Analog Devices

AD602ARZ - Dual Low-Noise Variable Gain Amplifier | Analog Devices

MPN: AD602ARZ ✓ सक्रिय
16-lead SOIC Package
न्यूनतम ऑर्डर मात्रा: 1 |

AD602ARZ अवलोकन

The Analog Devices AD602ARZ is a dual, low-noise, wideband variable gain amplifier optimized for ultrasound imaging and other precision signal-chain applications. It provides two independent amplifier channels, 16 dB of gain control per channel, and a 16-lead SOIC package. The AD602 family is intended for systems requiring precise gain adjustment, low noise, low distortion, and wide bandwidth.

A variable gain amplifier is an amplifier whose gain can be controlled electronically through an external control voltage or interface. Within the signal-chain hierarchy, the AD602ARZ belongs to the variable gain amplifier class, which combines low-noise amplification with programmable gain control. It is intended for applications in which received signals vary over a wide dynamic range and must be normalized before measurement, digitization, or further processing.

The AD602ARZ supports independent control of its two channels, allowing left- and right-side signal paths or separate measurement channels to be adjusted with matched circuitry. Its low-noise design helps preserve weak signals and improves the useful dynamic range of downstream receivers. Its wideband architecture also makes it suitable for systems that need amplification beyond audio frequencies while maintaining controlled distortion and gain behavior.

Analog Devices identifies the AD600 and AD602 families as dual-channel, low-noise, wideband variable gain amplifiers optimized for ultrasound imaging systems. The AD602 specifically provides an 11.25 dB to 31 dB gain range according to the manufacturer product description. Each channel uses a high-gain-bandwidth amplifier, and the gain is controlled through a high-impedance, differential gain-control input that supports practical system-level gain adjustment.

Typical applications include ultrasound receiver channels, medical imaging systems, instrumentation requiring variable amplification, and other wideband signal-processing equipment. Because the AD602ARZ contains two independent channels, it can also support dual-axis, stereo, differential, or sequential acquisition systems when the circuit architecture calls for matched amplifier pairs.

When implementing the device, place input and output decoupling components close to the associated pins, maintain the control-input impedance recommended by the manufacturer, and keep sensitive high-impedance gain-control traces short and well guarded. Designers should verify bandwidth, output swing, supply headroom, and noise performance against the signal levels expected at the input of each channel.

This product page combines the manufacturer application description, package and channel configuration, practical design guidance, replacement assessment, and structured comparisons. It is intended to help engineers identify whether the AD602ARZ fits a given signal chain while understanding the distinctions between exact ordering codes, temperature grades, and true electrical replacements.

के लिए ड्रॉप-इन विकल्प AD602ARZ — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

इस सीरीज़ के वेरिएंट

समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं AD602ARZ (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Package, Product Type, Gain Range, Operating Temperature, Signal Type.

Analog Devices
Product Type: Dual-channel variable gain amplifier
इसके साथ तुलना करें AD602ARZ →
Analog Devices
Package: 16-pin SOIC
Product Type: Dual-channel variable gain amplifier
Operating Temperature: -40°C to +85°C
इसके साथ तुलना करें AD602ARZ →
Analog Devices
Gain Range: -10 dB to +30 dB
Signal Type: Analog
इसके साथ तुलना करें AD602ARZ →
Analog Devices
Gain Range: −10 dB to +30 dB per channel
Operating Temperature: 0°C to +70°C
इसके साथ तुलना करें AD602ARZ →

AD602AR

✅ ड्रॉप-इन
Analog Devices
📦 16-lead SOIC
Dual-channel variable gain amplifier · 2 channels · 0 dB to 42.14 dB · 32 dB/V · 35 MHz · 1 per channel · Voltage-controlled, 0 dB to 42.14 dB · Voltage-controlled attenuator followed by fixed-gain amplifier

कीमत के लिए संपर्क करें

डेटाशीट देखें →

AD602ARZ-R7

✅ ड्रॉप-इन
📦 16-lead SOIC
Same AD602ARZ electrical ordering code with a different reel shipment format, providing 0% electrical difference and the same 16-lead SOIC footprint

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

AD602ARZ-RL

✅ ड्रॉप-इन
📦 16-lead SOIC
Same AD602ARZ electrical ordering code with a different large-reel shipment format, providing 0% electrical difference and the same 16-lead SOIC footprint

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

AD602JRZ

✅ ड्रॉप-इन
Analog Devices
📦 16-lead SOIC
Dual-channel variable gain amplifier · 2 channels · −10 dB to +30 dB per channel · 31.07 dB · 35 MHz nominal · Nominally independent of gain · Up to +5.25 V · Down to −5.25 V

कीमत के लिए संपर्क करें

डेटाशीट देखें →

AD602ARZ Maximum Ratings और Electrical Characteristics

Product Type Dual variable gain amplifier
Number of Amplifier Channels 2 channels
Independent Channel Control 2 independent channels
Gain Control Range 11.25 dB to 31 dB per channel
Noise Performance Low-noise architecture
Bandwidth Class Wideband
Signal Type Dual analog input and output signal channels
Primary Application Ultrasound imaging
पैकेज 16-lead SOIC
पिन काउंट 16 pins
माउंटिंग प्रकार Surface mount

AD602ARZ 16-lead soic पिन कॉन्फ़िगरेशन गाइड

AD602ARZ (16-lead soic पैकेज) के लिए पिन कॉन्फ़िगरेशन। इस एनालॉग कंपोनेंट में इनपुट, आउटपुट और पावर सप्लाई पिन हैं। ऑफ़सेट नल, कम्पनसेशन और एनेबल पिन कॉन्फ़िगरेशन के लिए निर्माता डेटाशीट देखें। सिग्नल कंडीशनिंग और एम्प्लीफ़ायर सर्किट के लिए आदर्श।

AD602ARZ के लिए 16-lead soic पैकेज पिनआउट आरेख

इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: AD602ARZ.

देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।

सामान्य अनुप्रयोग

AD602ARZ के लिए उपयुक्त है 6 अनुप्रयोगs: Ultrasound Receiver Front Ends, Medical Ultrasound Imaging Systems, Dual-Channel Instrumentation, Wideband Signal Conditioning, Test and Measurement Equipment, Low-Noise Analog Signal Chains.

💊

Ultrasound Receiver Front Ends

The AD602ARZ is well suited to ultrasound receiver front ends because each of its two independent channels provides programmable gain from 11.25 dB to 31 dB while maintaining low-noise, wideband amplification. Position one channel on each receive path when matched processing is required, then control the gain to compensate for changes in tissue attenuation and echo strength. The dual architecture can reduce channel-count overhead compared with using separate single-channel amplifiers, although the circuit must still preserve impedance matching, signal integrity, and per-channel calibration. Confirm supply, output swing, and bandwidth limits against the AD602 datasheet before setting the analog front end.

💊

Medical Ultrasound Imaging Systems

The AD602ARZ addresses the wide dynamic range encountered in medical ultrasound echo signals, where weak reflections require low-noise amplification and stronger returns need controlled attenuation or gain reduction. Its two channels support compact acquisition architectures without sacrificing independent gain adjustment, while the 16-lead SOIC package simplifies integration into multichannel boards. Proper design requires checking noise density, input impedance, allowable bandwidth, and output compliance for the selected probe and beamformer. The family is specifically optimized for ultrasound imaging, making its gain-control range and low-distortion architecture more relevant than the generic input range of a fixed-gain amplifier.

🏭

Dual-Channel Instrumentation

The AD602ARZ can serve as a dual variable gain element in instrumentation that monitors two related analog signals, such as sensor outputs, differential measurements, or diagnostic channels. Independent gain control allows each channel to be normalized into a common operating range before digitization, while the low-noise architecture helps retain weak sensor information. For precision systems, evaluate input-referred noise, offset behavior, gain accuracy, and usable bandwidth against the signal source. The two-channel package also reduces the number of separate amplifier positions, but channel matching and calibration should be verified in the finished circuit rather than assumed from identical device specifications.

🔧

Wideband Signal Conditioning

The AD602ARZ is appropriate for wideband signal-conditioning stages that require programmable gain rather than a fixed amplification factor. Its gain range of 11.25 dB to 31 dB can normalize changing input amplitudes before a downstream converter, comparator, or analysis block. The low-noise and wideband characteristics help preserve signal integrity, but the usable result depends on layout, impedance matching, and control stability. Keep the gain-control path isolated from sensitive input routing, observe all specified output-swing limits, and verify that the selected operating bandwidth leaves adequate margin for filtering and downstream acquisition requirements.

📺

Test and Measurement Equipment

The AD602ARZ can support programmable gain blocks in test and measurement equipment where different input ranges must be handled without changing hardware gain settings. Its two independent channels are useful for measuring a reference and DUT side by side, applying different gains for level normalization, or building a differential acquisition front end. For laboratory accuracy, evaluate noise, distortion, bandwidth, and output settling against the instrument specification. The gain-control input should be driven by a clean, stable source, and the PCB should minimize parasitic coupling between the high-impedance control node and sensitive amplifier inputs.

🌐

Low-Noise Analog Signal Chains

The AD602ARZ fits low-noise analog chains that need controllable amplification of small or variable-level signals. By adjusting gain in the analog domain, the system can keep later stages within their usable range while avoiding excessive amplification of noise in a fixed-gain architecture. The AD602 family's low-noise, low-distortion design is especially relevant when dynamic range is limited by the front end. Designers should characterize the complete chain, including source impedance, cable or PCB losses, filter components, and ADC input range. The amplifier's gain-control behavior must also remain stable over the required operating and temperature range.

अनुशंसित उत्पादों का सारांश

AD602AR Analog Devices उपयोग में: Ultrasound Receiver Front Ends, Medical Ultrasound Imaging Systems, Dual-Channel Instrumentation, Wideband Signal Conditioning, Test and Measurement Equipment, Low-Noise Analog Signal Chains AD602JRZ Analog Devices उपयोग में: Ultrasound Receiver Front Ends, Wideband Signal Conditioning AD602ARZ-RL Alternate shipment format of the target amplifier उपयोग में: Medical Ultrasound Imaging Systems, Test and Measurement Equipment AD602ARZ-R7 Alternate reel format of the target device उपयोग में: Dual-Channel Instrumentation, Low-Noise Analog Signal Chains
What is the AD602ARZ?
The AD602ARZ is a dual, low-noise, wideband variable gain amplifier from Analog Devices, with two independent amplifier channels in a 16-lead SOIC package. According to the Analog Devices AD602 datasheet, Rev. F, the family is optimized for ultrasound imaging but is also applicable to systems that require precise gain control, low noise, low distortion, and wide bandwidth. Each channel provides programmable gain over an 11.25 dB to 31 dB range.
What are the key specifications of AD602ARZ that engineers should know?
The AD602ARZ is a two-channel variable gain amplifier in a 16-lead SOIC package, with an 11.25 dB to 31 dB gain-control range per channel. Analog Devices describes it as a low-noise, wideband amplifier optimized for ultrasound imaging, while also supporting precise gain, low-noise, low-distortion, and wideband signal-chain requirements. Supply voltage, current, exact bandwidth, input noise density, and detailed operating limits must be confirmed in the manufacturer datasheet.
Where can I download the AD602ARZ datasheet PDF?
The official AD602ARZ datasheet is available through the Analog Devices AD602 product page at https://www.analog.com/en/products/ad602.html. The manufacturer page provides the AD602 data sheet, product selection information, documentation, and ordering details. Use the AD602 datasheet, Rev. F, together with the exact AD602ARZ ordering code to confirm electrical limits, pin functions, temperature range, and recommended application circuits.
Where can I find the AD602ARZ pinout?
The AD602ARZ pinout is defined by the 16-lead SOIC package in the Analog Devices AD602 datasheet, Rev. F. Because the two amplifier channels and their gain-control connections must be assigned correctly, use the package drawing and pin-description table in the manufacturer document when laying out the PCB. Do not infer pin functions from a generic SOIC-16 drawing, because unused or test-related positions must be handled exactly as specified by Analog Devices.
Is AD602ARZ suitable for ultrasound imaging?
Yes, the AD602ARZ is specifically optimized for ultrasound imaging systems. According to the Analog Devices AD602 datasheet, Rev. F, the AD600 and AD602 families are low-noise, wideband dual-channel variable gain amplifiers designed for ultrasound but also suitable for any application requiring precise gain, low noise, low distortion, and wide bandwidth. Its two independent channels can support matched receive paths in ultrasound front ends.
Where can I buy AD602ARZ online?
The AD602ARZ can be requested for quotation through the Request a Quote form on this XAIPART product page. The form is the appropriate route for current commercial availability, quantity requirements, delivery expectations, and lead-time confirmation. Because distribution channels and stock conditions can change rapidly, request a quote against the exact AD602ARZ ordering code rather than relying on an outdated catalog listing.
What is the price of AD602ARZ?
Current AD602ARZ pricing is handled through the Request a Quote form on this XAIPART product page. The quote request should include the required quantity, acceptable packaging, target date, and shipment location so that the commercial response reflects the exact ordering code. Static prices are intentionally not reproduced in the technical content because they can become outdated and may not reflect the selected order quantity.
What is the lead time for AD602ARZ?
The current AD602ARZ lead time should be confirmed through the Request a Quote form on this XAIPART product page. Lead time can depend on order quantity, authorized-channel inventory, production status, and packaging requirements. Include the required delivery schedule and annual usage in the request so that the commercial response can distinguish stock-supported orders from scheduled production allocations.
Is AD602ARZ in stock?
Current AD602ARZ stock status should be confirmed using the Request a Quote form on this XAIPART product page. Provide the required quantity and acceptable date so the response reflects current supply rather than a historical listing. For production planning, identify whether small prototype quantities or larger scheduled quantities are needed, since those two purchasing situations can have different supply paths.
What can replace AD602ARZ?
AD602AR is the closest verified same-family alternative because it is also listed as a dual variable gain amplifier in a 16-lead SOIC package. However, exact electrical equivalence, temperature grade, and ordering-code differences must be checked against the AD602 datasheet, Rev. F. AD602ARZ-R7 and AD602ARZ-RL identify different shipping formats of the target rather than independent electrical designs, so they should not be treated as technology upgrades.
Is AD602ARZ the same as AD602AR?
The AD602ARZ and AD602AR are closely related AD602-family members in 16-lead SOIC packages, but their ordering suffixes may distinguish qualification, temperature, or shipment details. According to the manufacturer product page, the AD602 family provides dual low-noise variable gain amplification with an 11.25 dB to 31 dB gain range. Review the exact suffix definitions and electrical tables in the AD602 datasheet, Rev. F, before treating one as a drop-in replacement for the other.
AD602ARZ vs AD602AR: which is better for an ultrasound receiver?
Choose AD602ARZ when its exact ordering-code qualifications and temperature range match the ultrasound receiver design; choose AD602AR only after confirming that every required electrical and environmental condition is equivalent. Both parts are identified as dual variable gain amplifiers in 16-lead SOIC packages, and both belong to the family optimized for ultrasound imaging. The decisive comparison is the suffix-specific temperature, qualification, and ordering information in the manufacturer datasheet.
When should I choose AD602ARZ over AD602AR?
Choose AD602ARZ when the system requires its exact commercial ordering code, qualification level, temperature range, or termination format. The AD602AR can be considered when its ordering-code characteristics meet the receiver specification and the board can accept it without PCB or sourcing changes. Because both devices use the 16-lead SOIC package, package geometry alone does not establish equivalence; the ordering suffix and electrical tables must be checked first.
Is AD602ARZ suitable for dual-channel medical imaging?
The AD602ARZ is well aligned with dual-channel medical imaging because it contains two low-noise, wideband variable gain amplifier channels and is optimized for ultrasound imaging. Analog Devices states that the AD600 and AD602 families are applicable to systems requiring precise gain, low noise, low distortion, and wide bandwidth. Independent per-channel gain control can simplify matching between acquisition paths, although the complete signal chain still requires medical-system-level validation.
What is the best cross-brand equivalent for AD602ARZ?
No cross-brand drop-in equivalent for the AD602ARZ is established by the available manufacturer and component information. A valid replacement must match the 16-lead SOIC footprint, pin functions, 11.25 dB to 31 dB gain range, low-noise performance, bandwidth, supply requirements, and temperature grade while preserving the original gain-control behavior. Without those verified parameters, a similarly described variable gain amplifier should not be treated as a drop-in substitute.
Can AD602ARZ be used in instrumentation and test equipment?
Yes, the AD602ARZ can be used in instrumentation and test equipment when the signal bandwidth, noise, gain-control method, and output swing fit the required measurement chain. Analog Devices describes the AD602 as applicable beyond ultrasound to any system requiring precise gain, low noise, low distortion, and wide bandwidth. Confirm the exact supply, input, output, and gain-control limits in the AD602 datasheet, Rev. F, before committing the circuit.

के लिए इंजीनियरिंग संदर्भ डेटा AD602ARZ — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose AD602ARZ when the design requires a dual low-noise variable gain amplifier in a 16-lead SOIC package, especially for ultrasound or other wideband signal chains requiring an 11.25 dB to 31 dB gain range. AD602AR is the closest functional alternative, but its ordering suffix must be checked for temperature and qualification requirements. Use AD602ARZ-R7 or AD602ARZ-RL when those shipment formats match manufacturing needs; they are not electrical upgrades. AD602JRZ is relevant when its distinct temperature grade is desirable and remains footprint-compatible. No cross-brand replacement should be selected without verified pin, bandwidth, noise, gain-control, supply, and environmental equivalence. For new analog boards, the target is preferable when its exact ordering code and qualification match the intended product.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद AD602AR AD602ARZ-R7 AD602ARZ-RL AD602JRZ
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Package 16-lead SOIC 16-lead SOIC 16-lead SOIC 16-lead SOIC 16-lead SOIC
Product Type Dual variable gain amplifier Dual variable gain amplifier Dual variable gain amplifier Dual variable gain amplifier Dual variable gain amplifier
Number of Channels 2 channels 2 channels 2 channels 2 channels 2 channels
Gain Range 11.25 dB to 31 dB 11.25 dB to 31 dB 11.25 dB to 31 dB 11.25 dB to 31 dB 11.25 dB to 31 dB
Gain Control Programmable per channel Programmable per channel Programmable per channel Programmable per channel Programmable per channel
Signal Class Low-noise, wideband, low-distortion Low-noise, wideband, low-distortion Low-noise, wideband, low-distortion Low-noise, wideband, low-distortion Low-noise, wideband, low-distortion
Primary Application Ultrasound imaging and precise gain control Ultrasound imaging and precise gain control Ultrasound imaging and precise gain control Ultrasound imaging and precise gain control Ultrasound imaging and precise gain control
Ordering-Code Characteristics AD602ARZ AD602AR; suffix-specific conditions differ AD602ARZ with -R7 shipment format AD602ARZ with -RL shipment format AD602JRZ; J temperature grade differs

मुख्य विशेषताएँ

  • Independent dual-channel gain control (बनामAD602AR)
  • Exact target electrical identity with production shipment flexibility (बनामAD602ARZ-R7)
  • Same footprint and gain architecture (बनामAD602ARZ-RL)
  • Temperature-grade selection within the AD602 family (बनामAD602JRZ)

डिज़ाइन नोट्स

Route the two amplifier channels and their gain-control inputs symmetrically to reduce channel-to-channel timing and coupling differences. Keep the high-impedance gain-control paths away from input, output, and clock-like fast edges, and guard the sensitive nodes where layout rules permit. Place input and output decoupling capacitors close to the relevant device pins, and provide a direct, low-impedance return path beneath the SOIC footprint. The manufacturer AD602 datasheet should be used to assign every pin and identify any unused or test positions before fabrication.

Treat each channel as a wideband analog path rather than a low-frequency audio stage. Use short traces, controlled reference planes, and terminations appropriate to the source and load impedances; long branches or uncontrolled stubs can create reflections and reduce usable bandwidth. Check the complete signal chain against the AD602 bandwidth and output-swing limits under the intended gain setting. If the source impedance is high, account for bias-current and thermal-noise effects rather than relying on the amplifier's low-noise rating in isolation.

Do not assume that every AD602 ordering suffix is an independent functional upgrade. AD602ARZ-R7 and AD602ARZ-RL retain the target's electrical identity while changing shipment format, whereas AD602JRZ uses a different temperature-grade ordering suffix. Confirm the exact suffix meaning, temperature range, qualification status, and reel quantity in the manufacturer ordering guide. A package match alone is insufficient for production equivalence, particularly where system calibration, environmental qualification, or traceability requirements differ.

Plan the supply network for simultaneous operation of both channels because each channel can carry independent analog signals. Use the voltage and current limits stated in the AD602 datasheet, Rev. F, and include adequate bypass capacitance at the device pins. Estimated: if the final schematic specifies 5.0 V and 100 mA total, the ideal input-power draw is 0.50 W before regulator loss; actual consumption must be checked against the datasheet rather than this illustrative calculation.

अनुपालन जानकारी

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

The manufacturer product page does not provide extractable RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations for this ordering code. AEC-Q100 is not applicable because the AD602 is an analog signal-processing amplifier rather than an automotive-qualified device.

डेटा सत्यापन तिथि: 2026-11-17 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

AD602ARZ datasheet AD602ARZ pinout AD602ARZ datasheet pdf AD602ARZ specifications AD602ARZ equivalent AD602ARZ replacement AD602ARZ vs AD602AR AD602ARZ price AD602ARZ stock Analog Devices AD602ARZ AD602ARZ ultrasound amplifier AD602ARZ 16-SOIC footprint

संबंधित कंपोनेंट्स और शब्द

Analog Devices AD602ARZ AD602AR AD602ARZ-R7 AD602ARZ-RL AD602JRZ variable gain amplifier VGA low-noise amplifier wideband amplifier programmable gain amplifier analog signal chain dual-channel amplifier ultrasound imaging medical imaging gain control gain range input noise signal integrity SOIC-16 surface mount SMD semiconductor Analog Devices AD602 datasheet Rev. F
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें