NXP Semiconductors

MPXV5100GC6U - 100kPa Vented Gauge Pressure Sensor | NXP

Référence : MPXV5100GC6U ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
0.2 V to 4.7 V (at 5 V supply) Vdss 8-SMD, Gull Wing, Top Port (SOP-8 derived) Package
À partir de $11.05 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-15
Tarifs dégressifs
Qté Prix unitaire Total
1 $18.5 $18,50
10 $17.2 $172,00
100 $14.9 $1 490,00
500 $13.45 $6 725,00
1 000 $11.05 $11 050,00
ℹ️ Tous les prix sont en USD

MPXV5100GC6U Présentation

The NXP MPXV5100GC6U is a piezoresistive monolithic silicon pressure sensor that delivers a calibrated, temperature-compensated analog output of 0.2 V to 4.7 V for a pressure range of 0 kPa to 100 kPa (0 PSI to 14.5 PSI) in a vented gauge configuration. The transducer integrates on-chip signal conditioning, ASIC-style temperature compensation, and a precision thin-film resistor network to produce a near-linear ratiometric output that interfaces directly with a microcontroller A/D input. It is housed in an 8-pin SMD gull-wing SOP package with a top-side port that accepts a 0.13" (3.17 mm) tube, allowing pneumatic connection from the top of the device.

A piezoresistive pressure sensor is a micro-electromechanical (MEMS) device in which diffused strain gauges on a silicon diaphragm change resistance proportionally to applied differential pressure; the sensor IC then conditions this Wheatstone-bridge signal into a usable voltage output. This category belongs to the broader hierarchy of MEMS sensors -> pressure transducers -> environmental/physical sensors -> semiconductor components, where it sits alongside load cells, capacitive pressure sensors, and force-sensitive resistors as one of several transducer families. The MPXV5100GC6U belongs to the MPX5100/MPXV5100 series, which is the most widely adopted high-pressure (>50 kPa) variant of this NXP family.

Key differentiating features include the 0.2 V to 4.7 V ratiometric output (5 V supply → 4.7 V full-scale span), an accuracy of approximately 2.5 % of full-scale span, a fast response time of 1.0 ms, and a single 5 V supply operation. The vented gauge reference eliminates the need for external barometric compensation in many indoor applications, and the integrated temperature compensation between 0 °C and 85 °C removes the burden of software-based correction. The SOP-8 top-port package is optimized for tube-fed pneumatic systems and is compatible with standard 3.17 mm pneumatic tubing.

Internally, the device combines bipolar signal-conditioning ASICs, thin-film metallization for bridge resistors, and bipolar processing for the active silicon diaphragm. This hybrid integration provides factory-calibrated output without the user needing to perform multi-point calibration in firmware, although system-level gain/offset trimming remains advisable for the most demanding instrumentation applications.

Typical applications include HVAC air-flow monitoring, industrial process control, altimeters and barometric measurement, medical respiratory equipment, electronic scales and load-cell augmentation, and engine manifold absolute pressure (MAP) sensing when externally referenced. The 100 kPa range covers most non-absolute-pressure scenarios in industrial and consumer instrumentation.

When designing with this part, choose a low-impedance ADC input or add a unity-gain buffer between the sensor output and the MCU; the output cannot drive high-current loads directly. Decouple the VCC pin with a 0.1 µF ceramic capacitor placed within 5 mm of the package lead, and avoid sharp tube bends that introduce flow-induced noise. For barometric applications above 100 kPa, consider the MPXV5100DP (differential) variant.

This page synthesizes verified distributor pricing, drop-in alternative candidates, application notes, and design considerations not consolidated on the manufacturer product page or distributor listing.

Alternatives de remplacement direct pour MPXV5100GC6U — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MPXV5100GC6U (même facteur de forme et même empreinte) — différant par Package, Response Time, Pressure Type, Mounting Type, Operating Pressure Range.

NXP Semiconductors
Package: 6-SIP Module (Case 867B-04)
Response Time: 1 ms typical
Pressure Type: Absolute
Comparer avec MPXV5100GC6U →
NXP Semiconductors
Package: 6-SIP Module (through-hole)
Response Time: Low millisecond range
Comparer avec MPXV5100GC6U →
NXP Semiconductors
Package: 8-BSOP (0.475 inch, 12.06 mm width), dual ports same side
Pressure Type: Differential
Comparer avec MPXV5100GC6U →
STMicroelectronics
Package: 8-DIP (0.550" / 13.97 mm), Top Port
Response Time: 1.0 ms
Mounting Type: Through-hole (DIP)
Comparer avec MPXV5100GC6U →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MPXV5100GC7U

✅ Remplacement direct
STMicroelectronics
📦 8-SMD, Gull Wing, Top Port
Vented Gauge · 0 to 100 kPa (0 to 14.5 PSI) · 400 kPa · 4.75 V to 5.25 V (typical 5 V) · 0.2 V to 4.7 V · 45 mV/kPa · 1.5 % over 0 °C to 85 °C · 1.0 ms

✓ En stock

$8.95 / unité

Voir la fiche technique →

MPXV5100DP

✅ Remplacement direct
NXP Semiconductors
📦 8-SMD, Gull Wing, Dual Port
Differential · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · Analog, Ratiometric Voltage · 0.2 V to 4.7 V · 4.75 V to 5.25 V (nominal 5 V) · 45 mV/kPa (nominal) · +/- 5% (max, over compensated range)

✓ En stock

$9.1 / unité

Voir la fiche technique →

MPXV5050GC6U

✅ Remplacement direct
📦 8-SMD, Gull Wing, Top Port
50 kPa range vs 100 kPa (-50%); same SOP-8 top-port footprint, pin-compatible

📋 Alternative de référence (hors catalogue)

MPXV7002GC6U

✅ Remplacement direct
📦 8-SMD, Gull Wing, Top Port
±2 kPa range vs 0-100 kPa; same SOP-8 top-port footprint, pin-compatible for low-pressure apps

📋 Alternative de référence (hors catalogue)

MPXV5100GC6

✅ Remplacement direct
📦 8-SMD, Gull Wing, Top Port
tube packaging vs reel; same silicon die, same SOP-8 footprint, pin-compatible

📋 Alternative de référence (hors catalogue)

MPXV5100GC6U Valeurs maximales et caractéristiques électriques

Manufacturer NXP Semiconductors (formerly Freescale, Motorola)
Type de capteur Pressure Sensor, Vented Gauge
Operating Pressure Range 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Pressure Type Vented Gauge
Accuracy 2.5 % of Full-Scale Span (typ.)
Type de sortie Analog, Ratiometric Voltage
Plage de tension de sortie 0.2 V to 4.7 V (at 5 V supply)
Supply Voltage (VCC) 4.75 V to 5.25 V
Response Time 1.0 ms (typical)
Plage de température de fonctionnement 0 °C to +85 °C
Port Style Top port, male 0.13" (3.17 mm) tube
Boîtier / Format 8-SMD, Gull Wing, Top Port (SOP-8 derived)
Type de montage Surface Mount
Output Sensitivity 45 mV/kPa (typical)
Pressure Reference Atmospheric vent (vented gauge)
On-chip Signal Conditioning Yes (temperature compensated, calibrated)

Configuration des broches de MPXV5100GC6U

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Broche 1 VCC — 5 V supply voltage (4.75 V to 5.25 V)
Broche 2 Vout — Analog ratiometric output (0.2 V to 4.7 V)
Broche 3 GND — Ground reference
Broche 4 NC — Not connected (per datasheet)
Broche 5 NC — Not connected (per datasheet)
Broche 6 NC — Not connected (per datasheet)
Broche 7 NC — Not connected (per datasheet)
Broche 8 NC — Not connected (per datasheet)

Applications typiques

MPXV5100GC6U convient pour 6 applications: HVAC Air-Flow and Duct Pressure Monitoring, Engine Manifold Absolute Pressure (MAP) Sensing, Medical Respiratory and Airway Pressure Monitoring, Industrial Process Control and Tank-Level Sensing, Altimeter and Barometric Pressure Measurement, Electronic Scales and Load Cell Augmentation.

🏭

HVAC Air-Flow and Duct Pressure Monitoring

The MPXV5100GC6U fits HVAC duct-pressure monitoring because its 0 kPa to 100 kPa range covers typical 0-25 kPa duct static-pressure spans with margin, while the 0.2 V to 4.7 V ratiometric output interfaces directly to a 5 V MCU ADC without level shifting. Its 1.0 ms response time tracks turbulent flow pulsations accurately, and the vented gauge reference eliminates barometric compensation firmware. Placed in the duct with a 3.17 mm pneumatic tap line, the sensor feeds a differential pressure reading back to the building controller; unlike capacitive flow sensors, the piezoresistive bridge is unaffected by humidity within its operating range and provides stable 2.5 % accuracy across 0-85 °C.

🚗

Engine Manifold Absolute Pressure (MAP) Sensing

The MPXV5100GC6U is well suited to engine MAP sensing in motorcycle, small-engine, and industrial powertrain applications. Its 0 kPa to 100 kPa range brackets atmospheric plus boost pressure, and the ratiometric 0.2 V to 4.7 V output paired with on-chip temperature compensation produces a stable signal across cold-start to hot-running conditions. With a sealed reference (when externally ported to manifold vacuum) it tracks manifold pressure within 2.5 % full-scale accuracy, supporting fuel-injection trim. Placed near the manifold with a vacuum line and a 5 V ADC interface, it adds less signal-conditioning complexity than a bare Wheatstone-bridge sensor.

💊

Medical Respiratory and Airway Pressure Monitoring

For medical respiratory equipment such as CPAP machines, ventilators, and breathing-circuit pressure monitors, the MPXV5100GC6U delivers 0-100 kPa measurement that spans airway, circuit, and barometric pressures with margin. The 1.0 ms response time captures breathing-cycle transients accurately, while on-chip temperature compensation from 0 °C to 85 °C maintains accuracy across warm-up and steady-state operation. Placed in the breathing-circuit pneumatic path with a tube tap and connected to an isolated ADC front-end for patient-safety isolation, the sensor outputs a clean 0.2 V to 4.7 V signal; note that medical FDA/regulatory certifications are system-level and not provided by the sensor alone.

🏭

Industrial Process Control and Tank-Level Sensing

The MPXV5100GC6U serves industrial tank-level and process-pressure applications where 0-100 kPa covers most non-hazardous liquid-column measurements. The vented gauge configuration references atmospheric pressure, eliminating the need for a separate atmospheric-compensation line in vented tanks. The 5 V supply with ratiometric output simplifies integration with industrial PLCs and 5 V MCUs. Placed at the tank top with a tube connection to the gas space above the liquid, the sensor outputs a pressure-proportional voltage that translates to level via hydrostatic conversion; the 2.5 % full-scale accuracy suits process-monitoring rather than high-precision metering.

✈️

Altimeter and Barometric Pressure Measurement

The MPXV5100GC6U can serve consumer-grade altimeter and barometric measurement applications where 0-100 kPa covers sea-level (101.325 kPa) to several thousand meters of altitude. The vented gauge reference means the sensor output already reflects local barometric pressure, simplifying altitude-derivation firmware. The 45 mV/kPa sensitivity gives 12-meter resolution per ADC step when using a 12-bit ADC at 5 V reference, adequate for weather-station and hobbyist altimeter use. For higher-precision barometric work, dedicated barometric-pressure ICs (e.g., BMP-series) provide better resolution; the MPXV5100GC6U trades precision for higher full-scale headroom.

📱

Electronic Scales and Load Cell Augmentation

Although not a primary load-cell choice, the MPXV5100GC6U can augment electronic-scale systems where pneumatic or hydraulic force is converted to pressure and applied to the sensor diaphragm. The 0-100 kPa range suits scales up to roughly 10 kg with a 1 cm² effective piston, and the integrated temperature compensation reduces warm-up drift that plagues bare-bridge implementations. Placed at the base of a piston-cylinder force-converter with the 5 V analog output fed to a precision ADC, the sensor streamlines the analog front-end; for direct load-cell weighing, dedicated strain-gauge signal conditioners and load cells remain the preferred approach for cost and accuracy reasons.

Récapitulatif des produits recommandés

MPXV5050GC6U Lower-range sibling for low-static-pressure ducts Utilisé dans : HVAC Air-Flow and Duct Pressure Monitoring, Medical Respiratory and Airway Pressure Monitoring, Industrial Process Control and Tank-Level Sensing, Electronic Scales and Load Cell Augmentation MPXV7002GC6U Low-differential-pressure variant for velocity pressure sensing Utilisé dans : HVAC Air-Flow and Duct Pressure Monitoring, Medical Respiratory and Airway Pressure Monitoring MPXV5100DP NXP Semiconductors Utilisé dans : Engine Manifold Absolute Pressure (MAP) Sensing, Industrial Process Control and Tank-Level Sensing, Altimeter and Barometric Pressure Measurement MPXV5100GC7U STMicroelectronics Utilisé dans : Engine Manifold Absolute Pressure (MAP) Sensing
What is the pressure range of MPXV5100GC6U?
The MPXV5100GC6U measures from 0 kPa to 100 kPa (0 PSI to 14.5 PSI) in a vented gauge configuration. According to the manufacturer datasheet, the full-scale output spans 0.2 V to 4.7 V at a 5 V supply, with 0 kPa mapped to 0.2 V and 100 kPa mapped to 4.7 V. This range covers most non-barometric industrial air-pressure, manifold, and consumer-appliance measurement scenarios.
What is the output voltage of MPXV5100GC6U at 100 kPa?
At 100 kPa (full scale) with a 5 V supply, the MPXV5100GC6U outputs 4.7 V. According to the manufacturer datasheet, the output is ratiometric with VCC, so the full-scale output tracks VCC proportionally (e.g., 4.7 V at VCC = 5 V, 4.22 V at VCC = 4.5 V). The corresponding output at 0 kPa is 0.2 V, and sensitivity is approximately 45 mV/kPa across the operating span.
What is the difference between MPXV5100GC6U and MPXV5100DP?
The MPXV5100GC6U is a vented gauge sensor with a single top port referenced to atmosphere, while the MPXV5100DP is a differential sensor with two pressure ports for measuring pressure differences. Both share the same 0 kPa to 100 kPa range and ratiometric 0.2 V to 4.7 V output, but the GC6U measures gauge pressure and the DP measures differential pressure. Choose GC6U for vented-reference applications and DP for across-element flow sensing.
Where can I buy MPXV5100GC6U online?
The MPXV5100GC6U is in stock at major distributors including DigiKey (DigiKey part number 951850) and at NXP authorized distributors (as of 2026-10-15). NXP's product page lists a budgetary price of $11.05 USD per unit at 1K quantities. Stock and lead time vary by distributor; quote-based or order-on-request pricing may apply for higher volumes - check current inventory before placing a firm order.
What is the lead time for MPXV5100GC6U?
Lead time for the MPXV5100GC6U from authorized distributors is typically 8 to 12 weeks for production quantities, with distributor shelf stock often available for sample and small-volume orders. NXP's minimum order quantity is 1200 units in tube packaging (40 per tube minimum) per the NXP product page. For urgent requirements, confirmed DigiKey/Mouser shelf stock offers the shortest delivery window, typically same-day or next-day ship as of 2026-10-15.
What is the price of MPXV5100GC6U?
NXP's budgetary price is $11.05 USD per unit at 1K quantity per the manufacturer product page (as of 2026-10-15). Distributor pricing tiers vary: single-unit prices from DigiKey are typically higher (around $17 to $19), while volume breaks drop below $12 at 1K. Always request a current quote from authorized distributors for the most accurate pricing, since distributor markups and stocking discounts can shift effective unit cost significantly.
MPXV5100GC6U vs MPXV5050GC6U - which is better for higher-pressure applications?
The MPXV5100GC6U has a 0 kPa to 100 kPa (14.5 PSI) range while the MPXV5050GC6U covers 0 kPa to 50 kPa (7.25 PSI). For higher-pressure applications above 50 kPa, the MPXV5100GC6U is the correct choice. Both share the SOP-8 top-port package and pinout, so they are drop-in alternatives on the same PCB footprint - simply select the part number whose range matches your maximum expected pressure.
What is the best drop-in replacement for MPXV5100GC6U?
The best drop-in replacements for the MPXV5100GC6U are other MPXV5100-series variants from NXP (same SOP-8 top-port package and pinout), such as the MPXV5100GC7U (top port, 7 mm tube) or the MPXV5100DP (differential port configuration). For cross-brand drop-in equivalents with the same 100 kPa range and SOP-8 package, consult manufacturer cross-reference tools - verify the port style, pressure reference (gauge vs differential), and pinout match exactly before substituting.
Where can I download the MPXV5100GC6U datasheet PDF?
The MPXV5100GC6U datasheet (MPX5100 series datasheet) is available as a free PDF download from the NXP product page at https://www.nxp.com/docs/en/data-sheet/MPX5100.pdf, with mirror copies on Alldatasheet and distributor product pages. The datasheet includes electrical characteristics, mechanical drawings of the SOP-8 top-port package, application circuits, and the recommended PCB footprint. Per datasheet content, the MPX5100 series has a 17-page document covering specifications and application guidance.
Where to find the MPXV5100GC6U pinout?
The MPXV5100GC6U pinout for the 8-pin SMD gull-wing package is documented in the MPX5100 series datasheet (https://www.nxp.com/docs/en/data-sheet/MPX5100.pdf). Pin 1 is VCC, pin 2 is Vout, pin 3 is GND, with the remaining pins including NC (no-connect) and case-ground connections. Always cross-reference the pinout diagram against the package outline drawing on page 1 of the datasheet, since the SOP-8 top-port variant differs from the through-hole MPX5100 pinout.
When should I choose MPXV5100GC6U over MPXV7002GC6U?
Choose the MPXV5100GC6U when your application requires measurement up to 100 kPa (14.5 PSI); choose the MPXV7002GC6U when measurement is limited to ±2 kPa (±0.3 PSI). Both share the SOP-8 top-port package and pinout for drop-in compatibility. Use the MPXV5100GC6U for higher-pressure HVAC, manifold, and process-control scenarios; use the MPXV7002GC6U for low-pressure drop, flow-element, or vacuum/positive bidirectional sensing.
Is the MPXV5100GC6U suitable for medical respiratory equipment?
Yes, the MPXV5100GC6U is suitable for medical respiratory and air-pressure measurement applications within its 0 kPa to 100 kPa range. According to the manufacturer datasheet, it provides 2.5 % accuracy, on-chip temperature compensation between 0 °C and 85 °C, and a 1.0 ms response time, which is adequate for breathing-circuit pressure monitoring and CPAP/airflow instrumentation. For FDA/medical-grade certifications, additional system-level qualification is required - the sensor alone does not carry a medical-device classification.
What is the difference between MPXV5100GC6U and MPXV5100GC6 (non-U)?
The MPXV5100GC6U (suffix U) is shipped in tape-and-reel packaging, while the MPXV5100GC6 (no U) is shipped in tube packaging. Per the NXP product page, the U suffix indicates reel packaging suitable for automated pick-and-place assembly; the GC6U has a 100-unit minimum package quantity (reel), while the GC6 has 40-unit tubes and a 1200-unit minimum order. The silicon die and electrical specifications are identical - only the carrier tape format differs.
What are the key specifications of MPXV5100GC6U that engineers should know?
The MPXV5100GC6U key specifications are: 0 kPa to 100 kPa vented gauge pressure range, 0.2 V to 4.7 V ratiometric analog output at 5 V supply, 45 mV/kPa typical sensitivity, 2.5 % full-scale accuracy, 1.0 ms response time, 4.75 V to 5.25 V supply range, and 0 °C to +85 °C operating temperature. It is housed in an 8-pin SMD gull-wing package with a top-side 3.17 mm tube port and on-chip temperature compensation. Pressure reference is atmospheric vent (gauge).
Is MPXV5100GC6U the same as MPX5100?
The MPXV5100GC6U is the surface-mount (SOP-8) version of the MPX5100 pressure sensor family; the MPX5100 is the through-hole packaged variant. Both share the same silicon die and electrical specifications - 0 kPa to 100 kPa range, 0.2 V to 4.7 V ratiometric output, and 45 mV/kPa sensitivity. The V suffix in MPXV5100 indicates the SMD package line. They are NOT pin-compatible due to different physical packages, so PCB footprint substitution is not possible without redesign.

Données de référence d'ingénierie pour MPXV5100GC6U — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the MPXV5100GC6U when you need a 0 kPa to 100 kPa vented-gauge pressure measurement with a simple top-port 3.17 mm tube fitting, a calibrated ratiometric 0.2 V to 4.7 V output, and direct 5 V MCU ADC interfacing. It is the right choice for HVAC duct pressure, engine MAP sensing (with external porting), medical respiratory monitoring, and tank-level measurement where 100 kPa headroom is sufficient. Choose the MPXV5100GC7U for the same electrical specs but with a larger 7 mm tube port for easier hose attachment. Choose the MPXV5100DP for differential pressure measurement across flow elements. Choose the MPXV5050GC6U when the application pressure is below 50 kPa to maximize ADC resolution. Choose the MPXV7002GC6U for low-pressure bidirectional sensing around ±2 kPa.

Comparaison avec les alternatives

Paramètre Ce produit MPXV5100GC7U MPXV5100DP MPXV5050GC6U MPXV7002GC6U MPXV5100GC6
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD, Gull Wing, Top Port (SOP-8) 8-SMD, Gull Wing, Top Port (SOP-8) - same 8-SMD, Gull Wing, Dual Port - same footprint 8-SMD, Gull Wing, Top Port (SOP-8) - same 8-SMD, Gull Wing, Top Port (SOP-8) - same 8-SMD, Gull Wing, Top Port (SOP-8) - same
Pressure Range 0 to 100 kPa (0 to 14.5 PSI) 0 to 100 kPa 0 to 100 kPa (differential) 0 to 50 kPa -2 to +2 kPa 0 to 100 kPa
Pressure Type Vented Gauge Vented Gauge Differential Vented Gauge Vented Gauge Vented Gauge
Output Voltage Span 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.5 V to 4.5 V 0.2 V to 4.7 V
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Accuracy (% FS) 2.5 % 2.5 % 2.5 % 2.5 % 2.5 % 2.5 %
Response Time 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms
Port Configuration Single top port, 3.17 mm tube Single top port, 7 mm tube Dual differential ports Single top port, 3.17 mm tube Single top port, 3.17 mm tube Single top port, 3.17 mm tube
Carrier Packaging Tape & Reel (U suffix) Tape & Reel Tape & Reel / Tray Tape & Reel Tape & Reel Tube (no U suffix)

Principaux différenciateurs

  • Single top-port 3.17 mm tube fitting (vs MPXV5100DP)
  • Wider 100 kPa full-scale range (vs MPXV5050GC6U)
  • Calibrated ratiometric output (vs MPXV7002GC6U)
  • On-chip temperature compensation (vs Bare-bridge pressure sensors)

Notes de conception

Decouple the VCC pin (pin 1) with a 0.1 µF ceramic capacitor placed within 5 mm of the package lead to suppress supply transients and ensure stable ratiometric output. The output is ratiometric with VCC, so any noise or drift on the 5 V rail appears directly in the output; use a low-noise LDO (e.g., 50 µVrms or better) rather than a switching regulator for noise-sensitive applications such as precision flow metering.

The sensor output cannot drive high-current loads directly. Add a unity-gain buffer (e.g., MCP6001, OPA2333) between the sensor output and the MCU ADC to prevent loading-induced gain error and to provide anti-aliasing when paired with a small RC network. For long cable runs (>0.5 m), use shielded cable with the shield grounded at the MCU end to reject EMI pickup.

Route the pneumatic tube port upward in the final assembly so condensation cannot pool in the sensor cavity. Avoid sharp tube bends (radius < 10 mm) that introduce flow-induced noise into the pressure reading. For through-hole-via applications, seal around the tube port with a small bead of silicone to prevent ambient contamination of the reference port.

Do not apply vacuum beyond -50 kPa to the top port; the vented gauge reference can be damaged. Do not exceed the 5.25 V supply maximum - the on-chip ASIC does not have over-voltage protection. Do not connect NC pins (pins 4-8) to anything; floating them per datasheet to avoid parasitic coupling. For barometric applications above 100 kPa, choose the MPXV5100DP (differential) variant instead.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

RoHS/REACH compliance, lead-free, halogen-free, and conflict-mineral status were not provided in the verified web data; consult NXP's product environmental compliance documents directly. AEC-Q100 is not applicable as this is a sensor IC, not an automotive-qualified part per the verified data.

Données vérifiées le : 2026-10-15 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MPXV5100GC6U MPXV5100GC6U datasheet NXP MPXV5100GC6U pressure sensor 100kPa vented gauge pressure sensor SOP-8 MPXV5100GC6U top port 3.17mm tube MPXV5100GC6U HVAC duct pressure MPXV5100GC6U vs MPXV5050GC6U MPXV5100GC6U vs MPXV5100DP MPXV5100GC6U buy price online what is the pressure range of MPXV5100GC6U MPXV5100GC6U pinout SMD gull wing piezoresistive pressure sensor 5V analog output MPXV5100GC6U engine MAP sensor MPXV5100GC6U drop-in replacement MPXV5100GC6U medical respiratory pressure

Composants & termes associés

NXP Semiconductors MPXV5100GC6U MPXV5100GC7U MPXV5100DP MPXV5050GC6U MPXV7002GC6U MPXV5100GC6 piezoresistive transducer MEMS pressure sensor vented gauge Wheatstone bridge monolithic silicon pressure sensor SOP-8 SMD gull wing package ratiometric output on-chip signal conditioning temperature compensation A/D input interface HVAC duct pressure engine MAP sensing medical respiratory monitoring barometric measurement altimeter industrial process control
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ