INA2126PA - Dual 36V Micropower Instrumentation Amplifier | Texas Instruments
Référence : INA2126PA ✓ ActifINA2126PA Présentation
An instrumentation amplifier is a specialized amplifier category used for differential measurement. Its internal signal path amplifies the difference between two inputs while providing high common-mode rejection, making it more suitable for bridge sensors, current loops, and low-level analog front ends than a general-purpose operational amplifier. The INA2126 belongs to the INAx126 family of precision instrumentation amplifiers, combining low power consumption with accurate signal conditioning.
Key characteristics include a 250 μV offset specification, low quiescent current, a wide operating voltage range, and a bandwidth of approximately 200 kHz according to the product listing. The dual configuration provides two independent amplifier channels in one package, reducing component count on multi-axis or multi-sensor boards. The instrument amplifier category is part of the broader linear amplifier hierarchy and ultimately belongs to the analog integrated-circuit and signal-conditioning ecosystem.
The INA2126PA is suitable for portable instrumentation, sensor-interface circuits, battery-powered measurement equipment, industrial process monitoring, and precision data-acquisition systems. Its low 175 μA per-channel current makes it useful when battery life and thermal performance are important. The wide supply range also supports systems operating from low-voltage portable rails or higher-voltage industrial analog rails.
Designers should pay attention to input common-mode range, output swing, gain-setting resistor selection, bypass-capacitor placement, and the effects of source impedance when using precision instrumentation amplifiers. The dual package provides an opportunity to place two channels close together, but differential routing must minimize noise pickup and maintain a consistent ground reference. Use the manufacturer datasheet for the complete electrical characteristics and pin configuration before laying out a new PCB.
This product page combines the INA2126PA device specifications, sourcing information, verified drop-in alternatives, comparison parameters, and practical design guidance to support faster component selection and implementation.
Alternatives de remplacement direct pour INA2126PA — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec INA2126PA (même facteur de forme et même empreinte) — différant par Package, Quiescent Current, Architecture, Product Type, Input Type.
INA128PA
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →INA2126PA Valeurs maximales et caractéristiques électriques
| Product Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 channels |
| Supply Voltage Range | ±1.35 V to ±18 V |
| Maximum Supply Voltage | 36 V |
| Courant de repos | 175 μA per channel |
| Offset Voltage | 250 μV |
| Gain-Bandwidth Product | 200 kHz |
| Input Type | Differential input |
| Architecture | Two-op-amp instrumentation amplifier |
| Boîtier | 16-pin PDIP |
| Package Type | Through-hole PDIP |
| Type de montage | Through-hole |
| Application Category | Precision differential-signal acquisition |
| Portable Operation | Supported by low quiescent current |
Guide de configuration des broches du INA2126PA through-hole pdip
Configuration des broches du INA2126PA (boîtier through-hole pdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour INA2126PA.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
INA2126PA convient pour 6 applications: Portable Sensor Acquisition, Bridge Sensor Interface, Battery-Powered Data Acquisition, Process Monitoring, Precision Data Acquisition, Instrumentation and Test Equipment.
Portable Sensor Acquisition
The INA2126PA fits portable sensor acquisition because its 175 μA per-channel quiescent current limits amplifier contribution to battery drain, while the dual configuration supports two independent measurement channels in one 16-pin PDIP package. Its ±1.35 V to ±18 V operating range allows use with low-voltage portable rails and higher-voltage instrumentation systems. Differential inputs help reject common-mode pickup from sensors and long PCB traces. The result is a compact analog front end for handheld meters, portable environmental monitors, and field-test equipment. Design around the manufacturer datasheet limits for input common-mode voltage, output swing, gain resistors, and supply bypassing.
Recommandé
Bridge Sensor Interface
The INA2126PA is suitable for bridge-sensor front ends that require a differential measurement and low amplifier power consumption. The two-op-amp architecture measures the imbalance between bridge nodes while its instrumentation-amplifier topology addresses common-mode voltage present on both inputs. Two channels can serve paired bridges, load cells, or related sensing elements without adding separate amplifier packages. Its 250 μV offset specification is relevant to low-level millivolt-scale outputs, although actual system error also depends on bridge excitation, resistor tolerance, and ADC resolution.
Recommandé
Battery-Powered Data Acquisition
The INA2126PA supports battery-powered data-acquisition systems where every milliampere affects operating time. Its 175 μA per-channel current allows the dual amplifier to condition two low-level channels without consuming the power associated with higher-current general-purpose amplifiers. The wide supply range of ±1.35 V to ±18 V provides flexibility between compact low-voltage designs and higher-voltage industrial interfaces. Use the part for current-loop sensors, strain-gauge conditioning, and low-level analog monitoring. Validate total system energy use, shutdown behavior, capacitor leakage, and sensor excitation requirements during the power-budget calculation.
Recommandé
Process Monitoring
The INA2126PA can condition differential process signals when low power and channel density are important. Industrial monitoring systems often combine sensors located far from the controller, where common-mode noise and ground differences can contaminate the measurement. The dedicated instrumentation-amplifier architecture is intended to amplify the desired difference between input terminals rather than either input referenced to ground. Two channels support redundant or complementary measurements within one package. Confirm the input common-mode range, output swing, and isolation strategy for each process signal, and follow the manufacturer datasheet when selecting external gain and filtering components.
Recommandé
Precision Data Acquisition
The INA2126PA suits precision data-acquisition front ends that need low-noise differential amplification before an ADC. Its 250 μV offset and 200 kHz bandwidth provide useful starting points for many low-frequency or moderate-bandwidth measurements, while the dual architecture permits synchronized or complementary channel acquisition. Place both channels near the connector or sensor interface and keep differential traces short, matched, and referenced to a clean ground plan. Select gain with suitable resistor accuracy and verify source-imbalance effects using the manufacturer guidance. These practices help preserve the instrumentation amplifier's common-mode rejection and noise performance.
Recommandé
Instrumentation and Test Equipment
The INA2126PA is appropriate for compact instrumentation and test equipment requiring two low-power differential measurement channels. It can condition outputs from pressure, temperature, current, and resistive sensors before conversion or control circuitry. The through-hole 16-pin PDIP package can simplify assembly in laboratory devices, educational instruments, and maintenance equipment where manual insertion and rework are useful. Because instrumentation accuracy depends on the entire analog chain, check gain-resistor tolerance, reference stability, input filtering, and grounding. Use the manufacturer pin configuration and typical application circuits as the basis for board construction.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour INA2126PA — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Notes de conception
Place input, output, and supply bypass components close to their associated INA2126PA pins. Keep each differential input pair short, symmetric, and routed over a continuous ground plane. The two amplifier channels should use matched routing because unequal input impedance and trace capacitance can degrade common-mode rejection and offset balance. Use the manufacturer pin-configuration drawing and typical application circuit to establish the exact connections before PCB routing.
Do not assume that the ±1.35 V to ±18 V supply rating guarantees usable input or output ranges at every gain. Input common-mode voltage, output swing, gain, and supply limits are interdependent, so check the datasheet curves and equations with the worst-case sensor outputs. Also include resistor tolerance and source imbalance when calculating effective offset error; the stated 250 μV offset specification alone does not describe the complete system accuracy.
Estimated: the two amplifier channels consume 350 μA total when each operates at the stated 175 μA quiescent current. This estimate excludes external gain resistors, sensors, protection components, and load current. Use it as the amplifier-only baseline for a battery-power budget, then add the measured or specified current of the rest of the signal chain. Supply bypass capacitors should be selected using the manufacturer recommendations and the impedance requirements of the intended operating bandwidth.
Informations de conformité
The exact package variant has no explicit compliance statement in the cited product material. The dual 36 V instrumentation amplifier is not presented as an automotive-qualified AEC-Q100 device.