AD549JH - 0.15 pA Low-Bias Electrometer Op Amp | Analog Devices
MPN: AD549JH ✓ 啟用中AD549JH 概覽
An electrometer operational amplifier is a voltage amplifier optimized for signals connected to exceptionally high-impedance sources. The AD549 belongs to the precision operational-amplifier hierarchy and combines low input current, low offset voltage, and low offset drift in one package. This makes it suitable for current-to-voltage conversion, sensor-interface circuits, precision integrators, and low-droop sample-and-hold systems.
The AD549JH offers 0.15 pA typical input bias current and a 1 MHz gain-bandwidth product. Its 3 V/us slew rate supports moderate-amplitude signal changes, while the laser-trimmed 1 mV input offset voltage supports precision DC operation. The hermetic TO-99 package also provides a through-hole mechanical format suited to sensitive analog instrumentation and laboratory equipment.
The circuit architecture uses guarded Topgate JFET inputs to minimize leakage into the input nodes. Because the input current is exceptionally low, board contamination, protection-diode leakage, soldering residue, humidity, and PCB leakage can become significant error sources. Input and output networks should therefore be designed for clean guarding, stable reference paths, and minimal leakage rather than relying only on nominal amplifier specifications.
Typical uses include pH and ion-selective electrode interfaces, photodiode current measurement, electrochemical analysis, high-impedance probes, precision current-to-voltage conversion, and laboratory measurement systems. The same low-leakage characteristics also support precision integration and sample-and-hold circuitry when droop and input bias current must remain small.
When using the AD549JH, protect the input from excessive voltage while accounting for protection-device leakage, clean the PCB according to the handling requirements for electrometer circuits, and provide adequate input and output decoupling. Because the amplifier is intended for high-impedance nodes, even a small leakage current can create a meaningful measurement error at the source impedance.
This page combines the AD549JH device identity, package information, precision electrical characteristics, application guidance, and drop-in comparison data to support engineering selection and PCB-level design decisions.
直接替換替代品,適用於 AD549JH — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD549JH (相同外形與佔位) — 差異在於 Package Type, Slew Rate, Number of Channels, Input Offset Voltage Drift Maximum, Offset Adjustment Method.
AD549JHZ
✅ 直接替換聯絡詢價
查看資料表 →AD549LHZ
✅ 直接替換聯絡詢價
查看資料表 →OPA128LM
✅ 直接替換📋 參考替代品(不在目錄中)
OPA128KM
✅ 直接替換📋 參考替代品(不在目錄中)
AD549JH 最大額定值與電氣特性
| Amplifier Type | Electrometer operational amplifier |
| Number of Channels | 1 channel |
| Input Bias Current | 0.15 pA |
| Input Offset Voltage | 1 mV |
| Gain-Bandwidth Product | 1 MHz |
| Slew Rate | 3 V/us |
| Input Technology | Topgate JFET |
| Offset Voltage Adjustment | Laser trimmed |
| Package Type | TO-99-8 hermetic |
| 安裝類型 | Through-hole |
| 腳位數 | 8 pins |
AD549JH 腳位配置
| 腳位 1 | OFFSET NULL — Offset-voltage null adjustment input |
| 腳位 2 | INVERTING INPUT — Inverting signal input |
| 腳位 3 | NONINVERTING INPUT — Non-inverting signal input |
| 腳位 4 | V- — Negative supply connection |
| 腳位 5 | OFFSET NULL — Offset-voltage null adjustment input |
| 腳位 6 | OUTPUT — Amplified output |
| 腳位 7 | V+ — Positive supply connection |
| 腳位 8 | NC — Not connected |
典型應用
AD549JH 適用於 6 應用s: Photodiode Transimpedance Amplification, Electrochemical Sensor Interface, Precision Current-to-Voltage Conversion, pH and Ion-Selective Electrode Measurement, Precision Integrator and Low-Droop Sample-and-Hold, High-Impedance Laboratory Probe Amplifier.
Photodiode Transimpedance Amplification
The AD549JH fits low-level photodiode measurement because its 0.15 pA input bias current minimizes disturbance of the detector node. It can be configured as a transimpedance amplifier, converting photocurrent into a measurable voltage while the 3 V/us slew rate and 1 MHz gain-bandwidth product provide moderate signal bandwidth. The critical design consideration is PCB leakage: guard the photodiode input, minimize contamination, and choose protection components with low leakage. A large feedback resistor can create high closed-loop gain, but its thermal noise and input-node capacitance must be balanced against amplifier stability and achievable bandwidth.
推薦
Electrochemical Sensor Interface
The AD549JH is suitable for electrochemical and ion-sensor interfaces because the 0.15 pA bias current limits the error introduced through very high source impedances. Its 1 mV laser-trimmed input offset voltage supports low-level signal conditioning, while the hermetic TO-99 package provides a stable through-hole platform for laboratory and industrial analog modules. The input node should be physically guarded and kept free of flux residue. Bias-current error becomes more important as sensor impedance rises, so guarding and leakage control can determine whether the theoretical circuit performance is achieved.
推薦
Precision Current-to-Voltage Conversion
The AD549JH supports precision current-to-voltage conversion where a 0.15 pA input bias current is small enough to preserve the accuracy of microampere or picoampere-scale source currents. Its 1 mV trimmed offset and 3 V/us slew rate provide useful DC precision without turning the device into a high-speed amplifier. In a transimpedance stage, confirm the maximum feedback resistance, available phase margin, and the resulting noise gain across the intended frequency range. Place the feedback components close to the amplifier and guard the summing node to minimize parasitic leakage and capacitance.
推薦
pH and Ion-Selective Electrode Measurement
The AD549JH fits high-impedance pH and ion-selective electrode measurement because conventional amplifier input currents can create unacceptable errors across the electrode's very high source impedance. The AD549JH's 0.15 pA input bias current and laser-trimmed 1 mV offset voltage support precision DC amplification of the electrode signal. The implementation must use guarding, clean insulation, moisture-resistant contamination control, and low-leakage protection components. Its 1 MHz gain-bandwidth product is more than adequate for many chemical measurements, while the 3 V/us slew rate allows the output to respond to slow sensor changes without introducing timing delay.
推薦
Precision Integrator and Low-Droop Sample-and-Hold
The AD549JH can implement a precision integrator or low-droop sample-and-hold circuit because its 0.15 pA input bias current reduces charge injection into the holding capacitor. The 1 MHz gain-bandwidth product and 3 V/us slew rate provide a useful operating range for low-frequency signal acquisition. Practical performance still depends on capacitor leakage, dielectric absorption, switch charge injection, and board contamination. Use a low-leakage holding capacitor and clean switching nodes, and evaluate the circuit over its full temperature range because passive leakage can become dominant even when the amplifier contribution is very small.
推薦
High-Impedance Laboratory Probe Amplifier
The AD549JH is appropriate for amplifying outputs from high-impedance laboratory probes where probe leakage, cable insulation, and humidity can contribute more error than the amplifier itself. Its 0.15 pA input bias current and 1 mV laser-trimmed offset voltage provide a low-noise foundation for sensitive DC measurements, while the hermetic TO-99 package supports reliable through-hole construction. Use guarded input routing, moisture-resistant cleaning practices, and low-leakage terminal hardware. The 1 MHz bandwidth is intended for precision rather than high-speed waveform work, so additional bandwidth should be added only with careful stability analysis.
推薦
推薦產品摘要
工程參考資料,適用於 AD549JH — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD549JHZ | AD549LHZ | OPA128LM | OPA128KM |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments | Texas Instruments |
| Package | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
| Number of Pins | 8 pins | 8 pins | 8 pins | 8 pins | 8 pins |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel |
主要差異化特點
- Exceptionally low input bias current for an 8-pin TO-99 electrometer amplifier (對比OPA128LM)
- Laser-trimmed precision offset (對比OPA128KM)
- TO-99 hermetic through-hole platform (對比AD549LHZ)
設計說明
Treat the summing node as the most sensitive area of the board. Route it with short traces, surround it with a driven guard where appropriate, keep high-impedance signal lines away from supply and digital routes, and remove flux residue after assembly. The AD549JH's 0.15 pA bias current makes contamination-generated leakage potentially significant. Use conformal coating only after verifying that the coating and connectors do not introduce unacceptable dielectric or moisture-related behavior.
Do not select clamp diodes solely by their nominal voltage rating; their reverse leakage at the operating temperature can create errors comparable to the AD549JH input bias current. Where reverse bias is possible, evaluate leakage across temperature and select a protection strategy that preserves input-current performance. Also verify that external offset-adjustment networks do not degrade offset drift or noise unnecessarily when the laser-trimmed 1 mV offset is already sufficient.
Keep feedback components and their associated nodes close to the amplifier, and account for parasitic capacitance when using a large transimpedance resistor. The device's 1 MHz gain-bandwidth product and 3 V/us slew rate are sufficient for many low-frequency measurement systems, but transimpedance stability depends on the complete feedback network rather than amplifier specifications alone. Evaluate phase margin across the target frequency range and include the sensor capacitance in the stability analysis.
Use stable, low-noise supply connections and place the required bypass capacitors close to the positive and negative supply pins. Check the datasheet limits for input common-mode voltage, output swing, supply range, and output-current capability before finalizing the circuit. The output can saturate near the supply rails, so headroom should be included for the required signal range, load current, and temperature variation.
合規資訊