INA110KPG4 - Fast-Settling FET Instrumentation Amplifier | Texas Instruments
部品番号: INA110KPG4 ✗ 生産終了INA110KPG4 概要
An instrumentation amplifier is a specialized amplifier optimized for measuring the difference between two low-level input signals. Its internal architecture provides high input impedance, low output impedance, excellent common-mode rejection, and stable gain set by a resistor or selectable internal gain network. This makes the INA110KPG4 useful when sensor outputs are small, source impedance is high, or the measurement must reject common-mode interference appearing equally on both inputs.
The INA110KPG4 combines a 2.5 MHz bandwidth with fast settling, making it suitable for measurement channels that need to respond quickly after a control, excitation, or sensor input changes. Its FET-input stage supports low input bias current, while the 500 µV input offset specification defines the dc error budget for high-gain measurements. The 16-pin PDIP format is appropriate for through-hole prototype boards, laboratory instrumentation, educational systems, and established production assemblies that accept a dual-inline footprint.
The amplifier can operate with positive and negative supply rails, allowing the output to remain centered around ground while processing bipolar sensor signals. A reference connection permits output-voltage shifting when the system requires a nonzero midpoint. The available gains of 1, 10, 100, and 1000 allow the same device architecture to cover both high-level measurements and small differential signals without changing packages.
Typical uses include bridge-transducer amplification, low-current measurement, biomedical instrumentation, industrial sensor interfaces, laboratory measurement systems, and data-acquisition modules. The device is especially useful when the source impedance is too high for a conventional voltage-amplifier input or when the measured differential signal is much smaller than the surrounding common-mode voltage.
When laying out a board, keep the input and output paths short, provide a stable low-noise reference network, and observe the supply-voltage limits of ±6 V to ±18 V. Breadboard connections and long unprotected input tracks should be avoided because leakage, contamination, and parasitic capacitance can degrade accuracy and settling performance.
This product page combines package details, operating limits, application guidance, and verified drop-in alternatives. It also provides practical design notes for a legacy bipolar-supply instrumentation amplifier used in sensitive analog measurement systems.
ドロップイン代替品: INA110KPG4 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA110KPG4 (同一形状・フットプリント) — 相違点: Package, Supply Voltage Range.
INA110KP
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA110KPG4 最大定格&電気的特性
| Product Type | Fast-settling FET-input instrumentation amplifier |
| Internal Amplifier Count | 3 amplifiers |
| Supply Voltage Range | ±6 V to ±18 V |
| Input Offset Voltage | 500 µV |
| Bandwidth | 2.5 MHz |
| 出力タイプ | Single-ended |
| Input Stage | FET-input |
| Available Gains | 1, 10, 100, and 1000 |
| パッケージ | 16-pin PDIP |
| Package Pin Count | 16 pins |
| Package Row Spacing | 7.62 mm |
| Package Pitch | 0.300 in |
| 実装スタイル | Through-hole |
| ライフサイクル状態 | Inactive |
INA110KPG4 0.300 in ピン配置ガイド
INA110KPG4 (0.300 in パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA110KPG4.
詳細は データシート をご参照ください。
主な用途
INA110KPG4 の用途: 6 件s: Bridge Transducer Signal Conditioning, Low-Current Sensor Measurement, Biomedical Signal Acquisition, Industrial Pressure and Strain Monitoring, Laboratory Instrumentation, Data Acquisition Front End.
Bridge Transducer Signal Conditioning
The INA110KPG4 fits bridge-transducer front ends that produce a small differential voltage in the presence of a larger common-mode voltage. Its FET-input instrumentation-amplifier architecture avoids loading the sensor source, while selectable gains of 1, 10, 100, and 1000 allow the bridge output to be scaled before digitization. The 2.5 MHz bandwidth supports rapid response, and the single-ended output is convenient for a following data converter or measurement instrument. The 16-pin PDIP package also makes the amplifier practical for laboratory bridge boards and established through-hole assemblies.
Low-Current Sensor Measurement
The INA110KPG4 is appropriate for low-current sensors whose output impedance is too high for a conventional input stage. Its FET-input design supports low-bias-current measurement, while the instrumentation-amplifier configuration converts a weak differential sensor voltage into a single-ended signal referenced to ground or another selected reference. Gains of 10, 100, or 1000 can increase small-sensor output to a more useful measurement level. The 500 µV input offset specification must be considered alongside the selected gain when establishing the total measurement error.
Biomedical Signal Acquisition
The INA110KPG4 can condition differential biomedical or physiological sensor signals in a laboratory acquisition system. High input impedance reduces the burden placed on the sensor, and the selectable internal gains accommodate signal ranges from volts to millivolts. Its 2.5 MHz bandwidth is suitable for many general-purpose physiological measurement channels, while the single-ended output simplifies connection to an ADC input. Because medical applications can involve patient protection, the completed circuit must also satisfy the applicable safety, isolation, leakage, and electrode requirements of the finished system.
Industrial Pressure and Strain Monitoring
The INA110KPG4 suits pressure, load-cell, and strain-gauge monitoring circuits that operate in electrically noisy industrial environments. Its high-input-impedance differential stage reduces source loading, and the available gains of 1, 10, 100, and 1000 let designers select the signal scaling appropriate for the sensor range. The fast-settling, 2.5 MHz architecture provides useful response for changing mechanical loads, while the 500 µV offset specification helps define precision at higher gain. Board layout should keep input traces short and minimize leakage around the sensitive pins.
Laboratory Instrumentation
The INA110KPG4 is well suited to bench instrumentation that measures small differential voltages with a grounded single-ended output. Its 16-pin PDIP package is convenient for prototype and educational platforms, and its three internal amplifiers provide selectable gain without requiring a complete external instrumentation-amplifier network. The 2.5 MHz bandwidth permits reasonably fast measurements, while ±6 V to ±18 V supplies permit bipolar operation around ground. The reference connection gives the instrument designer an additional way to offset the output when matching an analog-to-converter input range.
Data Acquisition Front End
The INA110KPG4 can form the analog front end of a multichannel data-acquisition system for differential sensor signals. Selectable gains of 1, 10, 100, and 1000 normalize different input ranges before conversion, while the single-ended output can feed an ADC or sample-and-hold stage. Its 2.5 MHz bandwidth is adequate for many general-purpose acquisition channels and helps the amplifier settle following each conversion cycle. Designers should account for the 500 µV input offset, especially at gain 1000, and use clean grounding and supply arrangements to preserve measurement quality.
エンジニアリング参考データ: INA110KPG4 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA110KP |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 16-pin PDIP | 16-pin PDIP |
| Product Type | Fast-settling FET-input instrumentation amplifier | FET-input instrumentation amplifier |
| Package Pitch | 0.300 in (7.62 mm) | 16-pin PDIP |
主な差別化要因
- Fast 2.5 MHz instrumentation-amplifier bandwidth (vs INA110KP)
- Selectable gain range in a 16-pin PDIP footprint (vs INA110KP)
- Single-ended output with bipolar supplies (vs INA110KP)
設計ノート
Keep the INA110KPG4 input traces short, symmetric, and away from switching nodes and high-current return paths. High input impedance does not eliminate sensitivity to leakage from board contamination, flux residue, or long unprotected traces. Maintain a consistent ground reference between the two inputs and place any gain-setting or reference components close to the associated device pins.
Evaluate settling with the intended gain, source impedance, reference connection, and downstream load rather than relying only on the 2.5 MHz bandwidth figure. Long wiring, breadboard contacts, and connector capacitance can materially change effective response. Use short analog traces, a stable reference network, and an acquisition sequence that allows the output to settle before sampling.
Do not apply a single-ended signal directly between the differential inputs without accounting for the common-mode voltage and source impedance. Both input nodes and the reference network must remain inside the device's permitted operating conditions. Also verify the gain connection on the manufacturer pin diagram because the internal gain network uses package pins rather than a separate external feedback resistor.
Provide clean positive and negative supply rails within the specified ±6 V to ±18 V range. Decouple each supply rail close to the device, and connect the bypass return directly to the device ground reference. Poor supply grounding can degrade output behavior and inject noise into a low-level differential measurement even when the amplifier itself is correctly connected.
コンプライアンス情報
The component is an instrumentation amplifier rather than an automotive-qualified device. Specific environmental, material, and conflict-minerals declarations were not identified in the product information and remain unknown.