AD625CD - Programmable Gain Amplifier | Analog Devices
MPN: AD625CD ✗ 停產AD625CD 概覽
An instrumentation amplifier is a differential analog signal-conditioning IC that combines input buffering, differential amplification, and gain-setting circuitry in one package. Its hierarchy includes instrumentation amplifier, analog signal conditioner, analog IC, and semiconductor. This category is particularly useful for amplifying small differential sensor signals while rejecting common-mode noise and voltage applied simultaneously to both inputs.
The AD625CD provides a maximum gain error of 0.02%, a maximum gain temperature coefficient of 5 ppm/°C, a maximum nonlinearity of 0.001%, and a maximum offset voltage of 25 µV. These characteristics support accurate measurement systems in which gain drift and signal-chain distortion directly affect result repeatability. The broad 10-to-10,000 gain range covers load-cell, strain-gauge, pressure-transducer, and laboratory measurement interfaces.
Its 25 MHz gain-bandwidth product provides useful bandwidth for low-frequency precision measurements and instrumentation. The specified 4 nV/√Hz input noise at 1 kHz helps preserve weak-signal information, while the low gain error and temperature coefficient support stable calibration over changing ambient conditions. The 16-CDIP package is suitable for conventional through-hole assembly where a mechanically robust ceramic package is preferred.
Typical uses include bridge-transducer amplification, precision current measurement, laboratory data acquisition, biomedical instrumentation, and industrial monitoring. In a bridge circuit, the AD625CD can amplify the small differential voltage generated by a strain gauge while rejecting ground-level common-mode voltage. In current sensing, its programmable gain allows the output range to be matched to the available analog-to-converter input range.
When designing the signal path, place the gain-setting network close to the device and observe the input common-mode and output-swing limits in the manufacturer datasheet. Check the required gain against the 25 MHz gain-bandwidth product so that the closed-loop bandwidth remains appropriate for the measurement bandwidth.
This page combines the AD625CD device characteristics, lifecycle status, application guidance, and design considerations into a practical engineering reference for evaluating this programmable instrumentation amplifier.
直接替換替代品,適用於 AD625CD — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD625CD (相同外形與佔位) — 差異在於 Package, Product Type.
AD625CN
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AD625CNZ
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AD625CD 最大額定值與電氣特性
| Product Type | Programmable-gain instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Programmed Gain Range | 10 to 10,000 |
| Maximum Gain Error | 0.02% |
| Maximum Gain Temperature Coefficient | 5 ppm/°C |
| Maximum Nonlinearity | 0.001% |
| Maximum Offset Voltage | 25 µV |
| Input Noise Density | 4 nV/√Hz at 1 kHz |
| Gain-Bandwidth Product | 25 MHz |
| 封裝 | 16-lead ceramic dual-in-line package (16-CDIP) |
| Terminal Count | 16 terminals |
| 安裝類型 | Through-hole |
| Temperature Grade | Industrial |
AD625CD 16-lead ceramic dual-in-line package (16-cdip) 腳位配置指南
AD625CD(16-lead ceramic dual-in-line package (16-cdip) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD625CD.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD625CD 適用於 6 應用s: Load-Cell Signal Conditioning, Strain-Gauge Measurement, Precision Current Sensing, Laboratory Data Acquisition, Biomedical Instrumentation, Industrial Process Monitoring.
Load-Cell Signal Conditioning
The AD625CD fits load-cell bridges whose output can range widely with excitation voltage, mechanical load, and bridge impedance. Its programmable gains from 10 to 10,000 allow the analog signal chain to be scaled without switching to unrelated amplifier families. The 4 nV/√Hz input noise at 1 kHz helps preserve small bridge differentials, while the 25 MHz gain-bandwidth product provides bandwidth beyond typical low-frequency weighing systems. Designers should verify the selected gain against the required measurement bandwidth and use the manufacturer input common-mode limits when setting the bridge excitation.
Strain-Gauge Measurement
A strain gauge connected to a resistive bridge produces a small differential voltage that the AD625CD can amplify for measurement or conversion. The maximum gain error of 0.02% and gain temperature coefficient of 5 ppm/°C help maintain calibration accuracy, while the 25 µV maximum offset voltage limits a significant source of low-level measurement error. The 10-to-10,000 programmable range supports different gauge sensitivities and mechanical test ranges. Keep the gain-setting components close to the amplifier and confirm that bridge excitation and common-mode voltage remain within the device operating limits.
Precision Current Sensing
The AD625CD can condition the differential output of a high-side or low-side current-sense amplifier when very small sensor voltages require accurate amplification. Its 4 nV/√Hz input noise at 1 kHz reduces the amplifier's contribution to the measurement floor, and programmable gain from 10 to 10,000 allows output range optimization for an analog-to-converter. The 25 MHz gain-bandwidth product supports bandwidth well above many power-monitoring applications. Final design work must include offset, common-mode, output-swing, and settling checks for the selected sensor and system gain.
Laboratory Data Acquisition
The AD625CD is useful as the analog front end of a laboratory measurement system that accepts programmable differential inputs at different sensitivities. Its gain range from 10 to 10,000 lets one instrument design cover multiple transducers without excessive fixed-gain stages. Low input noise of 4 nV/√Hz at 1 kHz, maximum nonlinearity of 0.001%, and maximum gain error of 0.02% support accurate capture of low-level signals. Engineers should calculate closed-loop bandwidth from the 25 MHz gain-bandwidth product and include settling time in the measurement acquisition sequence.
Biomedical Instrumentation
The AD625CD can amplify low-level differential signals from biomedical sensors when the system requires broad gain adjustment and low-noise input characteristics. The 4 nV/√Hz noise density at 1 kHz helps avoid masking small sensor outputs, while programmable gains from 10 to 10,000 support different electrode or transducer sensitivities. Medical-system design also requires careful isolation, protection, grounding, patient-safety review, and regulatory validation beyond the amplifier specifications. The manufacturer input limits and output-swing requirements must be checked in the final signal chain.
Industrial Process Monitoring
The AD625CD suits industrial process-monitoring systems that measure small differential signals from pressure, temperature, or resistive transducers. Its programmable gain allows one analog channel to cover different sensor ranges, while 0.02% maximum gain error and 5 ppm/°C maximum gain temperature coefficient support repeatable measurements. The 25 MHz gain-bandwidth product allows useful bandwidth margin for many process-control signals. For long cable runs and grounded sensors, verify common-mode range, grounding strategy, filtering, and surge protection before applying power.
工程參考資料,適用於 AD625CD — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD625CN | AD625CNZ | AD625CDZ |
|---|---|---|---|---|
| Package | 16-CDIP | 16-CDIP | 16-CDIP | 16-CDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier |
| Programmed Gain Range | 10 to 10,000 | 10 to 10,000 | 10 to 10,000 | 10 to 10,000 |
主要差異化特點
- Broad programmable gain range (對比AD624)
- Precision gain calibration (對比AD625CN)
- Low-noise input stage (對比AD625CDZ)
設計說明
Do not select the gain without checking the resulting closed-loop bandwidth. The AD625CD has a 25 MHz gain-bandwidth product, so a high programmed gain reduces the bandwidth available for settling and signal fidelity. Use the manufacturer gain equations and bandwidth relationship for the selected configuration, then verify that the measurement bandwidth and settling interval remain adequate.
Route the differential input pair as a short, closely coupled pair and connect the gain-setting components close to the corresponding IC pins. This minimizes susceptibility to parasitic pickup and ground-current-induced errors. Keep high-current return paths away from the input and gain nodes, and use a quiet ground reference for the analog circuitry.
Check input common-mode voltage, output swing, supply voltage, and gain constraints before finalizing the bridge or sensor interface. The 25 µV maximum offset specification alone does not guarantee correct operation if the input leaves its valid common-mode region. Include sensor excitation tolerance, cable-induced offsets, and analog-to-converter input range in the worst-case signal-chain calculation.
Because the AD625 family is not recommended for new designs, preserve the original footprint and pin assignments if maintaining an existing board is the objective. Confirm the exact ordering code, ceramic-DIP package, temperature grade, and lifecycle status before placing a maintenance order. A family member with a similar description should not be installed without checking its complete pin and electrical descriptions.
合規資訊
The AD625 family is identified as not recommended for new designs. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations for the exact AD625CD ordering code were not identified.