ADM3075EYRZ - 500 kbps RS-485 Transceiver | Analog Devices
MPN: ADM3075EYRZ ✓ 啟用中ADM3075EYRZ 概覽
An RS-485 transceiver is the physical-layer interface between a logic-level controller and a balanced, multipoint bus. The differential signaling improves noise immunity, supports longer cable runs than single-ended interfaces, and allows multiple nodes to share a bus when their combined load permits it. The related RS-422 operating mode supports balanced point-to-point communication using the same transceiver family.
Key characteristics include a 3.3 V supply, a maximum signaling rate of 500 kbps, 1/8-unit-load bus loading, half-duplex operation, and ±15 kV ESD protection on the bus-facing pins. The DE and RE inputs allow the host to place the transmitter and receiver into high-impedance states when the controller is not actively driving or receiving data. A fail-safe receiver function helps the output remain in a defined state when the bus is idle or the driver is disabled.
The ADM3075E family is intended for industrial instrumentation, communications equipment, security systems, sensing equipment, and data-acquisition systems operating on RS-485 or RS-422 networks. Its 500 kbps capability suits moderate-speed control links, position feedback, remote sensors, industrial gateways, and supervisory communication rather than high-speed backbone traffic.
A half-duplex design requires only one pair of bus conductors, but software must control bus turnaround so that the driver does not contend with an active remote transmitter. Leave adequate termination at both physical ends of the bus and use the specified biasing arrangement to hold the differential bus at an idle state. Place the device close to the connector or protected board edge when cables enter the enclosure.
This page combines device specifications, drop-in replacement options, application guidance, and design notes that support component selection and PCB implementation. Request the current quotation, lead time, and lifecycle confirmation through the Request a Quote form on this page.
直接替換替代品,適用於 ADM3075EYRZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
ADM3075EWYRZ
✅ 直接替換📋 參考替代品(不在目錄中)
MAX3079EASD+T
✅ 直接替換📋 參考替代品(不在目錄中)
XR3078XIDTR-F
✅ 直接替換📋 參考替代品(不在目錄中)
SP3075EEN-L/TR
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3075EYRZ 規格
| Product Type | RS-485/RS-422 Transceiver |
| 供應電壓 | 3.3 V |
| 資料速率 | 500 kbps |
| Duplex Mode | Half Duplex |
| Bus Loading | 1/8 Unit Load |
| Driver Count | 1 Driver |
| Receiver Count | 1 Receiver |
| ESD Protection | ±15 kV |
| Supported Standards | RS-422 and RS-485 |
| Enable Control | DE and RE |
| Receiver Fail-Safe | Yes |
| 封裝 | 8-SOIC |
| 安裝類型 | Surface Mount |
| Minimum Operating Temperature | -40 °C |
| 生命週期狀態 | Production |
| Datasheet Revision | Rev. F |
ADM3075EYRZ 8-soic 腳位配置指南
ADM3075EYRZ(8-soic 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: ADM3075EYRZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADM3075EYRZ 適用於 6 應用s: Industrial Sensor and Remote I/O Networks, Building Access Control and Security Systems, Data Acquisition and Instrumentation, Industrial Communication Gateways, Position Feedback and Motor Control Systems, Telecommunications and Network Equipment.
Industrial Sensor and Remote I/O Networks
The ADM3075EYRZ fits RS-485 networks that connect remote temperature, pressure, level, and digital I/O modules to a central controller. Its 500 kbps maximum rate is ample for periodic sensor updates and command traffic, while the 1/8-unit-load receiver helps preserve bus capacity across multiple nodes. The 3.3 V supply integrates easily with modern microcontrollers. In a multidrop installation, place termination only at the two cable endpoints and use controlled bus turnaround so the half-duplex driver releases the bus before the receiver is enabled.
推薦
Building Access Control and Security Systems
The ADM3075EYRZ is suitable for half-duplex RS-485 links between a door controller and distributed access-control readers, request-to-exit panels, or alarm modules. Its 500 kbps rate supports short bursts of credential and status traffic without occupying the cable for extended periods. The ±15 kV ESD rating adds useful protection for equipment connected through external building wiring. Firmware should enforce one active driver per bus and use the receiver fail-safe function so the controller can detect an idle or undriven line predictably.
推薦
Data Acquisition and Instrumentation
The ADM3075EYRZ can connect laboratory or industrial instrumentation over an RS-422 or RS-485 link, allowing a controller to gather measurements from distributed analog-to-digital converters and sensor interfaces. The balanced bus helps reject common-mode noise present in industrial environments, while the 500 kbps ceiling provides sufficient bandwidth for moderate-rate acquisition. Keep the transceiver close to the protected connector, provide a solid ground reference, and verify that the number of attached 1/8-unit-load receivers remains within the intended bus budget.
推薦
Industrial Communication Gateways
The ADM3075EYRZ is useful in gateways that translate between a local microcontroller bus and RS-485 equipment such as drives, meters, programmable controllers, or remote terminal blocks. Its 3.3 V operating voltage supports low-voltage system partitioning, and the half-duplex architecture reduces the number of physical bus conductors. At 500 kbps, the link handles control and status frames efficiently. The gateway should implement deterministic arbitration, timeout handling, and controlled DE/RE transitions to avoid driver contention on shared segments.
推薦
Position Feedback and Motor Control Systems
The ADM3075EYRZ can carry incremental feedback, encoder status, or supervisory commands between a motor controller and remote axis modules using an RS-485 network. The 500 kbps rate supports real-time status exchange while leaving bandwidth for diagnostic traffic. Differential signaling is beneficial in motion systems where motor currents and switching equipment can create ground-offset noise. Maintain a low-impedance reference ground, use shielded cable where appropriate, and terminate the bus at each cable end rather than at every controller.
推薦
Telecommunications and Network Equipment
The ADM3075EYRZ supports low-speed management and control interfaces in telecommunications equipment, where a 3.3 V RS-485 link can connect rack modules over a balanced cable. The 1/8-unit-load receiver allows several modules to share a segment, and the half-duplex architecture simplifies the physical layer to a single bidirectional bus pair. The 500 kbps limit is appropriate for management traffic rather than high-speed payload transport. Panel-entry protection and chassis grounding remain important because the device is a physical-layer interface, not a surge-protection network.
推薦
推薦產品摘要
工程參考資料,適用於 ADM3075EYRZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADM3075EWYRZ | MAX3079EASD+T | XR3078XIDTR-F | SP3075EEN-L/TR |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Maxim Integrated | MaxLinear | SP Micro |
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Supported Interfaces | RS-422 and RS-485 | RS-422 and RS-485 | RS-422 and RS-485 | RS-485 | RS-485 |
主要差異化特點
- Direct Analog Devices family choice for existing ADM3075E designs (對比ADM3075EWYRZ)
- ESD protection matches the leading bus-interface alternatives (對比MAX3079EASD+T)
- Same-footprint cross-brand sourcing option (對比SP3075EEN-L/TR)
設計說明
Route the two bus conductors as a closely matched differential pair, connect the transceiver ground to the equipment ground reference, and place the device near the cable entry or protection network. Keep the DE and RE traces away from the bus traces to reduce capacitive coupling. For a half-duplex network, termination resistors belong at the two physical ends of the segment rather than beside every transceiver.
Follow the ADM3075E application guidance for supply decoupling and bus-side protection. Place the local bypass capacitor immediately across the device supply pins, with the connection loop kept short. Verify the 3.3 V rail tolerance, ground continuity, and the voltage seen by the receiver under bus-idle and bus-fault conditions before releasing the design for production.
Do not enable the driver while another node is transmitting. In firmware, disable DE, allow the transceiver propagation delay and bus release time to elapse, and then enable RE for reception. Also avoid populating termination across every node because excessive loading reduces the differential signal amplitude and can prevent reliable communication at the longest cable lengths.
合規資訊
The ADM3075E family is listed in production by Analog Devices. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the current manufacturer product documentation or declaration.