AD625CD - Programmable Gain Amplifier | Analog Devices
Référence : AD625CD ✗ Fin de vieAD625CD Présentation
An instrumentation amplifier is a differential analog signal-conditioning IC that combines input buffering, differential amplification, and gain-setting circuitry in one package. Its hierarchy includes instrumentation amplifier, analog signal conditioner, analog IC, and semiconductor. This category is particularly useful for amplifying small differential sensor signals while rejecting common-mode noise and voltage applied simultaneously to both inputs.
The AD625CD provides a maximum gain error of 0.02%, a maximum gain temperature coefficient of 5 ppm/°C, a maximum nonlinearity of 0.001%, and a maximum offset voltage of 25 µV. These characteristics support accurate measurement systems in which gain drift and signal-chain distortion directly affect result repeatability. The broad 10-to-10,000 gain range covers load-cell, strain-gauge, pressure-transducer, and laboratory measurement interfaces.
Its 25 MHz gain-bandwidth product provides useful bandwidth for low-frequency precision measurements and instrumentation. The specified 4 nV/√Hz input noise at 1 kHz helps preserve weak-signal information, while the low gain error and temperature coefficient support stable calibration over changing ambient conditions. The 16-CDIP package is suitable for conventional through-hole assembly where a mechanically robust ceramic package is preferred.
Typical uses include bridge-transducer amplification, precision current measurement, laboratory data acquisition, biomedical instrumentation, and industrial monitoring. In a bridge circuit, the AD625CD can amplify the small differential voltage generated by a strain gauge while rejecting ground-level common-mode voltage. In current sensing, its programmable gain allows the output range to be matched to the available analog-to-converter input range.
When designing the signal path, place the gain-setting network close to the device and observe the input common-mode and output-swing limits in the manufacturer datasheet. Check the required gain against the 25 MHz gain-bandwidth product so that the closed-loop bandwidth remains appropriate for the measurement bandwidth.
This page combines the AD625CD device characteristics, lifecycle status, application guidance, and design considerations into a practical engineering reference for evaluating this programmable instrumentation amplifier.
Alternatives de remplacement direct pour AD625CD — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD625CD (même facteur de forme et même empreinte) — différant par Package, Product Type.
AD625CN
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
AD625CNZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
AD625CDZ
✅ Remplacement direct ⚠️ Spécifications non vérifiéesContactez-nous pour le prix
Voir la fiche technique →AD625CD Valeurs maximales et caractéristiques électriques
| Product Type | Programmable-gain instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Programmed Gain Range | 10 to 10,000 |
| Maximum Gain Error | 0.02% |
| Maximum Gain Temperature Coefficient | 5 ppm/°C |
| Maximum Nonlinearity | 0.001% |
| Maximum Offset Voltage | 25 µV |
| Input Noise Density | 4 nV/√Hz at 1 kHz |
| Gain-Bandwidth Product | 25 MHz |
| Boîtier | 16-lead ceramic dual-in-line package (16-CDIP) |
| Terminal Count | 16 terminals |
| Type de montage | Through-hole |
| Temperature Grade | Industrial |
Guide de configuration des broches du AD625CD 16-lead ceramic dual-in-line package (16-cdip)
Configuration des broches du AD625CD (boîtier 16-lead ceramic dual-in-line package (16-cdip)). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD625CD.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD625CD convient pour 6 applications: Load-Cell Signal Conditioning, Strain-Gauge Measurement, Precision Current Sensing, Laboratory Data Acquisition, Biomedical Instrumentation, Industrial Process Monitoring.
Load-Cell Signal Conditioning
The AD625CD fits load-cell bridges whose output can range widely with excitation voltage, mechanical load, and bridge impedance. Its programmable gains from 10 to 10,000 allow the analog signal chain to be scaled without switching to unrelated amplifier families. The 4 nV/√Hz input noise at 1 kHz helps preserve small bridge differentials, while the 25 MHz gain-bandwidth product provides bandwidth beyond typical low-frequency weighing systems. Designers should verify the selected gain against the required measurement bandwidth and use the manufacturer input common-mode limits when setting the bridge excitation.
Strain-Gauge Measurement
A strain gauge connected to a resistive bridge produces a small differential voltage that the AD625CD can amplify for measurement or conversion. The maximum gain error of 0.02% and gain temperature coefficient of 5 ppm/°C help maintain calibration accuracy, while the 25 µV maximum offset voltage limits a significant source of low-level measurement error. The 10-to-10,000 programmable range supports different gauge sensitivities and mechanical test ranges. Keep the gain-setting components close to the amplifier and confirm that bridge excitation and common-mode voltage remain within the device operating limits.
Precision Current Sensing
The AD625CD can condition the differential output of a high-side or low-side current-sense amplifier when very small sensor voltages require accurate amplification. Its 4 nV/√Hz input noise at 1 kHz reduces the amplifier's contribution to the measurement floor, and programmable gain from 10 to 10,000 allows output range optimization for an analog-to-converter. The 25 MHz gain-bandwidth product supports bandwidth well above many power-monitoring applications. Final design work must include offset, common-mode, output-swing, and settling checks for the selected sensor and system gain.
Laboratory Data Acquisition
The AD625CD is useful as the analog front end of a laboratory measurement system that accepts programmable differential inputs at different sensitivities. Its gain range from 10 to 10,000 lets one instrument design cover multiple transducers without excessive fixed-gain stages. Low input noise of 4 nV/√Hz at 1 kHz, maximum nonlinearity of 0.001%, and maximum gain error of 0.02% support accurate capture of low-level signals. Engineers should calculate closed-loop bandwidth from the 25 MHz gain-bandwidth product and include settling time in the measurement acquisition sequence.
Biomedical Instrumentation
The AD625CD can amplify low-level differential signals from biomedical sensors when the system requires broad gain adjustment and low-noise input characteristics. The 4 nV/√Hz noise density at 1 kHz helps avoid masking small sensor outputs, while programmable gains from 10 to 10,000 support different electrode or transducer sensitivities. Medical-system design also requires careful isolation, protection, grounding, patient-safety review, and regulatory validation beyond the amplifier specifications. The manufacturer input limits and output-swing requirements must be checked in the final signal chain.
Industrial Process Monitoring
The AD625CD suits industrial process-monitoring systems that measure small differential signals from pressure, temperature, or resistive transducers. Its programmable gain allows one analog channel to cover different sensor ranges, while 0.02% maximum gain error and 5 ppm/°C maximum gain temperature coefficient support repeatable measurements. The 25 MHz gain-bandwidth product allows useful bandwidth margin for many process-control signals. For long cable runs and grounded sensors, verify common-mode range, grounding strategy, filtering, and surge protection before applying power.
Données de référence d'ingénierie pour AD625CD — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD625CN | AD625CNZ | AD625CDZ |
|---|---|---|---|---|
| Package | 16-CDIP | 16-CDIP | 16-CDIP | 16-CDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier |
| Programmed Gain Range | 10 to 10,000 | 10 to 10,000 | 10 to 10,000 | 10 to 10,000 |
Principaux différenciateurs
- Broad programmable gain range (vs AD624)
- Precision gain calibration (vs AD625CN)
- Low-noise input stage (vs AD625CDZ)
Notes de conception
Do not select the gain without checking the resulting closed-loop bandwidth. The AD625CD has a 25 MHz gain-bandwidth product, so a high programmed gain reduces the bandwidth available for settling and signal fidelity. Use the manufacturer gain equations and bandwidth relationship for the selected configuration, then verify that the measurement bandwidth and settling interval remain adequate.
Route the differential input pair as a short, closely coupled pair and connect the gain-setting components close to the corresponding IC pins. This minimizes susceptibility to parasitic pickup and ground-current-induced errors. Keep high-current return paths away from the input and gain nodes, and use a quiet ground reference for the analog circuitry.
Check input common-mode voltage, output swing, supply voltage, and gain constraints before finalizing the bridge or sensor interface. The 25 µV maximum offset specification alone does not guarantee correct operation if the input leaves its valid common-mode region. Include sensor excitation tolerance, cable-induced offsets, and analog-to-converter input range in the worst-case signal-chain calculation.
Because the AD625 family is not recommended for new designs, preserve the original footprint and pin assignments if maintaining an existing board is the objective. Confirm the exact ordering code, ceramic-DIP package, temperature grade, and lifecycle status before placing a maintenance order. A family member with a similar description should not be installed without checking its complete pin and electrical descriptions.
Informations de conformité
The AD625 family is identified as not recommended for new designs. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations for the exact AD625CD ordering code were not identified.