MCP3423T-E/MF - 18-Bit Dual-Channel Sigma-Delta ADC | Microchip
Référence : MCP3423T-E/MF ✓ ActifMCP3423T-E/MF Présentation
A sigma-delta ADC is a class of analog-to-digital converter that uses continuous-time delta-sigma modulation and digital filtering to convert analog voltages into high-resolution digital codes. It belongs to the ADC and DAC category within data-converter ICs and is used when low noise, good linearity, and precise measurement matter more than very high conversion speed.
The MCP3423 provides two differential measurement channels and up to 18 bits of resolution. Its internal 2.048 V reference simplifies system design by removing the need for an external precision reference in common bipolar-input applications. The two-wire I2C interface reduces the number of required signal lines, while 3.75 SPS conversion capability is suited to slow-changing industrial, environmental, and instrumentation signals.
Its delta-sigma architecture inherently shapes quantization noise toward lower frequencies, helping reject broadband noise when the analog signal bandwidth is limited. The on-board reference and differential inputs are particularly useful for sensor bridges, pressure transducers, current measurements, and low-level instrumentation. Because the converter averages successive samples through digital filtering, input settling and filter behavior must be considered when measuring rapidly changing signals.
Typical uses include industrial process monitoring, precision temperature measurement, bridge-sensor acquisition, laboratory instrumentation, and low-speed data-acquisition systems. The 3 x 3 mm DFN package supports compact designs but requires careful PCB layout, exposed-pad soldering, and low-noise routing. The MCP3423T-E/MF is packaged on tape and reel for automated manufacturing.
For best results, use suitable filtering at each analog input, keep the I2C traces short, provide clean supply and ground connections, and follow the manufacturer datasheet's exposed-pad land pattern. Differential input measurements also require attention to common-mode voltage, source impedance, and conversion timing when calculating measurement uncertainty.
This page combines the manufacturer's core device characteristics with practical analog-layout guidance, application analysis, and same-package replacement information. It highlights where the 18-bit resolution, differential architecture, 2.048 V reference, and 3.75 SPS rate make the MCP3423T-E/MF an effective precision-measurement ADC rather than a high-speed data-conversion solution.
Alternatives de remplacement direct pour MCP3423T-E/MF — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec MCP3423T-E/MF (même facteur de forme et même empreinte) — différant par Digital Interface, Package, Conversion Rate, Resolution, Automatic Calibration.
MCP3423-E/MF
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MCP3423T-E/UN
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MCP3423T-E/MF Valeurs maximales et caractéristiques électriques
| Résolution | 18 bit |
| Number of Channels | 2 differential-input channels |
| ADC Architecture | 1-channel sigma-delta per differential input channel |
| Conversion Rate | 3.75 samples per second |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Digital Interface | I2C serial interface |
| Tension d'alimentation | 3.3 V to 5 V |
| Boîtier | 10-VFDFN exposed-pad package, 3 x 3 mm |
| Type de montage | Surface mount |
| Packaging | Tape and reel |
| Analog Input Type | Differential |
Guide de configuration des broches du MCP3423T-E/MF 10-vfdfn exposed-pad package, 3 x 3 mm
Configuration des broches du MCP3423T-E/MF (boîtier 10-vfdfn exposed-pad package, 3 x 3 mm). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour MCP3423T-E/MF.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
MCP3423T-E/MF convient pour 6 applications: Precision Bridge Sensor Acquisition, Industrial Temperature Measurement, Current and Voltage Monitoring, Environmental and Gas Sensor Readout, Laboratory Instrumentation, Low-Speed Data Acquisition.
Precision Bridge Sensor Acquisition
The MCP3423T-E/MF suits Wheatstone bridge and strain-gauge measurement systems because it provides two differential input channels and up to 18 bits of resolution. The differential topology rejects common-mode voltage and reduces sensitivity to ground noise, while the internal 2.048 V reference gives the converter a defined measurement span of ±2.048 V. Install matched input filtering and balance the bridge network so both channels present similar impedance. The 3.75 SPS conversion rate is appropriate for slowly changing mechanical variables such as load, pressure, or displacement.
Recommandé
Industrial Temperature Measurement
The MCP3423T-E/MF can acquire resistive sensor or conditioned temperature signals when high resolution matters more than rapid sampling. Its 18-bit conversion resolution and differential inputs help distinguish small changes in bridge or resistive networks, while the 2.048 V internal reference removes the routine need for a separate reference source. At 3.75 samples per second, the converter supports thermal monitoring, environmental chambers, and temperature-control loops whose signals change gradually. The analog front end must still provide excitation, current limiting, and any required linearization.
Recommandé
Current and Voltage Monitoring
The MCP3423T-E/MF is suitable for low-level current or voltage monitoring when the measured differential signal fits the ±2.048 V input range. Two differential channels allow simultaneous monitoring of two related quantities, and the 18-bit resolution can represent small changes across a suitably scaled shunt or sensor output. The I2C interface supports straightforward connection to a controller in industrial monitoring equipment. Input protection, filtering, and scaling must be designed so transients and common-mode voltage remain outside the converter’s operating limits.
Recommandé
Environmental and Gas Sensor Readout
The MCP3423T-E/MF can digitize conditioned outputs from environmental, gas, and humidity sensors when the sensor signal is slow and differential. The 18-bit resolution improves the useable resolution of low-amplitude sensor outputs, while the internal 2.048 V reference supports repeatable ratiometric measurements when the sensor and converter share a suitable reference arrangement. Its two channels can monitor a sensor and a compensation signal. Digital filtering inherent to the delta-sigma architecture helps suppress high-frequency noise, but signal bandwidth must be limited appropriately.
Recommandé
Laboratory Instrumentation
The MCP3423T-E/MF is appropriate for laboratory and bench instrumentation that measures slow, high-resolution analog quantities. Its differential inputs help reject interference, the 2.048 V internal reference simplifies system calibration, and the I2C interface allows a controller to configure and retrieve conversion results. Two channels support reference and measurement monitoring in compact instruments. Because the conversion rate is 3.75 samples per second, waveform capture is not appropriate; the device instead targets meters, loggers, laboratory monitors, and calibration equipment with quasi-static inputs.
Recommandé
Low-Speed Data Acquisition
The MCP3423T-E/MF fits compact data-acquisition modules that monitor slow-changing voltages with high resolution. Its two differential channels reduce wiring complexity and improve noise immunity compared with single-ended measurements, while the 18-bit conversion core preserves fine detail in scaled sensor outputs. The I2C bus supports connection to embedded controllers, and the 3 x 3 mm DFN package helps minimize board area. Designers should treat the converter as a precision measurement element rather than a general-purpose oscilloscope ADC and account for digital-filter settling after each conversion.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour MCP3423T-E/MF — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MCP3423-E/MF | MCP3423T-E/UN |
|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 10-VFDFN (3 x 3 mm) | 10-VFDFN (3 x 3 mm) | 10-VFDFN (3 x 3 mm) |
| Resolution | 18 bit | 18 bit | 18 bit |
| Input Channels | 2 differential inputs | 2 differential inputs | 2 differential inputs |
| Conversion Rate | 3.75 samples per second | 3.75 samples per second | 3.75 samples per second |
| Internal Reference | 2.048 V | 2.048 V | 2.048 V |
| Differential Input Range | ±2.048 V | ±2.048 V | ±2.048 V |
| Digital Interface | I2C | I2C | I2C |
| ADC Architecture | Delta-sigma | Delta-sigma | Delta-sigma |
| Ordering-Code Difference | MCP3423T-E/MF | T ordering code omitted | Package code changes from MF to UN |
Principaux différenciateurs
- Dual differential inputs in a compact package (vs MCP3423-E/MF)
- Same conversion core with an alternate assembly ordering code (vs MCP3423T-E/UN)
- Integrated precision reference simplifies bipolar measurement (vs MCP3423-E/MF)
Notes de conception
Route each differential input as a short pair with consistent geometry and a continuous ground reference. Place input-series resistors and anti-alias capacitors close to the analog pins, using matched components for both channels when channel matching is important. Keep switching-regulator paths, high-current returns, and digital clock traces away from the MCP3423 input nodes to minimize conversion errors.
Follow the manufacturer datasheet land pattern for the 10-VFDFN exposed-pad package. The exposed pad is both a thermal and electrical connection; provide adequate ground-plane area, solder it according to the manufacturer’s assembly guidance, and avoid unintended thermal coupling from nearby heat sources. Verify paste volume, reflow profile, and via placement with the assembly capability in mind.
Do not treat the 3.75 samples per second rating as a general-purpose sampling rate. Allow for digital-filter settling, and use an anti-alias filter appropriate for the measurement bandwidth. Also check input common-mode voltage, source impedance, and differential range before applying a signal. These checks prevent overload and prevent the converter’s high resolution from being undermined by noise or imbalance.
Informations de conformité
The manufacturer identifies the MCP3423 as an automotive-capable family member, but no specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement is stated for the exact ordering code. AEC-Q100 qualification should be confirmed against the exact Microchip ordering and qualification documentation.