ADM3075EYRZ - 500 kbps RS-485 Transceiver | Analog Devices
部品番号: ADM3075EYRZ ✓ 生産中ADM3075EYRZ 概要
An RS-485 transceiver is the physical-layer interface between a logic-level controller and a balanced, multipoint bus. The differential signaling improves noise immunity, supports longer cable runs than single-ended interfaces, and allows multiple nodes to share a bus when their combined load permits it. The related RS-422 operating mode supports balanced point-to-point communication using the same transceiver family.
Key characteristics include a 3.3 V supply, a maximum signaling rate of 500 kbps, 1/8-unit-load bus loading, half-duplex operation, and ±15 kV ESD protection on the bus-facing pins. The DE and RE inputs allow the host to place the transmitter and receiver into high-impedance states when the controller is not actively driving or receiving data. A fail-safe receiver function helps the output remain in a defined state when the bus is idle or the driver is disabled.
The ADM3075E family is intended for industrial instrumentation, communications equipment, security systems, sensing equipment, and data-acquisition systems operating on RS-485 or RS-422 networks. Its 500 kbps capability suits moderate-speed control links, position feedback, remote sensors, industrial gateways, and supervisory communication rather than high-speed backbone traffic.
A half-duplex design requires only one pair of bus conductors, but software must control bus turnaround so that the driver does not contend with an active remote transmitter. Leave adequate termination at both physical ends of the bus and use the specified biasing arrangement to hold the differential bus at an idle state. Place the device close to the connector or protected board edge when cables enter the enclosure.
This page combines device specifications, drop-in replacement options, application guidance, and design notes that support component selection and PCB implementation. Request the current quotation, lead time, and lifecycle confirmation through the Request a Quote form on this page.
ドロップイン代替品: ADM3075EYRZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
ADM3075EWYRZ
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MAX3079EASD+T
✅ ドロップイン📋 参考代替品(カタログ未掲載)
XR3078XIDTR-F
✅ ドロップイン📋 参考代替品(カタログ未掲載)
SP3075EEN-L/TR
✅ ドロップイン📋 参考代替品(カタログ未掲載)
ADM3075EYRZ 仕様
| Product Type | RS-485/RS-422 Transceiver |
| 電源電圧 | 3.3 V |
| データレート | 500 kbps |
| Duplex Mode | Half Duplex |
| Bus Loading | 1/8 Unit Load |
| Driver Count | 1 Driver |
| Receiver Count | 1 Receiver |
| ESD Protection | ±15 kV |
| Supported Standards | RS-422 and RS-485 |
| Enable Control | DE and RE |
| Receiver Fail-Safe | Yes |
| パッケージ | 8-SOIC |
| 実装タイプ | Surface Mount |
| Minimum Operating Temperature | -40 °C |
| ライフサイクル状態 | Production |
| Datasheet Revision | Rev. F |
ADM3075EYRZ 8-soic ピン配置ガイド
ADM3075EYRZ (8-soic パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: ADM3075EYRZ.
詳細は データシート をご参照ください。
主な用途
ADM3075EYRZ の用途: 6 件s: Industrial Sensor and Remote I/O Networks, Building Access Control and Security Systems, Data Acquisition and Instrumentation, Industrial Communication Gateways, Position Feedback and Motor Control Systems, Telecommunications and Network Equipment.
Industrial Sensor and Remote I/O Networks
The ADM3075EYRZ fits RS-485 networks that connect remote temperature, pressure, level, and digital I/O modules to a central controller. Its 500 kbps maximum rate is ample for periodic sensor updates and command traffic, while the 1/8-unit-load receiver helps preserve bus capacity across multiple nodes. The 3.3 V supply integrates easily with modern microcontrollers. In a multidrop installation, place termination only at the two cable endpoints and use controlled bus turnaround so the half-duplex driver releases the bus before the receiver is enabled.
おすすめ
Building Access Control and Security Systems
The ADM3075EYRZ is suitable for half-duplex RS-485 links between a door controller and distributed access-control readers, request-to-exit panels, or alarm modules. Its 500 kbps rate supports short bursts of credential and status traffic without occupying the cable for extended periods. The ±15 kV ESD rating adds useful protection for equipment connected through external building wiring. Firmware should enforce one active driver per bus and use the receiver fail-safe function so the controller can detect an idle or undriven line predictably.
おすすめ
Data Acquisition and Instrumentation
The ADM3075EYRZ can connect laboratory or industrial instrumentation over an RS-422 or RS-485 link, allowing a controller to gather measurements from distributed analog-to-digital converters and sensor interfaces. The balanced bus helps reject common-mode noise present in industrial environments, while the 500 kbps ceiling provides sufficient bandwidth for moderate-rate acquisition. Keep the transceiver close to the protected connector, provide a solid ground reference, and verify that the number of attached 1/8-unit-load receivers remains within the intended bus budget.
おすすめ
Industrial Communication Gateways
The ADM3075EYRZ is useful in gateways that translate between a local microcontroller bus and RS-485 equipment such as drives, meters, programmable controllers, or remote terminal blocks. Its 3.3 V operating voltage supports low-voltage system partitioning, and the half-duplex architecture reduces the number of physical bus conductors. At 500 kbps, the link handles control and status frames efficiently. The gateway should implement deterministic arbitration, timeout handling, and controlled DE/RE transitions to avoid driver contention on shared segments.
おすすめ
Position Feedback and Motor Control Systems
The ADM3075EYRZ can carry incremental feedback, encoder status, or supervisory commands between a motor controller and remote axis modules using an RS-485 network. The 500 kbps rate supports real-time status exchange while leaving bandwidth for diagnostic traffic. Differential signaling is beneficial in motion systems where motor currents and switching equipment can create ground-offset noise. Maintain a low-impedance reference ground, use shielded cable where appropriate, and terminate the bus at each cable end rather than at every controller.
おすすめ
Telecommunications and Network Equipment
The ADM3075EYRZ supports low-speed management and control interfaces in telecommunications equipment, where a 3.3 V RS-485 link can connect rack modules over a balanced cable. The 1/8-unit-load receiver allows several modules to share a segment, and the half-duplex architecture simplifies the physical layer to a single bidirectional bus pair. The 500 kbps limit is appropriate for management traffic rather than high-speed payload transport. Panel-entry protection and chassis grounding remain important because the device is a physical-layer interface, not a surge-protection network.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ADM3075EYRZ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | ADM3075EWYRZ | MAX3079EASD+T | XR3078XIDTR-F | SP3075EEN-L/TR |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Maxim Integrated | MaxLinear | SP Micro |
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Supported Interfaces | RS-422 and RS-485 | RS-422 and RS-485 | RS-422 and RS-485 | RS-485 | RS-485 |
主な差別化要因
- Direct Analog Devices family choice for existing ADM3075E designs (vs ADM3075EWYRZ)
- ESD protection matches the leading bus-interface alternatives (vs MAX3079EASD+T)
- Same-footprint cross-brand sourcing option (vs SP3075EEN-L/TR)
設計ノート
Route the two bus conductors as a closely matched differential pair, connect the transceiver ground to the equipment ground reference, and place the device near the cable entry or protection network. Keep the DE and RE traces away from the bus traces to reduce capacitive coupling. For a half-duplex network, termination resistors belong at the two physical ends of the segment rather than beside every transceiver.
Follow the ADM3075E application guidance for supply decoupling and bus-side protection. Place the local bypass capacitor immediately across the device supply pins, with the connection loop kept short. Verify the 3.3 V rail tolerance, ground continuity, and the voltage seen by the receiver under bus-idle and bus-fault conditions before releasing the design for production.
Do not enable the driver while another node is transmitting. In firmware, disable DE, allow the transceiver propagation delay and bus release time to elapse, and then enable RE for reception. Also avoid populating termination across every node because excessive loading reduces the differential signal amplitude and can prevent reliable communication at the longest cable lengths.
コンプライアンス情報
The ADM3075E family is listed in production by Analog Devices. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the current manufacturer product documentation or declaration.