Renesas Electronics

ICS512MIT - 160MHz PLL Clock Generator | Renesas Electronics

MPN: ICS512MIT ✗ پایان تولید
3 V to 5 V Vdss 8-SOIC, 0.154 inch / 3.90mm width Package 160 MHz Speed
حداقل سفارش: 1 |

ICS512MIT نمای کلی

Renesas Electronics ICS512MIT is a 160MHz PLL clock generator IC with one CMOS output, clock or crystal input, and an 8-SOIC package measuring 0.154 inch or 3.90mm in width. The device is designed to generate a high-quality high-frequency clock output and a reference clock from a lower-frequency crystal or clock input using phase-locked-loop techniques.

A PLL clock generator is a timing IC that multiplies or synthesizes a clock frequency while providing a stable reference for digital and analog systems. The ICS512 belongs to the clock and timing hierarchy within integrated circuits, where it functions as a frequency multiplier and clock source. Its low-cost oscillator architecture is intended to replace conventional crystal oscillators in many electronic systems.

Key features include a maximum operating frequency of 160MHz, one clock or crystal input, one CMOS output, and PLL operation with bypass capability. The input-to-output ratio listed for the device is 1:2, allowing a lower-frequency reference to generate a higher-frequency clock. The operating supply range is 3V to 5V, and the specified operating temperature range is -40°C to +85°C.

The PLL-based architecture uses a standard fundamental-mode crystal to establish a stable reference, then multiplies that reference to generate the requested output clock. Bypass mode provides a practical path for clock distribution or test configurations. The CMOS output is suited to digital logic, communication equipment, consumer electronics, and embedded systems requiring a centralized clock source.

Typical applications include digital controller boards, communication modules, industrial control equipment, test and measurement systems, and embedded products that require a multiplied clock or reference signal. The 8-SOIC surface-mount package supports compact board layouts while keeping assembly compatible with conventional SOIC-8 footprint practices.

Designers should confirm the crystal frequency, PLL ratio, output waveform, load capacitance, and bypass configuration against the manufacturer application guidance. Decoupling capacitors should be placed close to the supply and ground pins, and clock traces should be routed with controlled impedance and minimized loading.

This product page combines the manufacturer specifications, package information, lifecycle status, practical design notes, and sourcing guidance for engineers evaluating the ICS512MIT as an obsolete clock-generation component or replacement candidate.

جایگزین‌های drop-in برای ICS512MIT — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

هیچ جایگزین مستقیمی برای این محصول موجود نیست.

درخواست جایگزین

ICS512MIT مشخصات

Product Type PLL clock generator
Maximum Frequency 160 MHz
Number of Circuits 1
نوع خروجی CMOS
Input Type Clock or crystal
PLL Yes, with bypass
Input-to-Output Ratio 1:2
Supply Voltage Range 3 V to 5 V
محدوده دمای کاری -40°C to +85°C
بسته‌بندی 8-SOIC, 0.154 inch / 3.90mm width
نوع نصب Surface mount
دسته‌بندی Clock generators, PLLs, frequency synthesizers
Output Frequency 160 MHz maximum
تعداد خروجی‌ها 1
Manufacturer Renesas Electronics Corporation
Original Manufacturer Integrated Device Technology / Integrated Circuit Systems
وضعیت چرخه عمر Obsolete (EOL)

راهنمای پیکربندی پین ICS512MIT 8-soic, 0.154 inch / 3.90mm width

پیکربندی پین برای ICS512MIT (پکیج 8-soic, 0.154 inch / 3.90mm width). شماره‌گذاری پایه‌ها، عملکردها و نمودارهای اتصال در دیتاشیت سازنده تعریف شده است. برای footprint دقیق و دستورالعمل‌های لحیم‌کاری به آن مراجعه کنید.

نمودار پین‌آوت پکیج 8-soic, 0.154 inch / 3.90mm width برای ICS512MIT

داده پین‌آوت تفصیلی موجود نیست برای ICS512MIT.

به دیتاشیت برای پیکربندی کامل پین‌ها.

کاربردهای معمول

ICS512MIT مناسب است برای 6 کاربردs: Digital Controller Clocking, Communication Module Clock Reference, Industrial Control Equipment, Test and Measurement Systems, Embedded Consumer Products, Clock Distribution and Test Modes.

🔧

Digital Controller Clocking

The ICS512MIT fits legacy digital controller designs that need a multiplied clock generated from a lower-frequency crystal or reference. Its PLL multiplier provides a maximum output frequency of 160 MHz, while the 1:2 input-to-output ratio allows a lower-frequency reference to be raised to the required operating rate. The single CMOS output is appropriate for a central controller, processor, or programmable logic device in older 3.3 V or 5 V equipment. Designers should verify the required crystal frequency and ensure that the PLL configuration produces the exact clock expected by the downstream digital circuit.

🌐

Communication Module Clock Reference

ICS512MIT can serve as the clock-generation element in a legacy communication module requiring a stable, high-frequency reference from a crystal source. The PLL-based architecture is intended to generate a high-quality output clock and reference clock, while the CMOS output can feed a controller, transceiver, or digital signal-processing chain. Its 160 MHz ceiling supports timing requirements commonly found in older embedded communication equipment. PCB layout should keep the crystal path short and isolate the clock output from noisy switching nodes.

🏭

Industrial Control Equipment

The ICS512MIT is applicable to industrial control equipment designed around older clock architectures, with its specified -40°C to +85°C operating range covering many industrial environments. A single CMOS clock output can synchronize control logic, data acquisition electronics, or communications hardware. The 8-SOIC package is straightforward to accommodate in conventional surface-mount assemblies. Because the device is obsolete, engineers should confirm availability and evaluate an active replacement before committing to a new production design.

⚡

Test and Measurement Systems

ICS512MIT can provide a multiplied clock or reference signal in legacy test and measurement systems that use a crystal-based timing architecture. Its PLL capability supports clock generation up to 160 MHz, and the 1:2 ratio can simplify designs using a fundamental reference frequency. The CMOS output is compatible with common digital timing and control blocks. Measurement accuracy still depends on the reference source, loop filtering, layout quality, and downstream clock requirements, so engineers should validate jitter and edge performance in the complete circuit.

📱

Embedded Consumer Products

ICS512MIT is appropriate for maintaining older embedded consumer products that already use an 8-SOIC PLL clock generator. Its 3 V to 5 V operating range supports common embedded supply rails, and its single CMOS output can feed a controller or peripheral requiring a multiplied clock. The device provides a familiar architecture for servicing and reproducing older equipment, but new product development should favor an active clock generator with confirmed availability, lifecycle support, and equivalent timing performance. Do not assume that an 8-SOIC replacement is pin-compatible without checking the manufacturer’s pin table.

🖥️

Clock Distribution and Test Modes

The ICS512MIT’s PLL bypass capability makes it useful in legacy systems that need to switch between an internally multiplied clock and an external or reference clock path. The bypass function can support board test, clock-source selection, or diagnostic configurations where a direct reference is useful. Its one-output architecture limits scalability compared with multi-output clock buffers, so larger designs may need an additional distribution stage. Layout should keep the bypass source, crystal path, and output trace controlled to prevent timing degradation.

What is the operating frequency of ICS512MIT?
The ICS512MIT supports operation up to 160 MHz. The Renesas 512 datasheet identifies the ICS512 as a PLL clock multiplier with a maximum frequency of 160 MHz, allowing a lower-frequency crystal or clock input to produce a higher-frequency CMOS output. The device is listed as a one-circuit clock generator in an 8-SOIC package.
What type of IC is ICS512MIT?
The ICS512MIT is a PLL clock generator IC with one CMOS output. It accepts a clock or crystal input, supports PLL operation with bypass, and is intended to generate a high-quality clock output and reference clock from a lower-frequency source. The Renesas 512 datasheet describes the LOCO family as a low-cost approach to replacing crystal oscillators in many electronic systems.
What is the input-to-output ratio of ICS512MIT?
The specified input-to-output ratio for ICS512MIT is 1:2. This means the PLL can generate an output clock at twice the reference frequency under the stated operating conditions. The manufacturer application guidance should be used to confirm the required crystal frequency, PLL configuration, output frequency, and bypass behavior for the target design.
What supply voltage does ICS512MIT operate from?
ICS512MIT operates from a 3 V to 5 V supply, as specified in the product data for the Renesas ICS512 family. The clock generator is therefore suitable for both 3.3 V and 5 V digital systems. Supply decoupling and layout should follow the manufacturer’s recommended application circuit to limit clock jitter and supply-noise coupling.
What package does ICS512MIT use?
ICS512MIT is supplied in an 8-SOIC surface-mount package. The distributor specification identifies the body width as 0.154 inch, or 3.90 mm. Because this is an obsolete component, a replacement should be checked carefully for the same 8-SOIC footprint, pin assignment, supply range, clock input arrangement, and output behavior.
Is ICS512MIT still active?
ICS512MIT is listed as obsolete or end-of-life in product-index data for the original Integrated Device Technology device. The Renesas 512 datasheet remains available as a technical reference, and distributor listings may still show the MPN for legacy inventory. For new production, confirm availability and any approved replacement with the manufacturer or through the Request a Quote form on this page.
Where can I download the ICS512MIT datasheet PDF?
The official Renesas 512 datasheet is available at https://www.renesas.com/en/document/dst/512-datasheet. It is the preferred document for the clock multiplier architecture, PLL bypass behavior, recommended application information, and electrical characteristics. Use the manufacturer’s pin-description table when assigning PCB tracks or checking the 8-SOIC connection arrangement.
Where can I find the ICS512MIT pinout?
The ICS512MIT pinout is found in the pin-description section of the Renesas 512 datasheet. Use that table to verify supply pins, ground, clock or crystal input, PLL control, and CMOS output assignments before routing the board. The 8-SOIC package is represented by the soic-8 package designation, but the manufacturer pin table remains the authoritative source for exact pin numbers and functions.
What can replace ICS512MIT?
A suitable replacement for ICS512MIT must be a true 8-SOIC drop-in candidate with the same clock-input arrangement, PLL bypass behavior, CMOS output, 3 V to 5 V supply compatibility, and approximately 160 MHz maximum operating frequency. Cross-reference search results identify generic lookup tools, but they do not provide a verified candidate MPN for this exact device. Use those tools or the Request a Quote form on this page to identify a currently confirmed equivalent.
What is the best equivalent for ICS512MIT?
The best equivalent is the device that preserves the complete ICS512MIT interface and timing behavior: an 8-SOIC footprint, 1:2 PLL ratio, clock or crystal input, CMOS output, bypass mode, 3 V to 5 V operation, and up to 160 MHz output. No verified cross-brand MPN is identified in the available results, so do not approve a substitute from package similarity alone; validate the pinout and electrical limits first.
Can a 160 MHz clock generator replace ICS512MIT?
A 160 MHz clock generator is only a candidate replacement if it also matches the ICS512MIT’s 8-SOIC pinout, PLL ratio, reference-input method, output type, supply range, bypass function, and timing characteristics. Frequency alone is insufficient for a drop-in decision. Check the Renesas 512 datasheet and the candidate manufacturer’s application and pinout documentation before redesigning the PCB.
ICS512MIT versus an equivalent PLL clock generator: which is better?
The ICS512MIT is preferable when the existing board already uses its documented 8-SOIC footprint and requires its 1:2 PLL multiplication and bypass arrangement. A newer generator may be better when it provides confirmed availability, lower jitter, wider supply tolerance, or a smaller package. The deciding factors are pin compatibility, maximum frequency, output waveform, supply range, jitter, and lifecycle status.
When should I choose ICS512MIT for a new design?
Choose ICS512MIT for a new design only when maintaining an existing legacy PCB is more important than obtaining a currently active component. Its 160 MHz maximum frequency, 3 V to 5 V supply range, one CMOS output, and clock or crystal input fit older clock-generation architectures, but its obsolete status creates sourcing and long-term continuity risk. Use an active, verified replacement for new production whenever one is qualified.
Is ICS512MIT suitable for industrial equipment?
ICS512MIT is rated for an operating temperature range of -40°C to +85°C and is technically suitable for many industrial temperature environments. Compliance details such as RoHS, REACH, AEC-Q100, and lead-free status are not established in the available product information. Confirm the specific qualification and regulatory requirements before using the obsolete device in new industrial or safety-related equipment.
How should ICS512MIT be placed on a PCB?
Place the ICS512MIT close to the crystal or reference-clock source and the intended clock load, and connect the bypass and feedback components according to the manufacturer application circuit. Keep supply decoupling close to the IC, provide a short ground return, and route the high-frequency clock trace with controlled impedance. Confirm the exact capacitor values and pin connections from the Renesas 512 datasheet.

داده‌های مرجع مهندسی برای ICS512MIT — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

Choose ICS512MIT when maintaining or reproducing an existing design that already uses its 8-SOIC footprint, 1:2 PLL ratio, crystal or clock input, CMOS output, and bypass behavior. Its maximum frequency of 160 MHz and 3 V to 5 V supply range make it useful for older digital controllers, communication modules, and test equipment. For new production, favor an active alternative because ICS512MIT is obsolete and long-term supply continuity is uncertain. A replacement should be accepted only after confirming the package, exact pinout, PLL ratio, reference-input method, output type, bypass logic, supply range, timing performance, and operating-temperature grade. A frequency match alone is insufficient because incompatible clock-control pins or different crystal-loading requirements can prevent operation.

مقایسه با جایگزین‌ها

پارامتر این محصول
Brand Renesas Electronics
Package 8-SOIC
Maximum Frequency 160 MHz
Number of Circuits 1
Output Type CMOS
Input Type Clock or crystal
PLL Yes, with bypass
Input-to-Output Ratio 1:2
Supply Voltage Range 3 V to 5 V
Operating Temperature -40°C to +85°C

تفاوت‌های کلیدی

  • Single CMOS clock output with PLL bypass support (در مقابلICS512MIT)
  • Legacy-compatible 8-SOIC footprint (در مقابلICS512MIT)
  • Broad 3 V to 5 V operating range (در مقابلICS512MIT)

یادداشت‌های طراحی

Keep the crystal, reference-clock input, PLL support components, and ICS512MIT on the same side of the PCB where practical. Place the decoupling capacitor at the device supply and ground pins rather than at the connector or power-source entry point. This minimizes loop area and helps prevent supply noise from coupling into the clock output.

Route the clock output as a short, controlled-impedance trace and avoid sharing it with long switching nets. Keep the crystal path away from high-current switches, inductors, and fast digital edges. When bypassing the PLL, route the selected clock source cleanly and confirm that the bypass configuration in the Renesas 512 datasheet matches the system test mode.

Do not select a replacement based only on the 8-SOIC package or the 160 MHz headline frequency. Verify pin numbers, crystal connection, PLL ratio, bypass behavior, supply limits, output waveform, and operating-temperature requirements against the manufacturer datasheet. ICS512MIT is obsolete, so any substitute must also be checked for current lifecycle status and production continuity.

اطلاعات انطباق

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

The available product information does not establish the compliance status of ICS512MIT.

تاریخ تأیید داده‌ها: 2026-11-16 — داده‌ها توسط تیم مهندسی قطعات XAIPART تأیید و گردآوری شده است

جستجوهای مرتبط

ICS512MIT datasheet ICS512MIT pinout ICS512MIT equivalent ICS512MIT replacement ICS512MIT cross reference ICS512MIT price ICS512MIT stock Renesas ICS512MIT ICS512MIT 160MHz clock generator ICS512MIT 8-SOIC pinout ICS512MIT PLL bypass ICS512MIT application circuit

قطعات و اصطلاحات مرتبط

Renesas Electronics ICS512MIT Integrated Device Technology Integrated Circuit Systems PLL clock generator clock generator frequency multiplier frequency synthesizer clock and timing IC CMOS output crystal input PLL bypass 8-SOIC SOIC package family surface mount technology 160 MHz 3 V to 5 V 1:2 multiplication ratio digital controller communication module industrial control equipment test and measurement embedded systems legacy clock architecture obsolete integrated circuit
استعلام قیمت سریع RFQ
جزئیات کامل را پر کنید — تیم فروش ما ظرف 24 ساعت پاسخ خواهد داد
شماره قطعه سازنده بسته‌بندی QTY قیمت هدف قیمت کل
✓
استعلام قیمت ارسال شد!

ظرف ۲۴ ساعت به ایمیل شما پاسخ خواهیم داد

1
درخواست قیمت ارسال شد
2
استعلام دریافت شد
3
سفارش ثبت شد
4
پرداخت
5
ارسال شد
6
تحویل داده شد
مشاهده جزئیات RFQ