DS90CR562MTDX Présentation

The Texas Instruments DS90CR562MTDX is an 18-bit FPD interface line receiver designed for flat-panel display systems. It receives differential data in a 48-TSSOP surface-mount package and belongs to the broader hierarchy of display interface ICs, interface ICs, and integrated circuits. The device is intended for use with compatible TI display link transmitters, including the DS90CF364A family, when a system must transfer multi-bit panel data reliably over a wired differential interface.

The DS90CR562MTDX is identified as an IC line receiver in a 48-pin TSSOP package with gull-wing leads and a rectangular body. Its commercial temperature grade supports design use in ordinary commercial equipment rather than automotive or extended-temperature systems. The X suffix denotes the ordered package configuration, while the related DS90CR562MTD and DS90CR562MTD/NOPB listings identify the same receiver family in the same 48-TSSOP format.

The central benefit of this receiver is integration: an 18-bit wide LVDS-style panel interface consolidates multiple data bits into one display-link receiver rather than requiring a separate single-channel line receiver for every signal. In an FPD system, it complements a parallel-to-differential transmitter that converts low-speed logic signals into a compact differential link. This reduces interconnect width while supporting a more structured approach to display timing and data transfer.

Because the part is a receiver rather than a display timing controller or transmitter, system design must also account for the source transmitter, connector, cable, termination network, and receiving display electronics. LVDS-style links depend on correct differential routing, controlled impedance, suitable input termination, and compliant timing margins. Trace length and pair geometry are therefore as important as nominal pin compatibility when the receiver is installed.

DS90CR562MTDX is appropriate for commercial flat-panel-display equipment, monitor interfaces, industrial display controllers, and other systems using the TI DS90CR562 display-link ecosystem. It should not be selected for an unrelated LVDS standard merely because the connector or protocol looks similar; signal mapping, input thresholds, supply requirements, and timing must match the associated transmitter.

This page combines the exact package and product classification, sourcing links, interface guidance, and drop-in comparison with practical board-level cautions. For a new layout, consult the pin-description table and timing information in the manufacturer datasheet, preserve the receiver’s supply and ground distribution, and validate the complete transmitter-to-receiver link before production release.

Alternatives de remplacement direct pour DS90CR562MTDX — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

DS90CR562MTD/NOPB

✅ Remplacement direct
📦 48-TSSOP
Same 18-bit FPD receiver and 48-TSSOP package; suffix-specific orderable finish or packaging details require confirmation

📋 Alternative de référence (hors catalogue)

DS90CR562MTDX Spécifications

Product Type FPD interface line receiver
Data Width 18 bit
Interface Standard LVDS FPD link
Number of Terminals 48 pins
Package Code TSSOP-48
Package Shape Rectangular
Terminal Form Gull wing
Type de montage Surface mount
Temperature Grade Commercial
Supply Voltage Range 4.5 V to 5.5 V
Receiver Channel Configuration 18-bit wide receiver
Logic Family LVDS
Manufacturer Texas Instruments / National Semiconductor

Guide de configuration des broches du DS90CR562MTDX rectangular

Configuration des broches du DS90CR562MTDX (boîtier rectangular). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.

Schéma de brochage du boîtier rectangular pour le DS90CR562MTDX

Aucune donnée de brochage détaillée disponible pour DS90CR562MTDX.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

DS90CR562MTDX convient pour 6 applications: Commercial Flat-Panel Monitor Interface, Industrial Panel Controller, Display Timing and Data Receiver Card, Medical Panel Display Interface, Point-of-Sale Display Terminal, Video Test and Measurement Equipment.

📺

Commercial Flat-Panel Monitor Interface

The DS90CR562MTDX fits the receiving side of a commercial flat-panel link because it combines an 18-bit FPD receiver function with a 48-TSSOP surface-mount package and a 4.5 V to 5.5 V operating range. It can receive data from a compatible TI panel-link transmitter, reducing the number of separate point-to-point receiver paths needed for wide display words. The layout must preserve differential pair geometry, provide continuous ground references, and include local supply bypass close to the device. Commercial temperature-grade requirements should be checked against the monitor’s enclosure temperature.

🏭

Industrial Panel Controller

For an industrial panel controller, the DS90CR562MTDX provides an 18-bit wide receiver block that can complement a TI display-link transmitter while operating from a 4.5 V to 5.5 V supply. Its integrated 18-bit receiving function supports a more compact panel interconnect than a collection of unrelated single-channel devices. The important design tradeoff is operating grade: the device is identified as commercial grade, so verify its manufacturer-rated temperature limits against the industrial enclosure. Validate the complete link over cable length, connector transitions, grounding, and worst-case timing.

🖥️

Display Timing and Data Receiver Card

The DS90CR562MTDX is suitable for a receiver card that separates panel-link reception from local display processing. Its 18-bit FPD interface and 48-TSSOP package let the card receive a compact differential data stream from a compatible transmitter while supplying organized data to downstream timing or pixel-processing logic. Because this IC does not perform scaling or timing generation, the system must divide transmitter, receiver, and controller functions correctly. Confirm pin-level data mapping and enable sequencing directly from the manufacturer pin table before schematic capture.

💊

Medical Panel Display Interface

The DS90CR562MTDX can be evaluated for a medical display interface when the system uses a compatible TI FPD link and the device remains within its commercial electrical and environmental limits. Its 18-bit receiver consolidates the display data path into one defined interface IC, while the 4.5 V to 5.5 V supply range supports conventional 5 V panel electronics. Medical use does not automatically confer medical qualification; the manufacturer’s operating limits, risk controls, and the system’s applicable requirements must be reviewed. Test long cable, connector, and grounding behavior before production use.

🖥️

Point-of-Sale Display Terminal

The DS90CR562MTDX is appropriate for a point-of-sale terminal that uses a dedicated differential panel link rather than routing wide parallel display signals through a cable. The 18-bit receiver can partner with a compatible DS90CF364A transmitter to carry display data across a more controlled interface. Its 48-TSSOP package supports compact, surface-mount assembly but requires careful thermal and signal-integrity layout. Keep the receiver supply quiet, connect grounds with a low-impedance path, and verify cable length and connector discontinuities against the manufacturer timing specifications.

🔧

Video Test and Measurement Equipment

The DS90CR562MTDX can serve as the receiving element in test equipment that interfaces a compatible TI FPD transmitter to a display, controller board, or signal-analysis fixture. Its 18-bit width allows the interface to be exercised as a complete multi-bit link, and its 4.5 V to 5.5 V supply range is convenient for 5 V test fixtures. Use controlled cables and terminations, observe differential waveforms at the receiver, and confirm enable sequencing during power-up. The receiver’s commercial grade must also be matched to the intended bench or deployed environmental conditions.

Récapitulatif des produits recommandés

DS90CF364AMTDX/NOPB Complementary FPD link transmitter Utilisé dans : Commercial Flat-Panel Monitor Interface, Industrial Panel Controller, Display Timing and Data Receiver Card, Medical Panel Display Interface, Point-of-Sale Display Terminal, Video Test and Measurement Equipment DS90CR562MTD/NOPB Related 48-TSSOP receiver Utilisé dans : Commercial Flat-Panel Monitor Interface, Display Timing and Data Receiver Card, Point-of-Sale Display Terminal DS90CR214MTDX/NOPB Related display-link interface family Utilisé dans : Industrial Panel Controller, Medical Panel Display Interface, Video Test and Measurement Equipment
What is the DS90CR562MTDX?
The DS90CR562MTDX is an 18-bit FPD interface line receiver from Texas Instruments, originally associated with National Semiconductor. It is packaged as a 48-pin TSSOP with gull-wing leads and a rectangular body. According to the manufacturer product listings, its function is to receive differential flat-panel-display data and interface it to compatible display-link transmitter systems. It is an interface IC rather than a timing controller, scaler, or display driver.
Where can I download the DS90CR562MTDX datasheet PDF?
The official DS90CR562MTDX datasheet PDF is available from the Texas Instruments document link on this page. The manufacturer datasheet should be the controlling document for pin assignments, supply limits, electrical characteristics, input thresholds, timing, and recommended application circuits. Product listings identify the device as a 48-TSSOP commercial-grade FPD line receiver. Before layout release, use the datasheet pin-description and recommended-layout sections rather than relying on distributor metadata.
What is the DS90CR562MTDX pinout?
The DS90CR562MTDX uses a 48-pin TSSOP package, but individual signal names cannot be assigned reliably without the manufacturer pin-description table. The verified listings confirm 48 terminals, a TSSOP-48 case, gull-wing leads, and a rectangular package shape. Use the Texas Instruments datasheet to map supply, ground, enable, clock, data, and differential input pins. Do not infer pin functions solely from neighboring DS90CR-series devices because their link widths and channel roles may differ.
What is the DS90CR562MTDX supply-voltage range?
The DS90CR562MTDX operates from a 4.5 V to 5.5 V supply, according to the technical comparison associated with the device listing. This places it in a nominal 5 V interface environment. The range should be treated as the basic operating boundary, while the manufacturer datasheet remains the authority for absolute maximum ratings, current consumption, and conditions for reducing or increasing the supply. A suitable regulator and local decoupling are required in the final board design.
Is DS90CR562MTDX the same as DS90CR562MTD?
The DS90CR562MTDX and DS90CR562MTD belong to the same 48-TSSOP FPD receiver family, but suffix differences can identify ordering, packaging, or finish details. The verified listings show both devices in the 48-pin TSSOP format and identify the base receiver function. Confirm the full ordering code, tape-and-reel requirements, and any suffix-specific commercial terms before treating one as an interchange. The manufacturer should approve substitutions where qualification or traceable-finish requirements apply.
What is the best drop-in replacement for DS90CR562MTDX?
The closest documented drop-in candidate is DS90CR562MTD/NOPB because it is identified as the same 18-bit FPD line receiver in the same 48-TSSOP package. Its listed function, data width, interface type, and supply range align with the DS90CR562MTDX. The full ordering code and suffix-specific finish or packaging details should still be checked before procurement. A different DS90CF364A or DS90CR214 device is a complementary interface function, not a generic substitute.
Can DS90CR562MTDX replace a DS90CR562MTD/NOPB?
The DS90CR562MTDX can be considered for a DS90CR562MTD/NOPB position when the PCB footprint, 5 V supply, receiver enable behavior, link mapping, and timing are unchanged. Both devices are listed as 18-bit FPD line receivers in 48-TSSOP packages. However, suffix handling can affect packaging or finish, so production equivalence should be confirmed against the manufacturer ordering information. Preserve the same bypass network and verify the reset or enable state at power-up.
DS90CR562MTDX vs DS90CF364AMTDX/NOPB — which is better for an FPD link?
The DS90CR562MTDX is the receiver, while the DS90CF364AMTDX/NOPB is a complementary FPD interface device used on the transmitting side. They are not direct drop-in competitors even though both use 48-pin TSSOP packages and participate in TI display-link systems. A practical transmitter-to-receiver design uses each device in its proper role. Choose by link architecture and timing compatibility, not merely by shared package dimensions.
When should I choose DS90CR562MTDX over another 48-TSSOP interface IC?
Choose the DS90CR562MTDX when the system requires an 18-bit wide FPD line receiver with a documented 4.5 V to 5.5 V supply range and a compatible TI display-link transmitter. It is preferable to a transmitter-only device when the PCB position is physically the receiver side of the link. Confirm exact data mapping, clocking, enable polarity, input thresholds, and timing against the associated transmitter before release.
Is DS90CR562MTDX suitable for industrial display applications?
The DS90CR562MTDX can be considered for industrial display systems that operate within its commercial temperature grade and electrical limits. It is identified in the product listings as a commercial-grade receiver, so it should not be assumed suitable for extended-temperature, automotive, or safety-critical environments. Use the manufacturer operating-temperature limits and the system’s environmental requirements. Additional qualification may be necessary when the display equipment must operate outdoors or across a wide industrial temperature range.
Where can I buy DS90CR562MTDX and check its lead time?
Use the Request a Quote form on this page to request DS90CR562MTDX availability, current lead time, and a quotation. One listing states that 2,720 pieces were in stock for reference, but stock can change rapidly and should not be treated as a guaranteed allocation. Include the required quantity, reel format, target date, and shipping destination in the request so procurement can confirm the current manufacturing and distribution status.
What is the price of DS90CR562MTDX?
The current commercial price for DS90CR562MTDX should be requested through the Request a Quote form on this page. Quote-based sourcing is appropriate because distributor listings in the verified results do not provide a qualifying quantity-break price table for this exact MPN. Provide the required quantity and package format with your request for a current response. The historical unit price retained in the structured record is older and is not a current quotation.
Is DS90CR562MTDX in stock?
A distributor listing referenced 2,720 pieces of DS90CR562MTDX as in stock, but inventory is location-dependent and can change without notice. Treat that figure as a point-in-time listing rather than a guaranteed allocation. The fastest way to confirm availability is the Request a Quote form on this page, including the required quantity, packaging format, ship-to region, and target delivery date. Procurement should validate the resulting allocation before committing the production build.
What are the key specifications of DS90CR562MTDX that engineers should know?
The key documented specifications are an 18-bit FPD line receiver function, a 4.5 V to 5.5 V supply range, a 48-pin TSSOP package, commercial temperature grade, surface-mount construction, and gull-wing leads. These characteristics place the device in the display-link receiver category and distinguish it from the DS90CF364A transmitter family. Verify differential timing, enable polarity, propagation delay, and absolute maximum ratings in the manufacturer datasheet before schematic and layout approval.
What can replace DS90CR562MTDX?
DS90CR562MTD/NOPB is the documented closest replacement because it retains the 18-bit FPD receiver function, 48-TSSOP package, and 5 V-class supply operation. No separate cross-brand drop-in equivalent is established by the available cross-reference results. DS90CF364AMTDX/NOPB and DS90CR214MTDX/NOPB perform complementary transmitter functions and therefore are not replacements for the receiver. A substitute also requires validation of timing, pin behavior, and system-level link margins.

Données de référence d'ingénierie pour DS90CR562MTDX — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the DS90CR562MTDX when designing the receiving side of a TI-compatible 18-bit FPD link that uses a 48-TSSOP footprint and a 4.5 V to 5.5 V supply. Select DS90CR562MTD/NOPB as the closest documented drop-in candidate after confirming the ordering suffix and production requirements. Do not use the DS90CF364AMTDX/NOPB as a receiver substitute merely because its package matches; it performs a complementary transmitter role. Likewise, DS90CR214MTDX/NOPB is not a direct replacement for the 18-bit receiver. Before committing to any choice, verify the pin map, enable behavior, data mapping, clocking, propagation delay, input thresholds, and link timing. The target is a commercial-grade device, so environmental requirements and temperature margins also need confirmation for industrial or extended-temperature installations.

Comparaison avec les alternatives

Paramètre Ce produit DS90CR562MTD/NOPB
Brand Texas Instruments Texas Instruments
Package 48-TSSOP 48-TSSOP
Product Function FPD interface line receiver FPD interface line receiver
Data Width 18 bit 18 bit
Interface Type LVDS FPD link LVDS FPD link
Mounting Type Surface mount Surface mount

Principaux différenciateurs

  • Integrated 18-bit FPD receiver function (vs DS90CF364AMTDX/NOPB)
  • Closest documented package-compatible receiver (vs DS90CR562MTD/NOPB)
  • Nominal 5 V-class integration (vs DS90CR562MTD/NOPB)

Notes de conception

Route each differential receiver pair as a tightly coupled, continuously referenced pair with a consistent geometry and controlled impedance. Keep the DS90CR562MTDX close to the connector or transmitter interface, avoid stubs, and place any required termination network directly at the receiver pins. Do not route the link beneath noisy switching nodes. The 18-bit wide interface must be checked as a complete group of differential pairs because mismatched length or asymmetry can introduce skew even when individual nets appear correctly routed.

Provide a stable 4.5 V to 5.5 V supply at the DS90CR562MTDX and place local bypass capacitance close to the supply and ground pins. Keep return current out of the paths used by the differential receiver inputs. Verify startup current, supply tolerance, and ground bounce using the manufacturer electrical characteristics. Since the receiver sits at the end of a display link, supply noise can appear as receiver jitter or data errors even when the transmitter output itself is clean.

Do not treat any DS90CR-family 48-TSSOP device as an automatic substitute. The DS90CF364AMTDX/NOPB and DS90CR214MTDX/NOPB have different interface roles from the DS90CR562MTDX receiver. Confirm the exact device function, pin names, enable polarity, clock topology, supply limits, and signal timing against the manufacturer datasheets. Also verify the ordering suffix because reel, tray, finish, and lead-free markings can affect procurement and assembly documentation even when the electrical function is unchanged.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The available product listings identify a commercial-grade 48-TSSOP FPD receiver but do not provide definitive RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations. AEC-Q100 is not applicable to this commercial interface IC.

Données vérifiées le : 2026-11-16 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

DS90CR562MTDX datasheet DS90CR562MTDX pinout DS90CR562MTDX datasheet pdf DS90CR562MTDX equivalent DS90CR562MTDX replacement DS90CR562MTDX price DS90CR562MTDX stock Texas Instruments DS90CR562MTDX DS90CR562MTDX 48-TSSOP pinout DS90CR562MTDX FPD interface DS90CR562MTDX vs DS90CR562MTD/NOPB DS90CR562MTDX application circuit

Composants & termes associés

Texas Instruments National Semiconductor DS90CR562MTDX DS90CR562MTD DS90CR562MTD/NOPB DS90CF364AMTDX/NOPB DS90CR214MTDX/NOPB FPD interface IC line receiver LVDS flat-panel display interface IC integrated circuit 48-TSSOP TSSOP family surface-mount package 18-bit receiver differential signaling display link commercial temperature grade supply voltage signal integrity point-to-point interface
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ