MAX232CWE-TG074 - 120kbps RS-232 Transceiver | Analog Devices
MPN: MAX232CWE-TG074 ✓ सक्रियMAX232CWE-TG074 अवलोकन
A MAX232 is a bipolar RS-232 interface IC that converts TTL/CMOS-compatible logic signals into RS-232 levels and converts incoming RS-232 signals back into logic levels. Within the interface hierarchy, it belongs to the line-driver and receiver category, interface IC family, and broader semiconductor product group. Two driver channels and two receiver channels allow one device to support a full-duplex serial link.
The MAX232CWE-TG074 supports operation at up to 120kbps, making it suitable for common serial-console, industrial-control, point-of-sale, and embedded equipment links. Its integrated level translation reduces the need for external RS-232 driver and receiver components. The 16-SOIC package supports conventional surface-mount assembly and is suitable for compact industrial and commercial equipment designs.
The MAX220 through MAX249 family is designed around EIA/TIA-232E and V.28/V.24 interface requirements, particularly where positive and negative supply voltages of approximately ±12V are not available. The CWE-TG074 ordering form identifies this part as a 16-SOIC RS-232 driver/receiver interface with two drivers and two receivers. Its interface architecture supports simultaneous transmit and receive paths when the host and peripheral provide complementary data and control signals.
Typical applications include configuration-port and console interfaces in embedded systems, communication links between microcontrollers and industrial peripherals, RS-232 test equipment, and legacy peripheral connections requiring bidirectional data transfer. Designers should pay particular attention to cable length, signal integrity, grounding, and the distinction between logic-level and RS-232 voltage domains.
For a new layout, place the MAX232CWE-TG074 close to the connector and preserve short, direct routes for the driver outputs and receiver inputs. Check the device's receive thresholds and the logic-level supply requirements of the connected controller. Add the charge-pump capacitors recommended by the manufacturer at the designated pins and avoid long stubs that could increase ringing or susceptibility to ESD events.
This product page combines the available manufacturer-family information, package identification, interface characteristics, application guidance, and drop-in replacement options in a format designed for engineering selection. For complete channel assignments, absolute maximum ratings, electrical characteristics, and layout guidance, use the official MAX232CWE datasheet and the exact pin-description table before releasing a PCB or production design.
के लिए ड्रॉप-इन विकल्प MAX232CWE-TG074 — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस सीरीज़ के वेरिएंट
समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं MAX232CWE-TG074 (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Interface Standard, Package, Product Type.
MAX232CWE+
✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापितकीमत के लिए संपर्क करें
डेटाशीट देखें →MAX232CWE+
✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापितकीमत के लिए संपर्क करें
डेटाशीट देखें →MAX232AWE+
✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित📋 संदर्भ विकल्प (कैटलॉग में नहीं)
MAX232CSE+
✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापितकीमत के लिए संपर्क करें
डेटाशीट देखें →MAX232EWE+
✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापितकीमत के लिए संपर्क करें
डेटाशीट देखें →MAX232CWE-TG074 विशेषताएं
| Product Type | RS-232 driver/receiver transceiver |
| Driver Channels | 2 |
| Receiver Channels | 2 |
| Maximum Data Rate | 120kbps |
| Interface Standard | EIA/TIA-232E and V.28/V.24 |
| पैकेज | 16-SOIC |
| माउंटिंग प्रकार | Surface mount |
| पिन की संख्या | 16 pins |
MAX232CWE-TG074 16-soic पिन कॉन्फ़िगरेशन गाइड
MAX232CWE-TG074 (16-soic पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: MAX232CWE-TG074.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
MAX232CWE-TG074 के लिए उपयुक्त है 6 अनुप्रयोगs: Embedded Serial Console, Industrial Control Equipment, Point-of-Sale Terminal Interface, Instrumentation and Test Equipment, Network Equipment Management Port, Printer and Legacy Peripheral Connection.
Embedded Serial Console
The MAX232CWE-TG074 fits embedded systems that expose a debug or configuration console through an RS-232 port. Its two-driver and two-receiver arrangement supports a full-duplex link, while the 120kbps maximum data rate is appropriate for command-line traffic, boot messages, and low-volume configuration transfers. Place the interface near the serial connector, route driver and receiver traces directly to protection circuitry, and follow the manufacturer charge-pump capacitor placement recommendations. The principal design consideration is maintaining clean logic-level timing while presenting compliant bipolar voltage levels at the connector.
अनुशंसित
Industrial Control Equipment
The MAX232CWE-TG074 can connect industrial-control equipment, test fixtures, and service ports that retain RS-232 interfaces. Two drivers and two receivers provide enough channels for a typical point-to-point full-duplex arrangement, and the 120kbps class accommodates many legacy supervisory protocols. The 16-SOIC package also simplifies panel-board and controller-board layouts. For industrial cable connections, verify the required operating-temperature grade and consider external surge or ESD protection because the connector environment may be harsher than the protected logic side of the circuit.
अनुशंसित
Point-of-Sale Terminal Interface
The MAX232CWE-TG074 is suitable for point-of-sale terminals, peripherals, and service equipment using an RS-232 command channel. The two transmit and two receive channels support full-duplex communication, and 120kbps is sufficient for many transaction, status, and configuration protocols. Place the IC near the DB9 or equivalent connector to minimize trace exposure and include the required charge-pump capacitors close to their designated pins. Validate the host-side logic levels and connector wiring before production, since RS-232 is a bipolar voltage interface rather than a direct 5V UART connection.
अनुशंसित
Instrumentation and Test Equipment
The MAX232CWE-TG074 can serve as the RS-232 interface in laboratory instruments, automated test systems, and bench controls. A 120kbps channel is well suited to remote commands and measurement data exchanges that do not require continuous high-bandwidth transfers. Its dual-driver and dual-receiver arrangement allows one IC to handle both control output and status input. Keep the analog or sensitive measurement circuitry separate from connector-associated return currents, use a defined ground strategy, and verify the receiver's logic output levels against the controller used in the instrument.
अनुशंसित
Network Equipment Management Port
The MAX232CWE-TG074 is appropriate for legacy network switches, routers, and management accessories that provide a serial console through RS-232. The 120kbps rate and two-channel transceiver arrangement are sufficient for console login, configuration commands, and diagnostic output. Place the interface near the connector and route the receiver path away from switching-power and clock signals to reduce coupling. Verify the required temperature and qualification conditions against the equipment's environmental specification, and apply connector-side protection when the management port is accessible from an external cable.
अनुशंसित
Printer and Legacy Peripheral Connection
The MAX232CWE-TG074 enables a modern controller or embedded board to communicate with printers, scanners, scales, and other legacy peripherals using RS-232. The 2/2 driver-receiver arrangement supports bidirectional command and status traffic, while the 120kbps rate suits many peripheral protocols. The device converts between the controller's logic-level UART and the bipolar signal expected by the RS-232 endpoint. Check connector pin numbering, signal direction, cable length, and logic thresholds before assembly, because these details determine whether the physical connection operates correctly despite using the same transceiver package.
अनुशंसित
अनुशंसित उत्पादों का सारांश
के लिए इंजीनियरिंग संदर्भ डेटा MAX232CWE-TG074 — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद | MAX232CWE | MAX232CWE+ | MAX232AWE+ | MAX232CSE+ | MAX232EWE+ |
|---|---|---|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Driver Channels | 2 | 2 | 2 | 2 | 2 | 2 |
| Receiver Channels | 2 | 2 | 2 | 2 | 2 | 2 |
मुख्य विशेषताएँ
- Established MAX232 family integration (बनामMAX232CWE)
- Existing 16-SOIC board footprint (बनामMAX232CSE+)
- Same channel count for embedded and industrial links (बनामMAX232AWE+)
- Full-duplex RS-232 channel allocation (बनामMAX232EWE+)
डिज़ाइन नोट्स
Place the MAX232CWE-TG074 close to the RS-232 connector so the driver outputs and receiver inputs form short, direct routes. Position the charge-pump capacitors close to their designated IC pins and use the exact values and topology shown in the manufacturer application circuit. Keep the logic-side UART traces away from connector wiring, and provide a direct return-path strategy so receiver thresholds are not affected by large ground-potential differences.
RS-232 uses a bipolar voltage interface, so do not connect its driver outputs directly to a 5V UART. Confirm which connector pins are TX, RX, ground, and control, and cross-check the controller UART TX and RX assignments. Keep external protection components close to the connector and maintain symmetric routing where possible. Verify rise and fall times and data-rate margin against the 120kbps device limit in the manufacturer datasheet.
Do not substitute a different MAX232 order code solely from the package count. The A, C, and E family variants can share a 16-SOIC footprint while differing in temperature range, supply requirements, logic thresholds, or qualification conditions. Before reusing an existing PCB, compare the complete ordering information, electrical characteristics, exposed package dimensions, and manufacturer pinout. Also confirm that the charge-pump capacitor values used by the original design match the replacement.
अनुपालन जानकारी
Compliance declarations were not identified in the available manufacturer-family and distributor information. Confirm the current declarations using the exact ordering code and manufacturer documentation.