ADM3491EARZ - 3.3V Full-Duplex RS-485/RS-422 Transceiver | Analog Devices
MPN: ADM3491EARZ ⚠ רכישה אחרונהADM3491EARZ סקירה
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into balanced differential transmissions and receives those transmissions back into logic-level signals. Differential signaling improves noise immunity and allows communication over longer cables than single-ended interfaces. The RS-485 standard supports multipoint bus arrangements, while RS-422 provides a dedicated driver-to-receiver relationship.
The ADM3491EARZ operates from a single 3.3 V supply and supports full-duplex communication. Its ±15 kV ESD protection is intended to improve robustness against electrostatic discharge encountered on industrial wiring. The 12 Mbps maximum signaling rate supports high-speed data links, although the usable rate over an installed cable also depends on cable length, impedance, topology, termination, and transceiver characteristics.
This device belongs to Analog Devices' ADM3491E family of low-power RS-485 and RS-422 transceivers. The family supports communication on multipoint bus transmission lines and complies with TIA/EIA RS-485 and RS-422 requirements. Full-duplex operation separates the transmit and receive paths, allowing simultaneous bidirectional traffic without sharing the same pair of bus conductors.
Typical uses include industrial control links, factory automation equipment, building automation, instrumentation, and embedded systems that connect a controller to a remote transceiver over a balanced cable. A full-duplex implementation generally uses separate differential pairs for transmission and reception, together with appropriate cable termination at the physical ends of each pair.
Designers should confirm receiver and driver enable polarity, bus topology, termination, and protection requirements against the manufacturer datasheet. The external circuit should also provide stable 3.3 V decoupling, controlled driver transitions, and a return path for the differential signals.
This product page combines lifecycle information, interface specifications, compatible replacement candidates, and practical bus-design guidance to support component selection and PCB implementation for RS-485 and RS-422 systems.
חלופות תחליף ישיר עבור ADM3491EARZ — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם ADM3491EARZ (אותו גורם צורה וטביעת רגל) — שונים ב Package, Duplex Mode, Bus Configuration, Maximum Data Rate.
ADM3491AR-1
✅ Drop-In ⚠️ מפרטים לא מאומתים📋 חלופה להתייחסות (לא בקטלוג)
ADM3491AR
✅ Drop-In ⚠️ מפרטים לא מאומתיםצור קשר לקבלת מחיר
הצג גיליון נתונים ←MAX3491CSD+
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
MAX3491ECSD+
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
SP3076EEN-L
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
ADM3491EARZ מפרטים
| מתח אספקה | 3.3 V |
| Interface Standard | TIA/EIA RS-485 and TIA/EIA RS-422 |
| Transceiver Configuration | 1 transmitter and 1 receiver |
| Duplex Mode | Full duplex |
| Maximum Data Rate | 12 Mbps |
| ESD Protection | ±15 kV |
| Low-Power Operation | Low-power transceiver with shutdown mode |
| Supply Architecture | Single +3.3 V supply |
| מארז | 14-pin SOIC, 3.90 mm width |
| סוג הרכבה | Surface mount |
| Bus Configuration | Multipoint bus transmission line |
| Driver Enable Control | DE/RE control |
| סטטוס RoHS | Compliant |
| REACH Status | Compliant |
| Halogen-Free Status | Compliant |
מדריך תצורת פינים של ADM3491EARZ 14-pin soic, 3.90 mm width
תצורת פינים עבור ADM3491EARZ (מארזת 14-pin soic, 3.90 mm width). מספרי פינים, פונקציות ותרשימי חיבורים מוגדרים ב-Datasheet של היצרן. יש לעיין בו לקבלת ה-footprint המדויק והנחיות הלחמה.
אין נתוני פריסת פינים מפורטים עבור ADM3491EARZ.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
ADM3491EARZ מתאים עבור 6 יישוםs: Industrial Control Communications, Factory Automation Equipment, Building Automation Networks, Instrumentation and Test Systems, Embedded Serial Bus Gateways, Industrial Data Acquisition.
Industrial Control Communications
The ADM3491EARZ fits full-duplex industrial control links that require a 3.3 V RS-485 or RS-422 interface. Its 12 Mbps maximum data rate provides ample link margin for controller-to-peripheral traffic, while ±15 kV ESD protection improves robustness at connector-facing circuitry. The full-duplex architecture uses separate transmit and receive paths, allowing simultaneous command and response traffic. The main design consideration is ensuring that cable impedance, termination, transceiver enable sequencing, and grounding satisfy the operating distance of the installed bus.
מומלץ
Factory Automation Equipment
The ADM3491EARZ can connect factory automation controllers, remote I/O modules, and production equipment over balanced wiring. Its single 3.3 V supply simplifies integration with modern embedded control logic, and its full-duplex configuration permits continuous status reporting without sharing a conductor pair with command transmission. The ±15 kV ESD rating is particularly relevant around externally accessible equipment cables. Engineers should still assess industrial noise, ground-loop behavior, surge requirements, and connector placement, because transceiver protection does not replace a complete system-level protection strategy.
מומלץ
Building Automation Networks
The ADM3491EARZ suits low-power building automation nodes that exchange balanced data between controllers, sensors, gateways, and remote panels. Its 3.3 V operation and shutdown capability support compact, power-conscious equipment, while the 12 Mbps signaling rate accommodates common automation message traffic. Full-duplex operation simplifies designs that need independent request and response paths. The board should use controlled cable routing and appropriate termination to reduce reflections and noise coupling, particularly where automation wiring runs near motors, lighting systems, and switching power equipment.
מומלץ
Instrumentation and Test Systems
The ADM3491EARZ is suitable for test and measurement instruments that distribute commands or collect data from remote fixtures over a balanced bus. The transceiver's 12 Mbps maximum rate supports fast data exchange, while full-duplex communication allows a controller to issue commands and receive results concurrently. Differential signaling helps preserve data integrity in environments containing switching converters and other noise sources. Designers should select cable length, baud rate, and termination as a coordinated system, and should verify that every device on the bus shares compatible electrical limits.
מומלץ
Embedded Serial Bus Gateways
The ADM3491EARZ can bridge a low-speed embedded processor to an RS-485 or RS-422 field bus. A 3.3 V processor can typically share the transceiver's supply rail, reducing level-shifting requirements, while the full-duplex interface supports simultaneous host commands and peripheral responses. The 12 Mbps capability allows a gateway to participate in faster links when the physical installation supports that rate. Firmware should coordinate driver-enable and receiver-enable signals, and the PCB should keep the transceiver close to the connector and bus routing.
מומלץ
Industrial Data Acquisition
The ADM3491EARZ fits distributed data-acquisition networks that connect measurement electronics to a central controller. Balanced differential signaling improves noise immunity over longer cable runs, and the 12 Mbps maximum rate supports rapid collection of synchronized or high-volume data. Full-duplex operation lets acquisition nodes transmit samples while receiving configuration commands. For reliable deployment, match the baud rate to cable length, place termination only where required by the bus topology, provide a continuous signal-reference path, and review grounding so that voltage offsets do not exceed receiver limits.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור ADM3491EARZ — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | ADM3491AR-1 | ADM3491AR | MAX3491CSD+ | MAX3491ECSD+ | SP3076EEN-L |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | MaxLinear |
| Package | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC |
מבדילים עיקריים
- Documented high-rate full-duplex operation (לעומתADM3491AR-1)
- Explicit ±15 kV ESD-protection positioning (לעומתMAX3491CSD+)
- Single 3.3 V power operation with shutdown (לעומתSP3076EEN-L)
הערות תכנון
Place the ADM3491EARZ close to the external connector and route the balanced driver and receiver pairs as tightly coupled traces with a continuous reference plane. Keep the differential impedance consistent across the board and avoid routing the bus over split planes or noisy switching-converter areas. Since the device is a 3.3 V full-duplex transceiver, provide local supply decoupling and keep enable-control traces away from the high-speed differential outputs.
Select the signaling rate as a function of total bus length, cable impedance, topology, node count, and the transceiver's receiver and driver characteristics. A 12 Mbps transceiver capability does not guarantee 12 Mbps operation over every cable. Use balanced cable, proper termination at the physical ends of the line, controlled driver transitions, and a common signal-reference path. Verify reflections, attenuation, common-mode range, and logic thresholds using the complete board configuration.
Do not substitute a candidate solely because it uses a 14-pin SOIC footprint. Before replacing ADM3491EARZ, compare DE and RE polarity, receiver enable behavior, shutdown behavior, supply limits, driver-output limits, receiver common-mode range, ESD rating, and every no-connect or alternate-function pin. Also check that the replacement supports the required full-duplex behavior and bus-standard application rather than only offering a similar data rate.
Keep the transceiver's differential traces away from antennas, switching nodes, high-current inductors, and isolated power-converter loops. Maintain a compact ground-return path and use the driver-enable and receiver-enable controls so the unused transmitter is disabled when system timing allows it. When a cable leaves the enclosure, combine appropriate board-level protection with the transceiver's ±15 kV ESD capability; ESD protection does not replace overvoltage, surge, or secondary-protection design.
מידע על תאימות
RoHS, REACH, and halogen-free compliance are stated in the component catalog information. AEC-Q100 qualification is not stated and is recorded as not applicable; no separate lead-free or conflict-minerals declaration was available.