INA240A2PW - 50V/V Bidirectional Current Sense Amp | Texas Instruments
MPN: INA240A2PW ✗ סוף ייצורINA240A2PW סקירה
A current-sense amplifier is an instrumentation amplifier that measures the small voltage developed across a current shunt and converts it into an amplified voltage proportional to current. This device belongs to the instrumentation-amplifier and current-sense-amplifier hierarchy, where its differential measurement, low offset voltage, and common-mode rejection improve the accuracy of power, motor, solenoid, and battery monitoring systems.
The A2 gain option provides 50 V/V amplification. The INA240 family operates from a 5.5 V supply and accepts common-mode voltages extending from -4 V to +80 V. Its enhanced PWM rejection is intended to suppress transient disturbance caused by switching power stages, while bidirectional operation allows measurement of positive or negative current without changing the signal path architecture.
The common-mode range and PWM rejection make the INA240A2PW especially useful where the shunt is placed near a motor, actuator, or inductive load. Although the analog output must remain within the amplifier's supply-voltage limits, the input common-mode voltage can move independently across the stated -4 V to +80 V range. This separation between input common-mode capability and output-supply limits is central to correct application design.
Typical uses include DC motor current control, solenoid and actuator monitoring, battery pack current measurement, industrial power conversion, and electronic loads. The precision architecture is also appropriate for systems that must recover a small shunt voltage accurately while rejecting rapidly changing voltages on the sensed power rail.
For layout, route the two shunt connections as a compact, symmetric pair and minimize the area enclosed by those traces. Place the shunt and amplifier input network close together, use a low-value differential filter only where its added noise and settling behavior are acceptable, and terminate the amplifier output according to the ADC or analog front-end requirements.
This page combines the manufacturer lifecycle information, verified distributor records, family-level alternatives, comparison criteria, and application-oriented design guidance for engineers evaluating the INA240A2PW as a current-sense amplifier for industrial and power-conversion systems.
חלופות תחליף ישיר עבור INA240A2PW — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
אין חלופות תואמות Drop-in עבור מוצר זה.
בקשת חלופותINA240A2PW דירוגים מרביים ומאפיינים חשמליים
| Product Type | Bidirectional precision current-sense amplifier |
| Gain | 50 V/V |
| Common-Mode Voltage Range | -4 V to +80 V |
| מתח אספקה | 5.5 V maximum |
| Maximum Input Offset Voltage | 25 µV |
| טווח טמפרטורת פעולה | -40 °C to +125 °C |
| מארז | 8-pin TSSOP (PW) |
| מספר פינים | 8 pins |
| סוג הרכבה | Surface mount |
| Current Direction | Bidirectional |
| Sensing Configuration | High-side or low-side |
| סוג פלט | Analog voltage |
| Circuit Count | 1 circuit |
| PWM Rejection | Enhanced |
| RoHS Compliance | ROHS3 compliant |
מדריך תצורת פינים של INA240A2PW 8-pin tssop (pw)
תצורת פינים עבור INA240A2PW (מארזת 8-pin tssop (pw)). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.
אין נתוני פריסת פינים מפורטים עבור INA240A2PW.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
INA240A2PW מתאים עבור 6 יישוםs: DC Motor Current Control, Solenoid and Actuator Feedback, Battery Pack Current Monitoring, Industrial Power Converter Control, Electronic Load and Bench Supply, Three-Phase Power Stage Monitoring.
DC Motor Current Control
The INA240A2PW fits brushed and brushless DC motor feedback because its 50 V/V gain amplifies a small shunt voltage while the -4 V to +80 V common-mode range accommodates a motor supply that changes rapidly. Place the shunt in the high-side power path and route the differential input pair directly to the amplifier. The main design benefit is improved signal use with a compact analog-output interface; the trade-off is that PWM edge energy at the shunt can couple into the measurement, so layout and the amplifier's enhanced PWM rejection must be evaluated together.
מומלץ
Solenoid and Actuator Feedback
For solenoid, relay, and actuator monitoring, the INA240A2PW can measure current on a supply rail up to +80 V common-mode without requiring the sensed voltage to remain near the amplifier supply. Its 50 V/V gain converts a millivolt-scale shunt differential into a voltage suitable for an ADC or control loop. Bidirectional sensing supports both energization and transient return current, while the low 25 µV maximum input offset helps preserve accuracy at low current. Keep the shunt connection short and avoid routing input traces parallel to motor-switching edges.
מומלץ
Battery Pack Current Monitoring
The INA240A2PW is appropriate for battery charge, discharge, and over-current monitoring where the common-mode voltage can substantially exceed the 5.5 V amplifier supply. A shunt placed in the high-side battery path produces a differential voltage proportional to current, and the 50 V/V gain provides useful ADC resolution without requiring a high-voltage signal-conditioning amplifier. Bidirectional operation simplifies charge and discharge measurement. Designers must scale the shunt for the maximum current and confirm that the amplifier output remains within its supply-defined range at both current polarities.
מומלץ
Industrial Power Converter Control
The INA240A2PW can monitor inductor or MOSFET current in industrial power-conversion circuits because it tolerates a -4 V to +80 V common-mode range and is designed for systems with fast common-mode transients. The 50 V/V gain reduces the required shunt resistance for a given output signal, while the analog output simplifies closed-loop current control. Input filtering may be added for EMI control, but component values should be selected to avoid excessive differential-input capacitance or an unacceptable response delay during current transitions.
מומלץ
Electronic Load and Bench Supply
For electronic loads, programmable supplies, and test systems, the INA240A2PW offers precise 50 V/V current amplification with bidirectional operation. It can sense current on either polarity and across a broad common-mode range, making the output easier to condition than a raw millivolt shunt signal. Use the offset limit, gain error, and output range when establishing measurement uncertainty. A Kelvin connection to the shunt minimizes trace resistance errors, particularly when the application requires accurate current measurements at low shunt voltage.
מומלץ
Three-Phase Power Stage Monitoring
The INA240A2PW can monitor a low-side shunt in a three-phase inverter because its -4 V common-mode capability accommodates a ground-referenced shunt position and its PWM rejection helps attenuate switching disturbance. The 50 V/V gain provides a direct analog measurement for protection or diagnostics. Place each shunt close to its amplifier to minimize inductive pickup, keep high-current switching loops away from the input pair, and verify that the output remains valid during the highest expected transient and fault current.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור INA240A2PW — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה |
|---|---|
| Brand | Texas Instruments |
| Package | 8-pin TSSOP (PW) |
| Product Type | Bidirectional current-sense amplifier |
| Gain | 50 V/V |
| Common-Mode Voltage Range | -4 V to +80 V |
| Maximum Supply Voltage | 5.5 V |
| Maximum Input Offset Voltage | 25 µV |
| Operating Temperature Range | -40 °C to +125 °C |
| PWM Rejection | Enhanced |
| Output Type | Analog voltage |
מבדילים עיקריים
- Wide sensed common-mode range (לעומתINA190A2)
- Enhanced PWM rejection for switched systems (לעומתINA190A2)
- Higher gain than INA240A1PW (לעומתINA240A1PW)
הערות תכנון
Route INA and INA− as a short, symmetric differential pair from the shunt to the amplifier. Keep the pair away from switch nodes, gate-drive traces, and high-current return paths. Use a Kelvin connection when shunt accuracy matters: connect each amplifier input directly to its corresponding shunt pad and avoid sharing copper with the power-current path. This minimizes parasitic voltage pickup and preserves the benefit of the device's enhanced PWM rejection.
Do not confuse common-mode range with supply range. The INA240A2PW accepts a -4 V to +80 V sensed common-mode voltage while being powered from a maximum of 5.5 V. Its output must remain within the supply-defined output range. Calculate the output at maximum positive and negative current, including offset and tolerance, before selecting the shunt resistance or adding another gain stage.
If input filtering is required, place the differential filter components close to the amplifier and select their values against the required transient response rather than applying a generic RC network. Capacitance across the differential inputs can alter settling behavior, while unequal filtering can impair common-mode rejection. Validate the completed layout with the switching waveform, including overshoot and ringing at the shunt.
מידע על תאימות
RoHS3 compliance is identified in the product information. REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer for the exact ordering option.