INA133UA/2K5 - 1.5MHz Difference Amplifier | Texas Instruments
Référence : INA133UA/2K5 ✓ ActifINA133UA/2K5 Présentation
A difference amplifier is a specialized amplifier IC that subtracts two input voltages and amplifies the resulting differential signal. This category belongs to the wider amplifier hierarchy and is used to reject common-mode noise, monitor differential sensor outputs, and measure small voltage changes across high-potential or low-noise systems. The INA133 combines an internal amplifier with a trimmed resistor network to simplify high-accuracy gain configurations.
Principal features include a 1.5 MHz gain-bandwidth product, 450 µV offset specification, and very low 0.95 mA power draw. The /2K5 ordering option identifies the specified differential amplifier configuration, while the UA package designation provides an 8-pin SOIC implementation. These characteristics make the device useful where signal speed and low power must coexist with precision differential input handling.
The INA133 architecture uses laser-trimmed on-chip resistors with low temperature-coefficient tracking. This construction supports accurate gain and common-mode rejection across operating-temperature changes while eliminating the need for a discrete four-resistor subtraction network. Its bandwidth allows the amplifier to process signals beyond static bridge or sensor measurements, although practical usable frequency and accuracy also depend on source impedance, layout, and the required closed-loop response.
Typical applications include current-shunt monitoring, bridge-sensor signal conditioning, precision differential measurement, industrial instrumentation, and low-power sensor interfaces. The amplifier can also serve as the input stage for filtering, control, or conversion circuitry when its bandwidth, offset, supply range, and common-mode performance suit the signal chain.
When laying out the circuit, keep the differential input traces short, symmetric, and away from switching nodes. Resistor networks used to set input and output limits should be placed close to their associated pins, and bypass capacitance should follow the manufacturer’s recommended application circuit. Check input and output swing, common-mode range, and supply limits before adding gain.
This product page consolidates the manufacturer’s principal INA133 specifications with engineering guidance for differential measurement. It also organizes same-package alternatives, design considerations, application fit, and parameter comparisons so engineers can evaluate the INA133UA/2K5 against other precision amplifier implementations before laying out a board.
Alternatives de remplacement direct pour INA133UA/2K5 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
INA133UA/2K5E4
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
INA133U/2K5E4
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
INA133U/2K5
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
INA133UA/2K5.A
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
INA133UA/2K5 Valeurs maximales et caractéristiques électriques
| Product Type | Precision difference amplifier |
| Number of Circuits | 1 circuit |
| Gain-Bandwidth Product | 1.5 MHz |
| Input Offset Voltage | 450 µV |
| Power Consumption | 0.95 mA |
| Boîtier | 8-pin SOIC (D) |
| Nombre de broches | 8 pins |
| Tension d'alimentation | ±18 V maximum, 36 V total maximum |
| Plage de température de fonctionnement | -55 °C to +125 °C |
| Input Configuration | Differential input |
| Configuration de sortie | Differential output |
| Integrated Resistor Network | Laser-trimmed on-chip precision resistor network |
Guide de configuration des broches du INA133UA/2K5 8-pin soic (d)
Configuration des broches du INA133UA/2K5 (boîtier 8-pin soic (d)). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour INA133UA/2K5.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
INA133UA/2K5 convient pour 6 applications: Current-Shunt Monitoring, Bridge-Sensor Signal Conditioning, Industrial Sensor Interfaces, Precision Voltage-Difference Measurements, Test and Measurement Instrumentation, Low-Power Sensor and Control Circuits.
Current-Shunt Monitoring
The INA133UA/2K5 fits precision current-shunt monitoring because its differential input structure is designed to reject voltage common to both shunt terminals. With a 1.5 MHz bandwidth, it can amplify fast current transitions rather than only static DC measurements. Its 450 µV offset contributes directly to current-measurement error when referenced to the shunt resistance, while approximately 0.95 mA operating current supports low-power instrumentation. Place the amplifier close to the shunt, route the sense pair symmetrically, and verify that the shunt voltage, common-mode range, and output swing remain within the operating limits.
Recommandé
Bridge-Sensor Signal Conditioning
The INA133UA/2K5 is appropriate for many bridge-based sensors because it amplifies the small differential voltage generated between the bridge excitation rails. Its precision internal resistor network reduces the matching burden associated with a discrete subtraction circuit, while 450 µV offset establishes a key contribution to the complete error budget. The 1.5 MHz bandwidth accommodates sensors whose output changes are faster than a static bridge measurement. Verify the bridge excitation voltage, common-mode operating region, permissible input polarity, and output swing before finalizing the gain and filter network.
Recommandé
Industrial Sensor Interfaces
The INA133UA/2K5 supports industrial sensor-interface designs requiring accurate differential extraction from noisy or high-impedance sources. Its 1.5 MHz bandwidth provides margin for dynamic sensor signals, and the approximately 0.95 mA power consumption is favorable for distributed or low-power measurement nodes. The amplifier’s laser-trimmed resistor network is designed to maintain gain accuracy and common-mode rejection as temperature changes. The board should include symmetric input routing, local supply bypassing, and protection appropriate to the sensor cable environment, with grounding checked for potential differences across the measurement source.
Recommandé
Precision Voltage-Difference Measurements
The INA133UA/2K5 is useful when a system must measure the difference between two voltages rather than either voltage referenced to ground. Differential operation suppresses shared noise and permits a direct relationship between the bridge or shunt signal and the amplifier output. A 450 µV input offset specification defines the principal static error term, while the 1.5 MHz bandwidth supports signals with meaningful dynamic content. Confirm the input common-mode range and output voltage limits, and account for the 0.95 mA operating current when designing a low-energy acquisition node or portable meter.
Recommandé
Test and Measurement Instrumentation
The INA133UA/2K5 can serve as the precision input stage of a test or measurement instrument that must reject common-mode voltage while amplifying a smaller differential signal. The 1.5 MHz bandwidth supports general-purpose low-frequency and pulse-related measurements, and the integrated trimmed network simplifies gain implementation. Instrumentation designers should account for the 450 µV offset, source-imbalance error, input noise, and output saturation when establishing resolution limits. Short, equal-impedance differential traces, careful grounding, and stable bypass capacitors are important for preserving the precision expected from this amplifier class.
Recommandé
Low-Power Sensor and Control Circuits
The INA133UA/2K5 fits low-power sensor and control circuits where a differential measurement must be conditioned before filtering, conversion, or actuator control. Its approximately 0.95 mA operating current limits the amplifier's contribution to the power budget, while the 1.5 MHz bandwidth provides useful bandwidth beyond static sensor nodes. The device can provide gain in a compact 8-pin SOIC footprint without the component count of a discrete precision difference stage. Confirm the selected gain configuration, operating temperature, supply range, and output swing, and use low-leakage protection components when measuring high-impedance sources.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour INA133UA/2K5 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | INA133UA/2K5E4 | INA133U/2K5E4 | INA133U/2K5 | INA133UA/2K5.A |
|---|---|---|---|---|---|
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Type | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier |
| Gain-Bandwidth Product | 1.5 MHz | 1.5 MHz | 1.5 MHz | 1.5 MHz | 1.5 MHz |
| Power Consumption | 0.95 mA | 0.95 mA | 0.95 mA | 0.95 mA | 0.95 mA |
| Integrated Resistor Network | Laser-trimmed precision resistor network | Laser-trimmed precision resistor network | Laser-trimmed precision resistor network | Laser-trimmed precision resistor network | Laser-trimmed precision resistor network |
Principaux différenciateurs
- Combines differential precision measurement with relatively high bandwidth (vs INA133U/2K5E4)
- Broad temperature-rated ordering option (vs INA133U/2K5)
- Integrated precision resistor network reduces external matching (vs INA133UA/2K5E4)
Notes de conception
Route the two differential inputs as a matched pair with similar geometry and impedance. Minimize loop area between the source and amplifier, especially for shunt and bridge measurements where parasitic resistance can unbalance the inputs. Keep the amplifier and its input-network components close together, and avoid routing sense traces beneath or beside switching-converter nodes. For high-impedance sensors, include guarding on exposed input nodes and use low-leakage protection components.
Check the common-mode input range before applying a signal. The differential input rating does not guarantee operation when both inputs are near a supply rail or outside the usable common-mode window. Also confirm output swing at the selected gain, because a valid input can still drive the output into saturation. Include the 450 µV offset in the accuracy budget and account for source-imbalance error when the two input impedances are not matched.
Follow the manufacturer application circuit for supply bypassing and input/output compensation or stability networks. Place bypass capacitance at the amplifier supply pins rather than at a remote supply connector, and keep its ground return short. Install input protection with suitable clamping and leakage characteristics only when the signal path permits them. Preserve the 8-pin SOIC land pattern and check pin-one orientation carefully before assembly.
The 1.5 MHz gain-bandwidth product does not by itself guarantee a flat 1.5 MHz response at every gain setting. Review the manufacturer gain, bandwidth, phase, and stability plots for the selected INA133 configuration. Add filtering after the amplifier when out-of-band noise or transient behavior must be controlled. Maintain source impedances compatible with the selected gain and avoid excessive capacitive loading directly on the output.
Informations de conformité
The exact INA133UA/2K5 compliance declarations were not stated in the manufacturer or distributor records reviewed. AEC-Q100 is not applicable to the standard catalog ordering option unless a specifically qualified automotive variant is selected.