AS7050-BWLM - Biosignal AFE PPG/ECG/GSR, I2C | ams OSRAM
Référence : AS7050-BWLM ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $0 | $0,00 |
| 10 | $0 | $0,00 |
| 100 | $0 | $0,00 |
| 500 | $0 | $0,00 |
| 1 000 | $0 | $0,00 |
AS7050-BWLM Présentation
An analog front end is the signal-chain block that sits between raw physiological sensors and a digital processor. In wearables and medical monitoring devices, the AFE conditions, amplifies, filters, and digitizes tiny biosignals - microvolt-level ECG potentials or nanoamp-scale photodiode currents from PPG - before they reach the microcontroller. The AFE therefore sits within the biosensor hierarchy between the optical/electrode sensor elements and the system's digital signal processing stage.
Key differentiating features of the AS7050 include multi-modal biosignal support: PPG is the most used heart-rate monitoring (HRM) method, measuring pulse rate by sampling light modulated by blood vessels that expand and contract as blood pulses through them; ECG captures the heart's electrical activity; and GSR tracks skin conductance for stress and hydration metrics. Integration of these three modalities in one device lets designers build multi-parameter health wearables with a single AFE. The I2C output simplifies host integration, and the WLP package supports the miniature form factors demanded by smartwatches, fitness bands, and earbuds.
Per the ams AG datasheet (19 pages, File Size 1,016 Kbytes), the AS7050-BWLM is described as the next-generation vital sign sensor platform. Its architecture combines low-noise analog readout channels for optical and electrode inputs with flexible LED drive capability for PPG, allowing optimized signal-to-noise ratio at low power - critical for battery-operated continuous monitoring.
Typical applications include wrist-worn heart-rate and SpO2 monitors, chest-strap and patch ECG recorders, stress-tracking wearables using GSR, and clinical-grade remote patient monitoring peripherals. Any design needing PPG, ECG, and GSR from a single small-footprint front end is a natural fit.
A key design consideration: biosignal quality depends heavily on PCB layout discipline - keep the high-impedance ECG electrode inputs short and guarded, and isolate optical channels from digital switching noise; consult the ams OSRAM reference designs for wearable optical placements.
This page synthesizes distributor availability from DigiKey, Mouser, and Octopart, datasheet sourcing links, and drop-in alternative analysis not consolidated in the manufacturer datasheet alone.
Alternatives de remplacement direct pour AS7050-BWLM — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AS7050-BWLM (même facteur de forme et même empreinte) — différant par Package, External Electrode Support, Product Type, RoHS Status.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
AS7050-BWLM_REV.C
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AS7050-BWLM Valeurs maximales et caractéristiques électriques
| Product Type | Biosignal Sensor Analog Front End (AFE) |
| Supported Biosignals | PPG, ECG, GSR |
| Digital Interface | I2C |
| Boîtier | WLP (wafer-level package), lead-free |
| Packaging Option | Tape & Reel |
| Manufacturer | ams OSRAM |
| Application | Vital Sign Monitoring / Biomonitoring |
| Datasheet Revision | REV.C |
| Type de montage | Surface Mount |
| Statut RoHS | Lead-free (LF) ordering option indicated |
Guide de configuration des broches du AS7050-BWLM wlp (wafer-level package), lead-free
Configuration des broches du AS7050-BWLM (boîtier wlp (wafer-level package), lead-free). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour AS7050-BWLM.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AS7050-BWLM convient pour 6 applications: Wrist-Worn Heart Rate Monitoring, ECG Patch and Chest Strap Recorders, Stress and GSR Monitoring Wearables, Remote Patient Monitoring Peripherals, True Wireless Earbud Health Sensing, Fitness Band Multi-Vital Tracking.
Wrist-Worn Heart Rate Monitoring
The AS7050-BWLM fits wrist-worn HRM wearables because PPG is its most developed measurement mode: PPG works by sampling light modulated by blood vessels that expand and contract as blood pulses through them, and the AFE provides the synchronized LED drive and low-noise photodiode readout this optical method requires. Placed under a green/IR LED and photodiode stack on the watch backplate, the AS7050 digitizes the pulse waveform and streams it over I2C to the wearable MCU. Because the AFE integrates the analog chain in a WLP, the optical module stays compact enough for slim watch enclosures, and motion-artifact handling is done in the host DSP using the sampled raw data. Designers should follow the ams OSRAM optical placement reference designs to minimize ambient-light crosstalk and achieve reliable readings across skin tones and exercise conditions, where signal amplitudes can drop dramatically compared to resting measurements.
Recommandé
ECG Patch and Chest Strap Recorders
For ECG capture in chest straps and adhesive patches, the AS7050-BWLM provides the dedicated ECG analog front-end channel that amplifies and digitizes the microvolt-level cardiac potentials picked up by skin electrodes. The biosignal is acquired through the AFE's high-impedance electrode inputs, filtered and converted on-chip, then transferred via I2C to the system microcontroller for R-peak detection and heart-rate variability analysis. Because ECG signals are orders of magnitude smaller than PPG photodiode currents, PCB layout is the dominant quality factor: keep electrode traces short, guard the high-impedance nodes, and route the I2C bus away from the electrode path. In battery-powered patches, the WLP's small footprint lets the entire electronics sit within a few square centimeters behind the electrode. Continuous-monitoring products benefit from combining ECG with PPG for pulse-transit-time based blood pressure trend estimation in advanced vital sign patches.
Recommandé
Stress and GSR Monitoring Wearables
GSR (galvanic skin resistance) measurement for stress tracking is a native modality of the AS7050-BWLM, making it suitable for wearables that correlate electrodermal activity with heart rate and sleep stages. The AFE drives the skin-contact electrodes and measures the resulting conductance changes that reflect sympathetic nervous system activity; the digitized GSR data is streamed over I2C alongside PPG-derived heart rate, giving algorithm developers two complementary physiological signals from one IC. In wristbands and rings, the GSR electrodes typically double as the wearable's housing contacts, so the WLP package's small size helps place the AFE close to the electrode connection point to minimize parasitic leakage. Designers should note that GSR accuracy depends on electrode-skin contact quality and humidity compensation, which is handled in firmware using the AFE's sampled data. This multi-signal integration is why the AS7050 is described by ams OSRAM as a next-generation vital sign sensor platform.
Recommandé
Remote Patient Monitoring Peripherals
Clinical and telehealth remote patient monitoring devices use the AS7050-BWLM to capture multi-parameter vitals - pulse rate via PPG, cardiac electrical activity via ECG, and stress indicators via GSR - in a single compact front end, then relay the I2C data to a Bluetooth or cellular module for cloud transmission. The benefit for home-care peripherals is BOM consolidation: one biosignal AFE covers three measurement types that would otherwise each need dedicated signal-conditioning circuitry, shrinking the PCB and simplifying regulatory testing of the analog chain. The WLP package supports disposable or rechargeable patch form factors that patients wear for days. Design considerations include noise isolation between the electrode inputs and the wireless module's switching circuitry, and duty-cycling the AFE between measurement windows to extend battery life. According to the ams OSRAM product page, the AS7050 is explicitly positioned for medical and health sensing applications of exactly this type.
Recommandé
True Wireless Earbud Health Sensing
In-ear PPG heart-rate sensing in true wireless earbuds is a strong fit for the AS7050-BWLM because the WLP's tiny footprint and the integration of LED drive, photodiode readout, and digitization on one die fit the severe space and power budget inside an earbud shell. The AFE samples the in-ear photoplethysmogram - light modulated by blood flow in ear tissue - and streams samples over I2C to the earbud SoC, which fuses them with IMU data for motion-robust heart rate. Power efficiency of the analog chain matters more here than in wrist wearables since the battery is tens of milliamp-hours; duty-cycled PPG windows triggered by motion detection keep average consumption low. Layout guidance is to keep the optical sensor pair immediately adjacent to the AFE's PPG inputs and to shield the I2C bus from the RF antenna of the earbud's radio. Follow ams OSRAM reference designs for in-ear optical port sealing against ambient light leakage.
Recommandé
Fitness Band Multi-Vital Tracking
Fitness bands that track heart rate, workout intensity, and stress around the clock benefit from the AS7050-BWLM's three-mode capability: continuous PPG for heart rate, periodic ECG for rhythm spot-checks when the user touches the band electrodes, and GSR for stress and hydration trend detection. Running all three from one AFE reduces the sensor bill of materials versus discrete solutions and simplifies firmware scheduling of measurement windows through the I2C register interface. The WLP lead-free package withstands the reflow profiles of densely populated wearable PCBs shared with the Bluetooth SoC and battery charger. Battery life optimization is the main engineering task: alternate high-rate PPG during workouts with low-duty GSR sampling at rest, using the AFE's configurable sample rates. For mass production, the tape and reel packaging supports high-volume SMT assembly. Verify final electrode and optical stack dimensions against the ams OSRAM mechanical reference designs before tooling the enclosure.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AS7050-BWLM — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AS7050-BWLM_REV.C |
|---|---|---|
| Package | WLP (lead-free) | WLP (lead-free) - same |
| Brand | ams OSRAM | ams OSRAM |
| Supported Biosignals | PPG, ECG, GSR | PPG, ECG, GSR |
| Digital Interface | I2C | I2C |
| Application Domain | Vital Sign Monitoring / Biomonitoring | Vital Sign Monitoring / Biomonitoring |
| Lifecycle Status | Active | Active (current ordering code) |
| Functional Cross-Brand Alternatives | None (this is the reference part) | None required - same device |
Principaux différenciateurs
- Three biosignal modalities in one AFE (vs AS7050-BWLM_REV.C (single-channel competitor AFEs))
- WLP lead-free package for miniaturized wearables (vs Functional alternatives with larger QFN/leads packages)
- I2C host integration (vs AFE solutions with proprietary or SPI-only interfaces)
Notes de conception
The ECG electrode inputs of the AS7050-BWLM are high-impedance nodes that capture microvolt-level cardiac signals. Keep electrode traces as short as practically possible, guard them with driven shield traces where the layout allows, and place the DC-blocking/ESD network directly at the connector. Route the I2C bus and any switching regulator components away from the electrode path - even small capacitive coupling from a switching node can inject artifacts that dominate the ECG waveform. Validate signal quality with the wearer stationary and in motion before freezing the layout.
For the PPG optical channel, the photodiode-to-AFE trace length directly sets susceptibility to ambient light pickup and crosstalk. Place the AS7050-BWLM as close as the mechanical stack allows to the optical window, keep the photodiode anode trace short and guarded, and use a solid ground plane beneath the analog section. Shield the optical cavity from LED side-scatter with an opaque spacer, following the ams OSRAM wearable reference designs. Do not run antenna or RF feed lines under the analog region of a wearable PCB.
Biosignal AFEs in wearables live on battery budgets measured in milliamp-hours, so power-plan the measurement schedule: use the AFE's configurable sample windows to duty-cycle PPG bursts (highest current, LED-driven) while sampling GSR or ECG at lower rates. Decouple the AFE supply with a ceramic capacitor placed at the ball, and prefer a low-noise LDO over a buck converter for the analog rail if a clean rail exists at acceptable efficiency; if a buck is unavoidable, synchronize its switching away from the PPG sampling instants in firmware.
Informations de conformité
Ordering code AS7050-BWLM_REV.C WLP LF T&R explicitly denotes a Lead-Free (LF) option; Mouser lists ams OSRAM parts in this family under RoHS-compliant filters. REACH and halogen-free status not stated in provided data - confirm via ams OSRAM material declarations.