LM2903HYPT - Dual Open-Collector Comparator | STMicroelectronics
MPN: LM2903HYPT ✓ פעילLM2903HYPT סקירה
A voltage comparator is an analog integrated circuit that compares two input voltages and produces a logic-level indication of their relationship. The LM2903HYPT belongs to the comparator hierarchy within analog ICs and interface electronics. Its differential inputs suit threshold, window, overvoltage, and sensor-conditioning circuits, while the open-collector outputs allow wired AND operation, level translation, or pull-up-based interfacing.
Each channel offers a typical input offset voltage of 1 mV, input offset current of ±5 nA, and input bias current of 25 nA. The input common-mode range includes ground, making the device useful in single-supply systems in which signals approach the lower supply rail. Output saturation voltage is 250 mV typical with 4 mA output current, and the outputs are compatible with DTL, TTL, CMOS, ECL, and MOS logic families.
The two independent comparators operate over a −40 °C to +150 °C temperature range. The HYPT ordering code places the device in an 8-TSSOP package supplied in tape-and-reel format. Its automotive qualification and RoHS-compliant construction support demanding industrial, automotive, and sensing applications where low input bias, wide supply range, and open-collector interface flexibility are important.
Typical uses include battery-powered monitoring, industrial sensor interfaces, overvoltage protection, control-loop threshold detection, and open-drain alarm signaling. The 36 V maximum single-supply operation also permits direct monitoring of higher-voltage systems when the input and supply ratings are respected.
For reliable implementation, place input and output traces away from fast-switching nodes, provide a pull-up resistor on each open-collector output, and verify common-mode, differential-input, and output-current limits against the manufacturer datasheet. The low input bias current helps preserve sensor accuracy, while the open-collector output requires an external pull-up.
This page combines exact operating specifications, pin-level implementation guidance, application analysis, and package-compatible replacement information to support faster design-in and sourcing decisions.
חלופות תחליף ישיר עבור LM2903HYPT — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם LM2903HYPT (אותו גורם צורה וטביעת רגל) — שונים ב Automotive Qualification, Comparator Type, Input Offset Voltage, Logic Compatibility, Output Type.
LM2903YMPT
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
LM2904YHPT
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
LM2904YMPT
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
LM2903YDR
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
LM2903QDRQ1
✅ Drop-Inצור קשר לקבלת מחיר
הצג גיליון נתונים ←LM2903HYPT דירוגים מרביים ומאפיינים חשמליים
| Comparator Count | 2 comparators |
| Comparator Type | Dual differential voltage comparator |
| סוג פלט | Open-collector |
| Single-Supply Voltage Range | 2 V to 36 V |
| Dual-Supply Voltage Range | ±1 V to ±18 V |
| זרם אספקה | 0.4 mA per comparator |
| Low-Voltage Supply Consumption | 1 mW per comparator at 5 V |
| Input Bias Current | 25 nA typical |
| Input Offset Current | ±5 nA typical |
| Input Offset Voltage | 1 mV typical |
| Response Time | 1.3 µs typical |
| Output Saturation Voltage | 250 mV typical at 4 mA output current |
| Input Common-Mode Range | Includes ground |
| טווח טמפרטורת פעולה | -40 °C to +150 °C |
| מארז | 8-TSSOP |
| Logic Compatibility | DTL, TTL, CMOS, ECL, and MOS |
| Automotive Qualification | AEC-Q100 qualified |
| סטטוס RoHS | Compliant |
תצורת פינים של LM2903HYPT
| פין 1 | OUT1 — Comparator 1 open-collector output |
| פין 2 | IN1- — Comparator 1 inverting input |
| פין 3 | IN1+ — Comparator 1 non-inverting input |
| פין 4 | V- — Ground or negative supply connection |
| פין 5 | IN2+ — Comparator 2 non-inverting input |
| פין 6 | IN2- — Comparator 2 inverting input |
| פין 7 | OUT2 — Comparator 2 open-collector output |
| פין 8 | V+ — Positive supply connection |
יישומים טיפוסיים
LM2903HYPT מתאים עבור 6 יישוםs: Automotive Sensor Threshold Detection, Industrial Overvoltage Protection, Battery-Powered Monitoring, Open-Drain Alarm Signaling, Precision Signal Crossing Detection, Embedded Control Logic Interface.
Automotive Sensor Threshold Detection
The LM2903HYPT fits automotive sensor-monitoring circuits that compare a conditioned sensor signal against a reference threshold. Its 25 nA typical input bias current minimizes loading on high-impedance sensors, while the 1.3 µs typical response supports prompt decision-making. Each channel can compare one signal or form a window detector. The −40 °C to +150 °C operating range and AEC-Q100 qualification are valuable for vehicle environments. Use the open-collector output with an appropriate pull-up to drive a discrete logic input, warning lamp driver, or diagnostic input. Verify transient protection, common-mode limits, and grounding before connecting external sensor wiring.
מומלץ
Industrial Overvoltage Protection
The LM2903HYPT can supervise a divided industrial signal and assert a fault indication when the monitored voltage crosses a programmed limit. Its wide 2 V to 36 V single-supply range supports systems operating above conventional low-voltage logic rails, while the input common-mode range including ground simplifies low-side sensing arrangements. The 250 mV typical saturation voltage at 4 mA provides a useful open-collector fault node. Add a suitably rated pull-up and account for output-leakage effects at high temperature. The comparator should be placed close to the divider and protected from switching transients to avoid false threshold crossings.
מומלץ
Battery-Powered Monitoring
The LM2903HYPT is suitable for low-power battery monitoring because each comparator typically consumes only 0.4 mA. It can compare a cell-derived voltage against a precision reference to detect low-battery or overvoltage conditions, and its low 25 nA typical input bias current helps avoid disturbing resistive dividers or high-impedance sensing networks. The open-collector output can be pulled up to a logic rail while keeping the device compatible with low-power system signaling. Designers should evaluate quiescent consumption over the complete battery voltage range and include the pull-up current in the complete standby-power budget.
מומלץ
Open-Drain Alarm Signaling
The LM2903HYPT can implement an open-drain alarm bus when multiple monitoring functions must share a wired signal. Each comparator output can pull the shared line low, while the pull-up establishes the inactive high state. The 36 V single-supply maximum provides flexibility for industrial interfaces, and the 1.3 µs typical response is sufficient for many warning and interlock functions. Because the device does not actively drive the output high, calculate the maximum pull-up resistor from the required sink current and minimum bus rise time. Check leakage from all attached nodes and ensure that the bus voltage remains inside the output and absolute maximum ratings.
מומלץ
Precision Signal Crossing Detection
The LM2903HYPT is appropriate for detecting when an analog signal crosses a defined reference level. Its typical input offset voltage of 1 mA-equivalent comparator threshold accuracy class, ±5 nA input offset current, and 1.3 µs response provide useful performance for general industrial signal conditioning. Two channels can support both overvoltage and undervoltage detection around a reference window. The input common-mode range includes ground, which is advantageous for single-supply systems sensing signals near 0 V. For precision applications, evaluate offset and propagation-delay variation over temperature rather than relying only on typical values, and use hysteresis or filtering where chatter around the threshold would be unacceptable.
מומלץ
Embedded Control Logic Interface
The LM2903HYPT can bridge a slowly changing analog condition to an embedded controller input by comparing the condition with a reference and providing an open-collector status signal. The output is compatible with DTL, TTL, CMOS, ECL, and MOS logic families, allowing a pull-up to the controller's supply voltage when the electrical interface permits it. The dual-channel arrangement supports two independent conditions, such as a temperature limit and a power-good indication. Keep the comparator path short, use a pull-up value that balances speed and current, and account for the difference between the comparator supply and the logic pull-up supply when evaluating input levels.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור LM2903HYPT — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | LM2903YMPT | LM2904YHPT | LM2904YMPT | LM2903YDR | LM2903QDR |
|---|---|---|---|---|---|---|
| Package | TSSOP-8 (PW) | TSSOP-8 (PW) | TSSOP-8 (PW) | TSSOP-8 (PW) | TSSOP-8 (PW) | TSSOP-8 (PW) |
| Brand | STMicroelectronics | STMicroelectronics | STMicroelectronics | STMicroelectronics | Texas Instruments | Texas Instruments |
| Comparator Count | 2 comparators | 2 comparators | 2 comparators | 2 comparators | 2 comparators | 2 comparators |
| Output Type | Open-collector | Open-collector | Open-collector | Open-collector | Open-collector | Open-collector |
מבדילים עיקריים
- Wide single-supply operating range (לעומתLM2903YDR)
- Automotive-oriented ordering option (לעומתLM2903YMPT)
- Low input bias for high-impedance sensing (לעומתLM2904YHPT)
- Open-collector interface flexibility (לעומתLM2903QDR)
הערות תכנון
Do not treat an open-collector output as a push-pull logic output. Attach a pull-up resistor to each output, and calculate its maximum value from the required output rise time, total bus capacitance, output leakage, and the minimum 4 mA sink condition cited in the manufacturer datasheet. Confirm that every pulled-up node remains below the output-voltage and absolute-maximum limits when all attached inputs can be high-impedance.
Place the comparator inputs and their reference divider close to the device, and keep those traces away from switching-node copper and high-current return paths. The 25 nA typical input bias is low, but input offset current and leakage can still shift a high-impedance threshold over temperature. A solid ground connection at pin 4 and short supply routing reduce common-mode errors in the 1 mV typical offset class.
The manufacturer datasheet specifies a wide 2 V to 36 V single-supply operating range, but the output pull-up may use a different voltage. Verify the output-state voltage, input common-mode range, and differential-input limit independently of the supply rating. In battery systems, include the comparator's 0.4 mA typical current per channel and the pull-up current in the complete power budget.
Add appropriate hysteresis when the compared signal has noise or a slow crossing slope. Hysteresis prevents repeated output transitions near the threshold, while output filtering can reduce chatter when the input crosses slowly. Avoid excessive filtering where the intended response depends on the 1.3 µs typical propagation speed, and validate the complete threshold behavior over temperature.
מידע על תאימות
RoHS compliance and AEC-Q100 qualification are identified for LM2903HYPT. Other environmental and material-compliance fields are not established by the available technical records.