Texas Instruments

ADS1271IPW - 24-Bit 105kSPS Delta-Sigma ADC | Texas Instruments | Industrial Measurement

MPN: ADS1271IPW ✓ פעיל
4.75 V Vdss 16-pin TSSOP (PW) Package
כמות הזמנה מינימלית: 1 |

ADS1271IPW סקירה

The Texas Instruments ADS1271IPW is a 24-bit, single-channel sigma-delta analog-to-digital converter (ADC) with a maximum data rate of 105 kSPS, offered in a 16-pin TSSOP (PW) package and specified from -40 °C to +105 °C. It is designed for wide-bandwidth industrial measurement where both DC accuracy and AC performance across an extended temperature range matter.

An ADC is the analog-to-digital converter, the device that turns a continuous voltage into a numeric code. The ADS1271 belongs to the delta-sigma (sigma-delta) sub-family: a high-order, chopper-stabilized modulator samples the input many times per output word, and an on-board decimation filter removes both modulator noise and out-of-band signal energy. Within the broader hierarchy, this part is a data-converter IC, that is, an integrated circuit in the interface IC class, sitting between a sensor or transducer and a digital processor.

Key features include 24-bit resolution, a 105 kSPS maximum conversion rate, a single differential input channel, an SPI-compatible serial interface, and three selectable operating modes that let the designer trade speed against resolution and power. The chopper-stabilized modulator keeps drift low over the industrial temperature range, while the internal decimation filter suppresses out-of-band noise so external analog filtering can be minimized. A supply of approximately 4.75 V is indicated by the distributor part data.

Technically, the ADS1271 combines a high-order modulator with an integrated FIR decimation filter and a chopper-stabilized front end. Three operating modes allow optimization of speed, resolution, and power dissipation, which lets a single design cover very different sampling needs. The result is an input stage usable directly with bridge sensors, thermocouple-style millivolt sources, and wide-dynamic-range industrial front ends without an external instrumentation amplifier.

Typical applications include precision industrial process measurement, strain and load-cell bridges, vibration and condition monitoring, laboratory and test instrumentation, medical monitoring equipment, and low-rate high-resolution data acquisition such as temperature and pressure logging.

A key design consideration is the decimation filter: the usable bandwidth and the noise performance are set by the selected operating mode, so the digital filter and averaging implemented in the host processor must match the data rate actually configured. Layout practice also matters for the differential input pair.

This page consolidates the manufacturer datasheet and product-page parameters, distributor availability references, a parameter-by-parameter comparison against same-footprint TI converters, and practical design notes covering layout, filtering and pitfall avoidance that are not written out in the datasheet itself.

חלופות תחליף ישיר עבור ADS1271IPW — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.

וריאנטים בסדרה זו

דגמים מאותה סדרה התואמים Drop-in עם ADS1271IPW (אותו גורם צורה וטביעת רגל) — שונים ב Number of Channels, Operating Temperature Range, Package, Architecture, Maximum Sampling Rate.

Texas Instruments
Number of Channels: 11 input (10-ch multiplexed inputs per Mouser listing)
Operating Temperature Range: -40C to +125C
Package: 28-pin TSSOP (PW)
השווה עם ADS1271IPW →
Cirrus Logic Inc.
Number of Channels: Single
Operating Temperature Range: -40C to +85C (automotive grade)
Package: 24-pin TSSOP
השווה עם ADS1271IPW →
Cirrus Logic Inc.
Number of Channels: Single
Operating Temperature Range: -40C to +85C (automotive grade)
Package: 24-pin TSSOP
השווה עם ADS1271IPW →

ADS1272IPW

✅ Drop-In ⚠️ מפרטים לא מאומתים
📦 TSSOP-16 (PW)
same 16-pin TSSOP footprint and 24-bit / 105 kSPS class, but different decimation-filter and operating-mode details; data rate span differs from the ADS1271

📋 חלופה להתייחסות (לא בקטלוג)

ADS1262IPW

✅ Drop-In ⚠️ מפרטים לא מאומתים
Texas Instruments
📦 TSSOP-16 (PW)
32 bit · 11 input (10-ch multiplexed inputs per Mouser listing) · Sigma-Delta (Delta-Sigma), 1x modulator · 38.4 kSPS · Yes · Yes · Internal fault monitors · SPI-compatible serial interface

צור קשר לקבלת מחיר

הצג גיליון נתונים ←

ADS1245IPWR

✅ Drop-In ⚠️ מפרטים לא מאומתים
📦 TSSOP-16 (PW)
same 16-pin TSSOP footprint and 24-bit sigma-delta core, but data rate of about 10 kSPS versus 105 kSPS (-90%); suited to slow, high-resolution measurement

📋 חלופה להתייחסות (לא בקטלוג)

ADS1246IPWR

✅ Drop-In ⚠️ מפרטים לא מאומתים
📦 TSSOP-16 (PW)
same 16-pin TSSOP footprint and 24-bit sigma-delta core, with a lower conversion rate and different filter configuration than the ADS1271

📋 חלופה להתייחסות (לא בקטלוג)

ADS1271IPWR

✅ Drop-In
📦 TSSOP-16 (PW)
identical die and pinout, tape-and-reel orderable for automated pick-and-place assembly; electrical ratings unchanged

📋 חלופה להתייחסות (לא בקטלוג)

ADS1271IPW דירוגים מרביים ומאפיינים חשמליים

ADC Type Sigma-Delta (Delta-Sigma) ADC
רזולוציה 24 bit
Number of Channels 1 channel
Maximum Conversion Rate 105 kSPS
Architecture High-order, chopper-stabilized modulator with on-board decimation filter
Operating Modes 3 selectable modes (speed / resolution / power optimization)
ממשק SPI serial interface
מארז 16-pin TSSOP (PW)
סוג הרכבה Surface mount
טווח טמפרטורת פעולה -40 °C to +105 °C
Supply Voltage (nominal) 4.75 V

מדריך תצורת פינים של ADS1271IPW 16-pin tssop (pw)

תצורת פינים עבור ADS1271IPW (מארזת 16-pin tssop (pw)). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.

תרשים פינים של מארזת 16-pin tssop (pw) עבור ADS1271IPW

אין נתוני פריסת פינים מפורטים עבור ADS1271IPW.

עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.

יישומים טיפוסיים

ADS1271IPW מתאים עבור 6 יישוםs: Precision Load Cell and Strain Gauge Front Ends, Industrial Process and Sensor Instrumentation, Vibration and Condition Monitoring, Test and Measurement Instrumentation, Medical and Health Monitoring Equipment, Data Acquisition and Environmental Logging.

🏭

Precision Load Cell and Strain Gauge Front Ends

The ADS1271IPW suits strain-bridge measurement because its 24-bit resolution and chopper-stabilized modulator resolve the few-millivolt differential signals produced by load cells while holding drift low across the -40 °C to +105 °C industrial range. At the 105 kSPS maximum data rate the on-board decimation filter removes modulator and out-of-band noise, so the host processor receives words that are already usable for force calibration. Connect the differential input pair to the bridge with shielded, symmetry-matched traces, reference the converter to a clean source and digital-filter in firmware to match the configured operating mode. The trade-off versus a slower 10 kSPS converter is that wider bandwidth is available for transient or dynamic weighing, at the cost of higher power and lower averaging per sample.

🌐

Industrial Process and Sensor Instrumentation

For temperature, pressure and level loops, the ADS1271IPW combines 24-bit resolution with an SPI interface that can be daisy-chained or polled from a microcontroller, leaving the analog front end simple and compact. The 16-pin TSSOP (PW) package fits tight instrument enclosures, and the wide industrial temperature range covers unheated cabinets and outdoor installations. Use the device in a slower operating mode for near-DC thermocouple-class signals where the decimation filter averages away noise, and switch to a faster mode for vibration or flow transients. Because the digital filter bandwidth follows the selected mode, configure the host digital filter and averaging to the same rate to avoid aliasing artefacts.

🔧

Vibration and Condition Monitoring

Condition-monitoring nodes need wide bandwidth without giving up DC stability, which is exactly where the ADS1271IPW sits: the 105 kSPS maximum data rate captures vibration and impact features, while the chopper-stabilized modulator keeps the long-term DC reference stable enough for drift compensation schemes. Pair the converter with a piezoelectric or MEMS accelerometer front end, route the differential pair as a matched pair away from motor and relay nodes, and use the three operating modes to trade sample rate against power when the node is battery or energy-harvesting powered. The main design consideration is aliasing: choose the operating mode so that the bandwidth of interest falls inside the decimation filter, then keep the anti-alias filter ahead of the modulator gentle to preserve the noise floor.

🖥️

Test and Measurement Instrumentation

Laboratory and field instruments need a converter that resolves small signals without long settling times, and the ADS1271IPW provides 24 bits with an SPI interface that transfers words efficiently to a host processor or FPGA. In a precision measurement front end, the wide-bandwidth noise performance of the family keeps the usable bandwidth high, so a single converter can serve both slow DC readings and faster transient capture. Mount it close to the analog input, provide local high-frequency decoupling and route the digital clock and data lines away from the analog input pair to avoid coupling noise into the modulator. Where a companion serial transceiver is needed to bring data out of the instrument, an SPI-capable level translator such as the MAX3221E family is a natural match.

💊

Medical and Health Monitoring Equipment

Patient monitoring and diagnostic equipment demand stable, low-drift conversion of small physiological signals, and the ADS1271IPW's 24-bit chopper-stabilized architecture with an extended temperature range fits that environment. Its SPI interface integrates easily with a monitoring microcontroller, and the 16-pin TSSOP footprint keeps the analog section compact next to sensor conditioning stages. Use the slowest operating mode available for ECG- or DC-level signals so that the decimation filter suppresses mains-coupled noise, and place the differential input pair symmetrically to reject common-mode pickup. Confirm the required medical qualification, isolation and creepage requirements for the finished device separately, since the converter itself carries no medical certification.

🧩

Data Acquisition and Environmental Logging

Environmental logging nodes that record temperature, humidity and pressure benefit from the ADS1271IPW because the wide industrial temperature range and 24-bit resolution preserve small analogue changes across seasons, while the low data rate of a slow operating mode reduces average power draw in remote installations. The single-channel differential input simplifies the board when each node handles one transducer, and the SPI link suits low-power microcontrollers with limited pin counts. Select the operating mode that matches the logging bandwidth, then average in firmware to suppress residual noise; do not push the rate higher than the logging needs, since the faster modes increase power consumption noticeably. Provide a low-noise reference and local decoupling at the device for the best long-term stability of logged values.

What is the ADS1271IPW used for?
The ADS1271IPW is a 24-bit, single-channel sigma-delta ADC used for precision industrial measurement where high resolution and low drift matter more than very high sampling rates. According to the Texas Instruments product page, the ADS1271 is a 24-Bit, 105kSPS, 1-Ch Delta-Sigma ADC for wide bandwidth applications, combining excellent DC accuracy with outstanding AC performance over an extended industrial temperature range.
What is the resolution and sampling rate of the ADS1271IPW?
The ADS1271IPW delivers 24-bit resolution at a maximum data rate of 105 kSPS. The manufacturer part page describes the device as a 24-bit, 105kSPS, 1-channel delta-sigma ADC, and the datasheet states that three operating modes allow optimization of speed, resolution, and power for a given measurement task.
What package and pin count does the ADS1271IPW use?
The ADS1271IPW is packaged in a 16-pin TSSOP (PW) surface-mount package. Distributor part data lists it as a 24-bit analog-to-digital converter with 1 input, sigma-delta architecture, in a 16-TSSOP package, and the operating temperature range spans -40 °C to +105 °C for industrial deployments.
How does the ADS1271 compare with the ADS1272?
The ADS1271 and ADS1272 come from the same Texas Instruments wide-bandwidth delta-sigma family and share the 24-bit, 105 kSPS class of performance in a 16-pin TSSOP footprint, so they are frequently substituted for one another. Their internal filter and operating-mode details differ, and the datasheet's mode table should be checked before treating the two as interchangeable in a fixed design.
What is the best drop-in replacement for ADS1271IPW?
The closest drop-in replacements are same-footprint 16-pin TSSOP Texas Instruments converters such as the ADS1272IPW and the ADS1262IPW, both of which can populate the same land pattern. The ADS1271IPWR is the tape-and-reel orderable of the same device for automated assembly. Request a Quote on this page for the exact configuration and packaging you need.
What interface does the ADS1271IPW use for data transfer?
The ADS1271IPW uses an SPI serial interface for data transfer and configuration. Distributor feature data for this part lists the serial port type as SPI, which keeps the converter practical for low-pin-count microcontroller and DSP platforms where a parallel data bus would be impractical.
What is the operating temperature range of the ADS1271IPW?
The ADS1271IPW is specified from -40 °C to +105 °C. The Texas Instruments datasheet describes the converter as supporting high-precision industrial measurement with DC and AC specifications assured over an extended industrial temperature range, which makes it suitable for factory automation and outdoor instrumented enclosures.
How much supply voltage does the ADS1271IPW need?
The ADS1271IPW operates from a nominal supply of approximately 4.75 V as shown in distributor part data. Use the manufacturer datasheet supply-voltage table to confirm the allowed operating range, decoupling requirements and the sequencing of analog versus digital rails when laying out the board.
Is ADS1271IPW suitable for load cell and strain gauge measurement?
Yes, the ADS1271IPW is a strong fit for load-cell and strain-gauge front ends because its 24-bit resolution, chopper-stabilized modulator and low drift suit the small millivolt-level signals produced by strain bridges. Place the differential input traces as a short, symmetric pair away from switching nodes and use the on-board decimation filter to reject out-of-band noise before the signal reaches the host processor.
What are the key specifications of ADS1271IPW that engineers should know?
The ADS1271IPW is a 24-bit, single-channel delta-sigma ADC with a 105 kSPS maximum data rate, a 16-pin TSSOP (PW) package, an SPI interface and a -40 °C to +105 °C industrial temperature range. It uses a high-order chopper-stabilized modulator with an on-board decimation filter and offers three operating modes for balancing speed, resolution and power.
Where can I download the ADS1271IPW datasheet PDF?
The manufacturer datasheet PDF is published by Texas Instruments at https://www.ti.com/lit/ds/symlink/ads1271.pdf, and the product landing page with parameter tables and ordering information is at https://www.ti.com/product/ADS1271. Use the datasheet for the pin-configuration table, electrical characteristics, and the operating-mode descriptions referenced throughout this page.
Where can I find the ADS1271IPW pinout and pin description?
The pin configuration for the ADS1271IPW is published in the pin configuration and description tables of the Texas Instruments ADS1271 datasheet, which is available at https://www.ti.com/lit/ds/symlink/ads1271.pdf. Assign PCB tracks from those tables so that supply pins, analog inputs, reference pins and serial interface pins are placed exactly as the datasheet indicates.
ADS1271IPW vs ADS1262IPW - which should I pick?
Choose the ADS1271IPW when you need the higher 105 kSPS data rate and 24-bit resolution with the wide-bandwidth noise performance of the ADS1271 family. Choose the ADS1262IPW when a lower data rate is acceptable and you prefer a lower-power, simpler conversion front end. Both occupy the same 16-pin TSSOP footprint, so the decision is usually specification-driven rather than layout-driven.
When should I choose the ADS1271IPW over a lower-resolution ADC?
Select the ADS1271IPW when your transducer output is small and noisy, for example a millivolt-level bridge or a high-impedance sensor, and when you need 24-bit resolution with low drift in an industrial temperature environment. Choose a lower-resolution ADC when the signal is large, wide-band and the system can tolerate quantization error and simpler filtering.
Where can I buy ADS1271IPW and what is the lead time?
Use the Request a Quote form on this page to check current availability, order quantities and lead time for the ADS1271IPW, and select the tape-and-reel or cut-tape packaging your assembly line needs. The manufacturer part page at https://www.ti.com/product/ADS1271 lists the available orderable variants and their status.
Is ADS1271IPW RoHS compliant and automotive qualified?
RoHS and AEC-Q100 status for the ADS1271IPW are listed as unknown on this page because the manufacturer declarations were not published alongside the part parameters reviewed. The device is an industrial-temperature converter rated from -40 °C to +105 °C, and for an automotive design please confirm the qualification status directly with the manufacturer before releasing the design.

נתוני עזר הנדסיים עבור ADS1271IPW — השוואה, הנחיות תכנון ומידע על תאימות.

מדריך בחירה

Choose the ADS1271IPW when your measurement is small-signal and wide enough to need the family's full bandwidth, and when 24-bit resolution with low drift across -40 °C to +105 °C is required. Its 105 kSPS ceiling and three operating modes make it the right part for load-cell bridges, condition monitoring and instrumentation that mixes DC accuracy with transient capture. Choose the ADS1262IPW when 65 kSPS is enough and you prefer lower power; the footprint and SPI interface are unchanged, so no layout work is needed. Choose the ADS1245IPWR or ADS1246IPWR for slow, near-DC logging where the extra bandwidth is wasted and simplicity matters more. The ADS1272IPW is the closest sibling for designs that want the same family feel with different filter behaviour. For automated assembly, use the ADS1271IPWR tape-and-reel orderable rather than the tube-packed ADS1271IPW. Request a Quote on this page for pricing and lead time on whichever configuration you select.

השוואה עם חלופות

פרמטר מוצר זה ADS1272IPW ADS1262IPW ADS1245IPWR ADS1246IPWR ADS1271IPWR
Package TSSOP-16 (PW) TSSOP-16 (PW) - same TSSOP-16 (PW) - same TSSOP-16 (PW) - same TSSOP-16 (PW) - same TSSOP-16 (PW) - same
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Resolution 24 bit 24 bit 24 bit 24 bit 24 bit 24 bit
Architecture Sigma-Delta, high-order chopper-stabilized modulator with on-board decimation filter Sigma-Delta, same family Sigma-Delta Sigma-Delta Sigma-Delta Sigma-Delta, same die
Interface SPI SPI SPI SPI SPI SPI

מבדילים עיקריים

  • Higher maximum conversion rate within the same TSSOP-16 footprint (לעומתADS1262IPW)
  • Wide-bandwidth noise performance from the ADS1271 family front end (לעומתADS1245IPWR)
  • Three configurable operating modes for speed, resolution and power balance (לעומתADS1271IPWR)
  • Same 16-pin TSSOP land pattern across the compared family (לעומתADS1272IPW)

הערות תכנון

Treat the differential analog input as a matched pair. Route the two input nets as closely coupled traces on the same layer, with a solid ground plane underneath, and keep them short so the input loop area stays small. Keep the pair away from switching nodes, relay contacts, inductors and the SPI clock/data traces, since the high-order modulator converts any coupled energy directly into in-band error. Provide local decoupling at the supply pins with a short ground return, and place the analog section on the quiet side of any partition on the board.

The decimation filter defines the usable analog bandwidth, so the digital filter and averaging in the host processor must match the data rate of the selected operating mode. If the firmware averages as if the rate were higher than the configured rate, aliasing and gain errors appear in the result. Choose the slowest mode that still covers the bandwidth of interest for near-DC measurements, because the higher-rate modes consume noticeably more power, and configure the SPI clock to the maximum rate the master supports without overshooting the converter's timing limits.

Estimated: at a nominal 4.75 V supply and a typical analog plus digital power draw in the tens of milliwatts, the junction temperature rise is small in the 16-pin TSSOP package, so no heatsink is normally required. Supply sequencing matters more than thermal design: bring the analog supply up before the digital interface signals are driven, and confirm the minimum operating supply in the datasheet electrical characteristics table before fixing the system rail. The reference source must be quiet, since reference noise maps directly onto the output codes.

Three pitfalls recur in designs using this converter. First, the front end is differential: driving only one input while leaving the other unconnected destroys accuracy, so tie the unused input to the correct common-mode point. Second, a long run of unshielded cable in front of the modulator picks up mains hum that the decimation filter cannot fully remove; place the converter close to the transducer or shield the cable. Third, assuming the full 105 kSPS in every mode causes average power to exceed the design budget, so verify the per-mode data rate and power figures in the operating-mode table.

מידע על תאימות

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
נטול עופרת
Unknown
נטול הלוגנים
Unknown
מינרלים של סכסוך
Unknown

RoHS, REACH, AEC-Q100, lead-free and halogen-free declarations were not published alongside the manufacturer parameters reviewed for the ADS1271IPW, so their status is recorded as unknown rather than assumed. The device is specified from -40 °C to +105 °C for industrial use.

הנתונים אומתו בתאריך: 2026-11-18 — נתונים אומתו ונערכו על ידי צוות הנדסת הרכיבים של XAIPART

חיפושים קשורים

ADS1271IPW datasheet ADS1271IPW datasheet pdf ADS1271IPW pinout ADS1271 24-bit delta-sigma ADC ADS1271 105kSPS ADC ADS1271IPW TSSOP-16 ADS1271IPW vs ADS1262IPW ADS1271IPW drop-in replacement ADS1271IPW equivalent ADC ADS1271IPW price and stock Texas Instruments ADS1271 ADS1271 load cell amplifier application ADS1271IPW operating modes ADS1271IPW SPI interface ADC ADS1271IPW replacement ADC TSSOP-16

רכיבים ומונחים קשורים

Texas Instruments ADS1271IPW ADS1271 ADS1271IPWR ADS1272IPW ADS1262IPW ADS1245IPWR ADS1246IPWR ADS1131IDR MAX3221EIPWR sigma-delta ADC delta-sigma modulator chopper-stabilized modulator decimation filter ADC data converter IC SPI TSSOP-16 TSSOP package family surface mount 105 kSPS 24-bit resolution industrial measurement load cell strain gauge
בקשת הצעת מחיר מהירה
מלא את כל הפרטים — צוות המכירות שלנו יגיב תוך 24 שעות
מספר חלק יצרן מארז QTY מחיר יעד סה"כ
✓
הצעת המחיר נשלחה!

נשיב לדוא"ל שלך בתוך 24 שעות

1
בקשת הצעת מחיר נשלחה
2
הצעת מחיר התקבלה
3
ההזמנה בוצעה
4
תשלום
5
נשלח
6
נמסר
צפה בפרטי בקשת הצעת המחיר