Texas Instruments

INA111BP - 2MHz FET-Input Instrumentation Amp | Texas Instruments

MPN: INA111BP ✓ فعال
500 uV maximum Vdss 20 pA maximum Id 8-pin PDIP Package
حداقل سفارش: 1 |

INA111BP نمای کلی

Texas Instruments INA111BP is a high-speed, FET-input instrumentation amplifier with 2 MHz bandwidth at a gain of 10, 17 V/us slew rate, and low input bias current of 20 pA maximum, housed in an 8-pin PDIP package. The single-circuit device supports externally selected gains from 1 to more than 1000 through one resistor and uses a current-feedback topology to maintain speed at higher closed-loop gains.

An instrumentation amplifier is a specialized analog signal-conditioning IC designed to amplify small differential sensor signals while rejecting common-mode voltage. The INA111 belongs to the instrumentation-amplifier hierarchy, which combines differential input, high input impedance, precise gain setting, and common-mode rejection. Its FET inputs suit high-impedance transducers, while laser-trimmed offset characteristics support accurate measurement of low-level signals.

Key features include a 20 pA maximum input bias current, 500 uV maximum offset voltage, 5 uV/°C maximum offset drift, and 106 dB minimum common-mode rejection. The INA111 settles to 0.01% in 4 us at a gain of 100. These characteristics make the device useful where fast acquisition and high source impedance must coexist with accurate differential amplification.

The current-feedback architecture differentiates the INA111 from conventional voltage-feedback instrumentation amplifiers. It provides extended bandwidth of 2 MHz at a gain of 10 and a 17 V/us high slew rate, improving response to rapidly changing inputs. Gain is set by one external resistor, while the internal resistor network supports gain selections that do not require that external component.

Typical applications include bridge-sensor signal conditioning, industrial process measurement, biomedical instrumentation, current-shunt monitoring, and precision data-acquisition systems. The low input bias current is particularly useful with high-impedance sources, while the 2 MHz bandwidth benefits sampled or multiplexed measurement systems requiring short acquisition times.

When designing around the INA111BP, verify the input and output voltage limits, supply headroom, and common-mode range for the intended signal. Place the gain-setting resistor close to the appropriate RG pins, maintain symmetric input routing, and use adequate bypassing at the supply pins to preserve bandwidth and minimize added noise.

This page combines verified manufacturer specifications, distributor pricing, same-package replacement guidance, comparison parameters, and practical design notes. It is intended to help engineers evaluate the INA111BP beyond a basic distributor listing while highlighting the checks required before substituting any pin-compatible device.

جایگزین‌های drop-in برای INA111BP — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

INA110BP

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 PDIP-8
Gain range differs by approximately 900% at the upper limit: up to 10,000 versus greater than 1,000; bandwidth must be verified for the selected gain

📋 جایگزین مرجع (خارج از کاتالوگ)

INA114BP

✅ جایگزین مستقیم
Texas Instruments
📦 PDIP-8
Precision instrumentation amplifier · 1 circuit · Three-op-amp instrumentation amplifier · 1 to 10,000 · 1 MHz · 11 nV/sqrt(Hz) · 50 uV maximum · 0.25 uV/degree C maximum

برای قیمت تماس بگیرید

مشاهده دیتاشیت ←

INA128BP

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 PDIP-8
Gain ceiling is 10,000 versus greater than 1,000, a 900% increase; lower high-gain bandwidth than the verified 2 MHz INA111BP benchmark

📋 جایگزین مرجع (خارج از کاتالوگ)

INA129BP

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 PDIP-8
Gain ceiling is 10,000 versus greater than 1,000, a 900% increase; high-gain bandwidth is lower than the verified 2 MHz INA111BP benchmark

📋 جایگزین مرجع (خارج از کاتالوگ)

INA130BP

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 PDIP-8
Gain ceiling is 10,000 versus greater than 1,000, a 900% increase; high-gain bandwidth is lower than the verified 2 MHz INA111BP benchmark

📋 جایگزین مرجع (خارج از کاتالوگ)

INA111BP حداکثر مقادیر مجاز و مشخصات الکتریکی

Number of Circuits 1 circuit
Device Type High-speed FET-input instrumentation amplifier
بسته‌بندی 8-pin PDIP
نوع نصب Through-hole
Input Bias Current 20 pA maximum
Offset Voltage 500 uV maximum
Offset Voltage Drift 5 uV/°C maximum
Common-Mode Rejection Ratio 106 dB minimum
Bandwidth 2 MHz at gain 10
Settling Time 4 us to 0.01% at gain 100
Slew Rate 17 V/us
Gain Range 1 to greater than 1000
Gain Setting One external resistor
Signal Topology Current-feedback
Input Stage FET input
وضعیت RoHS unknown
REACH Status unknown

پیکربندی پین INA111BP

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
پین 1 RG — Gain-setting resistor terminal
پین 2 IN- — Inverting differential input
پین 3 IN+ — Non-inverting differential input
پین 4 V- — Negative supply connection
پین 5 RG — Gain-setting resistor terminal
پین 6 OUT — Instrumentation-amplifier output
پین 7 VS — Positive supply connection
پین 8 RG — Gain-setting resistor terminal

کاربردهای معمول

INA111BP مناسب است برای 6 کاربردs: High-Impedance Sensor Signal Conditioning, Bridge and Strain-Gauge Measurement, Precision Current-Shunt Monitoring, Fast Data-Acquisition Front End, Medical and Bioelectric Instrumentation, Industrial Process and Control Monitoring.

🏭

High-Impedance Sensor Signal Conditioning

The INA111BP fits high-impedance differential sensor measurement because its FET input bias current is limited to 20 pA maximum, reducing loading of the source. Its verified 106 dB minimum common-mode rejection helps preserve the small differential signal when sensor and ground-referenced measurement circuitry share a noisy environment. The 500 uV maximum offset voltage and 5 uV/°C maximum drift are also relevant when the output must remain accurate over temperature. Place the device close to the sensor or buffer stage, balance the input traces, and verify the actual common-mode and output ranges for the selected gain. The 2 MHz bandwidth at gain 10 provides ample response for many slowly varying sensors while retaining short settling time for multiplexed acquisition.

🏭

Bridge and Strain-Gauge Measurement

The INA111BP is appropriate for bridge or strain-gauge front ends requiring differential amplification and common-mode rejection. The verified 106 dB minimum common-mode rejection suppresses common-mode excitation and supply-related variation, while the 20 pA maximum input bias current avoids substantially loading a resistive bridge. Its gain may be set with one external resistor, simplifying analog scaling for an ADC or controller. The 2 MHz bandwidth at gain 10 and 4 us settling to 0.01% at gain 100 support fast acquisition. Engineering validation should include bridge excitation drift, lead resistance, input protection, resistor tolerance, and the allowed common-mode voltage. Keep the differential pair geometrically matched so that connector and copper parasitics do not degrade CMRR.

⚡

Precision Current-Shunt Monitoring

The INA111BP can amplify the small differential voltage generated by a current shunt while rejecting the supply or bus voltage common to both shunt terminals. Its verified 500 uV maximum offset voltage is important when working with millivolt-level shunt signals, and the 20 pA maximum input bias current limits error from very high-impedance sensing arrangements. The single-resistor gain control supports convenient scaling from 1 to greater than 1000. Because common-mode rejection is specified at 106 dB minimum, board layout and source resistance remain critical to achieved system accuracy. Route the Kelvin sense pair together, avoid sharing return current with sensitive signal paths, and confirm that shunt transients remain within the device's verified common-mode and supply limits.

🖥️

Fast Data-Acquisition Front End

The INA111BP is useful in a fast data-acquisition front end where a sensor or converter produces a small differential signal that must be scaled before digitization. Its current-feedback architecture provides verified 2 MHz bandwidth at gain 10 and a 17 V/us slew rate, while the 4 us settling time to 0.01% at gain 100 supports rapid conversion cycles. These values allow less settling time to be allocated between multiplexed channels. Place the gain resistor close to its RG terminals and provide local supply bypassing to preserve the advertised high-speed behavior. Check the output swing at the selected gain and ensure the downstream ADC input range is not saturated. A carefully selected gain reduces quantization noise, while excessive gain can move the signal outside the amplifier's output range before the converter samples it.

💊

Medical and Bioelectric Instrumentation

The INA111BP can serve in biomedical instrumentation when the design requires a low-bias differential input stage and fast signal recovery. The 20 pA maximum input bias current reduces the load presented to high-impedance bioelectric electrodes or sensing networks, while the 106 dB minimum common-mode rejection helps reject offsets shared by the measurement electrodes. Its 2 MHz bandwidth at gain 10 is suitable for fast physiological waveforms, while the 17 V/us slew rate helps preserve large transient response. Clinical suitability nevertheless depends on the complete system design, not the amplifier alone. Designers must verify leakage, isolation, protection, input capacitance, patient-safety requirements, and applicable regulatory standards. Short guarded inputs and careful grounding are especially important when resolving microvolt-level signals.

🔧

Industrial Process and Control Monitoring

The INA111BP suits industrial process monitoring when a transducer produces a low-level differential signal in the presence of substantial common-mode voltage. Its verified common-mode rejection of at least 106 dB and 500 uV maximum offset voltage support accurate signal recovery, while the FET input's 20 pA maximum bias current is compatible with high-impedance sensors. The 2 MHz bandwidth at gain 10 gives sufficient margin for many process signals while supporting faster diagnostics. In deployed equipment, add appropriate surge and transient protection ahead of the amplifier, maintain the specified supply and common-mode limits, and isolate sensitive grounds from motor and relay returns. The single external gain resistor makes calibration straightforward, but its tolerance and temperature coefficient should be included in the end-to-end measurement uncertainty.

What are the key specifications of INA111BP that engineers should know?
The INA111BP is a single-circuit, high-speed FET-input instrumentation amplifier with 2 MHz bandwidth at gain 10, a 17 V/us slew rate, and a 20 pA maximum input bias current. According to the Texas Instruments INA111 manufacturer datasheet, it supports externally selected gains from 1 to greater than 1000 and settles to 0.01% in 4 us at gain 100. The device is supplied in an 8-pin PDIP package.
Where can I download the INA111BP datasheet PDF?
The official INA111BP datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina111.pdf. The document covers the INA111 high-speed FET-input instrumentation amplifier, including its 2 MHz bandwidth at gain 10, 17 V/us slew rate, external gain-setting arrangements, and application information. The manufacturer product page is https://www.ti.com/product/INA111.
Where can I find the INA111BP pinout?
The INA111BP pinout is identified in the Texas Instruments INA111 manufacturer datasheet, available at https://www.ti.com/lit/ds/symlink/ina111.pdf. The device uses an 8-pin PDIP package. Its connections include the differential inputs, supply rails, output, and gain-setting resistor terminals; verify the numbered diagram and gain-table connections against the datasheet before PCB fabrication.
What is the input bias current of INA111BP?
The INA111BP has a maximum input bias current of 20 pA. According to the Texas Instruments INA111 manufacturer datasheet, the low-bias FET input stage is suitable for high-impedance signal sources because it minimizes the current drawn from the source. This specification is particularly important when measuring sensors whose output impedance and thermal noise would otherwise degrade measurement accuracy.
What bandwidth and settling time does the INA111BP provide?
The INA111BP provides 2 MHz bandwidth at a gain of 10 and settles to 0.01% in 4 us at a gain of 100. According to the Texas Instruments INA111 manufacturer datasheet, its current-feedback architecture supports extended bandwidth and fast settling. These figures make it suitable for fast data acquisition, multiplexing, and sensor systems requiring accurate response to rapidly changing differential inputs.
How is the gain set on an INA111BP?
A single external resistor sets the INA111BP gain for operating modes that require user adjustment, with supported gains extending above 1000. According to the Texas Instruments INA111 manufacturer datasheet, the internal resistor arrangement also permits specified gain selections without the external component. Use the manufacturer gain equations and connection table because resistance tolerance, temperature coefficient, and parasitic capacitance affect practical gain accuracy.
Where can I buy INA111BP online?
The INA111BP can be purchased from Texas Instruments-authorized distributors, with DigiKey listing it as an 8-PDIP instrumentation amplifier and Mouser also offering the device. LCSC lists the INA111BP in stock at a unit price of $31.1845 as of October 29, 2026. Availability and price can change, so confirm the exact suffix, stock status, and authorized-channel status before placing an order.
What is the price of INA111BP?
The verified INA111BP reference price is $31.1845 per unit as of October 29, 2026, based on the LCSC product listing. DigiKey and Mouser also provide INA111BP catalog pages with pricing and availability information. The only explicitly provided numeric price is the LCSC unit price, so quantity-break pricing should be confirmed before budgeting a larger production order.
Is INA111BP in stock and what is its lead time?
The INA111BP is shown in stock by LCSC in the verified product data, and DigiKey states that the part ships today, although no numeric manufacturer lead time is supplied. Stock quantity and lead time can vary by distributor and order quantity. As of October 29, 2026, request a firm quotation for scheduled production volumes and confirm whether the manufacturer or an authorized distributor can support the required schedule.
INA111BP versus INA114BP: which is better for a fast measurement system?
Choose the INA111BP for a fast measurement system when bandwidth and settling time are priorities. According to the Texas Instruments product and manufacturer datasheet information, the INA111BP reaches 2 MHz bandwidth at gain 10 and settles to 0.01% in 4 us at gain 100. The INA114BP offers precision-oriented instrumentation-amplifier functionality and a much higher gain ceiling, but the verified sources do not establish an equivalent 2 MHz bandwidth at gain 10.
What is the difference between INA111BP and INA110BP?
The INA111BP emphasizes higher-speed operation, with 2 MHz bandwidth at gain 10 and a 17 V/us slew rate, while the INA110BP is a closely related precision instrumentation amplifier. According to the Texas Instruments INA111 manufacturer datasheet, the INA111 uses a current-feedback topology for extended bandwidth. For a replacement, confirm common-mode range, output swing, supply limits, gain-table wiring, and stability because those parameters are not fully provided in the verified source data.
When should I choose INA111BP over INA114BP?
Choose the INA111BP when the signal changes quickly and the acquisition path needs high bandwidth or short settling time. Its verified characteristics include 2 MHz bandwidth at gain 10, 17 V/us slew rate, and 4 us settling to 0.01% at gain 100. Choose INA114BP instead when its precision-oriented feature set and gain range better match a higher-gain measurement, provided its bandwidth and settling requirements have been independently verified.
Is INA111BP suitable for high-impedance sensor measurement?
Yes, the INA111BP is suitable for high-impedance sensor measurement because its FET inputs have a maximum input bias current of 20 pA. According to the Texas Instruments INA111 manufacturer datasheet, this low input current reduces loading of sensitive sources. The 106 dB minimum common-mode rejection and 500 uV maximum offset voltage also support accurate differential signal conditioning, although actual accuracy remains dependent on source impedance and circuit layout.
What can replace INA111BP without redesigning the PCB?
The INA114BP is the closest cross-reference identified in the verified web data because it also appears in an 8-pin PDIP instrumentation-amplifier configuration. However, a true drop-in decision requires comparing bandwidth, gain equation, common-mode range, output swing, supply limits, and pin functions. The INA110BP and related TI PDIP options may also be candidates, but the provided sources do not contain enough verified electrical data to claim exact equivalence.
What is the best Analog Devices equivalent for INA111BP?
The verified cross-reference results state that an Analog Devices replacement exists, but they do not provide the specific Analog Devices MPN or its package and pinout. An Analog Devices equivalent therefore cannot be identified reliably as a drop-in alternative from the supplied data. Before substituting any part, compare the 8-pin PDIP footprint, differential-input polarity, RG connection method, gain equation, bandwidth, input bias current, common-mode range, and supply requirements.

داده‌های مرجع مهندسی برای INA111BP — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

Choose the INA111BP when the design needs a high-speed differential measurement stage, particularly for high-impedance sources, rapidly changing signals, or multiplexed data acquisition. Its verified 2 MHz bandwidth at gain 10, 17 V/us slew rate, 4 us settling to 0.01% at gain 100, and 20 pA maximum input bias current provide a clear performance baseline. Choose INA110BP or INA114BP when their precision-oriented characteristics and gain range extending to 10,000 are more useful, but verify their bandwidth at the operating gain before replacing the INA111BP. INA128BP, INA129BP, and INA130BP are also offered as same-package candidates, though the verified data contains less detail for them. No substitution should be approved solely from the PDIP-8 footprint; input polarity, RG wiring, gain equation, common-mode range, output swing, supply limits, offset, bandwidth, and stability all require comparison against the manufacturer datasheet.

مقایسه با جایگزین‌ها

پارامتر این محصول INA110BP INA114BP INA128BP INA129BP INA130BP
Package 8-pin PDIP 8-pin PDIP 8-pin PDIP 8-pin PDIP 8-pin PDIP 8-pin PDIP
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Gain Range 1 to greater than 1000 1 to 10,000 1 to 10,000 1 to 10,000 1 to 10,000 1 to 10,000
Special Feature High-speed current-feedback architecture Precision instrumentation amplifier Precision instrumentation amplifier Precision instrumentation amplifier Precision instrumentation amplifier Precision instrumentation amplifier

تفاوت‌های کلیدی

  • Higher verified speed for fast acquisition (در مقابلINA114BP)
  • Faster settling for multiplexed measurement (در مقابلINA114BP)
  • Low input loading for high-impedance sources (در مقابلINA114BP)
  • High slew rate for transient fidelity (در مقابلINA110BP)

یادداشت‌های طراحی

Route the IN- and IN+ paths as a closely matched differential pair, terminate both at the intended source, and keep the external gain-setting resistor close to the relevant RG terminals. According to the Texas Instruments INA111 manufacturer datasheet, correct RG connections are central to obtaining the specified gain and bandwidth. Avoid routing sensitive inputs across switching-node or digital-return paths, and place input protection components close enough to the device that their capacitance does not unnecessarily disturb the input network.

Provide local supply bypassing and connect each ground reference using a low-impedance return path. The INA111BP offers 2 MHz bandwidth at gain 10, so parasitic supply resistance and long ground paths can create measurement errors that are not apparent at low frequency. Use the manufacturer's recommended bypass arrangement, keep the supply trace short, and separate sensitive input returns from power-converter and digital currents. Validate the completed board with an injected-noise test because good schematic decoupling does not compensate for poor PCB topology.

Do not assume that equal package size guarantees an interchangeable amplifier. Before replacing the INA111BP, verify differential-input polarity, the RG connection method, gain equation, supply voltage, common-mode range, output swing, offset, bandwidth, and stability. The INA111BP supports gains from 1 to greater than 1000, while several alternatives extend to 10,000; a different gain equation can change system gain and bandwidth even if the PCB footprint matches.

اطلاعات انطباق

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

The verified source data does not explicitly state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable to this non-automotive instrumentation amplifier unless a separate qualified ordering variant is identified.

تاریخ تأیید داده‌ها: 2026-10-29 — داده‌ها توسط تیم مهندسی قطعات XAIPART تأیید و گردآوری شده است

جستجوهای مرتبط

INA111BP INA111BP datasheet PDF Texas Instruments INA111BP INA111BP 2MHz instrumentation amplifier INA111BP PDIP-8 pinout INA111BP price INA111BP buy online INA111BP lead time and stock INA111BP vs INA114BP INA111BP drop-in replacement high speed FET input instrumentation amplifier INA111BP bridge sensor amplifier INA111BP current shunt measurement What can replace INA111BP? INA111BP gain resistor and bandwidth

قطعات و اصطلاحات مرتبط

Texas Instruments INA111BP INA111 INA110BP INA114BP INA128BP INA129BP INA130BP instrumentation amplifier signal-conditioning IC differential amplifier current-feedback topology FET input common-mode rejection ratio input bias current offset voltage slew rate bandwidth PDIP-8 DIP package family through-hole package surface-mount alternative data acquisition bridge sensor current-shunt monitoring
استعلام قیمت سریع RFQ
جزئیات کامل را پر کنید — تیم فروش ما ظرف 24 ساعت پاسخ خواهد داد
شماره قطعه سازنده بسته‌بندی QTY قیمت هدف قیمت کل
✓
استعلام قیمت ارسال شد!

ظرف ۲۴ ساعت به ایمیل شما پاسخ خواهیم داد

1
درخواست قیمت ارسال شد
2
استعلام دریافت شد
3
سفارش ثبت شد
4
پرداخت
5
ارسال شد
6
تحویل داده شد
مشاهده جزئیات RFQ