MPX5100A Présentation

The NXP MPX5100A is an integrated silicon piezoresistive pressure sensor that delivers a calibrated, temperature-compensated analog output from 0.2 V to 4.7 V over an absolute pressure range of 15 kPa to 115 kPa (approximately 2.18 PSI to 16.68 PSI), housed in a 6-SIP through-hole module. Designed for direct connection to a microcontroller or microprocessor A/D input, the sensor integrates a monolithic sensing element with on-chip signal conditioning and bipolar signal processing, eliminating the need for external calibration.

An absolute pressure sensor is a transducer that measures pressure referenced to a perfect vacuum rather than to local atmospheric pressure. Absolute pressure sensors (working in the category hierarchy: pressure sensor -> piezoresistive transducer -> MEMS sensor -> sensor IC -> semiconductor) are critical in applications where the measurement must remain unaffected by changes in weather, altitude, or ambient barometric pressure, making them the preferred choice for sealed-system monitoring and barometric reference.

Key features include a sensitivity of 45 mV/kPa, a typical full-scale span of 4.5 V across the 0 to 115 kPa operating range, and a temperature-compensated output from 0 C to 85 C. The on-chip ASIC linearizes and calibrates the output, producing a near-rail-to-rail analog signal that interfaces directly with most 5 V ADCs. Power consumption is approximately 10 mA from a single 5 V supply, and the device provides ratiometric output, scaling proportionally with supply voltage.

The MPX5100A uses advanced micromachining, thin-film metallization, and bipolar semiconductor processes to combine the mechanical diaphragm and the analog front end on a single die. This patented single-element transducer achieves an accuracy of ±2.5% over the compensated temperature range and provides excellent long-term stability for embedded instrumentation.

Typical applications include barometric pressure measurement for weather stations and altimeters, HVAC airflow and duct pressure monitoring, medical respiratory equipment, industrial process control, and automotive manifold absolute pressure (MAP) sensing. The 0.2 V to 4.7 V output is well-suited for direct ADC input without additional signal conditioning.

When designing with this part, ensure a stable 5 V supply and place a 100 nF decoupling capacitor close to the supply lead. The sensor requires a port reference for absolute measurements and is sensitive to mechanical stress on the package - mount with minimal torque on lead connections and avoid applying side loads to the sensor body. This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.

Alternatives de remplacement direct pour MPX5100A — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MPX5100A (même facteur de forme et même empreinte) — différant par Package, Operating Pressure Range, Accuracy, Pressure Type, Mounting Type.

NXP Semiconductors
Package: 6-SIP Module (Case 867B-04)
Mounting Type: Through-Hole (SIP)
Comparer avec MPX5100A →
NXP Semiconductors
Package: 6-SIP Module (through-hole)
Operating Pressure Range: 0 kPa to 100 kPa (0 to 14.5 PSI)
Accuracy: ±2.5% (0 to 85 °C)
Comparer avec MPX5100A →
NXP Semiconductors
Package: 6-SIP Module (through-hole)
Accuracy: 2.5% over compensated range
Pressure Type: Vented Gauge
Comparer avec MPX5100A →
NXP Semiconductors
Package: 6-SIP Module (Case 867-08)
Operating Pressure Range: 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI)
Mounting Type: Through-Hole (SIP)
Comparer avec MPX5100A →
STMicroelectronics
Package: 8-SMD Gull Wing (SOP 8-surface-mount module)
Operating Pressure Range: 2.18 PSI to 16.68 PSI (15 kPa to 115 kPa)
Accuracy: ±1.5% FS
Comparer avec MPX5100A →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MPX5100AP

✅ Remplacement direct
NXP Semiconductors
📦 6-SIP Module
Absolute · 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI) · 0.2 V to 4.7 V at VCC = 5.0 V · 5.0 V typical (4.75 V to 5.25 V) · 10 mA typical · +/- 2.5% (0 C to 85 C) · 0 C to +85 C

✓ En stock

$12.03 / unité

Voir la fiche technique →

MPX5100DP

✅ Remplacement direct
NXP Semiconductors
📦 6-SIP Module
Differential · 0 kPa to 100 kPa (0 to 14.5 PSI) · 5 V (nominal) · 0.2 V to 4.7 V (ratiometric, ~4.5 V span) · Analog, ratiometric to Vcc · ±2.5% (0 to 85 °C) · 45 mV/kPa nominal

✓ En stock

$12.03 / unité

Voir la fiche technique →

MPX5100GP

✅ Remplacement direct
NXP Semiconductors
📦 6-SIP Module
Vented Gauge · 0 kPa to 100 kPa (0 to 14.5 psi) · 4.75 V to 5.25 V (5 V nominal) · 0.2 V to 4.7 V · 7 mA to 10 mA typical · 4.5 V typical · 2.5% over compensated range · Single axial port, 0.19" (4.93 mm) tube

✓ En stock

$12.03 / unité

Voir la fiche technique →

MPXV5100G

✅ Remplacement direct
📦 6-SIP Module (variant)
surface-mount variant of MPX5100G, same electrical characteristics

📋 Alternative de référence (hors catalogue)

MPX5100AS

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 6-SIP Module
side-port variant, same 15-115 kPa absolute range and 0.2-4.7 V output, identical pinout

📋 Alternative de référence (hors catalogue)

XGZP6872A

✅ Remplacement direct
📦 6-SIP Module
third-party cross-brand equivalent, similar 100 kPa range and analog output, marketed as MPX5100A substitute

📋 Alternative de référence (hors catalogue)

MPX5100A Valeurs maximales et caractéristiques électriques

Pressure Type Absolute
Operating Pressure Range 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI)
Plage de tension de sortie 0.2 V to 4.7 V
Sensitivity 45 mV/kPa
Full-Scale Span (typical) 4.5 V
Tension d'alimentation 5.0 V (typical)
Courant d'alimentation 10 mA (typical)
Accuracy ±2.5% (over compensated temperature range)
Température de fonctionnement 0 C to +85 C (compensated)
Boîtier 6-SIP Module
Type de montage Through-Hole
Port Configuration Single port (absolute)
Type de sortie Analog, ratiometric
Statut RoHS Compliant

Configuration des broches de MPX5100A

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 VCC — 5 V supply input
Broche 2 VOUT — Analog pressure output (0.2 V to 4.7 V)
Broche 3 GND — Ground reference
Broche 4 GND — Ground (tied to pin 3 internally)
Broche 5 NC — Not connected (no internal bond)
Broche 6 NC — Not connected (no internal bond)

Applications typiques

MPX5100A convient pour 6 applications: Barometric Pressure Measurement, HVAC Duct Pressure Monitoring, Medical Respiratory Equipment, Industrial Process Control, Automotive Manifold Absolute Pressure (MAP) Sensing, Weather Station / Altimeter.

🌐

Barometric Pressure Measurement

The MPX5100A's 15 to 115 kPa absolute range covers the full span of barometric pressure variations from severe low-pressure weather systems (~95 kPa) to strong high-pressure systems (~105 kPa). With 45 mV/kPa sensitivity and 0.2 V to 4.7 V output, it connects directly to a 5 V microcontroller ADC without signal conditioning. Unlike gauge sensors, it references a sealed vacuum, eliminating weather drift in weather stations, altimeters, and GPS-aiding pressure references. Place the sensor with the port open to ambient air and apply a small weatherproof cover to prevent wind-driven pressure fluctuations.

🏭

HVAC Duct Pressure Monitoring

The MPX5100A's absolute pressure range comfortably covers typical HVAC duct pressures (0 to 5 kPa above atmosphere) with substantial headroom up to 115 kPa. The 45 mV/kPa sensitivity resolves small duct pressure differentials for VAV (variable air volume) box control and filter-clog detection. The 6-SIP through-hole package is mechanically robust for inside-air-handler installation. Apply a small inline damping restrictor to the port to prevent turbulence-induced noise from high-velocity supply air on the sensor diaphragm.

💊

Medical Respiratory Equipment

The MPX5100A's ±2.5% accuracy and 0 to 85 C compensated range are well-suited to medical CPAP/BiPAP and ventilator pressure monitoring in the 0 to 50 kPa above atmosphere range typical of therapeutic airway pressure. The ratiometric 0.2 V to 4.7 V output simplifies compliance with medical device EMC requirements. The 6-SIP package's through-hole mounting provides a mechanically stable connection that withstands repeated cleaning and patient handling. Validate biocompatibility of the port interface per ISO 10993 if the gas path contacts the patient circuit.

🏭

Industrial Process Control

In industrial process plants, the MPX5100A monitors absolute pressure in sealed tanks, vessels, and vacuum chambers where the measurement must be independent of atmospheric pressure changes. The 4.5 V full-scale span provides high resolution for closed-loop control valves and pressure transmitters. The 10 mA typical supply current and 5 V single-supply operation simplify integration with 4-20 mA loop converters via XTR105-style transmitters. Mount the sensor away from vibration sources and isolate the port tubing with a snubber for noisy pneumatic lines.

🚗

Automotive Manifold Absolute Pressure (MAP) Sensing

The MPX5100A's 0 to 115 kPa absolute range and 0.2 V to 4.7 V output match the classic MAP sensor input range for naturally-aspirated gasoline engine ECUs. The 45 mV/kPa sensitivity gives ECU algorithms sufficient resolution for load calculation at idle, part-throttle, and wide-open-throttle conditions. While newer automotive MPX-series parts are AEC-Q100 qualified, the MPX5100A is widely used in non-safety-critical and hobby ECU applications. Verify AEC-Q100 qualification separately if designing for production automotive safety systems.

🌐

Weather Station / Altimeter

Hobby and prosumer weather stations benefit from the MPX5100A's barometric range and 45 mV/kPa sensitivity, which together with a temperature sensor (e.g., LM35) yield altitude-corrected pressure readings for altimeter functions in handheld GPS devices. The 6-SIP package is straightforward to integrate on a weather-station mainboard alongside an ESP32 or similar Wi-Fi MCU. Apply conformal coating to the PCB to protect the sensor from humidity ingress, and locate the port outside the enclosure wall to sample true ambient pressure.

Récapitulatif des produits recommandés

MPC5554MZP132 Microcontroller for ADC readout and altitude computation Utilisé dans : Barometric Pressure Measurement MPX4115A NXP Semiconductors Utilisé dans : Barometric Pressure Measurement MC9S08QD4CSC NXP Semiconductors Utilisé dans : HVAC Duct Pressure Monitoring MPX5700A NXP Semiconductors Utilisé dans : HVAC Duct Pressure Monitoring K60P144M150SF3RM Kinetis MCU with 16-bit ADC for medical-grade pressure waveform sampling Utilisé dans : Medical Respiratory Equipment MPXV5100G Surface-mount variant for compact medical device PCBs Utilisé dans : Medical Respiratory Equipment LPC1768FBD100 ARM Cortex-M3 MCU with industrial Ethernet for process transmitter Utilisé dans : Industrial Process Control XTR105UA 4-20 mA current loop transmitter IC for industrial signal conditioning Utilisé dans : Industrial Process Control MC9S12C128CFUE Automotive-grade MCU for engine management ECU Utilisé dans : Automotive Manifold Absolute Pressure (MAP) Sensing MPX4250A NXP Semiconductors Utilisé dans : Automotive Manifold Absolute Pressure (MAP) Sensing ESP32-WROOM-32E Espressif Systems Utilisé dans : Weather Station / Altimeter MPL3115A2 Digital altimeter alternative for I2C-based designs Utilisé dans : Weather Station / Altimeter
What is the operating pressure range of MPX5100A?
The MPX5100A measures absolute pressure from 15 kPa to 115 kPa (approximately 2.18 PSI to 16.68 PSI). According to the NXP MPX5100 datasheet, this range corresponds to about 0 to 100 kPa above atmospheric at sea level, covering standard barometric and manifold-absolute-pressure (MAP) sensing needs for both medical and industrial systems.
What is the output voltage range of MPX5100A?
The MPX5100A produces an analog output from 0.2 V to 4.7 V, proportional to absolute pressure. According to the NXP datasheet, the ratiometric output is referenced to the 5 V supply, so the signal scales linearly with VCC, simplifying direct connection to a 5 V microcontroller ADC without additional signal conditioning.
Is the MPX5100A drop-in compatible with the MPX5100AP?
The MPX5100A and MPX5100AP are pin-compatible members of the same NXP MPX5100 series and share the 6-SIP package footprint. The 'AP' suffix indicates a different port orientation (axial port vs. single port), but electrical specifications and pin assignments are functionally identical for absolute-pressure measurement, making them drop-in equivalents on the same PCB.
Where can I buy MPX5100A online?
The MPX5100A is available from major distributors including DigiKey (stock checked 2026-10-15), Mouser, and Octopart-listed resellers. Pricing as of 2026-10-15 starts near $18.50 at qty 1 with significant breaks at qty 100 (~$14.20) and qty 1000 (~$9.95). Lead time for production quantities is generally 4 to 8 weeks.
What is the price of MPX5100A in 1000-piece quantities?
The MPX5100A unit price at qty 1000 is approximately $9.95 as of 2026-10-15, based on distributor listings. Volume pricing scales further down to roughly $7 to $8 per unit at very high volumes through direct NXP sales channels. For exact current quotes, consult DigiKey and Mouser in real time before placing production orders.
What is the lead time for MPX5100A orders?
Lead time for MPX5100A orders is typically 4 to 8 weeks through major distributors as of 2026-10-15. Distributors like DigiKey and Mouser often hold buffer stock for prototype quantities, but production volumes may require placing orders 6 weeks in advance. NXP's direct sales channel can sometimes shorten this for franchise customers.
MPX5100A vs MPX5700A - which is better for HVAC applications?
The MPX5100A measures up to 115 kPa (≈16.7 PSI) with 45 mV/kPa sensitivity, while the MPX5700A measures up to 700 kPa (≈101.5 PSI) with lower sensitivity per kPa. For HVAC duct and low-pressure applications below 100 kPa above atmosphere, MPX5100A provides finer resolution; for high-pressure refrigerant or hydraulic systems, MPX5700A is the better fit.
MPX5100A vs MPX4115A - which should I choose?
The MPX5100A covers 15 to 115 kPa absolute with 0.2 V to 4.7 V output, while the MPX4115A covers 15 to 115 kPa but outputs 0.2 V to 4.8 V and is offered in a different package style. For new designs, MPX5100A is preferred because it has more standardized pinout and broader distributor stock; MPX4115A is typically chosen only for legacy compatibility.
When should I choose MPX5100A over MPX4100A?
The MPX5100A (15-115 kPa absolute, 0.2-4.7 V output) is the right choice when you need full barometric-range measurement with 4.5 V span. The MPX4100A (20-105 kPa absolute, 0.3-4.9 V) is a lower-cost, slightly narrower-range alternative. Choose MPX5100A when altitude/weather accuracy requires the wider pressure span.
What is the best drop-in replacement for MPX5100A?
The best drop-in replacement for MPX5100A is the MPX5100AP, an NXP same-family variant with the identical 6-SIP footprint and electrical specs, differing only in axial port orientation. The MPX5100DP (differential version) is not a drop-in because it requires vented porting. Verify mechanical port orientation before substituting in fielded designs.
Can XGZP6872A replace MPX5100A?
The CFSensor XGZP6872A is a pin-compatible 6-SIP cross-brand drop-in alternative to MPX5100A with similar pressure range and analog interface, marketed specifically as a substitute. While it shares the 6-pin footprint, confirm sensitivity, accuracy, and output voltage range against your ADC reference in the XGZP6872A datasheet before substituting in production.
Where can I download the MPX5100A datasheet PDF?
The official NXP MPX5100 datasheet PDF is available at https://www.nxp.com/docs/en/data-sheet/MPX5100.pdf. The datasheet covers the MPX5100, MPX5100A, MPXV5100G, MPX5100DP, MPX5100GP, and MPX5100AP variants in a single document. Mirror copies are also available on AllDatasheet and DigiChip, but the NXP source is the authoritative version.
Where do I find the MPX5100A pinout?
The MPX5100A pinout is shown in the NXP datasheet (linked above) on the package outline page. The 6-SIP pin assignment from the datasheet is: Pin 1 = VCC (5 V), Pin 2 = VOUT, Pin 3 = GND, Pins 4-6 = Ground/No-Connect (port orientation dependent). Pin 1 is identified by a molded dot on the sensor body.
What are the key specifications of MPX5100A that engineers should know?
The MPX5100A key specifications are: pressure range 15 to 115 kPa absolute (≈2.18 to 16.68 PSI), output 0.2 V to 4.7 V ratiometric, sensitivity 45 mV/kPa, full-scale span 4.5 V, supply 5 V at 10 mA, accuracy ±2.5%, compensated temperature range 0 C to +85 C, and package 6-SIP through-hole. These specs make it a direct fit for barometric and MAP sensing.
What is the operating temperature range of MPX5100A?
The MPX5100A operates and is temperature-compensated over 0 C to +85 C, per the NXP MPX5100 datasheet. The thermal compensation ensures the 0.2 V to 4.7 V output remains accurate across this range. For applications outside this band (e.g., outdoor weather stations in arctic climates), consider the MPX5100A together with external thermal management or a wider-range sensor.

Données de référence d'ingénierie pour MPX5100A — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose MPX5100A when you need a calibrated, temperature-compensated absolute pressure sensor with a 15 to 115 kPa range and 0.2 V to 4.7 V analog output that connects directly to a 5 V microcontroller ADC. It is the right pick for barometric weather stations, altimeters, sealed-vessel pressure monitoring, and HVAC duct sensing. Choose MPX5100DP or MPX5100GP if you need differential/gauge measurement versus ambient, but note the same PCB footprint. Choose MPX5700A for high-pressure (up to 700 kPa) refrigerant or hydraulic applications. Choose the CFSensor XGZP6872A as a third-party cross-brand drop-in only if NXP supply is constrained - verify sensitivity and accuracy against your ADC reference before substituting.

Comparaison avec les alternatives

Paramètre Ce produit MPX5100AP MPX5100DP MPX5100GP MPXV5100G MPX5100AS XGZP6872A
Package 6-SIP Module 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module (variant) - same footprint 6-SIP Module - same 6-SIP Module - same
Brand NXP Semiconductors NXP Semiconductors (same brand) NXP Semiconductors (same brand) NXP Semiconductors (same brand) NXP Semiconductors (same brand) NXP Semiconductors (same brand) CFSensor (cross-brand)
Pressure Type Absolute Absolute Differential Gauge Gauge Absolute Absolute/Gauge selectable
Operating Pressure Range 15 to 115 kPa 15 to 115 kPa 0 to 100 kPa differential 0 to 100 kPa gauge 0 to 100 kPa gauge 15 to 115 kPa 0 to 100 kPa
Output Voltage Range 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.5 V to 4.5 V
Supply Voltage 5.0 V 5.0 V 5.0 V 5.0 V 5.0 V 5.0 V 5.0 V

Principaux différenciateurs

  • Absolute pressure reference (vacuum-sealed) (vs MPX5100DP / MPX5100GP)
  • Wide 4.5 V full-scale output span (vs XGZP6872A)
  • Industry-standard NXP MPX5100 datasheet family (vs MPX4115A)

Notes de conception

Power the MPX5100A from a clean, well-regulated 5 V supply. The ratiometric output is referenced to VCC, so any ripple or noise on the 5 V rail (above ~100 Hz) will couple directly into the pressure reading. Place a 100 nF ceramic decoupling capacitor as close as possible to pin 1 (VCC) and a bulk 10 uF electrolytic at the supply entry point. For ADC-driven designs, average 16 to 64 samples to suppress residual 50/60 Hz pickup while preserving pressure-bandwidth response.

Avoid mechanical stress on the MPX5100A package - never force-bend or twist the leads, and do not apply side load to the sensor body. The piezoresistive die is sensitive to package stress, which can introduce offset errors of several kPa. Mount with the port unobstructed, free of conformal coating ingress, and away from heat sources (linear regulators, power resistors) that could skew the temperature-compensated output. For absolute measurements, ensure the port is sealed from ambient airflow changes that would cause apparent pressure drift.

Route the analog output trace away from switching nodes, digital clocks, and motor drivers. Use a ground guard ring around the output pin and keep the trace under 50 mm if possible. Place an RC low-pass filter (e.g., 1 kΩ + 100 nF, fc ≈ 1.6 kHz) close to the ADC input to attenuate high-frequency noise without meaningfully affecting the sensor's DC and low-frequency pressure response. For high-accuracy barometric work, enable the ADC's internal offset and gain calibration per the MCU reference manual.

Informations de conformité

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Sans plomb
Yes
Sans halogène
Yes
Minerais de conflit
Compliant

RoHS compliant per NXP product page. Not AEC-Q100 qualified - for safety-critical automotive designs, choose a specifically AEC-Q100 qualified MPX-series variant. Halogen-free and lead-free per NXP packaging materials declaration.

Données vérifiées le : 2026-10-15 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MPX5100A MPX5100A datasheet NXP MPX5100A pressure sensor absolute pressure sensor 115 kPa analog 6-SIP pressure sensor module MPX5100A barometric altimeter MPX5100A vs MPX5700A MPX5100A drop-in replacement MPX5100A buy price what is the output voltage of MPX5100A MPX5100A pinout 6-SIP MAP sensor for ECU hobbyist

Composants & termes associés

NXP Semiconductors MPX5100A MPX5100AP MPX5100DP MPX5100GP MPXV5100G MPX4115A MPX5700A XGZP6872A CFSensor absolute pressure sensor piezoresistive transducer MEMS sensor ratiometric output AEC-Q100 RoHS REACH 6-SIP module barometric pressure altimeter MAP sensor HVAC medical respiratory equipment weather station 5 V supply
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ