ams OSRAM

SFH 7070 - BIOFY PPG Biomonitoring Sensor Module | ams OSRAM

Référence : SFH 7070 ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
7.5 mm x 3.9 mm x 0.9 mm Package
Contact pour connaître le prix
MOQ : 1 |
Prix mis à jour : 2026-10-11
Tarifs dégressifs
Qté Prix unitaire Total
1 $0 $0,00
10 $0 $0,00
100 $0 $0,00
500 $0 $0,00
1 000 $0 $0,00
ℹ️ Tous les prix sont en USD

SFH 7070 Présentation

The ams OSRAM SFH 7070 is a BIOFY™ reflective biomonitoring sensor module featuring two green LED emitters and one photodetector in a single multi-chip package measuring 7.5 mm x 3.9 mm x 0.9 mm, optimized for strong photoplethysmography (PPG) signal acquisition in wearable devices.

A reflective optical biosensor module integrates light emitters and a photodetector on one substrate so that light reflected from human skin — modulated by blood volume changes — can be measured without a transmissive finger clip. Within the sensing hierarchy, the SFH 7070 belongs to the optical sensor -> photoplethysmography sensor -> biometric/biomonitoring module class, sitting above discrete LEDs and photodiodes and below complete vital-sign signal processor ICs.

Key features include an integrated light barrier that blocks optical crosstalk between the emitters and detector, ESD robustness of 2 kV according to ANSI/ESDA/JEDEC JS-001 (HBM, Class 2), and a wide 120-degree beam angle that maximizes returned PPG signal over skin. The green emission wavelength is well absorbed by hemoglobin and penetrates shallowly, which is ideal for wrist-worn heart-rate tracking because it suppresses motion artifacts compared with infrared.

Technically, the multi-chip construction places two green emitters flanking the detector chip behind the optical barrier, allowing the designer to drive both emitters sequentially or in parallel to increase photon flux into dark or highly pigmented skin, improving SNR of the AC PPG component. Surface-mount termination supports standard reflow assembly on flexible or rigid PCBs, and the low profile of 0.9 mm suits slim smartwatch enclosures.

Typical applications include wrist heart-rate monitors, fitness bands, smartwatches, and medical-grade pulse-oximetry-adjacent biomonitoring patches where strong green PPG signals are required.

When designing with the SFH 7070, drive the LEDs with low-noise constant-current pulses and time-synchronize sampling of the detector with emission windows to reject ambient light; verify the datasheet for absolute maximum current ratings per emitter.

This page synthesizes distributor availability data, datasheet-derived specifications, alternatives analysis, and practical design notes not found in the manufacturer datasheet alone.

Alternatives de remplacement direct pour SFH 7070 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

SFH 7072

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 [DATA_NEEDED: package]
newer-generation BIOFY variant with different internal chip layout; verify package compatibility before use

📋 Alternative de référence (hors catalogue)

SFH 7060

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 [DATA_NEEDED: package]
earlier heart-rate module variant, different emitter/detector configuration and package geometry

📋 Alternative de référence (hors catalogue)

SFH 7050

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 [DATA_NEEDED: package]
compact BIOFY pulse-sensor variant, smaller package, fewer emitters

📋 Alternative de référence (hors catalogue)

SFH 7070 Valeurs maximales et caractéristiques électriques

Product Type Reflective optical biomonitoring sensor module (BIOFY)
Configuration Two green emitters + one detector (multi-chip)
Package Size (W x D x H) 7.5 mm x 3.9 mm x 0.9 mm
Beam Angle 120 degrees
Optical Crosstalk Control Integrated light barrier
ESD Rating 2 kV (HBM, Class 2, ANSI/ESDA/JEDEC JS-001)
Type de montage Surface Mount
Termination Solder
Package Style 6-SMD, no lead
Température de fonctionnement -40C to +85C
Signal Optimization Strong PPG signal
Application Biomonitoring / photoplethysmography (PPG)

Guide de configuration des broches du SFH 7070 6-smd, no lead

Configuration des broches du SFH 7070 (boîtier 6-smd, no lead). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.

Schéma de brochage du boîtier 6-smd, no lead pour le SFH 7070

Aucune donnée de brochage détaillée disponible pour SFH 7070.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

SFH 7070 convient pour 6 applications: Wrist-Worn Heart Rate Monitoring, Fitness Bands and Activity Trackers, Smartwatch Optical Heart-Rate Arrays, Medical-Grade Biomonitoring Patches, Wearable SpO2-Adjacent Pulse Sensing Research, Industrial and IoT Proximity-Based Biometrics.

📱

Wrist-Worn Heart Rate Monitoring

The SFH 7070 fits wrist heart-rate monitoring because its dual green emitters produce a strong PPG signal through shallow skin layers where capillary blood-volume modulation is most visible, and its 120-degree beam angle captures a wide return cone from curved wrist geometry. In a typical smartwatch stack, the module sits against the skin on the PCB underside; emitters are pulsed sequentially while the detector output feeds a transimpedance amplifier and ADC synchronized to the emission windows. The integrated light barrier prevents direct emitter-to-detector leakage that would otherwise mask the microvolt-level AC PPG component. Driving both emitters alternately rejects ambient light and improves motion-artifact immunity, at the cost of roughly doubling LED power versus single-emitter drive.

🏋️

Fitness Bands and Activity Trackers

For fitness bands, the SFH 7070 offers a compact 7.5 mm x 3.9 mm x 0.9 mm footprint and surface-mount termination compatible with flexible PCB assembly, which matters because band housings are thinner and more curved than watch bodies. The strong PPG signal optimization helps at lower LED currents, directly extending battery life — the dominant constraint in continuous heart-rate tracking. The -40C to +85C operating range withstands outdoor athletic use and body-temperature extremes. Designers should drive the emitters with short duty-cycled current pulses (typically a few percent) and use the light-barrier-isolated detector path with ambient-light subtraction sampling during LED-off windows to keep SNR high while minimizing average power consumption.

⏱️

Smartwatch Optical Heart-Rate Arrays

In smartwatch multi-channel vital-sign arrays, several SFH 7070 modules are placed around the watch back to sample multiple wrist locations, improving robustness against strap looseness and motion. Each module's integrated crosstalk barrier simplifies dense optical layouts that would be impractical with discrete LEDs and photodiodes. The ESD rating of 2 kV HBM Class 2 (per ANSI/ESDA/JEDEC JS-001) supports manufacturing handling, though assembly should still occur at ESD-protected stations. Performance considerations include cross-talk between adjacent modules — time-division multiplexing of each module's emitters and per-channel synchronous detection are the standard techniques to keep channels independent within the duty-cycle budget.

💥

Medical-Grade Biomonitoring Patches

Adhesive biosensor patches for continuous patient monitoring use the SFH 7070 as the optical front end for pulse-rate measurement, benefiting from its optimized strong PPG output on varied skin tones through the dual-emitter drive scheme. The -40C to +85C range covers sterilization-adjacent and transport conditions, and solder termination survives flexing when mounted on polyimide flex circuits. System designers must add their own LED drivers, low-noise analog front end, and compliance electronics since the module provides only the optical path. Note that using the SFH 7070 in a medical product requires the manufacturer to complete IEC-level system qualification; ams OSRAM supports field returns with failure analysis (FAR) processes for quality management.

🧪

Wearable SpO2-Adjacent Pulse Sensing Research

Research prototypes exploring pulse waveform analysis, blood-pressure estimation from pulse transit time, and perfusion-index algorithms use the SFH 7070 because its repeatable, factory-aligned optical geometry produces more reproducible signals than hand-assembled discrete optical benches. The two green emitters can be driven at different currents to probe different effective penetration depths, giving researchers a simple depth-sensitivity knob within one package. Acquisition is typically performed at 25-500 Hz with 16-bit or higher ADC resolution to capture the AC PPG morphology. The main trade-off is the green-only wavelength set: infrared or red wavelengths needed for classic SpO2 ratio-of-ratios require additional discrete emitters alongside the module.

🏭

Industrial and IoT Proximity-Based Biometrics

Beyond consumer wearables, the SFH 7070's strong green PPG output serves niche industrial uses such as driver-monitoring touch points, authentication grips, and operator-presence detection on machinery handles, where contact PPG both confirms presence and can derive pulse rate. The -40C to +85C industrial temperature range and 2 kV HBM ESD class 2 rating suit factory-floor electrical environments, while the light-barrier construction keeps performance stable against housing tolerances. Designers should account for ambient green-light interference from industrial lighting by using synchronized sampling and LED-off background subtraction. The 0.9 mm height allows embedding into metal or plastic housings with a simple optical window and opaque gasket for ambient light exclusion.

What is the SFH 7070 and what does it measure?
The SFH 7070 is an ams OSRAM BIOFY™ reflective optical sensor module for biomonitoring, containing two green LED emitters and one photodetector in one multi-chip package. It measures photoplethysmography (PPG) signals — blood-volume changes in skin — used to derive heart rate and pulse waveform in wearable devices such as smartwatches and fitness bands.
What are the key specifications of the SFH 7070 that engineers should know?
The SFH 7070 integrates two green emitters and one detector behind an integrated light barrier that blocks optical crosstalk. The package measures 7.5 mm x 3.9 mm x 0.9 mm, offers a 120-degree beam angle, is ESD rated to 2 kV HBM Class 2 per ANSI/ESDA/JEDEC JS-001, and operates from -40C to +85C. It is optimized for strong PPG signal output in wrist-worn biomonitoring applications.
Where can I download the SFH 7070 datasheet PDF?
The official SFH 7070 datasheet PDF (16 pages, approximately 760 KB) is available from ams OSRAM at look.ams-osram.com and is mirrored on datasheet aggregators such as Alldatasheet and Octopart. According to the ams OSRAM datasheet, the document covers electrical characteristics, optical performance, package dimensions, and application guidance for the BIOFY sensor module.
Why does the SFH 7070 use green emitters instead of infrared?
Green light is strongly absorbed by hemoglobin and penetrates only shallowly into skin, which yields a high-contrast PPG signal at the wrist while rejecting motion artifacts better than infrared. According to ams OSRAM, the SFH 7070 is specifically optimized for a strong PPG signal, and the dual-emitter arrangement increases photon flux into darker or more pigmented skin to improve signal-to-noise ratio.
How does the SFH 7070 block optical crosstalk between emitters and detector?
The SFH 7070 uses an integrated light barrier built into the package that optically isolates the two green emitters from the detector chip. Per the ams OSRAM datasheet, this barrier prevents emitted light from reaching the detector directly, forcing detection of only skin-reflected photons — this is essential because direct leakage would swamp the microvolt-level AC PPG component of interest.
What is the difference between the SFH 7070 and the SFH 7060?
Both are ams OSRAM BIOFY™ multi-chip reflective sensor modules, but the SFH 7070 uses two green emitters plus one detector and is optimized for strong wrist PPG signals, while the SFH 7060 is an earlier heart-rate variant with a different chip configuration and package geometry. They are not pin-compatible, so always verify the current package drawing before substituting one for the other in an existing PCB design.
What is the best drop-in replacement for the SFH 7070?
No verified cross-brand pin-to-pin replacement for the SFH 7070 appears in distributor cross-reference data as of 2026-10-11. Within the ams OSRAM family, SFH 7072 and SFH 7060 are related BIOFY variants, but package dimensions and internal chip layouts differ, so any substitution requires PCB rework and requalification. For production continuity, source the original SFH 7070 or consult ams OSRAM for a recommended successor part.
SFH 7070 vs SFH 7072 — which is better for wrist heart-rate monitoring?
The SFH 7070 is the module optimized specifically for strong PPG signals at the wrist with its dual green emitter and light-barrier construction. The SFH 7072 is a newer-generation variant that may offer multi-wavelength options, but its package and pinout differ. For existing boards designed around the 7.5 mm x 3.9 mm x 0.9 mm SFH 7070 footprint, staying with the SFH 7070 avoids redesign; for new designs, compare both datasheets on SNR and power figures.
When should I choose the SFH 7070 over a discrete LED plus photodiode solution?
Choose the SFH 7070 when board space, assembly simplicity, and optical alignment dominate the design. The multi-chip package pre-aligns the two green emitters and detector behind a light barrier, eliminating the manual optical isolation engineering required with discrete parts. Discrete solutions give wavelength flexibility but require careful crosstalk control; the SFH 7070 delivers a repeatable, factory-aligned optical path at 7.5 mm x 3.9 mm footprint.
Is the SFH 7070 suitable for medical-grade vital-sign devices?
The SFH 7070 provides the optical front end (emitters and detector) for PPG measurement and operates from -40C to +85C, making it usable in medical-grade biomonitoring products. However, module-level use does not confer medical device approval — system-level IEC 60601 qualification, algorithm development, and validation are the responsibility of the device manufacturer. ams OSRAM provides complaint management and failure analysis (FAR) support for the product.
What is the ESD rating of the SFH 7070?
The SFH 7070 is ESD rated at 2 kV according to ANSI/ESDA/JEDEC JS-001 under the Human Body Model, Class 2, per the ams OSRAM datasheet. Because green LEDs are inherently ESD-sensitive, handle the module at ESD-protected workstations, use grounded wrist straps, and consider series current-limiting in the driver circuit for additional robustness in field conditions.
What is the operating temperature range of the SFH 7070?
The SFH 7070 operates from -40C to +85C, according to distributor datasheet summaries sourced from ams OSRAM. This range covers consumer wearables, industrial monitoring patches, and most medical wearable environments, but note that LED luminous efficiency and detector dark current drift with temperature, so PPG algorithm gain compensation across the full range is recommended.
What is the price of the SFH 7070?
Exact unit pricing for the SFH 7070 was not available in the verified data as of 2026-10-11; Octopart lists the part across up to 8 distributors, so live pricing should be checked at DigiKey, Octopart, or Component Search Engine. Optical biosensor modules of this class typically range from a few dollars to around ten dollars at quantity 1, but treat that as context, not a quoted price — request a quote (RFQ) for firm figures.
Is the SFH 7070 in stock and where can I buy it online?
The SFH 7070 is listed by distributors including DigiKey (as ams OSRAM AG part SFH 7070, 6-SMD no-lead package), Octopart, Win Source, and Component Search Engine as of 2026-10-11. Live stock quantities fluctuate, so check DigiKey or Octopart for real-time availability; Win Source also accepts RFQ for volume orders. Lead time is typically distributor-dependent and should be confirmed at order time.
How should the SFH 7070 be driven in a PPG circuit?
Drive the two green emitters with pulsed constant-current sources synchronized to detector sampling windows, alternating between emitters to reject ambient light and motion artifacts. Place the detector output into a transimpedance amplifier with low-noise biasing. Estimated: keep LED duty cycles low (a few percent) to limit junction heating and battery drain — typical wearable PPG duty cycles are 1-10%. Consult the ams OSRAM datasheet for absolute maximum forward current before finalizing drive levels.

Données de référence d'ingénierie pour SFH 7070 — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the SFH 7070 when you need a factory-aligned, crosstalk-isolated green PPG optical front end for wrist-worn heart-rate or biomonitoring products where strong signal on varied skin tones is the priority and the 7.5 mm x 3.9 mm footprint is acceptable. Choose the compact SFH 7050 when board area is the binding constraint and slightly weaker signal can be tolerated. Choose the SFH 7060 if your design targets the older heart-rate module footprint or needs multi-wavelength emission. There is no verified cross-brand drop-in equivalent as of 2026-10-11, so redesign risk applies to any substitution. For new designs, also evaluate the newer SFH 7072 generation against the SFH 7070 on SNR, power, and package dimensions before committing the PCB layout.

Comparaison avec les alternatives

Paramètre Ce produit SFH 7072 SFH 7060 SFH 7050
Brand ams OSRAM ams OSRAM ams OSRAM ams OSRAM
Primary Application Strong PPG signal for wrist biomonitoring Next-gen biomonitoring Heart-rate monitoring Compact pulse sensing

Principaux différenciateurs

  • Dual green emitters for stronger PPG signal (vs SFH 7060)
  • Integrated optical crosstalk barrier (vs Discrete LED + photodiode builds)
  • Slim 0.9 mm profile (vs SFH 7050)

Notes de conception

Drive the two green emitters with pulsed constant-current sources and time-synchronize the detector sampling to the emission windows. Use an LED-off sampling window to capture ambient light and subtract it from the on-samples. The AC PPG component is small relative to the DC skin-reflection component, so the transimpedance amplifier should use low-bias-current input stages and a gain plan that avoids saturating on the DC term. Alternating between the two emitters also helps decorrelate motion artifacts.

The SFH 7070 is a surface-mount 6-SMD no-lead module at 7.5 mm x 3.9 mm x 0.9 mm; follow the ams OSRAM recommended land pattern exactly to preserve optical alignment between the on-board light barrier and the housing aperture. Use an opaque gasket or housing boss around the module to exclude ambient light paths that bypass the optical window. Green LEDs are ESD-sensitive — despite the 2 kV HBM Class 2 rating, assemble at ESD-protected stations with grounded tooling.

Do not assume pin compatibility with other BIOFY family modules (SFH 7060, SFH 7050, SFH 7072) — package dimensions and internal chip placement differ, and a socketed substitution will misalign the optical path. Also verify absolute maximum forward current per emitter in the ams OSRAM datasheet before sizing the LED driver; exceeding it degrades light output permanently. Finally, plan temperature compensation: LED efficiency and detector dark current both drift across the -40C to +85C range.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

ESD classification per ANSI/ESDA/JEDEC JS-001 (HBM, Class 2) is specified in the datasheet. RoHS/REACH status was not present in the verified data and must be confirmed from the ams OSRAM product page.

Données vérifiées le : 2026-10-11 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

SFH 7070 datasheet SFH 7070 price ams OSRAM SFH 7070 BIOFY sensor SFH 7070 green PPG sensor module SFH 7070 heart rate sensor wearable SFH 7070 vs SFH 7060 SFH 7070 equivalent replacement buy SFH 7070 optical sensor what is SFH 7070 photoplethysmography sensor reflective optical biosensor 7.5mm package SFH 7070 ESD rating HBM class 2 wearable PPG sensor module design

Composants & termes associés

ams OSRAM OSRAM Opto Semiconductors SFH 7070 SFH 7072 SFH 7060 SFH 7050 BIOFY reflective optical sensor photoplethysmography PPG biomonitoring sensor multi-chip package ANSI/ESDA/JEDEC JS-001 HBM Class 2 green LED emitter photodetector surface mount 6-SMD no lead wearable electronics heart-rate monitoring RoHS light barrier
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ