ISL83490IP - 3.3V Full-Duplex RS-485 Transceiver | Renesas
MPN: ISL83490IP ✓ فعالISL83490IP نمای کلی
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into differential bus voltages and converts differential bus signals back into receiver-compatible logic. The ISL83490IP combines both functions in one package, placing it within the hierarchy of interface transceivers, wired-communication ICs, and semiconductors. Separate transmit and receive paths support full-duplex systems, allowing a controller to transmit and receive data simultaneously over two differential pairs.
Key characteristics include a 3 V to 3.6 V supply range, one driver and one receiver, full-duplex operation, and support for both RS-485 and RS-422 communication protocols. Its 3.3 V supply operation suits modern embedded systems where 5 V interface devices may be undesirable. The through-hole 8-DIP construction also makes it practical for prototypes, industrial control equipment, legacy systems, and repair assemblies that favor socketed or leaded parts over fine-pitch surface-mount packages.
The ISL83490IP is intended for high-speed or slew-rate-limited differential communication. Controlled slew behavior helps limit unwanted transitions on the bus, while the low-power 3.3 V design can simplify interface design around low-voltage controllers. The transceiver architecture requires correct termination, biasing, grounding, and isolation practices to achieve reliable operation in multi-node RS-485 networks.
Typical uses include industrial serial controllers, factory automation equipment, building-control interfaces, test and measurement systems, motor-control diagnostics, and embedded communications modules. In each application, the IC can bridge a controller's UART or logic signals to a differential RS-485 or RS-422 bus, reducing wiring susceptibility to common-mode noise compared with single-ended signaling.
Designers should follow the pin-description table in the manufacturer datasheet when assigning PCB tracks and should preserve the specified supply decoupling arrangement. Cable length, topology, data rate, termination resistance, common-mode range, and grounding determine whether the complete communications link is reliable; successful transceiver selection alone does not guarantee standards-compliant operation.
This page combines interface classification, package and supply characteristics, application guidance, comparison parameters, and practical design notes to support evaluation of the ISL83490IP in low-voltage RS-485 and RS-422 systems.
جایگزینهای drop-in برای ISL83490IP — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
گونهها در این سری
مدلهای همسری که جایگزین مستقیم هستند برای ISL83490IP (همان فرمفاکتور و فوتپرینت) — متفاوت در Duplex Mode, Maximum Data Rate, Package, Product Type, Transceiver Configuration.
SP3490EP-L
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
ISL83490IP مشخصات
| Product Type | RS-485/RS-422 transceiver IC |
| Number of Drivers | 1 driver |
| Number of Receivers | 1 receiver |
| Duplex Mode | Full duplex |
| Supported Protocols | RS-485 and RS-422 |
| Supply Voltage Range | 3 V to 3.6 V |
| Nominal Supply Voltage | 3.3 V |
| Power Class | Low power |
| Signal Profile | High speed or slew-rate limited |
| محدوده دمای کاری | -40 °C to +85 °C |
| Package Type | 8-DIP, through hole |
| Package Lead Span | 0.300 inch (7.62 mm) |
| نوع نصب | Through-hole |
| Shipping Container | Tube |
| Operating Temperature Grade | Industrial, -40 °C to +85 °C |
راهنمای پیکربندی پین ISL83490IP 0.300 inch (7.62 mm)
پیکربندی پین برای ISL83490IP (پکیج 0.300 inch (7.62 mm)). شمارهگذاری پایهها، عملکردها و نمودارهای اتصال در دیتاشیت سازنده تعریف شده است. برای footprint دقیق و دستورالعملهای لحیمکاری به آن مراجعه کنید.
داده پینآوت تفصیلی موجود نیست برای ISL83490IP.
به دیتاشیت برای پیکربندی کامل پینها.
کاربردهای معمول
ISL83490IP مناسب است برای 6 کاربردs: Industrial Automation Serial Interfaces, Building Control and HVAC Networks, Test and Measurement Equipment, Embedded Data Acquisition Modules, Motor Control and Machinery Diagnostics, Legacy Communications and Field-Serviceable Boards.
Industrial Automation Serial Interfaces
The ISL83490IP fits industrial automation controllers that connect a low-voltage UART or control logic to an RS-485 or RS-422 field bus. Its 3 V to 3.6 V supply aligns with 3.3 V embedded logic, while the one-driver, one-receiver arrangement supports full-duplex data exchange. According to the manufacturer datasheet, the device operates from -40 °C to +85 °C. A typical implementation places the transceiver between the controller and protected bus connector, adding common-mode protection and the required termination or bias components. The 8-DIP through-hole package is also convenient for prototypes, socketed controller boards, and repairable industrial equipment. Designers should verify driver strength, receiver thresholds, isolation requirements, and grounding against their cable and topology.
پیشنهادی
Building Control and HVAC Networks
The ISL83490IP is appropriate for building-control and HVAC equipment that distributes commands over a balanced RS-485 network. Its 3.3 V operating range suits modern controller boards, and the full-duplex driver and receiver pair supports simultaneous command transmission and sensor-response reception. According to the manufacturer datasheet, the IC covers the -40 °C to +85 °C industrial temperature range and can operate in high-speed or slew-rate-limited applications. Place it near the controller or wiring interface, provide local supply decoupling, and use protection suited to the building's cable environment. Because building networks can experience ground-potential differences and surge events, external protection and an isolated interface may be needed even when the transceiver itself meets the basic RS-485 or RS-422 requirements.
پیشنهادی
Test and Measurement Equipment
The ISL83490IP can serve as the communications interface in test and measurement equipment that must exchange commands and results over a reliable differential bus. Its full-duplex configuration permits continuous two-way control, while operation from 3 V to 3.6 V supports compact instrumentation built around low-voltage logic. According to the manufacturer datasheet, the device provides one driver, one receiver, and RS-485/RS-422 protocol support. In an instrument, the transceiver can connect a controller to a rear-panel connector or multipoint bus. Keep the analog and digital ground strategy defined by the complete instrument, verify common-mode limits before installation, and add external surge protection for cables that leave the enclosure. The 8-DIP package also simplifies through-hole prototypes and field-serviceable assemblies.
پیشنهادی
Embedded Data Acquisition Modules
The ISL83490IP is useful in embedded data-acquisition modules that need to distribute sensor readings or configuration commands over a multi-drop RS-485 network. Its low 3.3 V supply requirement simplifies interface design around compact controllers, while the transceiver's driver and receiver support a single-channel full-duplex arrangement. According to the manufacturer datasheet, the operating-temperature range is -40 °C to +85 °C. A practical module can use the IC between the controller UART and a protected terminal block, with biasing and termination placed according to the network topology. The system's cable length, node count, and data rate must be considered because they determine the usable communications margin. The through-hole 8-DIP package is especially practical for prototype modules and designs assembled with sockets or leaded components.
پیشنهادی
Motor Control and Machinery Diagnostics
The ISL83490IP fits motor controllers and machinery-diagnostic equipment that exchange commands, status, and fault data over a differential bus. The 3 V to 3.6 V operation is compatible with modern control electronics, and the full-duplex driver and receiver allow a controller to issue commands while receiving diagnostic feedback. According to the manufacturer datasheet, the transceiver is rated from -40 °C to +85 °C, making it appropriate for many industrial environments. In a motor-control design, install the interface near the controller connector and isolate noisy motor-drive circuitry from sensitive communications routing. External protection may be necessary when the bus cable experiences motor transients or large ground-potential differences. Verify signal timing and bus loading against the complete motor network rather than relying on transceiver selection alone.
پیشنهادی
Legacy Communications and Field-Serviceable Boards
The ISL83490IP is a practical choice for legacy communication boards, conversion equipment, and field-serviceable products that favor a leaded package. According to the manufacturer datasheet, it is an 8-DIP through-hole device with a 0.300-inch, or 7.62 mm, lead span and a -40 °C to +85 °C operating range. Its 3.3 V supply suits modern controller logic without requiring a 5 V transceiver. Through-hole construction simplifies socketed assembly, point-to-point wiring in simple equipment, and repair workflows that favor replaceable components. The full-duplex RS-485/RS-422 function can support a modern controller communicating with older differential equipment, although logic levels, timing, and termination must be reconciled. Board layout should follow the manufacturer pin table and preserve the recommended decoupling arrangement.
پیشنهادی
خلاصه محصولات پیشنهادی
دادههای مرجع مهندسی برای ISL83490IP — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
مقایسه با جایگزینها
| پارامتر | این محصول | SP3490EP-L |
|---|---|---|
| Brand | Renesas Electronics | Diodes Incorporated |
| Package | 8-DIP (0.300 inch, 7.62 mm) | 8-DIP (0.300 inch, 7.62 mm) |
| Mounting Type | Through hole | Through hole |
تفاوتهای کلیدی
- Low-voltage operation matches modern 3.3 V controller logic (در مقابلSP3490EP-L)
- Full-duplex differential interface in a through-hole package (در مقابلSP3490EP-L)
- Supports both RS-485 and RS-422 interfaces (در مقابلSP3490EP-L)
یادداشتهای طراحی
Use the manufacturer datasheet's 8-DIP pin-description table as the authoritative assignment for supply, ground, enable, driver, and receiver signals. Place the recommended input and output bypass capacitors adjacent to their associated pins and keep their ground returns short. For a differential bus, route the driver and receiver traces as a closely matched pair, minimize stubs, and keep switching or high-current return paths away from the communications nodes. The 7.62 mm lead pitch requires a compatible 0.300-inch DIP footprint rather than a narrow-pitch SOIC land pattern.
Do not treat the RS-485 or RS-422 protocol name as a guarantee that any wiring arrangement will work. Match termination to the cable and topology, install biasing only where the network design requires it, and account for common-mode voltage, cable length, node count, and data rate. Verify that the chosen receiver thresholds satisfy the intended noise margin. According to the manufacturer datasheet, the ISL83490IP supports both protocols, but the external network and protection components determine actual link reliability.
Use controlled slew behavior to reduce reflected transitions and radiated noise, especially on long or poorly terminated cables. Place optional protection devices near the external connector so surge or electrostatic-discharge energy is clamped before reaching the transceiver. Provide a defined ground strategy for interfaces that bridge separated equipment; if large ground-potential differences are possible, evaluate galvanic isolation rather than relying on the IC alone. After layout changes, verify both radiated emissions and susceptibility in the complete enclosure and cable configuration.
اطلاعات انطباق
The -40 °C to +85 °C operating range is not equivalent to AEC-Q100 qualification. No additional RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations were established from the referenced manufacturer documents.