DG418LDJ+ - 35 Ohm SPST Analog Switch | Analog Devices
MPN: DG418LDJ+ ✓ פעילDG418LDJ+ סקירה
An analog switch is a semiconductor device that connects or isolates circuit nodes under digital control. The DG418LDJ+ belongs to the analog switch and multiplexer hierarchy, where it provides one independently controlled SPST path. Unlike a mechanical relay, the CMOS implementation switches without moving contacts, making it suitable for test systems, instrumentation, data acquisition, communications, and industrial control equipment where repetitive operation, compact size, and controlled switching behavior are important.
The device provides a 1:1, one-circuit configuration with a maximum on resistance of 35 ohm. Its normally open SPST topology keeps the switched path disconnected until the control input activates it. A 3 V logic-compatible control interface allows the switch to be operated by modern low-voltage digital logic, while the ±4.5 V to ±20 V analog supply range supports both dual-rail and bipolar signal environments. The listed maximum switching turn-off time is 185 ns.
Internally, the DG418LDJ+ uses CMOS circuitry to control the analog conduction path while separating the control input from the switched terminals. This architecture supports fast operation and low off-state leakage, although the exact leakage, bandwidth, charge injection, and channel capacitance values must be confirmed in the manufacturer datasheet before final signal-integrity calculations. The 8-pin PDIP package also provides generous lead spacing for breadboard, through-hole prototype, and manually assembled industrial applications.
Typical uses include precision test-and-measurement systems, sensor signal switching, sample-and-hold subsystems, battery-powered acquisition equipment, and communication interface routing. The normally open behavior is useful when a default isolation state is preferred, while the dual-supply range supports bipolar waveforms commonly encountered in instrumentation and industrial control systems.
PCB layout should keep the analog signal path short and place decoupling capacitors close to the supply pins. Confirm logic thresholds, signal swing, bandwidth, leakage, and switch capacitance against the application before release, especially when switching low-amplitude or high-impedance signals where charge injection and off-state leakage can affect measurement accuracy.
This page consolidates the component configuration, electrical limits, package details, comparison data, and practical replacement guidance for engineers evaluating the DG418LDJ+. It also distinguishes verified drop-in options from broader functional equivalents, helping simplify sourcing and board-level design decisions.
חלופות תחליף ישיר עבור DG418LDJ+ — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם DG418LDJ+ (אותו גורם צורה וטביעת רגל) — שונים ב Switch Configuration.
DG418LDJ
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
DG418DJ+
✅ Drop-Inצור קשר לקבלת מחיר
הצג גיליון נתונים ←DG418LDJ+ דירוגים מרביים ומאפיינים חשמליים
| Number of Circuits | 1 circuit |
| Multiplexer Configuration | 1:1 |
| Switch Configuration | SPST, normally open |
| Number of Channels | 1 channel |
| On Resistance | 35 ohm maximum |
| Logic Compatibility | +3 V compatible |
| Minimum Dual Supply Voltage | ±4.5 V |
| Maximum Dual Supply Voltage | ±20 V |
| Turn-Off Time | 185 ns maximum |
| Minimum Operating Temperature | -40 C |
| Maximum Operating Temperature | +85 C |
| Temperature Grade | Industrial |
| מארז | 8-pin PDIP |
| סגנון הרכבה | Through-hole |
| Number of Terminals | 8 terminals |
| Supply Configuration | Dual supply |
| סטטוס RoHS | unknown |
| REACH Status | unknown |
מדריך תצורת פינים של DG418LDJ+ 8-pin pdip
תצורת פינים עבור DG418LDJ+ (מארזת 8-pin pdip). מספרי פינים, פונקציות ותרשימי חיבורים מוגדרים ב-Datasheet של היצרן. יש לעיין בו לקבלת ה-footprint המדויק והנחיות הלחמה.
אין נתוני פריסת פינים מפורטים עבור DG418LDJ+.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
DG418LDJ+ מתאים עבור 6 יישוםs: Precision Test and Measurement Systems, Sensor Signal Routing, Data Acquisition Front Ends, Industrial Control Signal Isolation, Sample-and-Hold Signal Paths, Battery-Powered Portable Instruments.
Precision Test and Measurement Systems
The DG418LDJ+ fits precision test systems that require a normally open SPST path to isolate instrumentation, DUT terminals, or external fixtures. Its 35 ohm maximum on resistance gives the signal path a defined attenuation ceiling, while the 185 ns maximum turn-off time supports controlled switching between measurement conditions. The 3 V-compatible control interface also permits direct operation from common low-voltage test-controller logic. For high-accuracy measurements, include the switch resistance, leakage, charge injection, and thermal behavior in the measurement error budget. Confirm the final pin connections and signal limits using the manufacturer pin-description table.
מומלץ
Sensor Signal Routing
The DG418LDJ+ can route sensor signals in acquisition and conditioning systems where the source must remain disconnected until a measurement is requested. The normally open SPST configuration provides a useful default-isolated state, and the 35 ohm maximum on resistance is suitable for many medium-impedance sensor paths. The ±4.5 V to ±20 V dual-supply range accommodates bipolar sensor interfaces, while 3 V-compatible control reduces the need for additional control circuitry. For high-impedance sensors, verify off-state leakage and charge injection because those parameters can dominate the measurement error.
מומלץ
Data Acquisition Front Ends
The DG418LDJ+ is suitable for routing multiplexed analog channels in data-acquisition front ends that require one controlled SPST connection per switch position. Its 35 ohm maximum on resistance is acceptable when the downstream amplifier presents a substantially higher input impedance, and the 185 ns maximum turn-off time enables rapid transition between channels. A 3 V-compatible control input simplifies integration with modern acquisition controllers. Verify bandwidth, off leakage, and channel capacitance for the selected source impedance, because those characteristics determine whether switch loading must be included in the acquisition error budget.
מומלץ
Industrial Control Signal Isolation
The DG418LDJ+ can isolate a control, sensor, or field-test signal from an analog processing path in industrial equipment. Its normally open behavior provides a defined disconnection state during idle or fault conditions, while dual supplies from ±4.5 V to ±20 V support bipolar industrial signal ranges. The 3 V-compatible control interface allows direct use with modern controller logic. Because industrial systems may present large transients and long cable runs, validate the signal amplitude, supply sequencing, and protection requirements independently of the switch's basic on-resistance and timing ratings.
מומלץ
Sample-and-Hold Signal Paths
The DG418LDJ+ is appropriate for sample-and-hold or gated-measurement circuits where the analog path is enabled only during a defined sampling interval. The 185 ns maximum turn-off time and 35 ohm maximum on resistance provide useful initial design limits, while the normally open topology allows the source to remain disconnected outside that interval. The 3 V-compatible control input can be driven by a compact timing controller, and the dual ±4.5 V to ±20 V supplies accommodate bipolar node voltages. Check the actual hold capacitor, source impedance, charge injection, and switch leakage before using the component in a high-accuracy sampler.
מומלץ
Battery-Powered Portable Instruments
The DG418LDJ+ can serve as a controllable signal-isolation element in battery-powered portable measurement instruments. The 3 V-compatible control interface aligns with low-voltage digital control, and the ±4.5 V minimum dual supply provides a 9 V total operating range for bipolar signal conditioning. Because the switch can connect or isolate a high-impedance source, it can prevent unwanted loading when the instrument is between measurement phases. Designers should confirm supply current, leakage behavior, and control-logic levels in the manufacturer datasheet and should assess the analog path's sensitivity to switching transients.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור DG418LDJ+ — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | DG418LDJ | DG418DJ |
|---|---|---|---|
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Brand | Analog Devices | Analog Devices | Vishay Intertechnology |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit |
| Multiplexer Configuration | 1:1 | 1:1 | 1:1 |
| Switch Configuration | SPST, normally open | SPST, normally open | SPST, normally open |
| On Resistance | 35 ohm maximum | 35 ohm maximum | 35 ohm maximum |
| Mounting Style | Through-hole | Through-hole | Through-hole |
מבדילים עיקריים
- Directly identified 3 V-compatible control interface (לעומתDG418DJ)
- Documented dual-supply operating range (לעומתDG418DJ)
- Same-family ordering-code alternative (לעומתDG418LDJ)
- Defined maximum turn-off time (לעומתDG418DJ)
הערות תכנון
Use the 35 ohm maximum on resistance as the worst-case series element in the selected signal path. Check that the source impedance, downstream input impedance, leakage current, and allowed measurement error produce an acceptable attenuation budget. For high-impedance sources, off-state leakage and switch capacitance can be more important than on resistance, so use the complete manufacturer electrical-characteristics table when sizing the front end.
Keep the analog terminals and control input away from noisy clock, relay, and high-current switching paths. Route the switched signal as a short, continuous trace and place the device close to the protected source or measurement input. Maintain adequate spacing between adjacent analog nodes, and use a ground reference appropriate to the circuit's bipolar supply arrangement rather than assuming a single ground connection will handle all return currents.
Do not treat the 3 V-compatible control interface as permission to exceed the control-pin absolute maximum ratings or remove supply sequencing constraints. Confirm the control input thresholds, allowable input voltage, and off-state behavior in the manufacturer datasheet. Also verify that the switched signal remains within the device's analog input range and that both dual supplies remain within ±4.5 V to ±20 V during startup, shutdown, and fault conditions.
Place supply bypass capacitors close to the supply pins and maintain short return paths to the device ground reference. Although the listed operating range permits ±4.5 V to ±20 V, the usable design margin depends on supply tolerance, transient response, and the analog signal amplitude. Review the manufacturer application guidance for the appropriate capacitor values and decoupling topology, and verify logic compatibility when the control supply and analog supplies differ.
מידע על תאימות
The ordering suffix is associated with a lead-free product in catalog references, but no explicit RoHS, REACH, halogen-free, or conflict-minerals declaration was identified. Automotive qualification is not indicated for this industrial-temperature device.