AS7050-BWLM Overview

The ams OSRAM AS7050-BWLM is a biosignal sensor analog front end (AFE) for vital sign monitoring, supporting photoplethysmogram (PPG), electrocardiogram (ECG), and galvanic skin resistance (GSR) measurement with an I2C digital output interface, housed in a wafer-level package (WLP, lead-free, tape and reel).

An analog front end is the signal-chain block that sits between raw physiological sensors and a digital processor. In wearables and medical monitoring devices, the AFE conditions, amplifies, filters, and digitizes tiny biosignals - microvolt-level ECG potentials or nanoamp-scale photodiode currents from PPG - before they reach the microcontroller. The AFE therefore sits within the biosensor hierarchy between the optical/electrode sensor elements and the system's digital signal processing stage.

Key differentiating features of the AS7050 include multi-modal biosignal support: PPG is the most used heart-rate monitoring (HRM) method, measuring pulse rate by sampling light modulated by blood vessels that expand and contract as blood pulses through them; ECG captures the heart's electrical activity; and GSR tracks skin conductance for stress and hydration metrics. Integration of these three modalities in one device lets designers build multi-parameter health wearables with a single AFE. The I2C output simplifies host integration, and the WLP package supports the miniature form factors demanded by smartwatches, fitness bands, and earbuds.

Per the ams AG datasheet (19 pages, File Size 1,016 Kbytes), the AS7050-BWLM is described as the next-generation vital sign sensor platform. Its architecture combines low-noise analog readout channels for optical and electrode inputs with flexible LED drive capability for PPG, allowing optimized signal-to-noise ratio at low power - critical for battery-operated continuous monitoring.

Typical applications include wrist-worn heart-rate and SpO2 monitors, chest-strap and patch ECG recorders, stress-tracking wearables using GSR, and clinical-grade remote patient monitoring peripherals. Any design needing PPG, ECG, and GSR from a single small-footprint front end is a natural fit.

A key design consideration: biosignal quality depends heavily on PCB layout discipline - keep the high-impedance ECG electrode inputs short and guarded, and isolate optical channels from digital switching noise; consult the ams OSRAM reference designs for wearable optical placements.

This page synthesizes distributor availability from DigiKey, Mouser, and Octopart, datasheet sourcing links, and drop-in alternative analysis not consolidated in the manufacturer datasheet alone.

Drop-in alternatives for AS7050-BWLM — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with AS7050-BWLM (same form factor and footprint) — differing in Package, External Electrode Support, Product Type, RoHS Status.

ams OSRAM
Package: WLCSP (Wafer-Level Chip-Scale Package)
External Electrode Support: Yes (ECG/GSR)
Compare with AS7050-BWLM →
ams OSRAM
Package: WLP
External Electrode Support: Yes
Product Type: Biosignal Sensor Analog Frontend (AFE)
Compare with AS7050-BWLM →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

AS7050-BWLM_REV.C

✅ Drop-In
📦 WLP
revision-C ordering code of the same AS7050-BWLM silicon and package; identical PPG/ECG/GSR function and I2C interface (0% parametric difference)

📋 Reference alternative (not in catalog)

AS7050-BWLM Maximum Ratings & Electrical Characteristics

Product Type Biosignal Sensor Analog Front End (AFE)
Supported Biosignals PPG, ECG, GSR
Digital Interface I2C
Package WLP (wafer-level package), lead-free
Packaging Option Tape & Reel
Manufacturer ams OSRAM
Application Vital Sign Monitoring / Biomonitoring
Datasheet Revision REV.C
Mounting Type Surface Mount
RoHS Status Lead-free (LF) ordering option indicated

AS7050-BWLM wlp (wafer-level package), lead-free Pin Configuration Guide

Pin configuration for AS7050-BWLM (wlp (wafer-level package), lead-free package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.

wlp (wafer-level package), lead-free package pinout diagram for AS7050-BWLM

No detailed pinout data available for AS7050-BWLM.

Refer to the datasheet for full pin configuration.

Typical Applications

AS7050-BWLM is suitable for 6 applications: Wrist-Worn Heart Rate Monitoring, ECG Patch and Chest Strap Recorders, Stress and GSR Monitoring Wearables, Remote Patient Monitoring Peripherals, True Wireless Earbud Health Sensing, Fitness Band Multi-Vital Tracking.

📱

Wrist-Worn Heart Rate Monitoring

The AS7050-BWLM fits wrist-worn HRM wearables because PPG is its most developed measurement mode: PPG works by sampling light modulated by blood vessels that expand and contract as blood pulses through them, and the AFE provides the synchronized LED drive and low-noise photodiode readout this optical method requires. Placed under a green/IR LED and photodiode stack on the watch backplate, the AS7050 digitizes the pulse waveform and streams it over I2C to the wearable MCU. Because the AFE integrates the analog chain in a WLP, the optical module stays compact enough for slim watch enclosures, and motion-artifact handling is done in the host DSP using the sampled raw data. Designers should follow the ams OSRAM optical placement reference designs to minimize ambient-light crosstalk and achieve reliable readings across skin tones and exercise conditions, where signal amplitudes can drop dramatically compared to resting measurements.

💊

ECG Patch and Chest Strap Recorders

For ECG capture in chest straps and adhesive patches, the AS7050-BWLM provides the dedicated ECG analog front-end channel that amplifies and digitizes the microvolt-level cardiac potentials picked up by skin electrodes. The biosignal is acquired through the AFE's high-impedance electrode inputs, filtered and converted on-chip, then transferred via I2C to the system microcontroller for R-peak detection and heart-rate variability analysis. Because ECG signals are orders of magnitude smaller than PPG photodiode currents, PCB layout is the dominant quality factor: keep electrode traces short, guard the high-impedance nodes, and route the I2C bus away from the electrode path. In battery-powered patches, the WLP's small footprint lets the entire electronics sit within a few square centimeters behind the electrode. Continuous-monitoring products benefit from combining ECG with PPG for pulse-transit-time based blood pressure trend estimation in advanced vital sign patches.

🧩

Stress and GSR Monitoring Wearables

GSR (galvanic skin resistance) measurement for stress tracking is a native modality of the AS7050-BWLM, making it suitable for wearables that correlate electrodermal activity with heart rate and sleep stages. The AFE drives the skin-contact electrodes and measures the resulting conductance changes that reflect sympathetic nervous system activity; the digitized GSR data is streamed over I2C alongside PPG-derived heart rate, giving algorithm developers two complementary physiological signals from one IC. In wristbands and rings, the GSR electrodes typically double as the wearable's housing contacts, so the WLP package's small size helps place the AFE close to the electrode connection point to minimize parasitic leakage. Designers should note that GSR accuracy depends on electrode-skin contact quality and humidity compensation, which is handled in firmware using the AFE's sampled data. This multi-signal integration is why the AS7050 is described by ams OSRAM as a next-generation vital sign sensor platform.

🖥️

Remote Patient Monitoring Peripherals

Clinical and telehealth remote patient monitoring devices use the AS7050-BWLM to capture multi-parameter vitals - pulse rate via PPG, cardiac electrical activity via ECG, and stress indicators via GSR - in a single compact front end, then relay the I2C data to a Bluetooth or cellular module for cloud transmission. The benefit for home-care peripherals is BOM consolidation: one biosignal AFE covers three measurement types that would otherwise each need dedicated signal-conditioning circuitry, shrinking the PCB and simplifying regulatory testing of the analog chain. The WLP package supports disposable or rechargeable patch form factors that patients wear for days. Design considerations include noise isolation between the electrode inputs and the wireless module's switching circuitry, and duty-cycling the AFE between measurement windows to extend battery life. According to the ams OSRAM product page, the AS7050 is explicitly positioned for medical and health sensing applications of exactly this type.

🎧

True Wireless Earbud Health Sensing

In-ear PPG heart-rate sensing in true wireless earbuds is a strong fit for the AS7050-BWLM because the WLP's tiny footprint and the integration of LED drive, photodiode readout, and digitization on one die fit the severe space and power budget inside an earbud shell. The AFE samples the in-ear photoplethysmogram - light modulated by blood flow in ear tissue - and streams samples over I2C to the earbud SoC, which fuses them with IMU data for motion-robust heart rate. Power efficiency of the analog chain matters more here than in wrist wearables since the battery is tens of milliamp-hours; duty-cycled PPG windows triggered by motion detection keep average consumption low. Layout guidance is to keep the optical sensor pair immediately adjacent to the AFE's PPG inputs and to shield the I2C bus from the RF antenna of the earbud's radio. Follow ams OSRAM reference designs for in-ear optical port sealing against ambient light leakage.

⚡

Fitness Band Multi-Vital Tracking

Fitness bands that track heart rate, workout intensity, and stress around the clock benefit from the AS7050-BWLM's three-mode capability: continuous PPG for heart rate, periodic ECG for rhythm spot-checks when the user touches the band electrodes, and GSR for stress and hydration trend detection. Running all three from one AFE reduces the sensor bill of materials versus discrete solutions and simplifies firmware scheduling of measurement windows through the I2C register interface. The WLP lead-free package withstands the reflow profiles of densely populated wearable PCBs shared with the Bluetooth SoC and battery charger. Battery life optimization is the main engineering task: alternate high-rate PPG during workouts with low-duty GSR sampling at rest, using the AFE's configurable sample rates. For mass production, the tape and reel packaging supports high-volume SMT assembly. Verify final electrode and optical stack dimensions against the ams OSRAM mechanical reference designs before tooling the enclosure.

Recommended Products Summary

SFH 7060 Multi-wavelength optical sensor module for PPG Used in: Wrist-Worn Heart Rate Monitoring AS7050-BWLM_REV.C Current revision ordering code of the same AFE Used in: ECG Patch and Chest Strap Recorders, Stress and GSR Monitoring Wearables, Remote Patient Monitoring Peripherals, True Wireless Earbud Health Sensing, Fitness Band Multi-Vital Tracking
What is the AS7050-BWLM?
The AS7050-BWLM is a biosignal sensor analog front end (AFE) from ams OSRAM that enables vital sign detection of photoplethysmogram (PPG), electrocardiogram (ECG), and galvanic skin resistance (GSR) signals. It outputs data over an I2C interface and comes in a lead-free wafer-level package (WLP). According to the ams AG datasheet, it is positioned as the next-generation vital sign sensor for wearable and biomonitoring applications, with PPG being the most used heart-rate monitoring method it supports.
What biosignals can the AS7050-BWLM measure?
The AS7050-BWLM measures three biosignal types: PPG (photoplethysmogram), ECG (electrocardiogram), and GSR (galvanic skin resistance). PPG is the most widely used heart-rate monitoring method, measuring pulse rate by sampling light modulated by blood vessels that expand and contract with blood flow. ECG captures the heart's electrical activity via electrodes, and GSR tracks skin conductance changes used in stress monitoring. This multi-modal capability in a single AFE distinguishes it from single-function PPG front ends.
What interface does the AS7050-BWLM use to communicate with a host microcontroller?
The AS7050-BWLM communicates over an I2C serial interface, as listed on DigiKey's product page which categorizes it as a Biomonitoring Sensor with I2C Output. I2C allows connection to virtually any modern microcontroller with just two wires (SDA and SCL), making it well suited to space-constrained wearable designs. Designers should configure the device registers through I2C for channel selection, LED drive current, and sampling rate settings per the ams OSRAM datasheet guidance.
What package does the AS7050-BWLM come in?
The AS7050-BWLM is offered in a lead-free wafer-level package (WLP), supplied in tape and reel format per the Mouser ordering code AS7050-BWLM_REV.C WLP LF T&R. WLP technology packages the die at wafer level, yielding an extremely small footprint with very short interconnects - essential for smartwatch, fitness band, and earbud form factors. Exact body dimensions and ball map should be confirmed from the manufacturer datasheet's mechanical drawing section.
Where can I buy AS7050-BWLM and is it in stock?
The AS7050-BWLM (ordered as AS7050-BWLM_REV.C WLP LF T&R) is listed at authorized distributors including DigiKey Electronics, Mouser, and via TrustedParts and Octopart aggregator listings, with DigiKey showing 'Buy now, ships today' availability for the REV.C variant. Octopart lists pricing comparison across multiple distributors (5 distributors for the Osram listing). As of 2026-10-11, XAIPART offers this part on a quote/request basis - contact us for current price, stock, and lead time.
What is the price of AS7050-BWLM?
Pricing for the AS7050-BWLM is quote-based at XAIPART as of 2026-10-11, because this is a specialized biosensor AFE whose unit price varies strongly with volume and channel mix. Distributor price breaks can be compared via Octopart, which aggregates bulk discounts from multiple distributors (it reports 5 distributors for the Osram-listed part). For accurate volume pricing at XAIPART, submit a request for quote with your required quantity and delivery schedule.
What is the lead time for AS7050-BWLM?
Lead time for the AS7050-BWLM_REV.C is typically short when distributor stock exists - DigiKey shows 'Buy now, ships today' for in-stock quantities as of 2026-10-11. For larger production volumes sourced through XAIPART, lead time depends on factory allocation from ams OSRAM and typically requires a quotation to confirm. Specialized medical-grade AFEs like this can experience allocation during demand surges in the wearables market, so design-in planning should include a second-source strategy.
What is the difference between AS7050-BWLM and AS7050-BWLM_REV.C?
AS7050-BWLM_REV.C is the current revision-C ordering part number of the same AS7050-BWLM device; the suffix denotes the datasheet/product revision rather than a different silicon function. Distributors such as DigiKey and Mouser list the part under AS7050-BWLM_REV.C with the identical description: biosignal AFE with PPG, ECG, and GSR support, I2C output, WLP lead-free package in tape and reel. For new designs, order the REV.C suffix; earlier revisions are superseded per ams OSRAM product status.
Is the AS7050 suitable for ECG measurement in medical wearables?
Yes - ECG is one of the three native biosignal channels of the AS7050-BWLM, alongside PPG and GSR. According to the ams OSRAM product description, the device was explicitly designed so users can detect ECG biosignals, making it appropriate for chest straps, patches, and wrist devices that capture cardiac electrical activity. Note that regulatory suitability (e.g., for diagnostic-grade medical equipment) depends on your complete system design and certification path; the AFE provides the analog capture chain, while compliance is system-level.
Can AS7058 or other ams OSRAM parts replace the AS7050-BWLM?
Only exact same-package, pin-compatible members of the AS7050 family should be considered drop-in candidates; related ams OSRAM biosignal AFEs (such as the AS7058 family) target different feature sets and are not guaranteed pin-to-pin compatible, so they are functional alternatives requiring board review rather than drop-in replacements. Within the AS7050 family itself, revision-C ordering codes (AS7050-BWLM_REV.C) are the direct replacement for earlier AS7050-BWLM revisions. Always verify the ball map against the latest ams OSRAM datasheet before substituting.
What is the best drop-in replacement for AS7050-BWLM?
The safest drop-in replacement for AS7050-BWLM is its own current revision, AS7050-BWLM_REV.C - identical silicon and package, updated ordering code, stocked at DigiKey and Mouser. No cross-brand pin-compatible biosignal AFE with identical PPG/ECG/GSR integration and WLP footprint was identified in our cross-reference searches as of 2026-10-11. For new layouts, ams OSRAM's AS7058 family offers a functional alternative with a different package, but it requires PCB redesign and is therefore not a drop-in.
What is the best cross-brand equivalent for AS7050-BWLM?
No verified cross-brand pin-compatible equivalent to the AS7050-BWLM was found in our web cross-reference data as of 2026-10-11. Functionally comparable multi-modal biosignal AFEs exist from other manufacturers (for example Maxim/Analog Devices optical sensor AFEs such as the MAX86150, which combines PPG and ECG), but these use different packages and pinouts, requiring PCB redesign. If second-sourcing is mandatory, evaluate the MAX86150 as a functional alternative and budget a layout respin rather than expecting a drop-in swap.
Where can I download the AS7050-BWLM datasheet PDF?
The AS7050-BWLM datasheet PDF is available from aggregator sites such as AllDataSheet (19-page document, 1,016 Kbytes, ams AG) and Octopart's datasheet viewer for AS7050-BWLM_REV.C. The most authoritative source is the ams OSRAM product page at ams-osram.com under the AS7050 Medical and Health Sensor Analog Frontend product listing, which links the current revision-C documentation. Always design from the latest REV.C document since earlier revisions may contain superseded register maps or electrical specifications.
What are the key specifications of AS7050-BWLM that engineers should know?
The ams OSRAM AS7050-BWLM is a biosignal sensor analog front end supporting three measurement modes - PPG, ECG, and GSR - with an I2C digital output and a lead-free wafer-level package (WLP) supplied in tape and reel. Per the 19-page ams AG datasheet, PPG is the most used HRM method and works by sampling light modulated by expanding/contracting blood vessels. It targets vital sign monitoring in wearables and biomonitoring systems. Detailed electrical values (supply voltage, ADC resolution, channel count) should be taken from the REV.C datasheet.
Is AS7050-BWLM the same as AS7050-BWLM_REV.C?
Functionally yes - AS7050-BWLM_REV.C is the revision-C version of the AS7050-BWLM biosignal AFE, and it is the ordering code under which DigiKey, Mouser, and Octopart currently list the part. The REV.C suffix indicates the product/datasheet revision from ams OSRAM, not a different device: both support PPG, ECG, and GSR detection with I2C output in a WLP lead-free package. For new procurement, order REV.C; designs built on older datasheet revisions should review the revision-C change notes before reuse.
When should I choose the AS7050 over a discrete PPG sensor solution?
Choose the AS7050-BWLM when your product needs more than heart rate alone: the integrated PPG + ECG + GSR capability in a single WLP replaces multiple front-end ICs, reduces BOM count, and keeps the analog signal chain under one calibration and control scheme. Choose a discrete single-purpose PPG sensor instead when heart-rate-only tracking suffices, cost is the dominant constraint, and ECG electrodes or GSR electrodes will never be added. The trade-off: the AS7050's flexibility demands more careful PCB layout around its high-impedance electrode inputs.
Does the AS7050-BWLM comply with RoHS?
Yes - the ordering code 'AS7050-BWLM_REV.C WLP LF T&R' explicitly denotes a Lead-Free (LF) packaging option, and Mouser's listings for ams OSRAM parts in this family are shown under RoHS-compliant filters. The wafer-level package construction is compatible with standard lead-free reflow profiles. For formal documentation, download the material declaration and RoHS certificate from the ams OSRAM product page for AS7050-BWLM_REV.C, as XAIPART does not host compliance certificates directly for this part.

Engineering reference data for AS7050-BWLM — comparison, design guidance, and compliance information.

Selection Guide

Choose the AS7050-BWLM (order code AS7050-BWLM_REV.C) when your wearable or patient-monitoring product needs PPG, ECG, and GSR from a single analog front end in a miniature WLP footprint - it is the consolidation play for multi-vital devices. Choose a single-function optical PPG sensor instead if heart rate alone is the requirement and unit cost dominates. If a second source is mandatory, no cross-brand drop-in was verified as of 2026-10-11: functional alternatives such as combined PPG+ECG AFEs from other vendors exist but use different packages and pinouts, so they demand a PCB respin and firmware port. Within ams OSRAM's lineup, related biosignal AFE families cover different feature sets; for designs already qualified on the AS7050, the only safe replacement is the same REV.C part. Confirm electrical details from the 19-page REV.C datasheet before committing the layout.

Comparison with Alternatives

Parameter This Product AS7050-BWLM_REV.C
Package WLP (lead-free) WLP (lead-free) - same
Brand ams OSRAM ams OSRAM
Supported Biosignals PPG, ECG, GSR PPG, ECG, GSR
Digital Interface I2C I2C
Application Domain Vital Sign Monitoring / Biomonitoring Vital Sign Monitoring / Biomonitoring
Lifecycle Status Active Active (current ordering code)
Functional Cross-Brand Alternatives None (this is the reference part) None required - same device

Key Differentiators

  • Three biosignal modalities in one AFE (vs AS7050-BWLM_REV.C (single-channel competitor AFEs))
  • WLP lead-free package for miniaturized wearables (vs Functional alternatives with larger QFN/leads packages)
  • I2C host integration (vs AFE solutions with proprietary or SPI-only interfaces)

Design Notes

The ECG electrode inputs of the AS7050-BWLM are high-impedance nodes that capture microvolt-level cardiac signals. Keep electrode traces as short as practically possible, guard them with driven shield traces where the layout allows, and place the DC-blocking/ESD network directly at the connector. Route the I2C bus and any switching regulator components away from the electrode path - even small capacitive coupling from a switching node can inject artifacts that dominate the ECG waveform. Validate signal quality with the wearer stationary and in motion before freezing the layout.

For the PPG optical channel, the photodiode-to-AFE trace length directly sets susceptibility to ambient light pickup and crosstalk. Place the AS7050-BWLM as close as the mechanical stack allows to the optical window, keep the photodiode anode trace short and guarded, and use a solid ground plane beneath the analog section. Shield the optical cavity from LED side-scatter with an opaque spacer, following the ams OSRAM wearable reference designs. Do not run antenna or RF feed lines under the analog region of a wearable PCB.

Biosignal AFEs in wearables live on battery budgets measured in milliamp-hours, so power-plan the measurement schedule: use the AFE's configurable sample windows to duty-cycle PPG bursts (highest current, LED-driven) while sampling GSR or ECG at lower rates. Decouple the AFE supply with a ceramic capacitor placed at the ball, and prefer a low-noise LDO over a buck converter for the analog rail if a clean rail exists at acceptable efficiency; if a buck is unavoidable, synchronize its switching away from the PPG sampling instants in firmware.

Compliance Information

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Unknown
Conflict Minerals
Unknown

Ordering code AS7050-BWLM_REV.C WLP LF T&R explicitly denotes a Lead-Free (LF) option; Mouser lists ams OSRAM parts in this family under RoHS-compliant filters. REACH and halogen-free status not stated in provided data - confirm via ams OSRAM material declarations.

Data verified on: 2026-10-11 — data verified and curated by XAIPART's component engineering team

Related Searches

AS7050-BWLM datasheet AS7050-BWLM_REV.C buy ams OSRAM AS7050 biosignal AFE PPG ECG GSR analog front end IC AS7050 WLP package vital sign sensor AS7050 heart rate monitoring wearable AS7050-BWLM equivalent replacement AS7050-BWLM price stock what biosignals does AS7050 measure I2C biosignal sensor front end for wearables AS7050-BWLM vs AS7058 AS7050 pinout ball map

Related Components & Terms

ams OSRAM ams AG AS7050-BWLM AS7050-BWLM_REV.C analog front end AFE photoplethysmogram PPG electrocardiogram ECG galvanic skin resistance GSR I2C WLP wafer-level package surface mount RoHS lead-free vital sign monitoring heart rate monitoring biomonitoring wearable health sensor Tape & Reel DigiKey Mouser
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details