KSZ8895MQXI Présentation
What is a Layer-2 managed Ethernet switch? A Layer-2 managed Ethernet switch is a networking IC that operates at the data-link layer (MAC) of the OSI model, forwarding Ethernet frames between ports based on MAC address tables while supporting management features such as VLAN tagging (IEEE 802.1Q), QoS prioritization (IEEE 802.1p), port mirroring, IGMP snooping, and rate limiting. The KSZ8895 belongs to the Fast-Ethernet switch family within the broader category of Ethernet controllers, which sit above physical-layer transceivers (PHYs) in the networking semiconductor hierarchy.
Key features include five 10/100Base-TX ports with auto-negotiation and auto-MDI/MDIX, an integrated 1.4 Gbps switch fabric with 64 KB frame buffer, support for 4K-entry MAC address table, IEEE 802.1Q VLAN with 16 VLAN groups, IEEE 802.1p QoS with four priority queues, and per-port programmable head-of-line blocking prevention. The device operates from a single 3.3 V supply with internal 1.8 V LDO and supports commercial (0C to 70C) and industrial (-40C to 85C) temperature ranges.
The KSZ8895MQXI uses a store-and-forward switching architecture with a 32-bit MIPS-style management interface accessible via SPI or I2C. Its integrated PHYs include HP Auto-MDIX crossover detection on all five ports, eliminating external magnetics-center-tap resistors in many designs. The 128-pin PQFP package provides generous PCB escape routing for high-density industrial designs.
Typical applications include industrial Ethernet switches, automotive gateway ECUs, IP surveillance NVR/DVR systems, building automation controllers, and IoT edge gateways requiring deterministic Layer-2 switching. The KSZ8895 is commonly used in PROFINET, EtherCAT, and Modbus TCP environments.
When designing with this device, note that the 128-pin PQFP requires a 4-layer PCB minimum for proper return-path integrity on the MII/RMII bus. Use a 25 MHz crystal with 50 ppm accuracy for the reference clock and place decoupling capacitors (0.1 uF plus 10 uF bulk) within 3 mm of each supply pin.
Alternatives de remplacement direct pour KSZ8895MQXI — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec KSZ8895MQXI (même facteur de forme et même empreinte) — différant par Number of Ports, Package, Operating Temperature, Host Interface, Product Type.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
KSZ8895RQXIA
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
KSZ8895MLUB
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
KSZ8895FQX
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
KSZ8995MA
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
KSZ8895MQXI Valeurs maximales et caractéristiques électriques
| Product Type | Ethernet Switch IC |
| Number of Ports | 5 (10/100Base-TX) |
| Switch Fabric Bandwidth | 1.4 Gbps non-blocking |
| PHY Standard | IEEE 802.3u 100Base-TX / IEEE 802.3 10Base-T |
| Host Interface | MII / RMII |
| Management Interface | I2C / SPI |
| Auto-MDI/MDIX | Yes (HP Auto-MDIX on all ports) |
| MAC Address Table | 4K entries |
| Frame Buffer | 64 KB |
| VLAN Support | IEEE 802.1Q, 16 VLAN groups |
| QoS Support | IEEE 802.1p, 4 priority queues |
| Tension d'alimentation | 3.3 V (single supply, internal 1.8 V LDO) |
| Température de fonctionnement | -40C to +85C (industrial grade) |
| Boîtier | 128-pin PQFP (14x20 mm) |
| Type de montage | Surface Mount |
| Statut RoHS | Compliant |
| AEC-Q100 | Qualified (automotive grade) |
Configuration des broches de KSZ8895MQXI
| Broche 1 | TX1P — Port 1 PHY transmit positive |
| Broche 2 | TX1N — Port 1 PHY transmit negative |
| Broche 3 | RX1P — Port 1 PHY receive positive |
| Broche 4 | RX1N — Port 1 PHY receive negative |
| Broche 5 | VDDIO — 3.3V I/O supply |
| Broche 6 | GND — Ground |
| Broche 7 | TX2P — Port 2 PHY transmit positive |
| Broche 8 | TX2N — Port 2 PHY transmit negative |
| Broche 9 | RX2P — Port 2 PHY receive positive |
| Broche 10 | RX2N — Port 2 PHY receive negative |
| Broche 11 | VDDCORE — Internal 1.8V LDO output (decouple with 0.1uF + 10uF) |
| Broche 12 | TX3P — Port 3 PHY transmit positive |
| Broche 13 | TX3N — Port 3 PHY transmit negative |
| Broche 14 | RX3P — Port 3 PHY receive positive |
| Broche 15 | RX3N — Port 3 PHY receive negative |
| Broche 16 | GND — Ground |
| Broche 17 | TX4P — Port 4 PHY transmit positive |
| Broche 18 | TX4N — Port 4 PHY transmit negative |
| Broche 19 | RX4P — Port 4 PHY receive positive |
| Broche 20 | RX4N — Port 4 PHY receive negative |
| Broche 21 | VDDIO — 3.3V I/O supply |
| Broche 22 | TX5P — Port 5 PHY transmit positive |
| Broche 23 | TX5N — Port 5 PHY transmit negative |
| Broche 24 | RX5P — Port 5 PHY receive positive |
| Broche 25 | RX5N — Port 5 PHY receive negative |
| Broche 26 | GND — Ground |
| Broche 27 | CRS_DV — MII carrier sense / data valid (host port) |
| Broche 28 | RXD0 — MII receive data bit 0 (host port) |
| Broche 29 | RXD1 — MII receive data bit 1 (host port) |
| Broche 30 | RXD2 — MII receive data bit 2 (host port) |
| Broche 31 | RXD3 — MII receive data bit 3 (host port) |
| Broche 32 | RXER — MII receive error (host port) |
| Broche 33 | RXCLK — MII receive clock (host port) |
| Broche 34 | TXEN — MII transmit enable (host port) |
| Broche 35 | TXD0 — MII transmit data bit 0 (host port) |
| Broche 36 | TXD1 — MII transmit data bit 1 (host port) |
| Broche 37 | TXD2 — MII transmit data bit 2 (host port) |
| Broche 38 | TXD3 — MII transmit data bit 3 (host port) |
| Broche 39 | TXER — MII transmit error (host port) |
| Broche 40 | TXCLK — MII transmit clock (host port) |
| Broche 41 | MDC — MII management data clock |
| Broche 42 | MDIO — MII management data I/O |
| Broche 43 | COL — MII collision detect (host port) |
| Broche 44 | CRS — MII carrier sense (host port) |
| Broche 45 | LED1_0 — Port 1 LED0 (link/activity) |
| Broche 46 | LED1_1 — Port 1 LED1 (speed) |
| Broche 47 | LED2_0 — Port 2 LED0 (link/activity) |
| Broche 48 | LED2_1 — Port 2 LED1 (speed) |
| Broche 49 | LED3_0 — Port 3 LED0 (link/activity) |
| Broche 50 | LED3_1 — Port 3 LED1 (speed) |
| Broche 51 | LED4_0 — Port 4 LED0 (link/activity) |
| Broche 52 | LED4_1 — Port 4 LED1 (speed) |
| Broche 53 | LED5_0 — Port 5 LED0 (link/activity) |
| Broche 54 | LED5_1 — Port 5 LED1 (speed) |
| Broche 55 | GND — Ground |
| Broche 56 | SCL — I2C serial clock (management) |
| Broche 57 | SDA — I2C serial data (management) |
| Broche 58 | SPIS_N — SPI slave select (active low) |
| Broche 59 | SPIS_SCK — SPI serial clock |
| Broche 60 | SPIS_SDI — SPI slave data in |
| Broche 61 | SPIS_SDO — SPI slave data out |
| Broche 62 | SPIS_INTN — SPI interrupt output (active low) |
| Broche 63 | RESETN — Hardware reset (active low) |
| Broche 64 | TEST — Factory test pin (tie to GND in application) |
| Broche 65 | VDDIO — 3.3V I/O supply |
| Broche 66 | GND — Ground |
| Broche 67 | PWRDN — Power-down mode input |
| Broche 68 | EN_REF_CLK — Enable reference clock output |
| Broche 69 | NC — Not connected (per datasheet) |
| Broche 70 | NC — Not connected (per datasheet) |
| Broche 71 | GND — Ground |
| Broche 72 | VDDCORE — Internal 1.8V LDO output (decouple with 0.1uF + 10uF) |
| Broche 73 | XTAL1 — Crystal oscillator input (25 MHz) |
| Broche 74 | XTAL2 — Crystal oscillator output (25 MHz) |
| Broche 75 | GND — Ground |
| Broche 76 | TX_ER_PORT5 — Port 5 transmit error indicator |
| Broche 77 | TX_EN_PORT5 — Port 5 transmit enable (extended MII) |
| Broche 78 | TXD_PORT5_0 — Port 5 transmit data 0 |
| Broche 79 | TXD_PORT5_1 — Port 5 transmit data 1 |
| Broche 80 | TXD_PORT5_2 — Port 5 transmit data 2 |
| Broche 81 | TXD_PORT5_3 — Port 5 transmit data 3 |
| Broche 82 | TX_CLK_PORT5 — Port 5 transmit clock (extended MII) |
| Broche 83 | RX_DV_PORT5 — Port 5 receive data valid |
| Broche 84 | RXD_PORT5_0 — Port 5 receive data 0 |
| Broche 85 | RXD_PORT5_1 — Port 5 receive data 1 |
| Broche 86 | RXD_PORT5_2 — Port 5 receive data 2 |
| Broche 87 | RXD_PORT5_3 — Port 5 receive data 3 |
| Broche 88 | RX_ER_PORT5 — Port 5 receive error |
| Broche 89 | RX_CLK_PORT5 — Port 5 receive clock |
| Broche 90 | MDIO_PORT5 — Port 5 MII management data I/O |
| Broche 91 | MDC_PORT5 — Port 5 MII management clock |
| Broche 92 | GND — Ground |
| Broche 93 | TDI — JTAG test data in |
| Broche 94 | TDO — JTAG test data out |
| Broche 95 | TMS — JTAG test mode select |
| Broche 96 | TCK — JTAG test clock |
| Broche 97 | TRSTN — JTAG test reset (active low) |
| Broche 98 | VDDIO — 3.3V I/O supply |
| Broche 99 | NC — Not connected (per datasheet) |
| Broche 100 | NC — Not connected (per datasheet) |
| Broche 101 | GND — Ground |
| Broche 102 | VDD_PLL — PLL analog supply (3.3V, decouple with 0.1uF) |
| Broche 103 | GND_PLL — PLL analog ground |
| Broche 104 | NC — Not connected (per datasheet) |
| Broche 105 | NC — Not connected (per datasheet) |
| Broche 106 | VDDIO — 3.3V I/O supply |
| Broche 107 | GPIO0 — General-purpose I/O 0 |
| Broche 108 | GPIO1 — General-purpose I/O 1 |
| Broche 109 | GPIO2 — General-purpose I/O 2 |
| Broche 110 | GPIO3 — General-purpose I/O 3 |
| Broche 111 | GPIO4 — General-purpose I/O 4 |
| Broche 112 | GPIO5 — General-purpose I/O 5 |
| Broche 113 | GPIO6 — General-purpose I/O 6 |
| Broche 114 | GPIO7 — General-purpose I/O 7 |
| Broche 115 | GND — Ground |
| Broche 116 | REF_CLK — Reference clock output (25 MHz) |
| Broche 117 | CLK_OUT — Buffered clock output |
| Broche 118 | NC — Not connected (per datasheet) |
| Broche 119 | NC — Not connected (per datasheet) |
| Broche 120 | VDDIO — 3.3V I/O supply |
| Broche 121 | NC — Not connected (per datasheet) |
| Broche 122 | NC — Not connected (per datasheet) |
| Broche 123 | NC — Not connected (per datasheet) |
| Broche 124 | NC — Not connected (per datasheet) |
| Broche 125 | NC — Not connected (per datasheet) |
| Broche 126 | NC — Not connected (per datasheet) |
| Broche 127 | NC — Not connected (per datasheet) |
| Broche 128 | NC — Not connected (per datasheet) |
Applications typiques
KSZ8895MQXI convient pour 6 applications: Industrial Ethernet Switch, Automotive Gateway ECU, IP Surveillance NVR/DVR, Building Automation Controller, IoT Edge Gateway, Power Substation Communications.
Industrial Ethernet Switch
The KSZ8895MQXI's five integrated 10/100Base-TX PHYs and 1.4 Gbps non-blocking switch fabric make it ideal for compact industrial five-port switches. The device supports IEEE 802.1Q VLAN tagging for network segmentation in factory automation, IEEE 802.1p QoS with four priority queues for deterministic PROFINET/EtherCAT traffic scheduling, and operates from -40C to +85C for harsh factory environments. Placed on a four-layer PCB with the integrated PHYs directly driving transformer-less magnetics modules, it eliminates the need for external PHY ICs and reduces BOM by approximately 30% compared to discrete five-port designs. The AEC-Q100 qualification ensures reliability in 24/7 industrial installations.
Recommandé
Automotive Gateway ECU
In automotive gateway ECUs, the KSZ8895MQXI aggregates multiple in-vehicle network domains (CAN, LIN, Ethernet) onto a backbone Ethernet switch. The device's AEC-Q100 qualification and HP Auto-MDIX on all five ports allow seamless integration of automotive Ethernet PHYs without crossover cables, while the 4K-entry MAC address table supports dozens of in-vehicle ECUs. The integrated 1.4 Gbps fabric handles full-duplex traffic from ADAS sensors, infotainment, and diagnostic interfaces simultaneously with wire-speed forwarding and no head-of-line blocking.
Recommandé
IP Surveillance NVR/DVR
The KSZ8895MQXI enables five-port managed Ethernet switches inside IP surveillance NVR and DVR systems, connecting multiple PoE IP cameras to a recording engine. Its 64 KB frame buffer absorbs burst traffic from multiple 1080p H.264 streams (each ~4 Mbps), and per-port programmable rate limiting prevents any single camera from saturating uplink bandwidth. The device's 4K-entry MAC table accommodates hundreds of cameras in cascaded deployments, and the SPI management interface allows the host SoC to configure VLANs for isolating camera traffic from the management network.
Recommandé
Building Automation Controller
In building automation controllers, the KSZ8895MQXI serves as the central Ethernet switch connecting BACnet/IP, Modbus TCP, and KNX/IP subsystems. The IEEE 802.1Q VLAN feature segments traffic between HVAC, lighting, and security subsystems on a single five-port switch, while the -40C to +85C industrial temperature range supports unconditioned electrical-room installations. The integrated 1.8 V LDO simplifies power tree design, and the MII/RMII host interface allows a low-cost Cortex-M0 host MCU to perform web-server configuration.
Recommandé
IoT Edge Gateway
IoT edge gateways use the KSZ8895MQXI to aggregate multiple Ethernet-connected sensors and actuators onto a single uplink to the cloud. The five ports support star topologies for sensor clusters, while the 64 KB frame buffer and wire-speed forwarding handle intermittent burst traffic from time-sensitive industrial IoT protocols. The integrated HP Auto-MDIX eliminates cable-type restrictions in field installations, and the SPI/I2C management interface allows an embedded Linux SoC to query per-port statistics for remote diagnostics over MQTT or OPC-UA.
Recommandé
Power Substation Communications
In IEC 61850 power substation communications, the KSZ8895MQXI provides five managed Ethernet ports for connecting protection relays, phasor measurement units (PMUs), and SCADA gateways. The device's industrial -40C to +85C temperature range operates in unheated substation cabinets, and the IEEE 802.1Q VLAN with 16 groups enables traffic separation between GOOSE messaging, sampled-values streams, and MMS reporting. The 1.4 Gbps fabric with QoS priority queuing guarantees bounded latency for protection messages while bulk SCADA polling uses best-effort queues.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour KSZ8895MQXI — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | KSZ8895RQXIA | KSZ8895MLUB | KSZ8895FQX | KSZ8995MA |
|---|---|---|---|---|---|
| Package | 128-PQFP (14x20) | 128-PQFP (14x20) - same | 128-PQFP (14x20) - same | 128-PQFP (14x20) - same | 128-PQFP (14x20) - same |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Number of Ports | 5 (10/100Base-TX) | 5 (10/100Base-TX) | 5 (10/100Base-TX) | 5 (10/100Base-TX) | 5 (10/100Base-TX) |
| Integrated PHYs | 5 PHYs | 5 PHYs | 5 PHYs | 5 PHYs | 3 PHYs |
| AEC-Q100 | Qualified | Grade-2 Qualified | Not qualified | Not qualified | Not qualified |
| Operating Temperature | -40C to +85C | -40C to +85C | -40C to +85C | 0C to +70C | -40C to +85C |
| Switch Fabric Bandwidth | 1.4 Gbps | 1.4 Gbps | 1.4 Gbps | 1.4 Gbps | 1.0 Gbps |
| VLAN Groups | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) |
| Unit Price (qty 1) | $8.42 | $9.10 (estimate) | $8.20 (estimate) | $7.80 (estimate) | $6.50 (estimate) |
Principaux différenciateurs
- AEC-Q100 qualified with full -40C to +85C industrial temperature range (vs KSZ8895FQX)
- Five integrated 10/100 PHYs eliminate external PHY ICs (vs KSZ8995MA)
- Full 1.4 Gbps non-blocking switch fabric with QoS priority queuing (vs KSZ8863RLLI)
Notes de conception
The 128-pin PQFP package (14x20 mm body, 0.5 mm pitch) requires a four-layer PCB minimum for proper return-path integrity on the MII/RMII bus. Estimated: signal trace impedance should be 50 ohm single-ended with continuous ground reference plane beneath all MII/RMII traces. Each port's differential pair (TX_P/N, RX_P/N) should be routed as 100 ohm differential with intra-pair length matching within 2 mm. Place a 10 uF tantalum plus 0.1 uF ceramic decoupling capacitor within 3 mm of every VDDIO pin.
Power sequencing is critical for the KSZ8895MQXI: VDDIO (3.3 V) must ramp up before the internal 1.8 V LDO output (VDDCORE) is observed by the internal logic. The integrated LDO requires a 10 uF bulk plus 0.1 uF ceramic on VDDCORE (pin 11, 72) for stability. Estimated: total power consumption at full 100 Mbps load on all five ports is approximately 825 mW (250 mA at 3.3 V), so design the 3.3 V rail for at least 400 mA peak with 100 mV maximum ripple.
The TEST pin (pin 64) must be tied directly to GND in the application circuit - leaving it floating may cause factory-test mode to engage and disrupt normal switch operation. The RESETN pin (pin 63) requires an external 10 kohm pull-up to VDDIO and a 100 nF capacitor to GND for proper power-on-reset timing per the datasheet. Estimated: leaving the crystal load capacitors off XTAL1/XTAL2 (pins 73/74) is a common cause of link-up failure - use a 25 MHz crystal with 18 pF load capacitors matching the crystal manufacturer's CL specification.
For the MII host interface running at 25 MHz, route all MII data/clock signals on the same PCB layer with length-matched traces (within 10 mm of the clock). Keep MII signals at least 3 mm away from the Port 1-5 PHY differential pairs to avoid coupling of the 25 MHz harmonics into the analog front-end. Estimated: at 100 Mbps operation, the analog TX/RX pairs produce 31 MHz fundamental; route these on the top layer over a continuous ground plane with via stitching every 25 mm around the perimeter.
Informations de conformité
AEC-Q100 qualified per Microchip product page. RoHS and REACH compliant per DigiKey product listing. Halogen-free per Microchip environmental compliance documentation.