AD625KNZ - 25MHz Instrumentation Amplifier | Analog Devices
Référence : AD625KNZ ✓ ActifAD625KNZ Présentation
An instrumentation amplifier is a differential amplifier optimized for amplifying small sensor signals while rejecting large common-mode voltages. In the signal-chain hierarchy, the AD625 belongs to the instrumentation-amplifier class of amplifier ICs, sitting between general-purpose operational amplifiers and application-specific measurement front ends. Its internal differential core simplifies the transition from a bridge, strain gauge, or thermocouple to a downstream ADC.
The AD625 supports precision signal conditioning through a user-selectable gain network and is suited to applications that require nonstandard gain values not easily obtained with common resistor-programmed amplifiers. Its 50 uV offset specification supports accurate low-level measurements, while the 5 V/us slew rate enables higher-amplitude output transitions without requiring a substantially faster amplifier.
The AD625 operates from dual supplies of +/-6 V through +/-18 V. Differential inputs can therefore accept substantial signal swing relative to the output reference, which is valuable when transducers produce bipolar outputs centered around ground. The 25 MHz gain-bandwidth product defines the high-frequency behavior of the amplifier, while its internal architecture determines the usable bandwidth at each closed-loop gain.
Typical uses include bridge and strain-gauge conditioning, biomedical instrumentation, current-loop receivers, laboratory measurement systems, and high-impedance sensor interfaces. The 16-pin PDIP package is suitable for through-hole assembly and prototypes, and the AD625 family provides related package and temperature options for production sourcing.
When laying out a circuit, keep the differential input traces short, symmetrical, and away from high-current switching paths. Connect the gain-setting network close to the amplifier, use a stable reference for output-referenced measurements, and follow the manufacturer pinout and reference-circuit guidance before assigning PCB tracks.
This page combines manufacturer specifications, package information, cross-reference findings, comparison parameters, and application-specific design guidance to support component selection and PCB implementation for AD625KNZ-based precision measurement circuits.
Alternatives de remplacement direct pour AD625KNZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD625KNZ (même facteur de forme et même empreinte) — différant par Gain Configuration, Package, Common-Mode Rejection Ratio, Product Type, RoHS Status.
AD625ADZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD625BD/+
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD625SD
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD625KNZ Valeurs maximales et caractéristiques électriques
| Device Type | Single-channel precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Input Offset Voltage | 50 uV |
| Slew Rate | 5 V/us |
| Gain-Bandwidth Product | 25 MHz |
| Low-Loss 3 dB Bandwidth | 650 kHz |
| Supply Voltage Range | +/-6 V to +/-18 V |
| Boîtier | 16-pin PDIP |
| Type de montage | Through-hole |
| Gain Configuration | User-selectable |
| Common-Mode Rejection Ratio | 75 dB |
Guide de configuration des broches du AD625KNZ 16-pin pdip
Configuration des broches du AD625KNZ (boîtier 16-pin pdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD625KNZ.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD625KNZ convient pour 6 applications: Strain-Gauge and Load-Cell Bridge Conditioning, Biomedical Electrode and Physiological Signal Acquisition, Precision Current-Loop Receiver, Laboratory Instrumentation and Measurement Systems, Industrial Sensor and Transducer Interface, Audio and Low-Level AC Measurement.
Strain-Gauge and Load-Cell Bridge Conditioning
The AD625KNZ suits low-level bridge measurements because its differential input stage rejects the larger excitation-related common-mode voltage while preserving the small bridge imbalance. Its 50 uV input offset and 75 dB listed common-mode rejection support accurate conditioning of resistive strain gauges, load cells, and pressure transducers. The 5 V/us slew rate allows the output to follow dynamic mechanical events without the amplifier becoming the limiting stage. Set the gain from the specified sensitivity of the sensor, maintain a low-noise excitation reference, and keep the two input routes symmetrical to avoid degrading balance.
Recommandé
Biomedical Electrode and Physiological Signal Acquisition
The AD625KNZ is appropriate for high-impedance physiological electrode front ends where the wanted bioelectric signal is small and common-mode interference can be much larger. Its instrumentation-amplifier topology provides differential gain in one package, reducing the number of matched discrete stages and helping preserve signal integrity. The 50 uV offset specification and +/-6 V to +/-18 V dual supply range support accurate conditioning around a zero-volt signal center. Right-drive and guarding techniques should be applied according to the manufacturer guidance, with strict attention to patient isolation requirements outside the amplifier itself.
Recommandé
Precision Current-Loop Receiver
The AD625KNZ can condition low-level current-loop transmitter signals when the application requires a high input impedance and strong rejection of voltage present on both sensor lines. Its differential input arrangement avoids responding to common supply and return disturbances that could otherwise obscure the measurement. The 25 MHz gain-bandwidth product and 5 V/us slew rate provide speed for sensor dynamics, while the 650 kHz listed bandwidth is generally more important for determining usable signal bandwidth. Confirm the complete input common-mode range and output swing in the manufacturer datasheet before selecting external protection components.
Recommandé
Laboratory Instrumentation and Measurement Systems
The AD625KNZ is well matched to laboratory instruments that combine a selectable gain with differential sensor inputs, such as analyzer front ends and programmable measurement fixtures. A single precision instrumentation amplifier simplifies the signal path compared with a multi-op-amp implementation and provides consistent common-mode behavior across multiple gain settings. Its 50 uV offset and 5 V/us slew rate support accurate low-level measurements while retaining useful response speed. For laboratory systems, stable reference connections, calibrated gain resistors, guarded analog grounds, and calibrated excitation are as important as the amplifier itself.
Recommandé
Industrial Sensor and Transducer Interface
The AD625KNZ provides a practical differential input stage for industrial pressure, position, and level transducers that operate with substantial common-mode voltage. The 75 dB listed common-mode rejection helps separate the useful sensor output from system-level disturbances, while the +/-6 V to +/-18 V supply range accommodates conventional bipolar analog rails. The 25 MHz gain-bandwidth product leaves headroom above the listed 650 kHz bandwidth, allowing the closed-loop gain to be selected according to the transducer response. Use shielding or differential routing when the transducer leads are long, and place protection components where they will not add significant leakage or capacitance.
Recommandé
Audio and Low-Level AC Measurement
The AD625KNZ can amplify low-level differential AC signals when the circuit requires controlled gain and strong rejection of common-mode pickup. Its 5 V/us slew rate provides sufficient headroom for many audio-frequency and instrumentation-band signals, while the user-selectable gain supports adaptation to different transducer sensitivities. Common-mode rejection protects the wanted channel from shared cable noise, but the final signal quality still depends on shielding, input capacitance, source impedance matching, and the gain-setting resistor network. Verify the frequency response at the intended gain rather than relying only on the 25 MHz gain-bandwidth product.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD625KNZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD625ADZ | AD625BD/+ | AD625SD |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-Pin PDIP | 16-Pin Sealed Ceramic DIP | 16-Pin PDIP | 16-Pin PDIP |
| Device Type | Precision Instrumentation Amplifier | Precision Instrumentation Amplifier | Precision Instrumentation Amplifier | Precision Instrumentation Amplifier |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel |
Principaux différenciateurs
- Higher listed common-mode rejection than the AD625SD (vs AD625SD)
- Sealed-package option with matching listed speed (vs AD625ADZ)
- AD625-family function in a plastic PDIP configuration (vs AD625BD/+)
Notes de conception
Route the two differential inputs as a compact, symmetric pair and minimize their enclosed area to reduce pickup from surrounding currents. Place input protection and filtering components directly at the connector or sensor interface, while keeping the gain-setting network close to the amplifier. Provide a quiet analog return plane and route high-current outputs and switching nodes separately from the input pair.
Do not select bandwidth from the 25 MHz gain-bandwidth product alone. The listed 650 kHz low-loss bandwidth is more useful for evaluating a closed-loop configuration, and usable bandwidth decreases as gain rises. Verify the gain equation, maximum input common-mode voltage, and output swing using the manufacturer datasheet before committing resistor values and downstream ADC ranges.
Use matched, low-noise resistors in the gain network and account for source impedance balance between the two inputs. Unequal source impedances convert common-mode voltage into differential error and reduce the effective rejection ratio. For long sensor cables, use shield-driven or guarded input techniques where applicable and verify leakage from ESD or overvoltage protection against the measurement accuracy required by the application.
Bypass the supply pins close to the package and keep analog return current out of the signal-reference path. The +/-6 V to +/-18 V operating range allows conventional bipolar rails, but the exact quiescent current, allowable supply imbalance, and decoupling recommendations must be taken from the datasheet. Place a dedicated low-impedance return for each supply so output-current transients do not modulate the reference node.