MAX232BEAWE+T - 2/2 RS-232 Transceiver | Maxim Integrated
MPN: MAX232BEAWE+T ✓ AktifMAX232BEAWE+T Ringkasan
An RS-232 transceiver is an interface integrated circuit used to connect logic-level equipment to a serial port. The driver section converts low-voltage digital signals into RS-232-compatible levels, while the receiver section converts incoming RS-232 signals back into logic-compatible voltages. This transceiver belongs to the broader semiconductor hierarchy of interface ICs, line drivers and receivers, communication interfaces, and signal-conditioning semiconductors.
The MAX232BEAWE+T provides a practical way to add two RS-232 channels without using separate driver and receiver packages. Its 16-SOIC format supports conventional surface-mount PCB assembly. The manufacturer documentation identifies the component as a 2/2 full RS-232 transceiver, allowing it to support both transmission and reception functions in systems such as industrial controllers, data-acquisition equipment, service interfaces, and embedded serial-port equipment.
The MAX232 family is commonly used when legacy RS-232 equipment must communicate with a modern digital system. In a typical interface, the MAX232BEAWE+T sits between a host UART and an external RS-232 connector. Logic-level transmit signals enter the drivers, and the receivers return logic-level signals from the connector to the host. The IC therefore handles voltage translation at the physical interface while the UART handles character framing and serial protocol behavior.
Typical uses include point-to-point control links, configuration interfaces, instrument-control ports, industrial equipment communication, and embedded service connections. Two integrated channels can reduce the component count compared with separate single-channel transceiver circuits. Board designers must still account for the external charge-pump capacitors, signal grounding, connector protection, cable routing, and the electrical limits that apply to the selected RS-232 standard and connected equipment.
For layout, place the device close to the RS-232 connector or interface barrier, keep the driver and receiver routes short, and connect the charge-pump capacitor network exactly as shown in the manufacturer datasheet. The interface should also follow the recommended grounding and protection arrangement for the installed connector. Component values, electrical limits, timing characteristics, and environmental ratings should be confirmed against the datasheet for the exact MAX232BEAWE+T ordering code before release to production.
This page combines the exact MAX232BEAWE+T device identification, package information, interface-application guidance, verified drop-in cross-reference options, and practical PCB considerations in a format intended to accelerate engineering selection and implementation.
Alternatif penggantian untuk MAX232BEAWE+T — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian MAX232BEAWE+T (sama faktor bentuk dan footprint) — berbeda di dalam Package, Number of Drivers, Number of Receivers, Product Type.
MAX232ESE+T
✅ Drop-InKontak untuk harga
Lihat Datasheet →MAX232ACSE+T
✅ Drop-InKontak untuk harga
Lihat Datasheet →MAX232BEAWE+T Spesifikasi
| Product Type | RS-232 transceiver |
| Transceiver Configuration | 2/2 full duplex |
| Number of Drivers | 2 drivers |
| Number of Receivers | 2 receivers |
| Paket | 16-pin SOIC |
| Tipe Mounting | Surface mount |
MAX232BEAWE+T 16-pin soic Diamant Konfigurasi Panduan
Konfigurasi pin untuk MAX232BEAWE+T (16-pin soic pakai pakai). Penomoran pin, fungsi, dan diagram koneksi ditetapkan dalam datasheet produsen. Lihatnya untuk footprint dan pedoman perpindahan paruh.
Tidak ada data diatribut pin yang tersedia untuk MAX232BEAWE+T.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
MAX232BEAWE+T cocok untuk 6 aplikasis: Embedded UART Serial Interface, Industrial Controller Service Port, Data-Acquisition Instrument Interface, Point-to-Point Control Link, Instrument Configuration Port, Legacy Serial Connectivity.
Embedded UART Serial Interface
The MAX232BEAWE+T fits an embedded controller that must communicate through a conventional RS-232 port. Its two drivers and two receivers support two bidirectional channels, while the 16-SOIC package keeps the interface compact for surface-mount assembly. Connect the host UART signals to the logic-side pins and the RS-232 connector to the line-side pins. The external charge-pump network remains essential, so component values and placement should follow the manufacturer application circuit exactly.
Industrial Controller Service Port
The MAX232BEAWE+T is useful for a service or configuration port on an industrial controller that must retain compatibility with RS-232 service equipment. Two integrated channels can support separate data and control connections when the surrounding software or equipment architecture benefits from more than one line. The device handles only physical-level translation, so protocol framing remains the responsibility of the host UART. Connector protection, grounding, and operating-temperature requirements should be verified against the installation environment.
Data-Acquisition Instrument Interface
The MAX232BEAWE+T can connect laboratory or field data-acquisition equipment to a computer or controller through RS-232. Two full-duplex channels provide transmit and receive paths for commands and measurements in systems that do not require a more modern differential interface. Its 2/2 transceiver organization reduces the number of interface packages on the board. Designers should check supported data rate, cable limitations, signal levels, and grounding in the manufacturer documentation before finalizing the connection.
Point-to-Point Control Link
The MAX232BEAWE+T suits short point-to-point control links between legacy RS-232 equipment and a modern logic controller. The two drivers and two receivers allow bidirectional communication while the 16-SOIC package supports automated PCB assembly. The host UART generates and interprets characters, whereas the MAX232 performs RS-232 line-level conversion. Place the interface circuitry near the connector, route the serial nets away from sensitive analog paths, and apply suitable protection at an exposed user-accessible port.
Instrument Configuration Port
The MAX232BEAWE+T can provide a dedicated RS-232 configuration path for test instruments, peripheral controllers, and diagnostic equipment. One channel can carry setup commands while another supports returned status or measurement data, reducing component count compared with two single-direction interface packages. The design must preserve the voltage levels and timing required by both the host UART and attached equipment. Confirm the exact pin mapping, external capacitors, and maximum operating conditions in the manufacturer datasheet.
Legacy Serial Connectivity
The MAX232BEAWE+T is appropriate for maintaining a legacy RS-232 connection when redesigning equipment around a modern embedded platform. Two full RS-232 channels provide a straightforward interface between logic-level controller pins and a DB-style or smaller connector arrangement. Because the transceiver does not implement the communication protocol, software must manage framing, parity, handshaking, and timing. Validate connector pinouts and signal-ground practices before connecting two powered systems to avoid ground-related damage.
Data referensi engineering untuk MAX232BEAWE+T — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | MAX232ESE+T | MAX232ACSE+T |
|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Product Type | RS-232 transceiver | RS-232 transceiver | RS-232 transceiver |
| Driver Count | 2 | 2 | 2 |
| Receiver Count | 2 | 2 | 2 |
| Channel Configuration | 2/2 full duplex | 2/2 full duplex | 2/2 full duplex |
Diferensiator Kunci
- Two complete RS-232 channels in one package (vsMAX232ESE+T)
- Single-package dual-channel interface (vsMAX232ACSE+T)
- Surface-mount integration (vsMAX232ESE+T)
Catatan Desain
Place the MAX232BEAWE+T and its external charge-pump capacitors close to the RS-232 connector-side circuitry. Follow the manufacturer pin-description table and typical application diagram exactly for capacitor connections. Keep the route from the RS-232 pins to the connector short, avoid routing driver outputs beneath sensitive analog circuitry, and provide a direct return connection to the interface ground.
Do not assume that every MAX232-family ordering code has identical supply voltage, logic thresholds, temperature range, or package dimensions. Validate MAX232BEAWE+T against the schematic requirements and compare the exact pin names and limits before releasing a substitute to production. Also verify that the external capacitor values and ESR meet the manufacturer recommendations rather than copying a generic charge-pump network.
RS-232 driver outputs are high-voltage, high-slew signals and should be confined to the connector-side region of the PCB. Keep them away from clocks, sensors, analog inputs, and crystal circuits. Use a defined chassis or signal-ground strategy, keep cable protection close to the connector, and test the assembled system for conducted and radiated emissions under its intended operating conditions.
Informasi Konformitas
The leading + marking indicates the manufacturer's lead-free ordering option, but no explicit RoHS, REACH, AEC-Q100, halogen-free, or conflict-minerals statement is included in the technical records. Confirm these attributes with the manufacturer using the exact ordering code.