AD549JH - 0.15 pA Low-Bias Electrometer Op Amp | Analog Devices
MPN: AD549JH ✓ सक्रियAD549JH अवलोकन
An electrometer operational amplifier is a voltage amplifier optimized for signals connected to exceptionally high-impedance sources. The AD549 belongs to the precision operational-amplifier hierarchy and combines low input current, low offset voltage, and low offset drift in one package. This makes it suitable for current-to-voltage conversion, sensor-interface circuits, precision integrators, and low-droop sample-and-hold systems.
The AD549JH offers 0.15 pA typical input bias current and a 1 MHz gain-bandwidth product. Its 3 V/us slew rate supports moderate-amplitude signal changes, while the laser-trimmed 1 mV input offset voltage supports precision DC operation. The hermetic TO-99 package also provides a through-hole mechanical format suited to sensitive analog instrumentation and laboratory equipment.
The circuit architecture uses guarded Topgate JFET inputs to minimize leakage into the input nodes. Because the input current is exceptionally low, board contamination, protection-diode leakage, soldering residue, humidity, and PCB leakage can become significant error sources. Input and output networks should therefore be designed for clean guarding, stable reference paths, and minimal leakage rather than relying only on nominal amplifier specifications.
Typical uses include pH and ion-selective electrode interfaces, photodiode current measurement, electrochemical analysis, high-impedance probes, precision current-to-voltage conversion, and laboratory measurement systems. The same low-leakage characteristics also support precision integration and sample-and-hold circuitry when droop and input bias current must remain small.
When using the AD549JH, protect the input from excessive voltage while accounting for protection-device leakage, clean the PCB according to the handling requirements for electrometer circuits, and provide adequate input and output decoupling. Because the amplifier is intended for high-impedance nodes, even a small leakage current can create a meaningful measurement error at the source impedance.
This page combines the AD549JH device identity, package information, precision electrical characteristics, application guidance, and drop-in comparison data to support engineering selection and PCB-level design decisions.
के लिए ड्रॉप-इन विकल्प AD549JH — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस सीरीज़ के वेरिएंट
समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं AD549JH (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Package Type, Slew Rate, Number of Channels, Input Offset Voltage Drift Maximum, Offset Adjustment Method.
AD549JHZ
✅ ड्रॉप-इनकीमत के लिए संपर्क करें
डेटाशीट देखें →AD549LHZ
✅ ड्रॉप-इनकीमत के लिए संपर्क करें
डेटाशीट देखें →OPA128LM
✅ ड्रॉप-इन📋 संदर्भ विकल्प (कैटलॉग में नहीं)
OPA128KM
✅ ड्रॉप-इन📋 संदर्भ विकल्प (कैटलॉग में नहीं)
AD549JH Maximum Ratings और Electrical Characteristics
| Amplifier Type | Electrometer operational amplifier |
| Number of Channels | 1 channel |
| Input Bias Current | 0.15 pA |
| Input Offset Voltage | 1 mV |
| Gain-Bandwidth Product | 1 MHz |
| Slew Rate | 3 V/us |
| Input Technology | Topgate JFET |
| Offset Voltage Adjustment | Laser trimmed |
| Package Type | TO-99-8 hermetic |
| माउंटिंग प्रकार | Through-hole |
| पिन की संख्या | 8 pins |
AD549JH पिन कॉन्फ़िगरेशन
| पिन 1 | OFFSET NULL — Offset-voltage null adjustment input |
| पिन 2 | INVERTING INPUT — Inverting signal input |
| पिन 3 | NONINVERTING INPUT — Non-inverting signal input |
| पिन 4 | V- — Negative supply connection |
| पिन 5 | OFFSET NULL — Offset-voltage null adjustment input |
| पिन 6 | OUTPUT — Amplified output |
| पिन 7 | V+ — Positive supply connection |
| पिन 8 | NC — Not connected |
सामान्य अनुप्रयोग
AD549JH के लिए उपयुक्त है 6 अनुप्रयोगs: Photodiode Transimpedance Amplification, Electrochemical Sensor Interface, Precision Current-to-Voltage Conversion, pH and Ion-Selective Electrode Measurement, Precision Integrator and Low-Droop Sample-and-Hold, High-Impedance Laboratory Probe Amplifier.
Photodiode Transimpedance Amplification
The AD549JH fits low-level photodiode measurement because its 0.15 pA input bias current minimizes disturbance of the detector node. It can be configured as a transimpedance amplifier, converting photocurrent into a measurable voltage while the 3 V/us slew rate and 1 MHz gain-bandwidth product provide moderate signal bandwidth. The critical design consideration is PCB leakage: guard the photodiode input, minimize contamination, and choose protection components with low leakage. A large feedback resistor can create high closed-loop gain, but its thermal noise and input-node capacitance must be balanced against amplifier stability and achievable bandwidth.
अनुशंसित
Electrochemical Sensor Interface
The AD549JH is suitable for electrochemical and ion-sensor interfaces because the 0.15 pA bias current limits the error introduced through very high source impedances. Its 1 mV laser-trimmed input offset voltage supports low-level signal conditioning, while the hermetic TO-99 package provides a stable through-hole platform for laboratory and industrial analog modules. The input node should be physically guarded and kept free of flux residue. Bias-current error becomes more important as sensor impedance rises, so guarding and leakage control can determine whether the theoretical circuit performance is achieved.
अनुशंसित
Precision Current-to-Voltage Conversion
The AD549JH supports precision current-to-voltage conversion where a 0.15 pA input bias current is small enough to preserve the accuracy of microampere or picoampere-scale source currents. Its 1 mV trimmed offset and 3 V/us slew rate provide useful DC precision without turning the device into a high-speed amplifier. In a transimpedance stage, confirm the maximum feedback resistance, available phase margin, and the resulting noise gain across the intended frequency range. Place the feedback components close to the amplifier and guard the summing node to minimize parasitic leakage and capacitance.
अनुशंसित
pH and Ion-Selective Electrode Measurement
The AD549JH fits high-impedance pH and ion-selective electrode measurement because conventional amplifier input currents can create unacceptable errors across the electrode's very high source impedance. The AD549JH's 0.15 pA input bias current and laser-trimmed 1 mV offset voltage support precision DC amplification of the electrode signal. The implementation must use guarding, clean insulation, moisture-resistant contamination control, and low-leakage protection components. Its 1 MHz gain-bandwidth product is more than adequate for many chemical measurements, while the 3 V/us slew rate allows the output to respond to slow sensor changes without introducing timing delay.
अनुशंसित
Precision Integrator and Low-Droop Sample-and-Hold
The AD549JH can implement a precision integrator or low-droop sample-and-hold circuit because its 0.15 pA input bias current reduces charge injection into the holding capacitor. The 1 MHz gain-bandwidth product and 3 V/us slew rate provide a useful operating range for low-frequency signal acquisition. Practical performance still depends on capacitor leakage, dielectric absorption, switch charge injection, and board contamination. Use a low-leakage holding capacitor and clean switching nodes, and evaluate the circuit over its full temperature range because passive leakage can become dominant even when the amplifier contribution is very small.
अनुशंसित
High-Impedance Laboratory Probe Amplifier
The AD549JH is appropriate for amplifying outputs from high-impedance laboratory probes where probe leakage, cable insulation, and humidity can contribute more error than the amplifier itself. Its 0.15 pA input bias current and 1 mV laser-trimmed offset voltage provide a low-noise foundation for sensitive DC measurements, while the hermetic TO-99 package supports reliable through-hole construction. Use guarded input routing, moisture-resistant cleaning practices, and low-leakage terminal hardware. The 1 MHz bandwidth is intended for precision rather than high-speed waveform work, so additional bandwidth should be added only with careful stability analysis.
अनुशंसित
अनुशंसित उत्पादों का सारांश
के लिए इंजीनियरिंग संदर्भ डेटा AD549JH — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद | AD549JHZ | AD549LHZ | OPA128LM | OPA128KM |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments | Texas Instruments |
| Package | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
| Number of Pins | 8 pins | 8 pins | 8 pins | 8 pins | 8 pins |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel |
मुख्य विशेषताएँ
- Exceptionally low input bias current for an 8-pin TO-99 electrometer amplifier (बनामOPA128LM)
- Laser-trimmed precision offset (बनामOPA128KM)
- TO-99 hermetic through-hole platform (बनामAD549LHZ)
डिज़ाइन नोट्स
Treat the summing node as the most sensitive area of the board. Route it with short traces, surround it with a driven guard where appropriate, keep high-impedance signal lines away from supply and digital routes, and remove flux residue after assembly. The AD549JH's 0.15 pA bias current makes contamination-generated leakage potentially significant. Use conformal coating only after verifying that the coating and connectors do not introduce unacceptable dielectric or moisture-related behavior.
Do not select clamp diodes solely by their nominal voltage rating; their reverse leakage at the operating temperature can create errors comparable to the AD549JH input bias current. Where reverse bias is possible, evaluate leakage across temperature and select a protection strategy that preserves input-current performance. Also verify that external offset-adjustment networks do not degrade offset drift or noise unnecessarily when the laser-trimmed 1 mV offset is already sufficient.
Keep feedback components and their associated nodes close to the amplifier, and account for parasitic capacitance when using a large transimpedance resistor. The device's 1 MHz gain-bandwidth product and 3 V/us slew rate are sufficient for many low-frequency measurement systems, but transimpedance stability depends on the complete feedback network rather than amplifier specifications alone. Evaluate phase margin across the target frequency range and include the sensor capacitance in the stability analysis.
Use stable, low-noise supply connections and place the required bypass capacitors close to the positive and negative supply pins. Check the datasheet limits for input common-mode voltage, output swing, supply range, and output-current capability before finalizing the circuit. The output can saturate near the supply rails, so headroom should be included for the required signal range, load current, and temperature variation.
अनुपालन जानकारी
Compliance status was not stated in the manufacturer and distributor information identified for AD549JH. AEC-Q100 is not applicable because the AD549 is an analog operational amplifier rather than an automotive-qualified device.