INA110KPG4 - Fast-Settling FET Instrumentation Amplifier | Texas Instruments
MPN: INA110KPG4 ✗ जीवन की समाप्तिINA110KPG4 अवलोकन
An instrumentation amplifier is a specialized amplifier optimized for measuring the difference between two low-level input signals. Its internal architecture provides high input impedance, low output impedance, excellent common-mode rejection, and stable gain set by a resistor or selectable internal gain network. This makes the INA110KPG4 useful when sensor outputs are small, source impedance is high, or the measurement must reject common-mode interference appearing equally on both inputs.
The INA110KPG4 combines a 2.5 MHz bandwidth with fast settling, making it suitable for measurement channels that need to respond quickly after a control, excitation, or sensor input changes. Its FET-input stage supports low input bias current, while the 500 µV input offset specification defines the dc error budget for high-gain measurements. The 16-pin PDIP format is appropriate for through-hole prototype boards, laboratory instrumentation, educational systems, and established production assemblies that accept a dual-inline footprint.
The amplifier can operate with positive and negative supply rails, allowing the output to remain centered around ground while processing bipolar sensor signals. A reference connection permits output-voltage shifting when the system requires a nonzero midpoint. The available gains of 1, 10, 100, and 1000 allow the same device architecture to cover both high-level measurements and small differential signals without changing packages.
Typical uses include bridge-transducer amplification, low-current measurement, biomedical instrumentation, industrial sensor interfaces, laboratory measurement systems, and data-acquisition modules. The device is especially useful when the source impedance is too high for a conventional voltage-amplifier input or when the measured differential signal is much smaller than the surrounding common-mode voltage.
When laying out a board, keep the input and output paths short, provide a stable low-noise reference network, and observe the supply-voltage limits of ±6 V to ±18 V. Breadboard connections and long unprotected input tracks should be avoided because leakage, contamination, and parasitic capacitance can degrade accuracy and settling performance.
This product page combines package details, operating limits, application guidance, and verified drop-in alternatives. It also provides practical design notes for a legacy bipolar-supply instrumentation amplifier used in sensitive analog measurement systems.
के लिए ड्रॉप-इन विकल्प INA110KPG4 — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस सीरीज़ के वेरिएंट
समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं INA110KPG4 (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Package, Supply Voltage Range.
INA110KP
✅ ड्रॉप-इनकीमत के लिए संपर्क करें
डेटाशीट देखें →INA110KPG4 Maximum Ratings और Electrical Characteristics
| Product Type | Fast-settling FET-input instrumentation amplifier |
| Internal Amplifier Count | 3 amplifiers |
| Supply Voltage Range | ±6 V to ±18 V |
| Input Offset Voltage | 500 µV |
| Bandwidth | 2.5 MHz |
| आउटपुट प्रकार | Single-ended |
| Input Stage | FET-input |
| Available Gains | 1, 10, 100, and 1000 |
| पैकेज | 16-pin PDIP |
| Package Pin Count | 16 pins |
| Package Row Spacing | 7.62 mm |
| Package Pitch | 0.300 in |
| माउंटिंग स्टाइल | Through-hole |
| लाइफसाइकिल स्थिति | Inactive |
INA110KPG4 0.300 in पिन कॉन्फ़िगरेशन गाइड
INA110KPG4 (0.300 in पैकेज) के लिए पिन कॉन्फ़िगरेशन। इस एनालॉग कंपोनेंट में इनपुट, आउटपुट और पावर सप्लाई पिन हैं। ऑफ़सेट नल, कम्पनसेशन और एनेबल पिन कॉन्फ़िगरेशन के लिए निर्माता डेटाशीट देखें। सिग्नल कंडीशनिंग और एम्प्लीफ़ायर सर्किट के लिए आदर्श।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: INA110KPG4.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
INA110KPG4 के लिए उपयुक्त है 6 अनुप्रयोगs: Bridge Transducer Signal Conditioning, Low-Current Sensor Measurement, Biomedical Signal Acquisition, Industrial Pressure and Strain Monitoring, Laboratory Instrumentation, Data Acquisition Front End.
Bridge Transducer Signal Conditioning
The INA110KPG4 fits bridge-transducer front ends that produce a small differential voltage in the presence of a larger common-mode voltage. Its FET-input instrumentation-amplifier architecture avoids loading the sensor source, while selectable gains of 1, 10, 100, and 1000 allow the bridge output to be scaled before digitization. The 2.5 MHz bandwidth supports rapid response, and the single-ended output is convenient for a following data converter or measurement instrument. The 16-pin PDIP package also makes the amplifier practical for laboratory bridge boards and established through-hole assemblies.
Low-Current Sensor Measurement
The INA110KPG4 is appropriate for low-current sensors whose output impedance is too high for a conventional input stage. Its FET-input design supports low-bias-current measurement, while the instrumentation-amplifier configuration converts a weak differential sensor voltage into a single-ended signal referenced to ground or another selected reference. Gains of 10, 100, or 1000 can increase small-sensor output to a more useful measurement level. The 500 µV input offset specification must be considered alongside the selected gain when establishing the total measurement error.
Biomedical Signal Acquisition
The INA110KPG4 can condition differential biomedical or physiological sensor signals in a laboratory acquisition system. High input impedance reduces the burden placed on the sensor, and the selectable internal gains accommodate signal ranges from volts to millivolts. Its 2.5 MHz bandwidth is suitable for many general-purpose physiological measurement channels, while the single-ended output simplifies connection to an ADC input. Because medical applications can involve patient protection, the completed circuit must also satisfy the applicable safety, isolation, leakage, and electrode requirements of the finished system.
Industrial Pressure and Strain Monitoring
The INA110KPG4 suits pressure, load-cell, and strain-gauge monitoring circuits that operate in electrically noisy industrial environments. Its high-input-impedance differential stage reduces source loading, and the available gains of 1, 10, 100, and 1000 let designers select the signal scaling appropriate for the sensor range. The fast-settling, 2.5 MHz architecture provides useful response for changing mechanical loads, while the 500 µV offset specification helps define precision at higher gain. Board layout should keep input traces short and minimize leakage around the sensitive pins.
Laboratory Instrumentation
The INA110KPG4 is well suited to bench instrumentation that measures small differential voltages with a grounded single-ended output. Its 16-pin PDIP package is convenient for prototype and educational platforms, and its three internal amplifiers provide selectable gain without requiring a complete external instrumentation-amplifier network. The 2.5 MHz bandwidth permits reasonably fast measurements, while ±6 V to ±18 V supplies permit bipolar operation around ground. The reference connection gives the instrument designer an additional way to offset the output when matching an analog-to-converter input range.
Data Acquisition Front End
The INA110KPG4 can form the analog front end of a multichannel data-acquisition system for differential sensor signals. Selectable gains of 1, 10, 100, and 1000 normalize different input ranges before conversion, while the single-ended output can feed an ADC or sample-and-hold stage. Its 2.5 MHz bandwidth is adequate for many general-purpose acquisition channels and helps the amplifier settle following each conversion cycle. Designers should account for the 500 µV input offset, especially at gain 1000, and use clean grounding and supply arrangements to preserve measurement quality.
के लिए इंजीनियरिंग संदर्भ डेटा INA110KPG4 — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद | INA110KP |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 16-pin PDIP | 16-pin PDIP |
| Product Type | Fast-settling FET-input instrumentation amplifier | FET-input instrumentation amplifier |
| Package Pitch | 0.300 in (7.62 mm) | 16-pin PDIP |
मुख्य विशेषताएँ
- Fast 2.5 MHz instrumentation-amplifier bandwidth (बनामINA110KP)
- Selectable gain range in a 16-pin PDIP footprint (बनामINA110KP)
- Single-ended output with bipolar supplies (बनामINA110KP)
डिज़ाइन नोट्स
Keep the INA110KPG4 input traces short, symmetric, and away from switching nodes and high-current return paths. High input impedance does not eliminate sensitivity to leakage from board contamination, flux residue, or long unprotected traces. Maintain a consistent ground reference between the two inputs and place any gain-setting or reference components close to the associated device pins.
Evaluate settling with the intended gain, source impedance, reference connection, and downstream load rather than relying only on the 2.5 MHz bandwidth figure. Long wiring, breadboard contacts, and connector capacitance can materially change effective response. Use short analog traces, a stable reference network, and an acquisition sequence that allows the output to settle before sampling.
Do not apply a single-ended signal directly between the differential inputs without accounting for the common-mode voltage and source impedance. Both input nodes and the reference network must remain inside the device's permitted operating conditions. Also verify the gain connection on the manufacturer pin diagram because the internal gain network uses package pins rather than a separate external feedback resistor.
Provide clean positive and negative supply rails within the specified ±6 V to ±18 V range. Decouple each supply rail close to the device, and connect the bypass return directly to the device ground reference. Poor supply grounding can degrade output behavior and inject noise into a low-level differential measurement even when the amplifier itself is correctly connected.
अनुपालन जानकारी
The component is an instrumentation amplifier rather than an automotive-qualified device. Specific environmental, material, and conflict-minerals declarations were not identified in the product information and remain unknown.