MCP3426A5-E/SN - 16-Bit Dual-Channel Delta-Sigma ADC | Microchip
Référence : MCP3426A5-E/SN ✓ ActifMCP3426A5-E/SN Présentation
A delta-sigma ADC is a voltage regulator–independent type of analog-to-digital converter that uses continuous-time sampling, noise shaping, and digital filtering to provide high-resolution results from low-resolution internal converters. Its hierarchy includes ADC > data converter > analog mixed-signal IC. This architecture is especially useful when low noise, narrow-resolution requirements, and simple I2C integration matter more than very high conversion throughput.
The MCP3426 family provides differential inputs, programmable gain, factory-programmed I2C addresses, and resolution up to 16 bits. The MCP3426A5-E/SN is identified specifically as a 15 SPS, dual-channel device with a sigma-delta architecture and PGA. Its integrated 2.048 V reference removes the need for an external precision reference when the full-scale input remains within the specified differential range.
Its delta-sigma conversion approach prioritizes noise rejection and resolution rather than rapid sampling. The onboard reference establishes a stable conversion scale, while the PGA allows the analog input to be conditioned before conversion. Because the device uses differential inputs, common-mode noise can be reduced when the signal source and return path are balanced correctly, although the input arrangement still requires careful attention to source impedance and grounding.
Typical uses include industrial process measurement, current monitoring, bridge-sensor interfaces, laboratory instrumentation, portable instrumentation, and low-frequency acquisition systems. Two channels are useful when a design must compare a sensor signal with another analog quantity or measure differential inputs across multiple multiplexed sources. For battery-powered equipment, the low-rate conversion capability supports controlled acquisition cycles, but system-level sleep strategy and reference behavior must be evaluated during power-budget calculations.
PCB implementation should keep the analog input traces short, route them away from switching nodes and high-current paths, and provide a quiet ground return. Input filtering and source settling must be coordinated with the selected conversion rate. Firmware should also read the factory-programmed I2C address associated with the A5 device variant rather than assuming the address used by another MCP3426A-series member.
This page combines the manufacturer device description, verified package and converter details, replacement guidance, and practical interface-design considerations. It helps engineers distinguish protocol-compatible variants, plan acquisition firmware, and assess whether the MCP3426A5-E/SN matches a precision, low-speed measurement design.
Alternatives de remplacement direct pour MCP3426A5-E/SN — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec MCP3426A5-E/SN (même facteur de forme et même empreinte) — différant par Package, Differential Input Range, Conversion Rate, Operating Temperature Range, Resolution.
MCP3426A1-E/SN
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MCP3426A2-E/SN
✅ Remplacement direct ⚠️ Spécifications non vérifiéesContactez-nous pour le prix
Voir la fiche technique →MCP3426A3-E/SN
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
MCP3426A4-E/SN
✅ Remplacement direct ⚠️ Spécifications non vérifiéesContactez-nous pour le prix
Voir la fiche technique →MCP3426A5T-E/SN
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MCP3426A5-E/SN Valeurs maximales et caractéristiques électriques
| ADC Type | Sigma-delta ADC |
| Résolution | 16 bit |
| Number of Channels | 2 channels |
| Number of ADCs | 1 ADC |
| Input Type | Differential |
| Conversion Rate | 15 SPS |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Programmable Gain Amplifier | Available |
| Digital Interface | I2C |
| I2C Address | Factory programmed for the A5 variant |
| Boîtier | 8-SOIC, 3.90 mm width |
| Nombre de broches | 8 pins |
| Type de montage | Surface mount |
| Plage de température de fonctionnement | -40 °C to +125 °C |
Guide de configuration des broches du MCP3426A5-E/SN 8-soic, 3.90 mm width
Configuration des broches du MCP3426A5-E/SN (boîtier 8-soic, 3.90 mm width). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour MCP3426A5-E/SN.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
MCP3426A5-E/SN convient pour 6 applications: Industrial Process Measurement, Current Shunt Measurement, Bridge Sensor Interface, Portable Instrumentation, Laboratory Measurement Equipment, Environmental Monitoring.
Industrial Process Measurement
The MCP3426A5-E/SN fits low-speed industrial process monitoring because it combines a 16-bit converter, two differential input channels, and a 15 SPS conversion rate. The integrated 2.048 V reference establishes a stable conversion range of ±2.048 V, while the PGA can bring lower-level sensor outputs into that span. A controller can read process pressure, temperature, or level through I2C while rejecting common-mode noise in a balanced differential input arrangement. The design should include protected sensor wiring, input filtering, and a ground-return strategy that avoids switching-node currents.
Recommandé
Current Shunt Measurement
The MCP3426A5-E/SN is suitable for measuring a differential voltage across a current shunt when the signal remains within the converter's usable input range. Differential inputs help separate the small shunt voltage from common-mode noise, while 16-bit resolution supports precise current monitoring and power calculations. The 15 SPS rate is appropriate for average power, battery-current, or actuator-current measurements rather than instantaneous waveform capture. Firmware should configure the PGA and sample averaging to balance resolution, conversion time, and input settling time.
Recommandé
Bridge Sensor Interface
The MCP3426A5-E/SN can serve as the low-noise ADC stage for a resistive bridge sensor such as a strain gauge, pressure bridge, or load cell. Its differential inputs accommodate the small bridge imbalance signal more effectively than a single-ended input would, while the programmable gain stage reduces the need for a separate analog amplifier. The integrated 2.048 V reference and 16-bit resolution support precise ratio-based measurements. Because the converter rate is only 15 SPS, the system should use controlled excitation and settling periods rather than assume continuous real-time sampling.
Recommandé
Portable Instrumentation
The MCP3426A5-E/SN fits portable measurement instruments that record slowly changing analog values and value low noise and simple digital integration. Its two differential channels allow one instrument to monitor a primary sensor and a secondary reference quantity, while the I2C interface keeps the connection to a controller compact. The 15 SPS rate supports data logging, calibration checks, and periodic sampling without the storage and bandwidth requirements of a fast converter. Power-conscious designs should account for analog-section activation time and allow the source and input network to settle before each conversion.
Recommandé
Laboratory Measurement Equipment
The MCP3426A5-E/SN is applicable to laboratory instruments that prioritize 16-bit resolution and low-noise differential measurement over rapid sampling. It can acquire one or two slow inputs, such as sensor outputs, reference levels, or control voltages, and transfer each result over I2C. The onboard precision 2.048 V reference simplifies calibration when the measurement range is compatible with the ±2.048 V differential span. For bench equipment, isolate the analog section from digital return currents and validate the input filter against the 15 SPS conversion timing to avoid settling-related errors.
Recommandé
Environmental Monitoring
The MCP3426A5-E/SN can support environmental monitoring systems that measure slow temperature, humidity, pressure, or gas-sensor outputs. Two differential channels are useful when one channel carries the sensor measurement and the other monitors a reference or baseline signal. A 15 SPS conversion rate provides frequent updates for thermal and environmental trends without excessive control-loop traffic. The sensor's output must remain within the converter's common-mode and differential limits, and protection or conditioning may be required for long external sensor wiring, condensation, or electrostatic exposure.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour MCP3426A5-E/SN — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MCP3426A1-E/SN | MCP3426A2-E/SN | MCP3426A3-E/SN | MCP3426A4-E/SN | MCP3426A5T-E/SN |
|---|---|---|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| ADC Architecture | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta |
| Resolution | 16 bit | 16 bit | 16 bit | 16 bit | 16 bit | 16 bit |
| Number of Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Conversion Rate | 15 SPS | 15 SPS | 15 SPS | 15 SPS | 15 SPS | 15 SPS |
| Input Type | Differential | Differential | Differential | Differential | Differential | Differential |
| Internal Reference | 2.048 V precision reference | 2.048 V precision reference | 2.048 V precision reference | 2.048 V precision reference | 2.048 V precision reference | 2.048 V precision reference |
| Interface | I2C | I2C | I2C | I2C | I2C | I2C |
Principaux différenciateurs
- Two-channel differential measurement in one converter (vs MCP3426A1-E/SN)
- Integrated precision reference simplifies fixed-range acquisition (vs MCP3426A2-E/SN)
- Low-speed high-resolution conversion suited to sensor monitoring (vs MCP3426A3-E/SN)
- Factory-programmed address supports structured multi-device bus planning (vs MCP3426A4-E/SN)
Notes de conception
Route the two differential input pairs as compact, symmetric traces and provide a direct analog-ground return for each source. Keep the inputs away from switching inductors, relay contacts, motor phases, and high-current output paths. Because the converter measures small differential signals, even a few millivolts of ground offset or coupled switching noise can affect the result. A quiet analog-ground partition and careful return-current control are more important than simply shortening every trace.
Coordinate the source impedance, anti-alias filter, and the 15 SPS conversion timing. The input network must settle between channel selections and conversions, particularly when switching between two sources with different impedances. Use the manufacturer's recommended input-capacitance and filter guidance, and validate the filter cutoff against the converter bandwidth rather than assuming that a larger capacitor always improves accuracy.
Do not substitute an MCP3426A1-E/SN through MCP3426A4-E/SN without updating the I2C address used by firmware. The variants share the 8-SOIC footprint and converter configuration, but the factory-programmed address distinguishes them on the bus. First confirm the device marking and order code, then scan or communicate using the correct address. Also verify the -E and /SN ordering-code requirements against the production BOM.
Separate analog supply routing from noisy digital and switching loads, and place the required bypass capacitance close to the device's supply pins. The MCP3426A5-E/SN combines a precision internal reference with two differential channels, so supply and ground disturbances can affect both channels. Avoid routing return current beneath the analog inputs and keep regulator switching loops confined to the power section rather than the measurement area.
Informations de conformité
Compliance declarations were not stated in the verified product records. The -E ordering suffix denotes an extended-temperature configuration, but it must not be interpreted as an AEC-Q100 qualification statement without an explicit manufacturer declaration.