Analog Devices

AD549JH - 0.15 pA Low-Bias Electrometer Op Amp | Analog Devices

MPN: AD549JH ✓ Aktif
1 mV Vdss 0.15 pA Id TO-99-8 hermetic Package
MOQ: 1 |

AD549JH Genel Bakış

The Analog Devices AD549JH is a single-channel electrometer operational amplifier with an ultra-low input bias current of 0.15 pA, a gain-bandwidth product of 1 MHz, and a slew rate of 3 V/us, packaged in an 8-pin TO-99 hermetic package. Its input offset voltage is laser trimmed to 1 mV, while Topgate JFET technology supports precision measurement of very weak currents and voltages.

An electrometer operational amplifier is a voltage amplifier optimized for signals connected to exceptionally high-impedance sources. The AD549 belongs to the precision operational-amplifier hierarchy and combines low input current, low offset voltage, and low offset drift in one package. This makes it suitable for current-to-voltage conversion, sensor-interface circuits, precision integrators, and low-droop sample-and-hold systems.

The AD549JH offers 0.15 pA typical input bias current and a 1 MHz gain-bandwidth product. Its 3 V/us slew rate supports moderate-amplitude signal changes, while the laser-trimmed 1 mV input offset voltage supports precision DC operation. The hermetic TO-99 package also provides a through-hole mechanical format suited to sensitive analog instrumentation and laboratory equipment.

The circuit architecture uses guarded Topgate JFET inputs to minimize leakage into the input nodes. Because the input current is exceptionally low, board contamination, protection-diode leakage, soldering residue, humidity, and PCB leakage can become significant error sources. Input and output networks should therefore be designed for clean guarding, stable reference paths, and minimal leakage rather than relying only on nominal amplifier specifications.

Typical uses include pH and ion-selective electrode interfaces, photodiode current measurement, electrochemical analysis, high-impedance probes, precision current-to-voltage conversion, and laboratory measurement systems. The same low-leakage characteristics also support precision integration and sample-and-hold circuitry when droop and input bias current must remain small.

When using the AD549JH, protect the input from excessive voltage while accounting for protection-device leakage, clean the PCB according to the handling requirements for electrometer circuits, and provide adequate input and output decoupling. Because the amplifier is intended for high-impedance nodes, even a small leakage current can create a meaningful measurement error at the source impedance.

This page combines the AD549JH device identity, package information, precision electrical characteristics, application guidance, and drop-in comparison data to support engineering selection and PCB-level design decisions.

Drop-in alternatifler için AD549JH — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.

Bu Serideki Variantlar

Yedek parça uyumlu olan aynı serideki modeller AD549JH (aynı form faktörü ve ayağa oturma) — farklı olan Package Type, Slew Rate, Number of Channels, Input Offset Voltage Drift Maximum, Offset Adjustment Method.

Analog Devices
Package Type: TO-99-8 hermetic package
Slew Rate: 3 V/μs
Input Offset Voltage Drift Maximum: 15 μV/°C
İle Karşılaştır AD549JH →
Analog Devices
Package Type: TO-99 hermetic, 8 pins
Slew Rate: 3 V/µs
Number of Channels: 1 amplifier
İle Karşılaştır AD549JH →

AD549JHZ

✅ Yerleştirme
Analog Devices
📦 TO-99-8
Electrometer operational amplifier · 1 channel · 250 fA for AD549J grade · 1.00 mV for AD549J grade · 15 μV/°C · 1 MHz · 3 V/μs · ±5 V to ±18 V

Fiyat için iletişime geçin

Veri Şablonunu Görüntüle →

AD549LHZ

✅ Yerleştirme
Analog Devices
📦 TO-99-8
Single-circuit electrometer operational amplifier · Topgate JFET · 1 MHz · 1 circuit · Electrometer operational amplifier

Fiyat için iletişime geçin

Veri Şablonunu Görüntüle →

OPA128LM

✅ Yerleştirme
📦 TO-99-8
Uses the same 8-pin TO-99 through-hole format, while input bias current and offset-voltage differences require validation; the identified structural ratings match by 80%.

📋 Katalogda Olmayan Referans Alternatifi

OPA128KM

✅ Yerleştirme
📦 TO-99-8
Shares the 8-pin TO-99 through-hole format, while its electrical limits and temperature grade must be reconciled with the AD549JH; the identified structural ratings match by 80%.

📋 Katalogda Olmayan Referans Alternatifi

AD549JH Maksimum Değerlendirmeler & Elektriksel Özellikler

Amplifier Type Electrometer operational amplifier
Number of Channels 1 channel
Input Bias Current 0.15 pA
Input Offset Voltage 1 mV
Gain-Bandwidth Product 1 MHz
Slew Rate 3 V/us
Input Technology Topgate JFET
Offset Voltage Adjustment Laser trimmed
Package Type TO-99-8 hermetic
Montaj Türü Through-hole
Pin Sayısı 8 pins

AD549JH Pin Yapısı

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 OFFSET NULL — Offset-voltage null adjustment input
Pin 2 INVERTING INPUT — Inverting signal input
Pin 3 NONINVERTING INPUT — Non-inverting signal input
Pin 4 V- — Negative supply connection
Pin 5 OFFSET NULL — Offset-voltage null adjustment input
Pin 6 OUTPUT — Amplified output
Pin 7 V+ — Positive supply connection
Pin 8 NC — Not connected

Tipik Uygulamalar

AD549JH için uygundur 6 uygulamas: Photodiode Transimpedance Amplification, Electrochemical Sensor Interface, Precision Current-to-Voltage Conversion, pH and Ion-Selective Electrode Measurement, Precision Integrator and Low-Droop Sample-and-Hold, High-Impedance Laboratory Probe Amplifier.

📷

Photodiode Transimpedance Amplification

The AD549JH fits low-level photodiode measurement because its 0.15 pA input bias current minimizes disturbance of the detector node. It can be configured as a transimpedance amplifier, converting photocurrent into a measurable voltage while the 3 V/us slew rate and 1 MHz gain-bandwidth product provide moderate signal bandwidth. The critical design consideration is PCB leakage: guard the photodiode input, minimize contamination, and choose protection components with low leakage. A large feedback resistor can create high closed-loop gain, but its thermal noise and input-node capacitance must be balanced against amplifier stability and achievable bandwidth.

🧪

Electrochemical Sensor Interface

The AD549JH is suitable for electrochemical and ion-sensor interfaces because the 0.15 pA bias current limits the error introduced through very high source impedances. Its 1 mV laser-trimmed input offset voltage supports low-level signal conditioning, while the hermetic TO-99 package provides a stable through-hole platform for laboratory and industrial analog modules. The input node should be physically guarded and kept free of flux residue. Bias-current error becomes more important as sensor impedance rises, so guarding and leakage control can determine whether the theoretical circuit performance is achieved.

⚡

Precision Current-to-Voltage Conversion

The AD549JH supports precision current-to-voltage conversion where a 0.15 pA input bias current is small enough to preserve the accuracy of microampere or picoampere-scale source currents. Its 1 mV trimmed offset and 3 V/us slew rate provide useful DC precision without turning the device into a high-speed amplifier. In a transimpedance stage, confirm the maximum feedback resistance, available phase margin, and the resulting noise gain across the intended frequency range. Place the feedback components close to the amplifier and guard the summing node to minimize parasitic leakage and capacitance.

🧫

pH and Ion-Selective Electrode Measurement

The AD549JH fits high-impedance pH and ion-selective electrode measurement because conventional amplifier input currents can create unacceptable errors across the electrode's very high source impedance. The AD549JH's 0.15 pA input bias current and laser-trimmed 1 mV offset voltage support precision DC amplification of the electrode signal. The implementation must use guarding, clean insulation, moisture-resistant contamination control, and low-leakage protection components. Its 1 MHz gain-bandwidth product is more than adequate for many chemical measurements, while the 3 V/us slew rate allows the output to respond to slow sensor changes without introducing timing delay.

🖥️

Precision Integrator and Low-Droop Sample-and-Hold

The AD549JH can implement a precision integrator or low-droop sample-and-hold circuit because its 0.15 pA input bias current reduces charge injection into the holding capacitor. The 1 MHz gain-bandwidth product and 3 V/us slew rate provide a useful operating range for low-frequency signal acquisition. Practical performance still depends on capacitor leakage, dielectric absorption, switch charge injection, and board contamination. Use a low-leakage holding capacitor and clean switching nodes, and evaluate the circuit over its full temperature range because passive leakage can become dominant even when the amplifier contribution is very small.

🔬

High-Impedance Laboratory Probe Amplifier

The AD549JH is appropriate for amplifying outputs from high-impedance laboratory probes where probe leakage, cable insulation, and humidity can contribute more error than the amplifier itself. Its 0.15 pA input bias current and 1 mV laser-trimmed offset voltage provide a low-noise foundation for sensitive DC measurements, while the hermetic TO-99 package supports reliable through-hole construction. Use guarded input routing, moisture-resistant cleaning practices, and low-leakage terminal hardware. The 1 MHz bandwidth is intended for precision rather than high-speed waveform work, so additional bandwidth should be added only with careful stability analysis.

What is the AD549JH used for?
The AD549JH is an electrometer operational amplifier used to amplify signals from very high-impedance sources without introducing substantial input-current error. Its 0.15 pA input bias current, 1 MHz gain-bandwidth product, and 3 V/us slew rate make it suitable for precision current-to-voltage conversion, electrochemical sensors, pH probes, photodiode measurements, precision integrators, and low-droop sample-and-hold circuits. The manufacturer describes it as a monolithic electrometer amplifier using Topgate JFET technology.
What is the input bias current of the AD549JH?
The AD549JH has a typical input bias current of 0.15 pA. According to the Analog Devices AD549 datasheet, this ultra-low current is achieved with Topgate JFET technology and is intended for high-impedance measurement circuits. The specification is particularly important when the source impedance is high enough that even picoamp-scale leakage creates a substantial voltage error. Substantial care is still required to keep PCB contamination and protection-device leakage below the measurement sensitivity.
Where can I download the AD549JH datasheet PDF?
The official AD549JH datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD549.pdf. The document contains the device description, electrical characteristics, package information, pin descriptions, and application guidance for the AD549 family. Use the manufacturer pin-description table when assigning PCB connections and check the ordering guide to confirm how the JH suffix corresponds to package and temperature options.
What is the AD549JH pinout?
The AD549JH uses an 8-pin TO-99 package with a standard precision-op-amplifier arrangement: pin 2 is the inverting input, pin 3 is the non-inverting input, pin 6 is the output, pin 7 is the positive supply, and pin 4 is the negative supply. Pins 1 and 5 are offset-null pins, while pin 8 is not connected. Confirm all connections against the Analog Devices AD549 datasheet before fabrication because offsets and package details are critical in electrometer layouts.
How does the AD549JH compare with an ordinary precision op amp?
The AD549JH differs from an ordinary precision op amp primarily in its input-current behavior. Its 0.15 pA bias current and Topgate JFET input are designed for high-impedance sources, whereas many conventional precision amplifiers specify bias currents in picoamperes to nanoamperes. The AD549JH also provides a 1 MHz gain-bandwidth product, 3 V/us slew rate, and laser-trimmed 1 mV input offset voltage, making it appropriate when current leakage matters more than high bandwidth.
Can the AD549JH replace an OPA128LM?
The AD549JH and OPA128LM are both 8-pin through-hole precision amplifiers with the same TO-99-class mechanical format, but final replacement requires checking pin assignments, supply limits, offset specifications, bias current, and stability. According to the manufacturer descriptions, the AD549JH is pin compatible with standard FET and electrometer op amps. The OPA128LM is an 8-pin through-hole alternative candidate, but its temperature grade and detailed electrical limits should be checked against the original design requirements.
When should I choose the AD549JH instead of the OPA128LM?
Choose the AD549JH when the application requires its 0.15 pA input bias current, 1 mV laser-trimmed offset specification, and 3 V/us slew rate while retaining an 8-pin TO-99 footprint. Choose the OPA128LM only after verifying that its input bias current, offset drift, supply range, noise characteristics, and operating-temperature grade satisfy the measurement requirements. The deciding factor is usually input leakage and precision rather than package compatibility alone.
What is the best drop-in replacement for the AD549JH?
No universally qualified replacement can be identified from the available cross-reference information. AD549JHZ and AD549LHZ are the closest same-brand ordering options identified, while OPA128LM and OPA128KM are cross-brand 8-pin through-hole candidates requiring direct comparison of pinout, offset voltage, bias current, supply range, noise, drift, and temperature grade. Treat the drop-in list as a design-review starting point and validate the selected device against every operating limit in the manufacturer datasheet.
Is the AD549JH suitable for photodiode and electrochemical measurements?
Yes, the AD549JH is well suited to photodiode and electrochemical measurements because its 0.15 pA input bias current minimizes current drawn through the sensing node. In a transimpedance amplifier, the AD549JH can convert photocurrent or sensor current into a voltage, while its 3 V/us slew rate and 1 MHz gain-bandwidth product permit moderate bandwidth. The detector node still requires guarded routing, clean surfaces, and protection devices with suitably low leakage.
Does the AD549JH need offset-voltage adjustment?
The AD549JH does not require external offset adjustment for normal operation because its input offset voltage is laser trimmed to 1 mV. Offset-null pins 1 and 5 are available for applications that need additional fine adjustment, but external adjustment can increase offset-voltage drift and introduce noise if component quality and layout are poor. For the highest precision, use the trimmed device directly and control drift through temperature management, clean input construction, and stable reference circuitry.
How should an electrometer PCB be laid out for the AD549JH?
The AD549JH PCB should minimize leakage at the input node by using guarded or driven-guard traces, clean PCB surfaces, conformal protection where appropriate, and low-leakage protection devices. Keep the inverting input, feedback components, and sensitive signal traces short and isolated from high-impedance leakage paths. According to the Analog Devices application guidance, PCB cleanliness and contamination control are essential because parasitic leakage can overwhelm the amplifier's exceptionally low 0.15 pA bias current.
What are the AD549JH power-supply requirements?
The AD549JH is intended for precision dual-supply operation, with the negative and positive supplies connected to pins 4 and 7, respectively. The exact allowable supply-voltage range and total supply limits must be taken from the Analog Devices AD549 datasheet rather than inferred from the package description. The verified product listing identifies an 8-pin TO-99 single amplifier, but it does not publish a complete supply-voltage specification on its own.
Can AD549JHZ replace AD549JH without changing the PCB?
AD549JHZ is an AD549-family ordering option with the same 8-pin TO-99 package and the same pin-compatibility platform as AD549JH. A PCB change is therefore generally unnecessary, but engineers should verify the exact ordering code, package marking, temperature grade, supply rating, and any lead-finish differences before approving the substitution. Use the manufacturer ordering guide and datasheet to confirm that JHZ and JH meet the same electrical and environmental requirements.
Where can I buy AD549JH and what is its lead time?
The AD549JH can be requested through the Request a Quote form on this page, where the current commercial terms, stock status, and lead time should be confirmed before placing an order. The listed operating characteristics include a 0.15 pA input bias current, 1 MHz gain-bandwidth product, and 3 V/us slew rate. Because long-lead-time electrometer devices may require traceability or factory allocation, submit the exact MPN AD549JH and the required package quantity with the request.
What is the AD549JH price?
The current AD549JH commercial price should be confirmed through the Request a Quote form on this page rather than from a static price table. The product is a precision 0.15 pA electrometer amplifier in an 8-pin TO-99 hermetic package, so quote terms can depend on quantity, availability, and sourcing conditions. Request pricing for the exact AD549JH ordering code to avoid confusion with AD549JHZ, AD549LHZ, or related family members.
What is the AD549JH and what are its key specifications?
The AD549JH is a monolithic, single-channel electrometer operational amplifier from Analog Devices with 0.15 pA input bias current, 1 mV laser-trimmed input offset voltage, a 1 MHz gain-bandwidth product, and a 3 V/us slew rate. It uses Topgate JFET technology and is offered in an 8-pin hermetic TO-99 through-hole package. These characteristics prioritize very low input leakage and precision DC measurement over high-speed operation.

Mühendislik referans verileri: AD549JH — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.

Seçim Kılavuzu

Choose the AD549JH when the circuit measures a very weak current or voltage from a high-impedance source and the 0.15 pA input bias current is central to achieving useful accuracy. Its 1 mV laser-trimmed offset, 1 MHz gain-bandwidth product, 3 V/us slew rate, and 8-pin TO-99 package suit precision electrochemical, photodiode, probe, integrator, and sample-and-hold circuits. AD549JHZ and AD549LHZ are natural same-family candidates when their ordering and temperature requirements match. OPA128LM and OPA128KM use the same mechanical package, but they should be selected only after direct comparison of bias current, offset drift, noise, supply range, common-mode limits, temperature grade, and stability. Package compatibility alone does not guarantee equivalent electrometer performance.

Alternatiflerle Karşılaştırma

Parametre Bu Ürün AD549JHZ AD549LHZ OPA128LM OPA128KM
Brand Analog Devices Analog Devices Analog Devices Texas Instruments Texas Instruments
Package TO-99-8 TO-99-8 TO-99-8 TO-99-8 TO-99-8
Mounting Type Through-hole Through-hole Through-hole Through-hole Through-hole
Number of Pins 8 pins 8 pins 8 pins 8 pins 8 pins
Number of Channels 1 channel 1 channel 1 channel 1 channel 1 channel

Ana Farklılayıcılar

  • Exceptionally low input bias current for an 8-pin TO-99 electrometer amplifier (karşılaştırma:OPA128LM)
  • Laser-trimmed precision offset (karşılaştırma:OPA128KM)
  • TO-99 hermetic through-hole platform (karşılaştırma:AD549LHZ)

Tasarım Notları

Treat the summing node as the most sensitive area of the board. Route it with short traces, surround it with a driven guard where appropriate, keep high-impedance signal lines away from supply and digital routes, and remove flux residue after assembly. The AD549JH's 0.15 pA bias current makes contamination-generated leakage potentially significant. Use conformal coating only after verifying that the coating and connectors do not introduce unacceptable dielectric or moisture-related behavior.

Do not select clamp diodes solely by their nominal voltage rating; their reverse leakage at the operating temperature can create errors comparable to the AD549JH input bias current. Where reverse bias is possible, evaluate leakage across temperature and select a protection strategy that preserves input-current performance. Also verify that external offset-adjustment networks do not degrade offset drift or noise unnecessarily when the laser-trimmed 1 mV offset is already sufficient.

Keep feedback components and their associated nodes close to the amplifier, and account for parasitic capacitance when using a large transimpedance resistor. The device's 1 MHz gain-bandwidth product and 3 V/us slew rate are sufficient for many low-frequency measurement systems, but transimpedance stability depends on the complete feedback network rather than amplifier specifications alone. Evaluate phase margin across the target frequency range and include the sensor capacitance in the stability analysis.

Use stable, low-noise supply connections and place the required bypass capacitors close to the positive and negative supply pins. Check the datasheet limits for input common-mode voltage, output swing, supply range, and output-current capability before finalizing the circuit. The output can saturate near the supply rails, so headroom should be included for the required signal range, load current, and temperature variation.

Uyumluluk Bilgisi

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Kadmiyumdan Arınmış
Unknown
Klorofillerden Arınmış
Unknown
Çatışma Minerali
Unknown

Compliance status was not stated in the manufacturer and distributor information identified for AD549JH. AEC-Q100 is not applicable because the AD549 is an analog operational amplifier rather than an automotive-qualified device.

Veri doğrulanma tarihi: 2026-11-22 — XAIPART bileşen mühendislik ekibi tarafından doğrulanmış ve derlenmiş veri

İlgili Aramalar

AD549JH datasheet AD549JH datasheet pdf AD549JH pinout AD549JH TO-99 amplifier AD549JH 0.15 pA input bias AD549JH application circuit AD549JH photodiode amplifier AD549JH electrochemical sensor AD549JH vs OPA128LM AD549JH drop-in replacement AD549JH equivalent Analog Devices AD549JH AD549JH price AD549JH stock What is AD549JH used for?

İlgili Bileşenler ve Terimler

Analog Devices AD549 AD549JH AD549JHZ AD549LHZ Texas Instruments OPA128LM OPA128KM electrometer operational amplifier precision operational amplifier voltage amplifier analog integrated circuit Topgate JFET input bias current input offset voltage gain-bandwidth product slew rate transimpedance amplifier electrochemical sensor photodiode pH electrode precision integrator sample-and-hold TO-99-8 TO-99 package family through-hole surface-mount technology
Hızlı Teklif RFQ
Detayları tam doldurun — satış ekibimiz 24 saat içinde yanıt verecek
Parça Numarası Üretici Paket QTY Hedef Fiyat Genişletilmiş
✓
Teklif gönderildi!

24 saat içinde e-postanıza yanıt vereceğiz

1
RFQ Gönderildi
2
Teklif Alındı
3
Sipariş Yerleştirildi
4
Ödeme
5
Gönderildi
6
Teslim Edildi
RFQ Detaylarını Görüntüle