An RS-485/RS-422 transceiver is an interface IC that converts between single-ended logic signals and differential, balanced bus signals. A differential receiver rejects common-mode noise, while the balanced driver improves signal integrity and interoperability over cables and long printed-circuit-board traces. In the signal-chain hierarchy, this component is a line transceiver, an interface IC, and part of a broader industrial communication and data-conversion system.
The ISL81487IP combines a 5 V supply with a 1/8 unit-load receiver characteristic. Fractional unit loading permits more receiving nodes on the same bus than a full-unit-load receiver, which is valuable in multi-drop RS-485 networks. Its BiCMOS implementation combines low power use with high input impedance, while the balanced differential interface supports both RS-485 and RS-422 point-to-point or multidrop communication.
The family supports two operating profiles: a high-speed profile for data-transfer links and a slew-rate-limited profile for reduced electromagnetic interference and improved control of bus-edge transitions. This flexibility allows the same physical interface concept to address factory automation, instrumentation, and industrial control networks. Package-level ESD protection is specified for the related ISL81487E family at ±15 kV HBM without latch-up.
Typical uses include isolated and non-isolated industrial RS-485 buses, RS-422 links between controllers and peripherals, data acquisition systems, barcode or identification equipment, and embedded control modules. The 1/8 unit-load characteristic is particularly useful where the bus contains multiple receivers, while the through-hole 8-PDIP format supports prototype boards, legacy control equipment, and repair assemblies.
When connecting the ISL81487IP to a multidrop bus, use a termination strategy appropriate for the cable length, topology, and baud rate. Keep the differential pair routed with continuous return-path reference, avoid unnecessary stubs, and place interface-protection components close to the connector. The driver enable and receiver enable functions must also be controlled correctly when the same transceiver supports half-duplex operation.
This product record combines the manufacturer family information with practical interface guidance, verified drop-in candidates, and a parameter-by-parameter comparison. It is designed to help engineers confirm package compatibility, bus loading, ESD capability, and replacement suitability before incorporating the ISL81487IP into an RS-485 or RS-422 design.
Alternatives de remplacement direct pour ISL81487IP — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
ISL81487EIP
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ISL81487LIP
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ISL81487LIPZ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ISL81487EIPZ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ST485EBN
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ISL81487IP Spécifications
| Product Type | Single RS-485/RS-422 transceiver |
| Configuration | 1 driver / 1 receiver, half-duplex |
| Tension d'alimentation | 5 V |
| Receiver Unit Load | 1/8 unit load |
| Interface Standards | RS-485 and RS-422 |
| Process Technology | BiCMOS |
| Operating Mode | High-speed or slew-rate limited |
| Boîtier | 8-PDIP |
| Type de montage | Through-hole |
| ESD Protection | ±15 kV HBM for the related ISL81487E family |
| Latch-Up Resistance | Protected without latch-up for the related ISL81487E family |
| Minimum Load Specification | 10% tolerance specified for the related ISL81487E family |
Guide de configuration des broches du ISL81487IP 8-pdip
Configuration des broches du ISL81487IP (boîtier 8-pdip). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour ISL81487IP.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
ISL81487IP convient pour 6 applications: Industrial RS-485 Control Bus, RS-422 Point-to-Point Data Link, Data Acquisition and Instrumentation, Embedded Controller Communication Port, Building Automation and Environmental Monitoring, Legacy Equipment and Communication Repair.
Industrial RS-485 Control Bus
The ISL81487IP fits industrial control buses because it combines a 5 V supply with a 1/8 unit-load receiver, allowing more receiving nodes to share the same differential pair than a one-unit-load design would permit. It is installed between a host controller and RS-485 peripherals, with the driver enabled only while transmitting. The balanced interface helps reject common-mode noise encountered around motors, relays, and factory automation equipment. Confirm the final baud rate against the family data rate, use termination only at the intended cable endpoints, and preserve a continuous ground reference along the bus.
Recommandé
RS-422 Point-to-Point Data Link
The ISL81487IP can form one side of an RS-422 point-to-point link between a controller and a remote peripheral. The one-driver, one-receiver, half-duplex arrangement supports command and response traffic while the 5 V operation aligns with conventional industrial logic supplies. Its balanced differential signaling reduces susceptibility to common-mode noise relative to single-ended communication. Choose a differential pair with controlled impedance, keep the driver disabled during receive intervals, and validate cable length against the required data rate and the manufacturer's propagation-delay characteristics.
Recommandé
Data Acquisition and Instrumentation
The ISL81487IP is appropriate for laboratory and industrial data-acquisition equipment that must transfer measurements across a longer balanced cable rather than relying on a short point-to-point logic connection. The receiver's 1/8 unit-load characteristic supports shared buses with multiple instrument nodes, while the half-duplex architecture limits the number of physical conductors. Place the transceiver close to the external connector, provide surge and ESD protection at the interface boundary, and use the family’s slew-rate-limited or high-speed profile according to the cable length and measured channel requirements.
Recommandé
Embedded Controller Communication Port
The ISL81487IP can add a wired balanced communication port to an embedded controller that already operates from a 5 V rail. The transceiver converts the controller's logic-level transmit and receive signals to a differential bus, simplifying integration with RS-485 remote I/O or RS-422 peripherals. Its through-hole 8-PDIP package also supports educational, prototype, repair, and legacy automation boards. The design must interlock driver and receiver enables properly, and firmware should account for the half-duplex turnaround delay and the propagation delay specified for the selected family variant.
Recommandé
Building Automation and Environmental Monitoring
The ISL81487IP is suitable for building-automation panels and environmental-monitoring nodes where sensors, controllers, or monitoring stations communicate over a wired balanced network. Its 1/8 unit-load receiver can reduce bus loading when multiple distributed nodes are present, and the 5 V supply supports low-power embedded equipment. Route the differential pair away from switching power stages and high-current relays, use a proper common reference within the RS-485 application constraints, and include connector-level surge protection for cables that leave the enclosure.
Recommandé
Legacy Equipment and Communication Repair
The ISL81487IP through-hole package makes it useful for repairing or extending legacy RS-485 and RS-422 equipment that uses an 8-pin DIP transceiver. The one-driver, one-receiver configuration matches the common half-duplex bus architecture found in older industrial controllers, converters, and interface adapters. Before installation, compare the replacement's enable polarity and timing with the failed device, inspect the board for compromised copper and damaged isolation components, and verify the bus's termination and biasing arrangement. If the original assembly used a different speed-control profile, confirm propagation delay and maximum data rate before energizing the circuit.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ISL81487IP — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ISL81487EIP | ISL81487LIP | ISL81487LIPZ | ISL81487EIPZ | ST485EBN |
|---|---|---|---|---|---|---|
| Package | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP | 8-PDIP |
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | STMicroelectronics |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
| Receiver Unit Load | 1/8 unit load | 1/8 unit load | 1/8 unit load | 1/8 unit load | 1/8 unit load | 1/8 unit load |
| Transceiver Configuration | 1 driver / 1 receiver, half-duplex | 1 driver / 1 receiver, half-duplex | 1 driver / 1 receiver, half-duplex | 1 driver / 1 receiver, half-duplex | 1 driver / 1 receiver, half-duplex | 1 driver / 1 receiver, half-duplex |
| Supported Interfaces | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 |
Principaux différenciateurs
- Maintains the same core bus-loading characteristic (vs ST485EBN)
- Same-package family replacement with explicit ESD option (vs ISL81487EIP)
- Supports both high-speed and slew-rate-limited communication (vs ISL81487LIP)
Notes de conception
Route the differential pair as a continuous impedance-controlled pair from the transceiver to the connector, and keep it away from switching regulators, relays, and high-current return paths. The balanced receiver reduces susceptibility to common-mode noise, but common-mode range and ground-reference limitations still apply. Confirm that the board’s ground topology satisfies the RS-485 application guidance before finalizing the interface return conductor.
Do not enable the driver and receiver paths simultaneously when they share the same bus pins in half-duplex mode. Firmware or hardware should interleave driver enable and receiver enable around the transmission turnaround interval. Also avoid placing termination resistors at every node; use them only at the physical endpoints of the cable and according to the selected baud rate, cable length, and topology.
Choose the high-speed or slew-rate-limited operating profile according to channel length and EMI requirements. A slower controlled edge can reduce ringing and radiated emissions, while a high-speed profile supports greater throughput. Validate the selected family member with the longest intended cable, realistic termination, industrial noise levels, and the system’s required bit rate before releasing the design.
Informations de conformité
The interface IC is not presented as an automotive-qualified AEC-Q100 product. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer or the orderable part documentation.