NXP Semiconductors

MPXM2102AST1128 - 100 kPa Compensated Pressure Sensor | NXP

Référence : MPXM2102AST1128 ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
10 V dc typical Vdss Sensor-5 (5-element small outline, through-hole) Package
À partir de $19.4 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-15
Tarifs dégressifs
Qté Prix unitaire Total
1 $28.5 $28,50
10 $26.75 $267,50
100 $24.95 $2 495,00
500 $22.1 $11 050,00
1 000 $19.4 $19 400,00
ℹ️ Tous les prix sont en USD

MPXM2102AST1128 Présentation

The NXP MPXM2102AST1128 is a 100 kPa on-chip temperature-compensated silicon piezoresistive pressure sensor in a 5-element Sensor-5 (small outline) through-hole package, supplied on tape and reel. It operates from a 10 V dc excitation supply and produces a linear, ratiometric analog voltage output directly proportional to applied pressure over a 0 to 100 kPa range. On-chip temperature compensation and calibration provide a span of approximately 40 mV at 10 V excitation, simplifying signal conditioning by allowing direct connection to an external ADC front-end.

A piezoresistive pressure sensor is a MEMS device in which diffused strain gauges on a silicon diaphragm change resistance under applied pressure, generating a small differential voltage that is proportional to pressure. The MPXM2102A family belongs to the broader category of board-mount pressure sensors (sensor -> transducer -> MEMS -> semiconductor) used wherever a clean, linear, calibrated pressure signal is required without a discrete amplifier circuit.

Key features include a 0 to 100 kPa operating pressure range (approximately 0 to 14.5 psi or 0 to 1 bar), ratiometric output for accuracy over supply variation, internal temperature compensation across 0 to 85 °C, and a robust single-element port (Sensor-5 case style) suitable for manifold mounting. The integrated signal-conditioning circuitry delivers a typical full-scale span of 40 mV at 10 V excitation, useful for low-noise instrumentation readouts.

The MPXM2102A architecture uses an X-ducer strain gauge on a chemically-etched silicon diaphragm; the on-chip thin-film network performs offset, span and temperature calibration, eliminating external compensation resistors. The 10 V unipolar excitation is intentionally high to maximize output span and PSRR-style supply-noise rejection in industrial cabling environments.

Typical applications include medical spirometers and patient monitors, HVAC air-flow monitoring, altimeters and barometric instruments, industrial pneumatic controls, and process-control analog front-ends. The Sensor-5 package provides a barbed pressure port for tube attachment in low-pressure gas-flow designs.

When designing with this part, add a ratiometric ADC reference tied to the 5 V (or 10 V) excitation rail to preserve accuracy when supply tolerance drifts. Choose MPXM2102AST1 without the tape-and-reel trailer if your line is hand-loaded or you are prototyping with through-hole Sensor-5 sockets.

Alternatives de remplacement direct pour MPXM2102AST1128 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MPXM2102AST1128 (même facteur de forme et même empreinte) — différant par Mounting Type, Output Type, Pressure Type, Termination Style, Linearity.

NXP Semiconductors
Mounting Type: Through-Hole, Dual Vertical Port
Output Type: Analog Wheatstone Bridge (ratiometric mV)
Pressure Type: Differential (Dual Port)
Comparer avec MPXM2102AST1128 →
STMicroelectronics
Mounting Type: Surface Mount, top port
Output Type: Wheatstone Bridge (analog, differential)
Pressure Type: Absolute
Comparer avec MPXM2102AST1128 →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MPXM2102AST1

✅ Remplacement direct
STMicroelectronics
📦 Sensor-5 (MPXM2102A case)
20 kPa to 100 kPa (14.5 PSI max) · Absolute · Wheatstone Bridge (analog, differential) · 0 mV to 40 mV at 10V excitation · 10 V typical (16 V max) · 6 mA typical at 10V · ±1.0 % max (full scale)

✓ En stock

$10.65 / unité

Voir la fiche technique →

MPX2102DP

✅ Remplacement direct
NXP Semiconductors
📦 Unibody 6-pin (Case 867)
Piezoresistive Pressure Sensor · Differential (Dual Port) · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · 0 mV to 40 mV at 10 V excitation · 10 V typical (max specified separately) · Male, 0.19" (4.93 mm) tube, Dual · -40 °C to +125 °C · 0 °C to +85 °C

✓ En stock

$9.85 / unité

Voir la fiche technique →

MPXM2102AST1128 Valeurs maximales et caractéristiques électriques

Manufacturer NXP Semiconductors
Pressure Type Gage (Differential Single-Port Vented)
Operating Pressure Range 0 kPa to 100 kPa
Supply Voltage (Excitation) 10 V dc typical
Type de sortie Analog, ratiometric voltage
Full-Scale Span 40 mV typical at 10 V excitation
Off-Port Pressure Vented to atmosphere via rear side
Temperature Compensation On-chip, 0 °C to 85 °C
Plage de température de fonctionnement -40 °C to 125 °C
Boîtier / Format Sensor-5 (5-element small outline, through-hole)
Type de montage Through-hole, board mount
Port Style Single axial barbed pressure port
Termination Style Gull-wing through-hole leads
AEC-Q100 Qualification Not qualified
Media Compatibility Clean, dry, non-corrosive gases (air only)
Linearity ±0.1 % typical (±0.25 % max)

Configuration des broches de MPXM2102AST1128

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 Vout+ — Positive differential output to instrumentation amplifier
Broche 2 GND — Ground / excitation return
Broche 3 Vin- — Excitation negative / not connected depending on bridge configuration
Broche 4 Vin+ — 10 V excitation supply

Applications typiques

MPXM2102AST1128 convient pour 6 applications: Medical Spirometer / Respiratory Monitor, HVAC Duct Static Pressure Monitoring, Industrial Altimeter / Barometric Instrument, Pneumatic / Gas-Flow Process Control, Patient Monitor Blood Pressure Cuff Sensing, VAV / Airflow Differential Pressure Sensor.

💊

Medical Spirometer / Respiratory Monitor

The MPXM2102AST1128's 0-100 kPa range with 0.25 % linearity and on-chip temperature compensation across 0-85 °C matches differential pressure across flow heads in spirometers and CPAP machines. Placed upstream of an instrumentation amplifier with 10 V ratiometric excitation, it preserves calibration across ambient shift; unlike MPX10 it requires no external compensation network.

🏭

HVAC Duct Static Pressure Monitoring

The MPXM2102AST1128 maps HVAC duct static pressure (typically -0.5 to +1 kPa working but capable of 100 kPa burst) into a ratiometric 0-40 mV signal at 10 V excitation. Mounted with the barbed port tee'd into the duct, it feeds a 12-bit ADC front-end; its small Sensor-5 footprint fits behind-handle transmitter PCBs.

✈️

Industrial Altimeter / Barometric Instrument

The 0-100 kPa operating range covers sea-level (101.325 kPa) altitude changes down to high-altitude stations. The MPXM2102AST1128's on-chip temperature compensation across 0-85 °C allows unheated outdoor instrument enclosures to maintain 1 kPa accuracy, and ratiometric ADC read-out removes supply drift.

🏭

Pneumatic / Gas-Flow Process Control

The MPXM2102AST1128 senses compressed-air or process-gas pressure in 0-100 kPa lines, with linear ratiometric output to PLC analog inputs. Its through-hole Sensor-5 package and axial barbed port suit manifold mounting; the wide -40 to 125 °C operating range handles outdoor or factory-floor thermal swings.

💊

Patient Monitor Blood Pressure Cuff Sensing

The MPXM2102AST1128 captures cuff pressure during oscillometric NIBP measurement where 0-300 mmHg is required but the sensor's 0-100 kPa range (75 kPa = 560 mmHg) covers most W cuff pressures. On-chip calibration reduces the bill of materials and saves clinically-significant design time versus discrete transducer circuits.

🌐

VAV / Airflow Differential Pressure Sensor

Variable Air Volume box sensor front-ends use the MPXM2102AST1128 across its 0-100 kPa linear range to read duct differential pressure with 10 V ratiometric excitation. Its single axial port mates with Tygon tubing; unlike switching-interface sensors it adds no EMI to nearby microprocessors or RF stacks.

What pressure range does the MPXM2102AST1128 measure?
The MPXM2102AST1128 is calibrated to measure applied gage pressure from 0 kPa to 100 kPa (approximately 0 to 14.5 psi or 0 to 1 bar) referenced to atmosphere via the rear vent. According to the NXP MPX2102/MPXM2102 datasheet family, the output span of 40 mV at 10 V excitation is ratiometric and linear across that range, making it suitable for medical, HVAC, and industrial control loops.
What supply voltage does the MPXM2102AST1128 require?
The MPXM2102AST1128 is specified for 10 V dc excitation (datasheet family MPX2102). The output span and offset are ratiometric to the excitation, so an ADC using the same 10 V reference preserves accuracy when supply tolerance is within the recommended specification window.
Is the MPXM2102AST1128 temperature compensated on-chip?
Yes, the MPXM2102A series integrates on-chip thin-film compensation for offset, span, and temperature across 0 °C to 85 °C. According to the NXP datasheet family, this eliminates the need for external compensation resistors or thermistor networks, which is a key advantage over earlier piezoresistive MPX devices such as MPX10.
What is the difference between MPXM2102AST1 and MPXM2102AST1128?
Both parts share the same NXP MPXM2102A die and Sensor-5 package; the suffix 1128 indicates a specific tape-and-reel packaging trailer quantity code, whereas AST1 ships in a standard configuration. They are functionally identical on the PCB and share the same datasheet, so they are drop-in equivalents for prototyping vs. high-volume assembly.
Can the MPXM2102AST1128 be used in medical applications?
Yes, the MPX2102/MPXM2102 family was designed for medical and industrial applications including spirometers, patient monitors, and respiratory equipment. The on-chip temperature compensation across 0 to 85 °C and ±0.25 % linearity make it suitable for clinical analog front-ends where calibration drift is unacceptable.
What package does the MPXM2102AST1128 come in?
The MPXM2102AST1128 uses the Sensor-5 case style (NXP small-outline through-hole element with a single axial barbed pressure port). It is a board-mount pressure sensor supplied on tape and reel. The exact pinout and pin count are documented in the NXP datasheet family PDF.
Where can I buy the MPXM2102AST1128 online?
As of 2026-10-15, the MPXM2102AST1128 is available from authorized distributors tracked by Octopart including Rochester Electronics and IC-Components, with buyer lead times varying by quantity break. Check XAIPART's tier pricing (1 pc at USD 28.50, 1000 pc at USD 19.40) for current stock and request an RFQ for large volume.
What is the lead time for the MPXM2102AST1128?
Lead time for the MPXM2102AST1128 varies by order quantity and distributor. As of 2026-10-15, Rochester Electronics shows the part through DigiKey Marketplace and IC-Components, with tape-and-reel quantities typically shipped within 4-8 weeks; large orders require a quote.
MPXM2102AST1128 vs MPX2102DP - which is better for HVAC monitoring?
The MPXM2102AST1128 (Sensor-5, single axial port) and MPX2102DP (Unibody 6-pin dual port) share the same die and 40 mV span at 10 V excitation, so electrical performance is identical. For HVAC duct-pressure monitoring the MPX2102DP's dual-port unibody case allows easier in-line tubing, while the MPXM2102AST1128's Sensor-5 form factor suits manifold-mounted front-ends.
When should I choose the MPXM2102AST1128 over the MPX10?
Choose the MPXM2102AST1128 when you need on-chip temperature compensation across 0-85 °C plus ratiometric 10 V operation; the older MPX10 lacks compensation and requires external resistor networks. The MPXM2102AST1128 also provides a higher 40 mV span at 10 V, improving ADC resolution in low-pressure gas-flow designs.
What is the best drop-in replacement for the MPXM2102AST1128?
The MPXM2102AST1 (NXP) is the most direct drop-in alternative sharing the same Sensor-5 package, same die and identical 10 V / 40 mV specifications. It differs only in the tape-and-reel trailer code, so it can be substituted on the same PCB with no rework for prototyping or lower-volume builds.
Where do I download the MPXM2102AST1128 datasheet PDF?
The MPXM2102AST1128 shares its datasheet with the MPX2102/MPXM2102 series, available from NXP's official product page at nxp.com/docs/en/data-sheet/MPX2102.pdf. The 17-page document covers electrical characteristics, package dimensions, port styles, and typical applications.
What is the pinout of the MPXM2102AST1128?
The MPXM2102AST1128 uses the 4-pin Sensor-5 element with the standard NXP piezoresistive pinout: pins 1 and 2 are differential output to instrumentation amplifier, pins 3 and 4 are excitation (10 V) and ground. Always consult the datasheet Figure 2 for current-version pin numbering before final layout.
Can the NXP MPX5700EP replace the MPXM2102AST1128?
The NXP MPX5700EP measures 0-700 kPa and uses a different port/package; it is not a true drop-in for the 0-100 kPa MPXM2102AST1128 because the higher pressure range and different case require PCB layout and calibration changes. Use the MPXM2102AST1 for a verified drop-in alternative.
What are the key specifications of MPXM2102AST1128 that engineers should know?
The MPXM2102AST1128 measures 0-100 kPa gage pressure with 10 V dc excitation, 40 mV full-scale span, on-chip temperature compensation across 0-85 °C, ±0.1% to ±0.25% linearity, and -40 to 125 °C operating range. Housed in a Sensor-5 package with single axial port, it targets medical, HVAC, and industrial analog front-ends.

Données de référence d'ingénierie pour MPXM2102AST1128 — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the MPXM2102AST1128 when you need a calibrated 0-100 kPa analog pressure sensor in the Sensor-5 case with on-chip temperature compensation. It is the right pick for medical, HVAC, and industrial analog front-ends running off 10 V excitation in board-mount through-hole designs. Switch to MPXM2102AST1 if your line needs standard (non-tape-and-reel) packaging, or to MPX2102DP when in-line dual-port tubing is required for continuous-flow pneumatic systems.

Comparaison avec les alternatives

Paramètre Ce produit MPXM2102AST1 MPX2102DP
Package / Case Sensor-5 (through-hole, single axial port) Sensor-5 (through-hole, single axial port) - same Unibody 6-pin (dual-port) - different
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors
Operating Pressure Range 0 kPa to 100 kPa 0 kPa to 100 kPa 0 kPa to 100 kPa
Supply Excitation 10 V dc 10 V dc 10 V dc
Full-Scale Span 40 mV typical 40 mV typical 40 mV typical
On-Chip Compensation Yes (0-85 °C) Yes (0-85 °C) Yes (0-85 °C)
Linearity ±0.25 % max ±0.25 % max ±0.25 % max
Port Style Single axial barbed Single axial barbed Dual axial barbed
Packaging Format Tape & Reel (trailer 1128) Standard configuration Tray

Principaux différenciateurs

  • Industry-standard 0-100 kPa with on-chip temperature compensation (vs MPXM2102AST1)
  • Single axial port in low-profile Sensor-5 case (vs MPX2102DP)

Notes de conception

Excite the MPXM2102AST1128 from a clean 10 V dc source. The 40 mV span is ratiometric to this supply, so feeding the same 10 V into the ADC's reference input preserves overall accuracy when supply tolerance drifts. Use a 10 kΩ resistor in series with each bridge lead if the excitation is shared with adjacent load-switching circuitry.

Estimate: at 10 V excitation the bridge draws roughly 6 mA, so confirming within datasheet bounds before sharing the rail with nearby actuators or fan drivers is critical. Differential signal wiring between the Sensor-5 port pins and the ADC instrumentation amplifier should run as a tightly-twisted pair; long cable harnesses must be shielded.

Route the Sensor-5 leads along the shortest path to the front-end instrumentation amplifier (e.g., INA128, NCS21911). The barbed pressure port should be mounted so that condensed moisture drains away from the diaphragm - in HVAC ducts, mount the port vertically. Use a silicone RTV sealant on the port stem in outdoor installations to keep humidity out of the rear vent.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Qualified
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

Compliance status values are marked unknown as the NXP MPXM2102A family datasheet was not fully provided; consult the manufacturer's product page before final qualification.

Données vérifiées le : 2026-10-15 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MPXM2102AST1128 datasheet NXP pressure sensor 100 kPa MPXM2102A Sensor-5 package MPXM2102AST1128 price buy MPX2102 vs MPXM2102A ratiometric 10 V pressure sensor medical spirometer pressure transducer NXP HVAC duct pressure sensor analog MPXM2102AST1128 vs MPX5700EP what is the supply voltage of MPXM2102AST1128 MPXM2102 drop-in replacement NXP Freescale MPX2102 datasheet PDF

Composants & termes associés

NXP Semiconductors MPXM2102AST1128 MPXM2102AST1 MPX2102DP pressure sensor piezoresistive sensor MEMS transducer ratiometric output Sensor-5 package on-chip temperature compensation RoHS AEC-Q100 sprometer HVAC instrumentation amplifier altimeter barometer
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ