INA143U/2K5 - 10V/V Differential Amplifier | Texas Instruments
MPN: INA143U/2K5 ✓ فعالINA143U/2K5 نمای کلی
A difference amplifier is a specialized operational-amplifier circuit that amplifies the voltage difference between two inputs while rejecting voltage shared by both inputs. The INA143 belongs to the instrumentation-amplifier and differential-amplifier hierarchy within the broader linear-IC and signal-conditioning categories. Its internal design provides fixed gain without requiring external gain-setting resistors, helping reduce component count and gain-setting variation.
Key features include selectable gain configurations of 10 V/V or 0.1 V/V within the INA143 family, low gain error of 0.01% maximum, fast settling to 0.01% in 9 ms, and a wide supply range from ±2.25 V to ±18 V. These characteristics suit systems that require accurate differential measurement while operating from dual supplies. The listed operating-temperature range is −40 °C to +85 °C.
The INA143U/2K5 uses internal resistor matching to establish its gain and supports operation with dual positive and negative supplies. Its 5 V/µs slew rate allows the output to respond quickly to input transitions, while the 9 ms settling specification supports applications that repeat measurements at a moderate rate. The 8-SOIC package also provides a compact surface-mount option for industrial and analog signal-chain equipment.
Typical uses include bridge-transducer interfaces, current-loop measurement, laboratory instrumentation, industrial sensor conditioning, and cancellation of common-mode noise in differential sensor outputs. When selecting a circuit, verify the input common-mode range, output swing, supply arrangement, and required settling time against the manufacturer datasheet.
For PCB implementation, treat the input, feedback, reference, and supply connections as sensitive analog paths. Keep input traces short, use a stable reference connection when the output requires an offset, and decouple each supply rail close to the device. Avoid long copper runs between the amplifier and high-impedance sensor nodes to minimize coupled noise and capacitance-related settling changes.
This product page combines the manufacturer specifications with package information, application guidance, and drop-in comparison options. The comparison material highlights the fixed gain, supply range, slew rate, offset, package, and temperature constraints that should be reviewed before replacing an existing INA143U/2K5 in a production design.
جایگزینهای drop-in برای INA143U/2K5 — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
گونهها در این سری
مدلهای همسری که جایگزین مستقیم هستند برای INA143U/2K5 (همان فرمفاکتور و فوتپرینت) — متفاوت در Gain Error, Operating Temperature Range, Package.
INA143U
✅ جایگزین مستقیمبرای قیمت تماس بگیرید
مشاهده دیتاشیت ←INA143U/2K5E4
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
INA132U/2K5
✅ جایگزین مستقیمبرای قیمت تماس بگیرید
مشاهده دیتاشیت ←INA148UA/2K5
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
AD8278ARZ
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
INA143U/2K5 حداکثر مقادیر مجاز و مشخصات الکتریکی
| Amplifier Type | Precision difference amplifier |
| Number of Circuits | 1 circuit |
| Fixed Gain | 10 V/V |
| Alternative Family Gain | 0.1 V/V |
| Gain Error | 0.01% maximum |
| Offset Voltage | ±250 mV maximum |
| Offset Voltage Temperature Drift | ±3 mV/°C maximum |
| Slew Rate | 5 V/µs |
| Settling Time | 9 ms to 0.01% |
| Bandwidth | 150 kHz |
| جریان سکون | 950 mA |
| Supply Voltage Range | ±2.25 V to ±18 V |
| محدوده دمای کاری | −40 °C to +85 °C |
| بستهبندی | 8-SOIC (D), 0.154 inch nominal width |
| تعداد پایه | 8 pins |
| نوع نصب | Surface mount |
پیکربندی پین INA143U/2K5
| پین 1 | −IN — Inverting input |
| پین 2 | +IN — Noninverting input |
| پین 3 | V− — Negative supply connection |
| پین 4 | REF — Reference input |
| پین 5 | OUT — Amplified output |
| پین 6 | V+ — Positive supply connection |
| پین 7 | +IN — Noninverting input |
| پین 8 | −IN — Inverting input |
کاربردهای معمول
INA143U/2K5 مناسب است برای 6 کاربردs: Bridge Transducer Signal Conditioning, Industrial Sensor Amplification, Current Loop Measurement, Laboratory Instrumentation, Common-Mode Noise Rejection, Data Acquisition Front End.
Bridge Transducer Signal Conditioning
The INA143U/2K5 fits bridge-based pressure, strain, and load-cell interfaces that produce a small differential signal on top of a larger common-mode voltage. Its fixed 10 V/V gain avoids external gain-setting resistors, while the specified 0.01% maximum gain error and ±250 mV maximum offset support controlled measurement-chain behavior. Place the amplifier close to the bridge inputs, use short guarded traces, and verify that the bridge excitation voltage keeps both inputs inside the amplifier’s common-mode range. The dual supply capability of ±2.25 V to ±18 V supports bipolar bridge excitation, although the exact excitation level must be checked against the input and output limits in the manufacturer datasheet.
پیشنهادی
Industrial Sensor Amplification
The INA143U/2K5 is appropriate for industrial sensor outputs where a differential voltage must be converted into a stronger signal for an ADC or controller. The 10 V/V fixed gain reduces circuit complexity, and the 5 V/µs slew rate supports faster transitions than a low-speed precision amplifier. Its ±2.25 V to ±18 V supply range allows operation from compact dual analog rails to higher industrial voltage spans. For reliable results, establish an analog ground reference near the sensor, decouple each supply rail at the package, and avoid routing the sensor directly beneath digital clock or switching nodes. Verify settling time when the measurement system must resolve small changes rapidly after an input step.
پیشنهادی
Current Loop Measurement
The INA143U/2K5 can amplify the differential voltage generated by a current-sense shunt or precision current-measurement circuit. Its fixed gain of 10 V/V provides predictable scaling, while low offset and low gain error help preserve measurement accuracy. The device is best placed after a low-value shunt so that the amplifier does not exceed its common-mode input limits, and Kelvin-style routing should be used to prevent voltage drops in the shunt traces from appearing as measurement error. Bypass each supply rail with local high-frequency decoupling and connect the signal-reference pin to the measurement ground through the arrangement specified by the manufacturer datasheet. The 9 ms settling specification should be checked against the required loop response.
پیشنهادی
Laboratory Instrumentation
The INA143U/2K5 suits laboratory front ends that measure small differential signals in the presence of common-mode voltage. The 10 V/V gain, 0.01% maximum gain error, and ±250 mV maximum offset provide a defined starting point for precision measurement circuitry. Use the reference connection to establish the output operating point required by the following stage, and keep sensitive input nodes away from switching regulators and high-current return paths. Because the listed bandwidth is 150 kHz, the device is better matched to moderate-bandwidth measurements than to wideband waveform systems. For instrumentation requiring faster settling, use the manufacturer’s timing and output-swing curves to establish the usable operating bandwidth.
پیشنهادی
Common-Mode Noise Rejection
The INA143U/2K5 is useful when the wanted information is carried as a small differential voltage and unwanted voltage appears equally on both signal inputs. Its difference-amplifier architecture provides common-mode rejection, allowing the circuit to suppress shared disturbances more effectively than a single-ended amplifier arrangement. Place the two input paths symmetrically so that coupling from nearby switching nodes is balanced, and keep the input impedance consistently loaded on both channels. Verify the operating frequency against the specified 150 kHz bandwidth and confirm the input common-mode range. The 5 V/µs slew rate helps preserve timing margin when the differential signal changes quickly.
پیشنهادی
Data Acquisition Front End
The INA143U/2K5 can provide the analog gain stage ahead of an ADC in a data-acquisition system. Its fixed 10 V/V gain increases the useable span of a low-level differential input without adding external gain resistors, while the low gain error and specified offset establish predictable scale factors. Place the amplifier and its decoupling capacitors close to the ADC source, route the differential pair together, and provide a clean reference to the acquisition ground. The listed 9 ms settling time is suitable for many moderate-rate measurement channels but may limit very fast conversion sequences. Verify the ADC acquisition window, amplifier settling, and output-voltage limits together rather than optimizing each block independently.
پیشنهادی
خلاصه محصولات پیشنهادی
دادههای مرجع مهندسی برای INA143U/2K5 — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
مقایسه با جایگزینها
| پارامتر | این محصول | INA143U | INA143U/2K5E4 | INA132U/2K5 | INA148UA/2K5 | AD8278ARZ |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Package | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC (D) |
| Differential Input Support | Difference amplifier | Difference amplifier | Difference amplifier | Difference amplifier | Difference amplifier | Difference amplifier |
تفاوتهای کلیدی
- Matches the same-family 10 V/V gain configuration and 8-SOIC footprint (در مقابلINA143U)
- Combines 10 V/V gain with a 5 V/µs slew rate (در مقابلINA132U/2K5)
- Uses a manufacturer-defined 150 kHz bandwidth and 9 ms settling specification (در مقابلAD8278ARZ)
- Supports bipolar operation from ±2.25 V to ±18 V (در مقابلINA148UA/2K5)
یادداشتهای طراحی
Keep the two input nets short, closely coupled, and symmetrical so that noise or parasitic capacitance affects both inputs similarly. Place the INA143U/2K5 near the sensor or source connector, and avoid routing sensitive inputs beneath switching nodes, high-current supply paths, and digital return currents. Use a continuous ground plane where practical, but partition high-current return paths so their magnetic fields do not couple into the input loop.
Decouple the positive and negative supply pins independently with capacitors placed directly beside the corresponding package pins. Select capacitor voltage ratings and effective capacitance for the operating frequency because ceramic capacitance can decrease substantially with bias. Confirm the complete supply range, quiescent-current behavior, and output-swing limits in the manufacturer datasheet. Estimated power dissipation is equal to the total supply voltage multiplied by supply current only after accounting for the actual output operating point; no specific thermal estimate is asserted without those circuit conditions.
Do not assume that an 8-SOIC footprint proves functional compatibility. Before replacing the INA143U/2K5, compare gain, input common-mode range, output swing, supply voltage, reference behavior, offset, bandwidth, slew rate, and settling time. Pay particular attention to the fixed 10 V/V gain and the INA143 family’s gain-configuration pins. Validate the substitute across temperature, supply tolerance, source impedance, and sensor excitation conditions rather than checking nominal values alone.
The listed 150 kHz bandwidth and 9 ms settling to 0.01% define separate limits on sinusoidal and step-response behavior. For an ADC front end, include the amplifier’s settling interval in the acquisition timing and ensure the source impedance produces the response expected by the manufacturer model. If the input is AC-coupled, check that the coupling network does not create additional phase error or an unintended low-frequency corner.
INA143U/2K5 uses an 8-SOIC package, so copper area and airflow affect thermal performance. Estimated junction temperature is the ambient temperature plus the calculated power dissipation multiplied by the effective junction-to-ambient thermal resistance. Obtain the input values from the final schematic, package thermal data, and PCB layout before applying that calculation. Increase copper area, improve airflow, or reduce dissipation if the calculated junction temperature exceeds the design limit.
اطلاعات انطباق
The operating-temperature and package information are listed by Texas Instruments. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the current manufacturer product documentation or orderable-device information.