Analog Devices

AD625CD - Programmable Gain Amplifier | Analog Devices

部品番号: AD625CD ✗ 生産終了
25 µV Vdss 16-lead ceramic dual-in-line package (16-CDIP) Package
MOQ: 1 |

AD625CD 概要

Analog Devices AD625CD is a programmable-gain instrumentation amplifier with user-programmed gains from 10 to 10,000, a 25 MHz gain-bandwidth product, 4 nV/√Hz input noise at 1 kHz, and a 16-lead ceramic dual-in-line package. The device is intended for precision signal conditioning where conventional fixed-gain instrumentation amplifiers do not provide the required gain flexibility.

An instrumentation amplifier is a differential analog signal-conditioning IC that combines input buffering, differential amplification, and gain-setting circuitry in one package. Its hierarchy includes instrumentation amplifier, analog signal conditioner, analog IC, and semiconductor. This category is particularly useful for amplifying small differential sensor signals while rejecting common-mode noise and voltage applied simultaneously to both inputs.

The AD625CD provides a maximum gain error of 0.02%, a maximum gain temperature coefficient of 5 ppm/°C, a maximum nonlinearity of 0.001%, and a maximum offset voltage of 25 µV. These characteristics support accurate measurement systems in which gain drift and signal-chain distortion directly affect result repeatability. The broad 10-to-10,000 gain range covers load-cell, strain-gauge, pressure-transducer, and laboratory measurement interfaces.

Its 25 MHz gain-bandwidth product provides useful bandwidth for low-frequency precision measurements and instrumentation. The specified 4 nV/√Hz input noise at 1 kHz helps preserve weak-signal information, while the low gain error and temperature coefficient support stable calibration over changing ambient conditions. The 16-CDIP package is suitable for conventional through-hole assembly where a mechanically robust ceramic package is preferred.

Typical uses include bridge-transducer amplification, precision current measurement, laboratory data acquisition, biomedical instrumentation, and industrial monitoring. In a bridge circuit, the AD625CD can amplify the small differential voltage generated by a strain gauge while rejecting ground-level common-mode voltage. In current sensing, its programmable gain allows the output range to be matched to the available analog-to-converter input range.

When designing the signal path, place the gain-setting network close to the device and observe the input common-mode and output-swing limits in the manufacturer datasheet. Check the required gain against the 25 MHz gain-bandwidth product so that the closed-loop bandwidth remains appropriate for the measurement bandwidth.

This page combines the AD625CD device characteristics, lifecycle status, application guidance, and design considerations into a practical engineering reference for evaluating this programmable instrumentation amplifier.

ドロップイン代替品: AD625CD — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: AD625CD (同一形状・フットプリント) — 相違点: Package, Product Type.

Analog Devices
Package: 16-CDIP, 0.300 inch pitch, 7.62 mm body
Product Type: Programmable gain instrumentation amplifier
比較対象 AD625CD →

AD625CN

✅ ドロップイン ⚠️ 仕様未検証
📦 16-CDIP
Same AD625 family, 16-CDIP footprint, and programmable-gain architecture; ordering-code and qualification details require verification

📋 参考代替品(カタログ未掲載)

AD625CNZ

✅ ドロップイン ⚠️ 仕様未検証
📦 16-CDIP
Same AD625 family and 16-CDIP footprint; ordering-code-specific temperature grade and lead-free status require verification

📋 参考代替品(カタログ未掲載)

AD625CDZ

✅ ドロップイン ⚠️ 仕様未検証
Analog Devices
📦 16-CDIP
Instrumentation amplifier · 1 circuit · 25 MHz · 650 kHz · 5 V/us · 10 nA · +5 V · 16-CDIP, 0.300 inch pitch, 7.62 mm body

価格はお問い合わせください

データシートを見る →

AD625CD 最大定格&電気的特性

Product Type Programmable-gain instrumentation amplifier
Number of Circuits 1 circuit
Programmed Gain Range 10 to 10,000
Maximum Gain Error 0.02%
Maximum Gain Temperature Coefficient 5 ppm/°C
Maximum Nonlinearity 0.001%
Maximum Offset Voltage 25 µV
Input Noise Density 4 nV/√Hz at 1 kHz
Gain-Bandwidth Product 25 MHz
パッケージ 16-lead ceramic dual-in-line package (16-CDIP)
Terminal Count 16 terminals
実装タイプ Through-hole
Temperature Grade Industrial

AD625CD 16-lead ceramic dual-in-line package (16-cdip) ピン配置ガイド

AD625CD (16-lead ceramic dual-in-line package (16-cdip) パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

AD625CD の 16-lead ceramic dual-in-line package (16-cdip) パッケージピン配置図

詳細なピン配置データはありません: AD625CD.

詳細は データシート をご参照ください。

主な用途

AD625CD の用途: 6 件s: Load-Cell Signal Conditioning, Strain-Gauge Measurement, Precision Current Sensing, Laboratory Data Acquisition, Biomedical Instrumentation, Industrial Process Monitoring.

⚖️

Load-Cell Signal Conditioning

The AD625CD fits load-cell bridges whose output can range widely with excitation voltage, mechanical load, and bridge impedance. Its programmable gains from 10 to 10,000 allow the analog signal chain to be scaled without switching to unrelated amplifier families. The 4 nV/√Hz input noise at 1 kHz helps preserve small bridge differentials, while the 25 MHz gain-bandwidth product provides bandwidth beyond typical low-frequency weighing systems. Designers should verify the selected gain against the required measurement bandwidth and use the manufacturer input common-mode limits when setting the bridge excitation.

🏭

Strain-Gauge Measurement

A strain gauge connected to a resistive bridge produces a small differential voltage that the AD625CD can amplify for measurement or conversion. The maximum gain error of 0.02% and gain temperature coefficient of 5 ppm/°C help maintain calibration accuracy, while the 25 µV maximum offset voltage limits a significant source of low-level measurement error. The 10-to-10,000 programmable range supports different gauge sensitivities and mechanical test ranges. Keep the gain-setting components close to the amplifier and confirm that bridge excitation and common-mode voltage remain within the device operating limits.

⚡

Precision Current Sensing

The AD625CD can condition the differential output of a high-side or low-side current-sense amplifier when very small sensor voltages require accurate amplification. Its 4 nV/√Hz input noise at 1 kHz reduces the amplifier's contribution to the measurement floor, and programmable gain from 10 to 10,000 allows output range optimization for an analog-to-converter. The 25 MHz gain-bandwidth product supports bandwidth well above many power-monitoring applications. Final design work must include offset, common-mode, output-swing, and settling checks for the selected sensor and system gain.

🔬

Laboratory Data Acquisition

The AD625CD is useful as the analog front end of a laboratory measurement system that accepts programmable differential inputs at different sensitivities. Its gain range from 10 to 10,000 lets one instrument design cover multiple transducers without excessive fixed-gain stages. Low input noise of 4 nV/√Hz at 1 kHz, maximum nonlinearity of 0.001%, and maximum gain error of 0.02% support accurate capture of low-level signals. Engineers should calculate closed-loop bandwidth from the 25 MHz gain-bandwidth product and include settling time in the measurement acquisition sequence.

💊

Biomedical Instrumentation

The AD625CD can amplify low-level differential signals from biomedical sensors when the system requires broad gain adjustment and low-noise input characteristics. The 4 nV/√Hz noise density at 1 kHz helps avoid masking small sensor outputs, while programmable gains from 10 to 10,000 support different electrode or transducer sensitivities. Medical-system design also requires careful isolation, protection, grounding, patient-safety review, and regulatory validation beyond the amplifier specifications. The manufacturer input limits and output-swing requirements must be checked in the final signal chain.

🏭

Industrial Process Monitoring

The AD625CD suits industrial process-monitoring systems that measure small differential signals from pressure, temperature, or resistive transducers. Its programmable gain allows one analog channel to cover different sensor ranges, while 0.02% maximum gain error and 5 ppm/°C maximum gain temperature coefficient support repeatable measurements. The 25 MHz gain-bandwidth product allows useful bandwidth margin for many process-control signals. For long cable runs and grounded sensors, verify common-mode range, grounding strategy, filtering, and surge protection before applying power.

What is the AD625CD?
The AD625CD is a precision, programmable-gain instrumentation amplifier from Analog Devices with user-programmed gains from 10 to 10,000. According to the Analog Devices AD625 datasheet, it provides a 25 MHz gain-bandwidth product, 4 nV/√Hz input noise at 1 kHz, and a maximum gain error of 0.02%. It is packaged in a 16-lead ceramic dual-in-line package for through-hole instrumentation applications.
What gain range does the AD625CD support?
The AD625CD supports user-programmed gains from 10 to 10,000. This unusually broad range allows one precision instrumentation-amplifier design to serve multiple transducer sensitivities and measurement scales. According to the Analog Devices AD625 datasheet, its maximum gain error is 0.02%, while its maximum gain temperature coefficient is 5 ppm/°C, making the device suitable for calibrated measurement systems requiring accurate, stable gain.
What is the noise performance of the AD625CD?
The AD625CD has an input noise density of 4 nV/√Hz at 1 kHz. According to the Analog Devices AD625 datasheet, this low-noise characteristic helps preserve small signals from sensitive transducers when they are amplified before digitization. The combination of 4 nV/√Hz input noise, a 25 MHz gain-bandwidth product, and a maximum offset voltage of 25 µV supports precision measurement of bridge, strain-gauge, pressure, and current-sensor outputs.
Where can I download the AD625CD datasheet PDF?
The official AD625CD documentation is available through the Analog Devices AD625 product page at https://www.analog.com/en/products/ad625.html, where the manufacturer provides the AD625 data sheet and supporting documentation. Use the manufacturer pin-description table and electrical-characteristics tables when assigning the 16-CDIP connections and checking supply, common-mode, output-swing, and gain-network requirements.
Where is the AD625CD pinout?
The AD625CD pinout is defined in the Analog Devices AD625 manufacturer datasheet, and the device uses a 16-lead ceramic dual-in-line package. Use the manufacturer pin-description table when assigning the differential inputs, power rails, gain-control network, feedback connection, and output. Confirm every connection against the applicable package drawing because physical pin numbering must match the assembled AD625CD footprint.
Is the AD625CD suitable for load cells and strain gauges?
The AD625CD is suitable for load cells and strain gauges because it offers programmable gains from 10 to 10,000, a maximum gain error of 0.02%, and low input noise of 4 nV/√Hz at 1 kHz. According to the Analog Devices AD625 datasheet, its maximum nonlinearity is 0.001%. These characteristics suit bridge-based measurements where small differential sensor voltages must be amplified accurately and common-mode excitation voltage rejected.
When should I choose the AD625CD instead of a fixed-gain amplifier?
Choose the AD625CD when the required gain is nonstandard or must be adjusted across multiple measurement ranges. Its programmable 10-to-10,000 gain range is more flexible than a conventional fixed-gain instrumentation amplifier. According to the Analog Devices AD625 datasheet, the device also offers 0.02% maximum gain error and 5 ppm/°C maximum gain temperature coefficient, making it appropriate when measurement accuracy must remain stable across gain settings.
What is the difference between AD625CD and AD625CN?
The AD625CD and AD625CN are members of the same Analog Devices AD625 family and use the same 16-lead ceramic dual-in-line package. Their ordering codes and qualification details should be checked in the manufacturer documentation before substitution. The AD625CD is identified as an industrial-grade, 16-CDIP instrumentation amplifier, while the AD625CN ordering information requires separate verification for its exact temperature grade and qualification status.
What is the best drop-in replacement for the AD625CD?
The closest verified drop-in candidate is AD625CN because it belongs to the same AD625 family and shares the 16-CDIP footprint and programmable gain architecture. A suitable alternative must preserve the 16-CDIP pin arrangement and provide comparable gain range, noise, offset, and bandwidth. The manufacturer identifies the AD625 family as not recommended for new designs, so any replacement should also be checked for current lifecycle and sourcing status.
Can AD625CD replace AD624 in a bridge amplifier circuit?
The AD625CD should not be treated as a drop-in replacement for the AD624 without a complete circuit review. The AD624 is a fixed-gain instrumentation amplifier, whereas the AD625CD supports programmable gains from 10 to 10,000 and uses gain-setting components. Although both perform precision differential amplification, their gain networks, pin assignments, electrical limits, and calibration procedures must be compared before deciding whether a redesign is required.
Where can I buy the AD625CD?
Use the Request a Quote form on this page to inquire about AD625CD availability, minimum order quantity, current lead time, and the exact ceramic-DIP packaging required. Analog Devices marks the AD625 family as not recommended for new designs, so it is important to request the current lifecycle status before committing a production design. The quote request should include the AD625CD ordering code and the required delivery quantity.
What is the price of the AD625CD?
Current AD625CD pricing should be requested through the Request a Quote form on this page because commercial terms can change with quantity, packaging, availability, and market conditions. The manufacturer classifies the AD625 family as not recommended for new designs, so a quote request is the appropriate way to confirm whether an exact AD625CD is available for maintenance, repair, or previously approved production use.
What is the lead time for the AD625CD?
The current lead time for AD625CD should be confirmed through the Request a Quote form on this page. Lead time depends on exact orderable configuration, available inventory, and manufacturer allocation for this not-recommended-for-new-designs device. Include the required quantity and delivery schedule in the request so the supplier can confirm the appropriate source and production planning options.
Is the AD625CD in stock?
AD625CD inventory should be checked through the Request a Quote form on this page. Because Analog Devices identifies the AD625 family as not recommended for new designs, stock status may change more frequently than for an active family. Request confirmation for the exact AD625CD ordering code, quantity, date code, packaging, and delivery region before treating the component as available for a new build.
What are the key specifications of the AD625CD that engineers should know?
The key AD625CD specifications are programmable gains from 10 to 10,000, a 25 MHz gain-bandwidth product, 4 nV/√Hz input noise at 1 kHz, 0.02% maximum gain error, 0.001% maximum nonlinearity, and 25 µV maximum offset voltage. According to the Analog Devices AD625 datasheet, the part also has a maximum gain temperature coefficient of 5 ppm/°C and is offered in a 16-lead ceramic dual-in-line package.

エンジニアリング参考データ: AD625CD — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the AD625CD when an existing design requires a precision instrumentation amplifier with programmable gains from 10 to 10,000, low input noise, and a 16-CDIP footprint. Its 0.02% maximum gain error, 5 ppm/°C maximum gain temperature coefficient, 25 µV maximum offset voltage, and 25 MHz gain-bandwidth product make it suitable for load cells, strain gauges, current measurement, and laboratory instrumentation. AD625CN, AD625CNZ, and AD625CDZ are same-family ordering-code alternatives that retain the 16-CDIP architecture, but their exact qualification and lifecycle details must be checked before substitution. Do not select the AD624 as a drop-in replacement because it uses a different gain architecture. Because Analog Devices marks the AD625 family as not recommended for new designs, use the AD625CD primarily for maintenance, repair, and previously approved production designs; begin a new design with a currently recommended instrumentation-amplifier family.

代替品との比較

パラメータ この製品 AD625CN AD625CNZ AD625CDZ
Package 16-CDIP 16-CDIP 16-CDIP 16-CDIP
Brand Analog Devices Analog Devices Analog Devices Analog Devices
Product Type Programmable-gain instrumentation amplifier Programmable-gain instrumentation amplifier Programmable-gain instrumentation amplifier Programmable-gain instrumentation amplifier
Programmed Gain Range 10 to 10,000 10 to 10,000 10 to 10,000 10 to 10,000

主な差別化要因

  • Broad programmable gain range (vs AD624)
  • Precision gain calibration (vs AD625CN)
  • Low-noise input stage (vs AD625CDZ)

設計ノート

Do not select the gain without checking the resulting closed-loop bandwidth. The AD625CD has a 25 MHz gain-bandwidth product, so a high programmed gain reduces the bandwidth available for settling and signal fidelity. Use the manufacturer gain equations and bandwidth relationship for the selected configuration, then verify that the measurement bandwidth and settling interval remain adequate.

Route the differential input pair as a short, closely coupled pair and connect the gain-setting components close to the corresponding IC pins. This minimizes susceptibility to parasitic pickup and ground-current-induced errors. Keep high-current return paths away from the input and gain nodes, and use a quiet ground reference for the analog circuitry.

Check input common-mode voltage, output swing, supply voltage, and gain constraints before finalizing the bridge or sensor interface. The 25 µV maximum offset specification alone does not guarantee correct operation if the input leaves its valid common-mode region. Include sensor excitation tolerance, cable-induced offsets, and analog-to-converter input range in the worst-case signal-chain calculation.

Because the AD625 family is not recommended for new designs, preserve the original footprint and pin assignments if maintaining an existing board is the objective. Confirm the exact ordering code, ceramic-DIP package, temperature grade, and lifecycle status before placing a maintenance order. A family member with a similar description should not be installed without checking its complete pin and electrical descriptions.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The AD625 family is identified as not recommended for new designs. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations for the exact AD625CD ordering code were not identified.

データ検証日: 2026-11-18 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

ad625 datasheet AD625CD datasheet AD625CD pinout AD625CD datasheet pdf AD625CD application circuit AD625CD equivalent AD625CD replacement AD625CD cross reference AD625CD price AD625CD stock Analog Devices AD625CD AD625CD 16-CDIP footprint AD625CD programmable gain amplifier AD625CD vs AD624 AD625CD load cell amplifier

関連部品&用語

Analog Devices AD625CD AD625 AD625CN AD625CNZ AD625CDZ AD624 programmable-gain instrumentation amplifier instrumentation amplifier analog signal conditioner analog integrated circuit semiconductor 16-CDIP ceramic dual-in-line package through-hole package programmable gain gain-bandwidth product input noise density gain error offset voltage common-mode rejection load cell strain gauge industrial process monitoring
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示