AD625KNZ - 25MHz Instrumentation Amplifier | Analog Devices
MPN: AD625KNZ ✓ 啟用中AD625KNZ 概覽
An instrumentation amplifier is a differential amplifier optimized for amplifying small sensor signals while rejecting large common-mode voltages. In the signal-chain hierarchy, the AD625 belongs to the instrumentation-amplifier class of amplifier ICs, sitting between general-purpose operational amplifiers and application-specific measurement front ends. Its internal differential core simplifies the transition from a bridge, strain gauge, or thermocouple to a downstream ADC.
The AD625 supports precision signal conditioning through a user-selectable gain network and is suited to applications that require nonstandard gain values not easily obtained with common resistor-programmed amplifiers. Its 50 uV offset specification supports accurate low-level measurements, while the 5 V/us slew rate enables higher-amplitude output transitions without requiring a substantially faster amplifier.
The AD625 operates from dual supplies of +/-6 V through +/-18 V. Differential inputs can therefore accept substantial signal swing relative to the output reference, which is valuable when transducers produce bipolar outputs centered around ground. The 25 MHz gain-bandwidth product defines the high-frequency behavior of the amplifier, while its internal architecture determines the usable bandwidth at each closed-loop gain.
Typical uses include bridge and strain-gauge conditioning, biomedical instrumentation, current-loop receivers, laboratory measurement systems, and high-impedance sensor interfaces. The 16-pin PDIP package is suitable for through-hole assembly and prototypes, and the AD625 family provides related package and temperature options for production sourcing.
When laying out a circuit, keep the differential input traces short, symmetrical, and away from high-current switching paths. Connect the gain-setting network close to the amplifier, use a stable reference for output-referenced measurements, and follow the manufacturer pinout and reference-circuit guidance before assigning PCB tracks.
This page combines manufacturer specifications, package information, cross-reference findings, comparison parameters, and application-specific design guidance to support component selection and PCB implementation for AD625KNZ-based precision measurement circuits.
直接替換替代品,適用於 AD625KNZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD625KNZ (相同外形與佔位) — 差異在於 Gain Configuration, Package, Common-Mode Rejection Ratio, Product Type, RoHS Status.
AD625ADZ
✅ 直接替換聯絡詢價
查看資料表 →AD625KNZ 最大額定值與電氣特性
| Device Type | Single-channel precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Input Offset Voltage | 50 uV |
| Slew Rate | 5 V/us |
| Gain-Bandwidth Product | 25 MHz |
| Low-Loss 3 dB Bandwidth | 650 kHz |
| Supply Voltage Range | +/-6 V to +/-18 V |
| 封裝 | 16-pin PDIP |
| 安裝類型 | Through-hole |
| Gain Configuration | User-selectable |
| Common-Mode Rejection Ratio | 75 dB |
AD625KNZ 16-pin pdip 腳位配置指南
AD625KNZ(16-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD625KNZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD625KNZ 適用於 6 應用s: Strain-Gauge and Load-Cell Bridge Conditioning, Biomedical Electrode and Physiological Signal Acquisition, Precision Current-Loop Receiver, Laboratory Instrumentation and Measurement Systems, Industrial Sensor and Transducer Interface, Audio and Low-Level AC Measurement.
Strain-Gauge and Load-Cell Bridge Conditioning
The AD625KNZ suits low-level bridge measurements because its differential input stage rejects the larger excitation-related common-mode voltage while preserving the small bridge imbalance. Its 50 uV input offset and 75 dB listed common-mode rejection support accurate conditioning of resistive strain gauges, load cells, and pressure transducers. The 5 V/us slew rate allows the output to follow dynamic mechanical events without the amplifier becoming the limiting stage. Set the gain from the specified sensitivity of the sensor, maintain a low-noise excitation reference, and keep the two input routes symmetrical to avoid degrading balance.
推薦
Biomedical Electrode and Physiological Signal Acquisition
The AD625KNZ is appropriate for high-impedance physiological electrode front ends where the wanted bioelectric signal is small and common-mode interference can be much larger. Its instrumentation-amplifier topology provides differential gain in one package, reducing the number of matched discrete stages and helping preserve signal integrity. The 50 uV offset specification and +/-6 V to +/-18 V dual supply range support accurate conditioning around a zero-volt signal center. Right-drive and guarding techniques should be applied according to the manufacturer guidance, with strict attention to patient isolation requirements outside the amplifier itself.
推薦
Precision Current-Loop Receiver
The AD625KNZ can condition low-level current-loop transmitter signals when the application requires a high input impedance and strong rejection of voltage present on both sensor lines. Its differential input arrangement avoids responding to common supply and return disturbances that could otherwise obscure the measurement. The 25 MHz gain-bandwidth product and 5 V/us slew rate provide speed for sensor dynamics, while the 650 kHz listed bandwidth is generally more important for determining usable signal bandwidth. Confirm the complete input common-mode range and output swing in the manufacturer datasheet before selecting external protection components.
推薦
Laboratory Instrumentation and Measurement Systems
The AD625KNZ is well matched to laboratory instruments that combine a selectable gain with differential sensor inputs, such as analyzer front ends and programmable measurement fixtures. A single precision instrumentation amplifier simplifies the signal path compared with a multi-op-amp implementation and provides consistent common-mode behavior across multiple gain settings. Its 50 uV offset and 5 V/us slew rate support accurate low-level measurements while retaining useful response speed. For laboratory systems, stable reference connections, calibrated gain resistors, guarded analog grounds, and calibrated excitation are as important as the amplifier itself.
推薦
Industrial Sensor and Transducer Interface
The AD625KNZ provides a practical differential input stage for industrial pressure, position, and level transducers that operate with substantial common-mode voltage. The 75 dB listed common-mode rejection helps separate the useful sensor output from system-level disturbances, while the +/-6 V to +/-18 V supply range accommodates conventional bipolar analog rails. The 25 MHz gain-bandwidth product leaves headroom above the listed 650 kHz bandwidth, allowing the closed-loop gain to be selected according to the transducer response. Use shielding or differential routing when the transducer leads are long, and place protection components where they will not add significant leakage or capacitance.
推薦
Audio and Low-Level AC Measurement
The AD625KNZ can amplify low-level differential AC signals when the circuit requires controlled gain and strong rejection of common-mode pickup. Its 5 V/us slew rate provides sufficient headroom for many audio-frequency and instrumentation-band signals, while the user-selectable gain supports adaptation to different transducer sensitivities. Common-mode rejection protects the wanted channel from shared cable noise, but the final signal quality still depends on shielding, input capacitance, source impedance matching, and the gain-setting resistor network. Verify the frequency response at the intended gain rather than relying only on the 25 MHz gain-bandwidth product.
推薦
推薦產品摘要
工程參考資料,適用於 AD625KNZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD625ADZ | AD625BD/+ | AD625SD |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-Pin PDIP | 16-Pin Sealed Ceramic DIP | 16-Pin PDIP | 16-Pin PDIP |
| Device Type | Precision Instrumentation Amplifier | Precision Instrumentation Amplifier | Precision Instrumentation Amplifier | Precision Instrumentation Amplifier |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel |
主要差異化特點
- Higher listed common-mode rejection than the AD625SD (對比AD625SD)
- Sealed-package option with matching listed speed (對比AD625ADZ)
- AD625-family function in a plastic PDIP configuration (對比AD625BD/+)
設計說明
Route the two differential inputs as a compact, symmetric pair and minimize their enclosed area to reduce pickup from surrounding currents. Place input protection and filtering components directly at the connector or sensor interface, while keeping the gain-setting network close to the amplifier. Provide a quiet analog return plane and route high-current outputs and switching nodes separately from the input pair.
Do not select bandwidth from the 25 MHz gain-bandwidth product alone. The listed 650 kHz low-loss bandwidth is more useful for evaluating a closed-loop configuration, and usable bandwidth decreases as gain rises. Verify the gain equation, maximum input common-mode voltage, and output swing using the manufacturer datasheet before committing resistor values and downstream ADC ranges.
Use matched, low-noise resistors in the gain network and account for source impedance balance between the two inputs. Unequal source impedances convert common-mode voltage into differential error and reduce the effective rejection ratio. For long sensor cables, use shield-driven or guarded input techniques where applicable and verify leakage from ESD or overvoltage protection against the measurement accuracy required by the application.
Bypass the supply pins close to the package and keep analog return current out of the signal-reference path. The +/-6 V to +/-18 V operating range allows conventional bipolar rails, but the exact quiescent current, allowable supply imbalance, and decoupling recommendations must be taken from the datasheet. Place a dedicated low-impedance return for each supply so output-current transients do not modulate the reference node.
合規資訊