practical route to generating a high-frequency clock from a lower-frequency reference. Its single-circuit configuration suits designs requiring one multiplied clock rather than multiple independently generated outputs.

Technically, the ICS511MT is intended for clock generation where the output must be derived from a stable reference. The use of a crystal input supports designs that require predictable frequency behavior, while clock input support allows the device to operate from an existing system reference. The CMOS output interface makes it relevant to digital logic, processor, communications, and embedded-control systems requiring a high-speed clock signal.

Typical applications include clocking for digital processors, communications equipment, test and measurement systems, embedded control platforms, and general-purpose digital logic. The device can reduce the need for multiple external clock-generation solutions when a single high-frequency CMOS clock is sufficient. Its principal benefit is clock multiplication in a small 8-SOIC package, although board-level stability, jitter, supply requirements, and output-drive limits must be checked against the manufacturer datasheet before finalizing a design.

For PCB implementation, place the device close to the crystal, decoupling capacitors, and clock-consuming circuits to minimize trace length and noise pickup. Follow the manufacturer’s recommended crystal load-capacitance network, provide stable supply decoupling, and route the output as a short, controlled-impedance clock trace. Confirm pin orientation, operating limits, and crystal requirements directly from the manufacturer datasheet and the package drawing.

This product summary combines the device’s identified LOCO PLL architecture, 200 MHz maximum frequency, CMOS output, input options, package format, sourcing context, and practical clock-tree design considerations to support faster component selection and PCB planning.

جایگزین‌های drop-in برای ICS511MT — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

ICS511MIT

✅ جایگزین مستقیم
📦 8-SOIC
Same ICS511 series and 8-SOIC format; exact maximum-frequency and electrical deltas are not quantified in the available comparison data

📋 جایگزین مرجع (خارج از کاتالوگ)

ICS511MI

✅ جایگزین مستقیم
Renesas Electronics
📦 8-SOIC
Single PLL clock generator IC · 160 MHz · Single PLL · Clock or crystal input · CMOS · 1:1 · 1 · No

برای قیمت تماس بگیرید

مشاهده دیتاشیت ←

ICS511MILFT

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 8-SOIC
Same ICS511 family in an 8-SOIC package; exact operating-frequency and electrical differences are not quantified in the available data

📋 جایگزین مرجع (خارج از کاتالوگ)

ICS511MLFT

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 8-SOIC
Same ICS511 family in an 8-SOIC package; exact operating-frequency and electrical differences are not quantified in the available data

📋 جایگزین مرجع (خارج از کاتالوگ)

ICS511M

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
Renesas Electronics
📦 8-SOIC
Clock Generator IC · LOCO PLL clock multiplier · Yes · 200 MHz · 1 · Clock, Crystal · CMOS · 3.135 V to 5.25 V

برای قیمت تماس بگیرید

مشاهده دیتاشیت ←

ICS511MT مشخصات

Product Type Clock Generator IC
PLL Yes
Input Type Clock, Crystal
نوع خروجی CMOS
Maximum Frequency 200 MHz
Number of Circuits 1
Input-to-Output Ratio 1:1
Differential Input No
Differential Output No
بسته‌بندی 8-SOIC, 0.154 inch, 3.90 mm width
Architecture LOCO PLL clock multiplier
Reference Source Crystal or external clock
Output Logic CMOS
نوع نصب Surface Mount
وضعیت چرخه عمر Obsolete

راهنمای پیکربندی پین ICS511MT 8-soic, 0.154 inch, 3.90 mm width

پیکربندی پین برای ICS511MT (پکیج 8-soic, 0.154 inch, 3.90 mm width). شماره‌گذاری پایه‌ها، عملکردها و نمودارهای اتصال در دیتاشیت سازنده تعریف شده است. برای footprint دقیق و دستورالعمل‌های لحیم‌کاری به آن مراجعه کنید.

نمودار پین‌آوت پکیج 8-soic, 0.154 inch, 3.90 mm width برای ICS511MT

داده پین‌آوت تفصیلی موجود نیست برای ICS511MT.

به دیتاشیت برای پیکربندی کامل پین‌ها.

کاربردهای معمول

ICS511MT مناسب است برای 6 کاربردs: Digital Processor Clocking, Communications Equipment, Embedded Control Systems, Test and Measurement Instrumentation, Industrial Data Acquisition, General-Purpose Digital Logic.

🖥️

Digital Processor Clocking

The ICS511MT is suited to digital processor clock trees that require a CMOS clock up to 200 MHz derived from a crystal or another clock reference. Its PLL architecture provides frequency multiplication without requiring a separate high-frequency oscillator for every rail. Place the device near the crystal and processor clock input, use the manufacturer-recommended load network, and route the clock output as a short trace. The design must also verify processor setup and hold timing, clock jitter, supply range, and output loading before treating the 200 MHz rating as a complete timing guarantee.

🌐

Communications Equipment

The ICS511MT can support communications equipment that needs a stable, high-frequency CMOS clock from a lower-frequency reference. A single PLL clock generator is useful when the board already has a reference source but requires a derived clock for digital signal-processing or interface logic. Keep the reference path short, provide local supply decoupling, and maintain controlled return paths beneath the clock route. Because communications timing can be sensitive to jitter and edge quality, verify the manufacturer’s jitter, output-rise-time, and loading characteristics against the actual downstream device requirements.

🔧

Embedded Control Systems

ICS511MT is applicable to embedded-control boards that distribute a CMOS clock to one or more digital logic blocks. Its one-circuit architecture is efficient for a single-clock design, while crystal input support allows the clock generator to serve as the central element of a compact reference network. The board should separate sensitive clock routing from noisy switching nodes, use a solid ground reference, and observe the manufacturer’s crystal load-capacitance calculation. Confirm supply-voltage tolerance and maximum operating frequency for the selected controller before production release.

📡

Test and Measurement Instrumentation

The 200 MHz maximum frequency and CMOS output make ICS511MT relevant to instrumentation clock distribution where a common high-speed reference is needed for counters, converters, or digital control logic. A PLL-based arrangement can consolidate multiple frequency requirements around one reference source, but the exact multiplication ratio and operating conditions must be checked against the device specification. Use short, impedance-controlled clock traces and avoid placing the output route beside high-energy switching nodes. Probe loading and measurement grounding should also be considered during board validation.

🏭

Industrial Data Acquisition

ICS511MT can fit industrial data-acquisition systems requiring a deterministic CMOS clock for control, conversion, and communication logic. Its PLL-based reference arrangement can reduce the number of separate oscillator components while supporting either crystal or external-clock operation. Industrial equipment should account for temperature range, supply tolerance, startup behavior, and electromagnetic compatibility at the system level. Place the clock generator close to the reference source, provide the recommended bypass capacitors, and route the output away from switching power stages to minimize coupling.

💡

General-Purpose Digital Logic

For general-purpose digital logic, ICS511MT provides a single CMOS clock output with PLL-based multiplication capability and a maximum listed frequency of 200 MHz. It is most useful when a board already has a stable reference clock and needs a derived output without implementing a high-frequency oscillator network directly on the PCB. Follow the manufacturer’s power-pin and decoupling guidance, confirm input and output logic levels, and reserve the crystal footprint only when the chosen reference configuration requires it. Validate edge quality and load behavior at the intended clock frequency.

خلاصه محصولات پیشنهادی

What is the ICS511MT?
The ICS511MT is a Renesas Electronics LOCO PLL clock generator IC with one CMOS output circuit and a maximum output frequency of 200 MHz. It accepts a crystal or external clock reference and is intended to generate a high-frequency clock from a lower-frequency source. The device is identified in an 8-SOIC package measuring 0.154 inch, or 3.90 mm, in width.
What is the maximum frequency of ICS511MT?
The ICS511MT supports a maximum clock-generator frequency of 200 MHz. The manufacturer classification and distributor technical listings identify the ICS511MT as a clock generator with PLL operation, one circuit, a CMOS output, and crystal or clock inputs. The 200 MHz value is the headline operating-frequency specification; supply voltage, load conditions, and output-jitter limits should be taken from the manufacturer datasheet.
Where can I download the ICS511MT datasheet PDF?
The Renesas ICS511MT datasheet can be accessed through the Octopart datasheet page at https://octopart.com/datasheet/renesas/ICS511MT. A manufacturer-origin document is also linked through the Renesas product documentation path. Use the package drawing and pin-description table in that document when assigning the 8-SOIC footprint and checking crystal, power, and output connections.
Where can I find the ICS511MT pinout?
The ICS511MT pinout is defined in the manufacturer datasheet, available through the linked Octopart datasheet page. The component uses an 8-SOIC package, so the land pattern should be based on the standard 8-pin SOIC footprint and the manufacturer’s pin numbering. Assign individual pin names only after checking the datasheet pin-description table rather than inferring them from another ICS511 variant.
Can ICS511MT accept both crystal and external clock inputs?
Yes. The ICS511MT input specification identifies both Clock and Crystal as supported reference sources. A crystal-based design provides a discrete frequency reference, while an external-clock design lets the PLL derive its output from another system clock. The correct source configuration, load capacitance, series resistance, and input coupling arrangement must follow the manufacturer application guidance.
What is the difference between a PLL clock generator and a crystal oscillator?
A PLL clock generator derives a new output frequency from a reference clock, whereas a crystal oscillator directly establishes an output frequency using a resonant crystal and oscillator circuitry. The ICS511MT uses PLL multiplication to reach its stated maximum frequency of 200 MHz from a lower-frequency crystal or clock source. The choice affects loop stability, jitter, reference requirements, and clock-tree flexibility.
Where can I buy the ICS511MT?
Use the Request a Quote form on this page to request current availability, minimum order quantity, lead time, and a purchase quote for ICS511MT. The device is listed as obsolete in the comparison information, so lifecycle status and remaining supply should be confirmed before committing a new production design. Requesting a quote also allows the exact package suffix and delivery format to be confirmed.
What is the price of ICS511MT?
Current price and quantity-break pricing for ICS511MT should be requested through the Request a Quote form on this page. Because the component is identified as obsolete, quote terms may depend on remaining factory inventory, lot traceability, and required delivery quantity. Provide the target quantity and package suffix when requesting the quote so the supply channel can confirm the correct ICS511MT configuration.
What is the lead time for ICS511MT?
The current lead time for ICS511MT should be confirmed through the Request a Quote form on this page. The listed obsolete lifecycle status means a standard production lead time may not apply, particularly when no manufacturer stock remains. A request should include annual and prototype quantities, required delivery format, and the date by which material must be available.
Is ICS511MT in stock?
Current ICS511MT stock should be confirmed through the Request a Quote form on this page because the device is listed as obsolete. Distributor listings may contain residual inventory, but that inventory can be limited and may not be suitable for a new production ramp. Ask the supplier to confirm quantity, lot traceability, date code, package suffix, and delivery conditions in the quotation.
What can replace the ICS511MT?
The ICS511MT can be evaluated against other ICS511-family devices only after confirming identical pin assignment, reference-source support, PLL ratio options, maximum frequency, supply voltage, and output load. The search results identify ICS511MIT and ICS511MI as related ICS511 devices, while no confirmed cross-manufacturer drop-in equivalent is established. Use the Request a Quote form for the target MPN and validate any substitution against the manufacturer datasheet before redesigning the PCB.
Is ICS511MT the same as ICS511MIT?
ICS511MT and ICS511MIT belong to the same ICS511 series, but the listed delivery formats differ: ICS511MT is associated with tape-and-reel ordering while ICS511MIT is also identified as a tape-and-reel part. Their exact electrical equivalence and pin compatibility must be confirmed from the Renesas ordering information and datasheet. Do not substitute solely because the series and package descriptions appear similar.
Is ICS511MT suitable for a 200 MHz processor clock?
The ICS511MT is rated to a maximum frequency of 200 MHz and can be considered for a 200 MHz digital clock requirement when its supply, jitter, output-drive, and load specifications are acceptable. A maximum-frequency rating does not guarantee operation at every supply voltage or loading condition. Check the device’s frequency-versus-voltage and timing characteristics in the manufacturer datasheet before using it as a processor clock source.
When should I choose ICS511MT over a direct crystal oscillator?
Choose ICS511MT when a system needs a multiplied CMOS clock derived from a crystal or external reference and can tolerate the PLL implementation’s frequency-generation and jitter characteristics. A direct crystal oscillator is generally preferable when no multiplication is required and the simplest fixed-frequency clock solution is desired. The decision should consider reference flexibility, output frequency, jitter, board area, and startup behavior.
What are the key specifications of ICS511MT engineers should know?
The key ICS511MT specifications are its single clock circuit, 200 MHz maximum frequency, PLL operation, crystal or clock input, CMOS output, and 8-SOIC package with a 3.90 mm body width. It is also identified as a LOCO PLL clock multiplier and is listed as obsolete. Supply voltage, current, jitter, operating temperature, and detailed timing limits should be confirmed from the manufacturer datasheet.
What is the best Renesas alternative for ICS511MT?
ICS511MIT is the closest identified Renesas alternative because it appears in the same ICS511 series and uses an 8-SOIC-related configuration, but it should not be treated as an automatic replacement without checking its exact ordering code and electrical specification. No verified cross-brand drop-in equivalent was identified for ICS511MT. For an engineering change, compare the pinout, maximum frequency, PLL ratios, input range, supply range, and lifecycle requirements before approval.

داده‌های مرجع مهندسی برای ICS511MT — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

Choose the ICS511MT when the design needs a single CMOS clock output, accepts either a crystal or external clock reference, and may operate up to 200 MHz. ICS511MIT is the closest same-series option identified by the available comparison data, but its exact ordering code and electrical limits should be confirmed before substitution. Avoid ICS511MI when the system requires more than 160 MHz, since its stated maximum is 20% below the ICS511MT rating. The other listed ICS511-family candidates should be treated as design-review options rather than automatic replacements until their pinout, supply range, PLL ratios, and frequency limits match the ICS511MT. Because the device is listed as obsolete, choose it primarily for maintenance of an existing design, an approved equivalent, or a controlled build using previously qualified material rather than as the default for a new platform.

مقایسه با جایگزین‌ها

پارامتر این محصول ICS511MIT ICS511MI ICS511MILFT ICS511MLFT ICS511M
Package 8-SOIC, 3.90 mm width 8-SOIC 8-SOIC 8-SOIC 8-SOIC 8-SOIC
Brand Renesas Electronics Renesas Electronics Renesas Electronics Renesas Electronics Renesas Electronics Renesas Electronics
Device Type Clock Generator IC Clock Generator IC Clock Generator IC Clock Generator IC Clock Generator IC Clock Generator IC

تفاوت‌های کلیدی

  • Higher stated maximum clock frequency than ICS511MI (در مقابلICS511MI)
  • Broad reference-source support (در مقابلICS511MIT)
  • Single-output CMOS clock architecture (در مقابلICS511MI)

یادداشت‌های طراحی

Place the ICS511MT near the crystal and clock-consuming circuitry, and keep the clock output trace short. Use a continuous ground reference beneath the clock path, avoid routing parallel to noisy power-converter nodes, and use the manufacturer’s recommended crystal load network. Confirm the 8-SOIC pin orientation and land pattern against the package drawing before fabrication.

Treat the CMOS clock output as a high-speed signal: use a short route, minimize stubs, provide a nearby return path, and maintain consistent geometry where the clock crosses a board boundary. Validate rise time, overshoot, ringing, and downstream load in simulation or with an oscilloscope. The 200 MHz maximum-frequency rating alone does not establish timing margin for a particular receiver.

Do not select an ICS511-family substitute from the series name alone. Confirm the exact MPN, pin assignment, input-source configuration, maximum frequency, supply range, and delivery suffix against the manufacturer datasheet. In particular, ICS511MI is listed at 160 MHz versus 200 MHz for ICS511MT, making it unsuitable for designs that require the full target frequency.

Follow the manufacturer’s power-pin connection and decoupling layout for the ICS511MT. Place the required bypass capacitor immediately adjacent to the device supply pin and provide an unobstructed ground return. Check the device’s current consumption and supply operating limits in the datasheet; those values were not present in the available product summaries and must not be assumed for a new design.

اطلاعات انطباق

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

Compliance status was not stated in the available product listings. Check the manufacturer datasheet and current material-compliance documentation before new production approval.

تاریخ تأیید داده‌ها: 2026-11-05 — داده‌ها توسط تیم مهندسی قطعات XAIPART تأیید و گردآوری شده است

جستجوهای مرتبط

ICS511MT datasheet ICS511MT pinout ICS511MT datasheet pdf ICS511MT 200MHz clock generator ICS511MT 8-SOIC footprint ICS511MT equivalent ICS511MT drop-in replacement ICS511MT cross reference ICS511MT vs ICS511MI Renesas ICS511MT ICS511MT price ICS511MT stock ICS511MT obsolete replacement ICS511MT CMOS clock output ICS511MT crystal clock input

قطعات و اصطلاحات مرتبط

Renesas Electronics ICS511MT ICS511MIT ICS511MI ICS511MILFT ICS511MLFT ICS511M Clock Generator IC PLL clock multiplier LOCO PLL Frequency multiplier Clock synthesizer Phase-locked loop CMOS output Crystal oscillator Clock and timing IC 8-SOIC SOIC family Surface mount SMD Digital clock Clock tree 200 MHz RoHS REACH
استعلام قیمت سریع RFQ
جزئیات کامل را پر کنید — تیم فروش ما ظرف 24 ساعت پاسخ خواهد داد
شماره قطعه سازنده بسته‌بندی QTY قیمت هدف قیمت کل
✓
استعلام قیمت ارسال شد!

ظرف ۲۴ ساعت به ایمیل شما پاسخ خواهیم داد

1
درخواست قیمت ارسال شد
2
استعلام دریافت شد
3
سفارش ثبت شد
4
پرداخت
5
ارسال شد
6
تحویل داده شد
مشاهده جزئیات RFQ